http://www.xlpecable.com/zmscable/cable_655_1.html
Http://www.Zmscable.Com/powercables/825.Html -
Specific property for usage of 110kv~220kv xlpe high-voltage cable 1. Cable's conductor highest working temperature is allowed up to 90⺠c, and overload when meet an emergency is 130⺠c, when short circuit (in â?¤ 5 seconds) the highest temperature is 250⺠c 2. When installing or laying cable, the ambient temperature should be less than -20⺠c, and have to give a preheat to cable. 3. The minimum bending diameter(in follow the table): Note: in form, d0 is a real test value to cable's outer diameter. 4. Allowed biggest axial traction force to outer diameter when laying cable (not consider the radial lateral-pressure at bent set ion) t=kã? core no. Ã? section (kg), in formula, the coefficient k value should be: the copper core get 7, the aluminum core get 4. 5. Allowed biggest lateral-press p, when cable is being bent The single core cable is required pâ?¤ 500kg/m. P=t/r (t is indicated axial traction force; r is indicated radius of bent-wheel), knowing from above formula, as the traction force is made up by length and weight of cable. So it lets p to applying requirement as above. Then the diameter of bent-wheel should be widened. 6. Cable laying is not being restricted by drop.
1.Voltage: 0.6/1kv 2:conductor:copper 3.Xlpe insulated 4. Steel wire arnoured 5. Pvc sheathed 6.Used for underground
PVC Insulated & Sheathed Power Cables Standards: IEC60502, GB/T12706-2008 Application: It is suitable to be installed in duct, tray or direct burial, with rated voltage of U0/U (0.6/1KV) for transmitting electricity. Service Conditions: 1. Regular nominal cross-sectional areas: 1.5 mm2, 2.5 mm2, 4 mm2, 6 mm2, 10 mm2, 16 mm2, 25 mm2, 35 mm2, 50 mm2, 70 mm2, 95 mm2, 120 mm2, 150 mm2, 185 mm2, 240 mm2, 300 mm2, 400 mm2, 500 mm2, 630 mm2, 800 mm2, 1000 mm2, 1200 mm2 2. It is recommended that the installation instructions indicated by the Local Electric Code, or any equivalent, be followed, so that the safeguarding of persons and the integrity of the product will not be affected by eciencies in the installation.
This type of xlpe insulated power cable is used for power transmission and distribution line¡£ xlpe power cable boasts not only characteristics of excellent electricity, mechanism, heat and aging-resistant, environment stress-resistant and chemical corrosion-resistant, but also simple structure, light weight, no restriction by laying drop, and high temperature allowance for long-term working. Xlpe has excellent dielectric properties. It can be laid with no drop restriction.Various of flame-retardant and non-flame retardant xlpe cable can be manufactured with three technology(peroxide, silane and irradiation crosslinking)£» some of special xlpe cable can be manufactured according to the other standards required by customs.Xlpe cable having higher long-term working temperature and greater current rating. Drum or as your requirement
Xlpe insulation power cable.
Executive standard It is manufactured acconding to GB/T 5023-2008,JB/T 8734-2016 standards.(Equivalent national standard of IEC60227). Application B serie are used for fixed laying in engine devices of AC rated voltage 450/750V of lower, R serie are used for household electrical appliances ,small electrical tools, instruments and engine lighting of AC rated voltage 450/750V or lower.
Application :- The Power Cables are used under ground as well as over head transmission of power in power plants, industries, projects and all other electrical installations. Features :- Manufactured from bright annealed 99.97% pure bare copper & aluminum conductors. These cables are insulated with PVC compound. Taped/Extruded inner sheath. Round steel wire / flat galvanised steel grip armoured. The inner & outer sheaths can be PVC, HR PVC, FRLS, HR-FRLS or FR depending upon the application and requirement. Technical Data :- Working Voltage : Up to 1100 V Temperature Range : -15�°C to +70�°C or +85�°C in HR PVC Power Cable Sizes : 1.50 Sq. mm to 400.00 Sq. mm in 2, 3, 3 & 4 core. Copper Control Cable Sizes : 1.50 Sq. mm, 2.50 Sq. mm up to 24 cores. Color Codes : 2 Core Cables - Red, Black 3 Core Cables - Red, Yellow & Blue 3 Core Cables - Red, Yellow, Blue & Black (for Neutral) 4 Core Cables - Red, Yellow, Blue & Black 5 Core Cables - Red, Yellow, Blue, Black & Grey 6 Core Cables & above - Adjacent cores are blue for reference and yellow for direction in each lay Black outer sheath Specification : IS:1554 (Part-1) Packing : 500 / 1000 meters on drums
Application :- The XLPE (Cross Link Poly Ethylene) Power Cables are used under ground as well as over head transmission of power in power plants, industries, projects and all other electrical installations. Features :- Manufactured from bright annealed 99.97% pure bare copper & aluminum conductors. These cables are insulated with XLPE compound. Taped/Extruded inner sheath. Round steel wire / flat galvanised steel grip armoured. The outer sheaths can be PVC, HR PVC, FRLS or FR depending upon the application and requirement. Technical Advantage of XLPE Insulation :- Higher current rating, higher short circuit rating (approx 1.2 times that of PVC), thermosetting in nature, higher insulation resistance (1000 times more than PVC cables), higher moisture resistance, better resistance to surge currents, low dielectric losses, better resistance to chemicals and corrosion, longer service life. Comparatively higher cable operating temperature 90�°C and short circuit temperature 250�°C. Technical Data :- Working Voltage : Up to 1100 V Temperature Range : -15�°C to +90�°C Power Cable Sizes : 1.50 Sq. mm to 400.00 Sq. mm in 2, 3, 3 Copper Control Cable Sizes : 1.50 Sq. mm, 2.50 Sq. mm up to 24 cores. Color Codes : 2 Core Cables - Red, Black 3 Core Cables - Red, Yellow & Blue 3 Core Cables - Red, Yellow, Blue & Black (for Neutral) 4 Core Cables - Red, Yellow, Blue & Black 5 Core Cables - Red, Yellow, Blue, Black & Grey 6 Core Cables & above - Adjacent cores are blue for reference and yellow for direction in each lay Black outer sheath Specification : IS:7098 (Part-1) Packing : 500 / 1000 meters on drums
The design conforms to Chinese standard GB/T 12706-2002 and I EC60502. The product series include 3.6/6kV to 26/35kV single-core and 3-core XLPE insulated power cables. XLPE insulated cables is working at 90. It has good electrical performance, simple structure, small diameter, light weight, easy using without level difference limit. The company has the advanced dry XLPE triple-layer production line. The whole line is controlled by computer with advanced alignment-free extruder to control thickness of the inner and outer layer as well as co-centricity, and keep the good quality. Use conditions 1. Ambient temperature is not lower than 0 (should be pre-heated if lower than 0)not limit of level difference 2. Min. bending radius of installation Single-core without armoring:20D 3-core without armoring:15D Single-core with armoring:15D 3-core with armoring:12D (Dis the outer diameter of the cable) 3. Cable working temperature: PVC sheath not more than 90, PE sheath not more than 80 4. The maximum rated temperature is 90,not more than 250 in the case of short-circuit(1astin9 5s max.) 5. One or two single-core cable is not allowable laid up in the iron pipes.
Insulation colour: single core:Brown or Blue Two core: Brown and Blue Three core: Brown,Blue and Grey Four core: Grey, Black, Brown and Blue Five core: Green/Yellow, Black, Brown,Blue and Grey http://www.zmscable.com
1.Model no.:q\xdzj 01-2008 2.Many kinds of colors 3.Competitive price 4.High quality 5. Prompt delivery 6. Excellent reputation in china mainland 7. Obtained these certificates : ISO 9001:2000, ISO14001:2004, CCC, AAA+ and China famous brand 1.Usual packing length:1000m per roll 2.Special packing available according to customer
0.6/1kv low voltage xlpe insulated power cable factory direct supply Type Description Application Yjv yjlv Copper(aluminum)conductor, xlpe insulated and pvc sheathed cable For laying indoors, in tunnel or pipe, unable to bear external mechanical force Yjy yjly Copper(aluminum)conductor, xlpe insulated and pe sheathed cable Yjv22 yjlv22 Copper(aluminum)conductor, xlpe insulated, steel tape armored and pvc sheathed cable For laying indoors, in tunnel, cable trench, or direct in ground, can bear external mechanical force , while unable to bear large tension Yjv23 yjlv23 Copper(aluminum)conductor, xlpe insulated, steel tape armored and pe sheathed cable Yjv32 yjv42 yjlv42 yjlv32 Copper(aluminum)conductor, xlpeinsulated, thin(thick) steel wire armored and pvc sheathed cable For laying in high drop area , can bear external mechanical force and certain tension Yjv33 yjv43 yjlv43 yjlv33 Copper(aluminum)conductor, xlpe insulated, thin(thick) steel wire armored and pe sheathed cable Notes: we can also produce non-magnetic steel tape and metal wire armored cable Yiteng cable technology hebei co., ltd. Yiteng cable not only produce kinds of cables, like Aluminum alloy cable, Control cable, Computer cable, Shield cable, Abc cable, Power cable, Rubber cable, Armored cable, Low voltage cable, Medium voltage cable, Fire resistant cable, Flame retardant cable, But also produce cables of customers' special requirement. Let's win together! Contact: Ms. Angie chen Mob: 86-13785179568 Email: angiechenyantao(at)163(dot)com By standard export drums or as per customer's requirement
Glazing glass is a combination of two or more pieces of glass spaced apart with a spacer bar and hermetically sealed with a primary and secondary sealant to form a single unit with one or more air spaces between each other. Max size :3300*12000mm Main character : Energy saving , improving the thermal performance Sound insulated Security and comfort Component : 1.� Glass items:� consists of hard or soft low E glass ,reflective glass ,clear glass ,tinted glass, with types of flat tempered ,bent ,laminated processing ,according to the application 2.� Spacer bar :is the material used to separate the two glass lites in an IGU. It can be made by aluminum,stainless steel,hybrid ,plastic material . The spacer width usually from 6mm-18mm.
This cables are used as power distribution and transmission at rated voltage of 0.6/1kV. Working temperature: max 70 degree centigrade Short circuit: 5 seconds at max 160 degree centigrade Models: VV: Copper Core, PVC insulated and Sheathed Electric Cable VLV: Aluminum Core, PVC insulated and Sheathed Electric Cable VV22: Copper Core, PVC insulated, Steel tape armoured, PVC Sheathed Electric Cable VLV22: Aluminum Core, PVC insulated, Steel tape armoured, PVC Sheathed Electric Cable VV32: Copper Core, PVC insulated, Fine steel wire armoured, PVC Sheathed Electric Cable VLV32: Copper Core, PVC insulated, Fine steel wire armoured, PVC Sheathed Electric Cable VV42: Copper Core, PVC insulated, Heavy steel wire armoured, PVC Sheathed Electric Cable VLV42: Aluminum Core, PVC insulated, Heavy steel wire armoured, PVC Sheathed Electric Cable ZR-VV: Copper Core, PVC insulated and Sheathed, Flame retardant Electric Cable ZR-VLV: Aluminum Core, PVC insulated and Sheathed, Flame retardant Electric Cable Installation: While installation, the temperature should not lower than 0 degrees Celsius, if the ambient temperature is lower than 0 degrees Celsius, the cable should be preheated. The bending radius should not be smaller than 8 times of diameter of cable. After installation, voltage withstand test for 15 minutes at 8.4kV direct current should be performed.
PVC Sheathed armoured power cable The product not only has good electric capability, but also has good chemical stabilization, simple structure, easy to use, and the laying of cable do not be limited by the fall. It is widely used at the transformer circuit which rated voltage is 6000V or under. The product is produced against IEC60502 and IEC60331, and the product can be produced against the standard of BS, DIN, and the standard required by the clients. 1. The long-term permissible operation temperature of the conductor shall not be higher than 70. 2. The max temperature of the conductor of cable should less then 160 when short circuit. (less then 5 second). 3. The cable is not limited by drop in level when being laid, and the environment temperature shall not be lower than 0. 4. Perfect chemical stability, resistant against acids, alkalis, grease and organic solvents, and flame retardance. 5. Light weight, perfect bending properties, installed and maintained easily and conveniently. 6. Rated voltage: 0.6/1kV, 3.6/6kV. 7. Number of cores: One, two, three, four, five. Drum