PVC Insulated & Sheathed Power Cables
Standards: IEC60502, GB/T12706-2008
Application: It is suitable to be installed in duct, tray or direct burial, with rated voltage of U0/U (0.6/1KV) for transmitting electricity.
Service Conditions:
1. Regular nominal cross-sectional areas: 1.5 mm2, 2.5 mm2, 4 mm2, 6 mm2, 10 mm2, 16 mm2, 25 mm2, 35 mm2, 50 mm2, 70 mm2, 95 mm2, 120 mm2, 150 mm2, 185 mm2, 240 mm2, 300 mm2, 400 mm2, 500 mm2, 630 mm2, 800 mm2, 1000 mm2, 1200 mm2
2. It is recommended that the installation instructions indicated by the Local Electric Code, or any equivalent, be followed, so that the safeguarding of persons and the integrity of the product will not be affected by eciencies in the installation.
This cables are used as power distribution and transmission at rated voltage of 0.6/1kV. Working temperature: max 70 degree centigrade Short circuit: 5 seconds at max 160 degree centigrade Models: VV: Copper Core, PVC insulated and Sheathed Electric Cable VLV: Aluminum Core, PVC insulated and Sheathed Electric Cable VV22: Copper Core, PVC insulated, Steel tape armoured, PVC Sheathed Electric Cable VLV22: Aluminum Core, PVC insulated, Steel tape armoured, PVC Sheathed Electric Cable VV32: Copper Core, PVC insulated, Fine steel wire armoured, PVC Sheathed Electric Cable VLV32: Copper Core, PVC insulated, Fine steel wire armoured, PVC Sheathed Electric Cable VV42: Copper Core, PVC insulated, Heavy steel wire armoured, PVC Sheathed Electric Cable VLV42: Aluminum Core, PVC insulated, Heavy steel wire armoured, PVC Sheathed Electric Cable ZR-VV: Copper Core, PVC insulated and Sheathed, Flame retardant Electric Cable ZR-VLV: Aluminum Core, PVC insulated and Sheathed, Flame retardant Electric Cable Installation: While installation, the temperature should not lower than 0 degrees Celsius, if the ambient temperature is lower than 0 degrees Celsius, the cable should be preheated. The bending radius should not be smaller than 8 times of diameter of cable. After installation, voltage withstand test for 15 minutes at 8.4kV direct current should be performed.
Application :- The Power Cables are used under ground as well as over head transmission of power in power plants, industries, projects and all other electrical installations. Features :- Manufactured from bright annealed 99.97% pure bare copper & aluminum conductors. These cables are insulated with PVC compound. Taped/Extruded inner sheath. Round steel wire / flat galvanised steel grip armoured. The inner & outer sheaths can be PVC, HR PVC, FRLS, HR-FRLS or FR depending upon the application and requirement. Technical Data :- Working Voltage : Up to 1100 V Temperature Range : -15�°C to +70�°C or +85�°C in HR PVC Power Cable Sizes : 1.50 Sq. mm to 400.00 Sq. mm in 2, 3, 3 & 4 core. Copper Control Cable Sizes : 1.50 Sq. mm, 2.50 Sq. mm up to 24 cores. Color Codes : 2 Core Cables - Red, Black 3 Core Cables - Red, Yellow & Blue 3 Core Cables - Red, Yellow, Blue & Black (for Neutral) 4 Core Cables - Red, Yellow, Blue & Black 5 Core Cables - Red, Yellow, Blue, Black & Grey 6 Core Cables & above - Adjacent cores are blue for reference and yellow for direction in each lay Black outer sheath Specification : IS:1554 (Part-1) Packing : 500 / 1000 meters on drums
Application :- The XLPE (Cross Link Poly Ethylene) Power Cables are used under ground as well as over head transmission of power in power plants, industries, projects and all other electrical installations. Features :- Manufactured from bright annealed 99.97% pure bare copper & aluminum conductors. These cables are insulated with XLPE compound. Taped/Extruded inner sheath. Round steel wire / flat galvanised steel grip armoured. The outer sheaths can be PVC, HR PVC, FRLS or FR depending upon the application and requirement. Technical Advantage of XLPE Insulation :- Higher current rating, higher short circuit rating (approx 1.2 times that of PVC), thermosetting in nature, higher insulation resistance (1000 times more than PVC cables), higher moisture resistance, better resistance to surge currents, low dielectric losses, better resistance to chemicals and corrosion, longer service life. Comparatively higher cable operating temperature 90�°C and short circuit temperature 250�°C. Technical Data :- Working Voltage : Up to 1100 V Temperature Range : -15�°C to +90�°C Power Cable Sizes : 1.50 Sq. mm to 400.00 Sq. mm in 2, 3, 3 Copper Control Cable Sizes : 1.50 Sq. mm, 2.50 Sq. mm up to 24 cores. Color Codes : 2 Core Cables - Red, Black 3 Core Cables - Red, Yellow & Blue 3 Core Cables - Red, Yellow, Blue & Black (for Neutral) 4 Core Cables - Red, Yellow, Blue & Black 5 Core Cables - Red, Yellow, Blue, Black & Grey 6 Core Cables & above - Adjacent cores are blue for reference and yellow for direction in each lay Black outer sheath Specification : IS:7098 (Part-1) Packing : 500 / 1000 meters on drums
33kV XLPE Insulation DSTA PVC Sheath Power Cable
11KV 3c 240mm2 XLPE Insulation DSTA PVC Sheathed Power cable
Application:XLPE Cable is used indoor or outdoor, in tunnel, cable furrow or pipe, to be laid underground, be applicable to the well, water inside and fall in the bad soil. Standards:IEC60502-2, BS7870-4, BS7870-7, BS7870-8 Cores: 1 Core, 3 Core Conductor:Cu or Aluminum Insulation:XLPE (Cross-Linked Polyethylene) Armor:non-armor, steel tape armored, steel wire armored Sheath:PVC or PE Sheath Color:Black or Colors Product Description: - XLPE insulated PVC sheathed power cable (XLPE/PVC Cable) - XLPE insulated steel tape armored PVC sheathed power cable (XLPE/STA/PVC Cable) - XLPE insulated steel wire armored PVC sheathed power cable (XLPE/SWA/PVC Cable) - Flame retardant XLPE insulated PVC sheathed power cable (FR/XLPE/PVC Cable) - Flame retardant XLPE insulated steel tape armored PVC sheathed power cable (FR/XLPE/STA/PVC Cable) - Flame retardant XLPE insulated steel wire armored PVC sheathed power cable (FR/XLPE/SWA/PVC Cable) FR â?? Flame Retardant http://www.xlpecable.com
We offer Bharat Cab PVC Insulated Power Cable that are made as per IS: 1554 (Part I) up to 1.1 KV grade. The PVC Insulated Power Cable, we supply, is suitable for low-tension, fixed installation and are also used as control cables for process and manufacturing industries. The clients can avail the PVC Insulated Power Cable from us at the market leading price. Features : - Strong and made for easy handling. - Resistant to water, moisture, oils and chemicals. - PVC black compounds can resist ultraviolet degradation. - Specially formulated PVC is flame retardant and reduces emission of halogens and smoke. Suitable For : Continuous use between 30oC and 70oC and upto 85oC for Heat Resistant applications.
Application :- These multi core flexible cables are used for wiring in control panels, machines and various electrical installations in dry and damp interiors specially under typical industrial environmental conditions. Features :- Manufactured from bright annealed 99.97% pure bare copper conductors, these cables offer low conductor resistance. These wires are insulated with a special grade PVC compound formulated and manufactured in-house. The tough robust outer PVC jacket protects it from oils, greases and various chemicals and abrasions, thereby giving long life and electrical safety. Technical Data :- Working Voltage : Up to 1100 V Temperature Range : -15�°C to +70�°C Sizes : 0.50 to 4.00 Sq. mm in 2 core to 19 cores & 6.00 to 120.00 Sq. mm in 3 core and 4 core. Color Codes : Black and Grey Outer Sheath 2 Core Cables - Red, Black 3 Core Cables - Red, Black & Green (for Earth) 4 Core Cables - Red, Yellow, Blue & Green (for Earth) 5 Core Cables - Red, Yellow, Blue, Black & Grey Specification : IS:694 Packing : In 90 meter coils, higher sizes in drums.
Application :- These single core flexible cables are used for wiring in control panels, machines and various electrical installations In small, medium and large industries. Features :- Manufactured from bright annealed 99.97% pure bare copper conductors, these cables have low conductor resistance. These wires are insulated with a special grade PVC compound formulated and manufactured in-house which is impervious to water, oil, grease, acids, etc. and are tough to protect from any mechanical abuses. Technical Data :- Working Voltage : Up to 1100 V Temperature Range : -15�°C to +70�°C Sizes : 0.50 to 50.00 Sq. mm with ISI mark & 70.0 to 40.0 Sq. mm generally conforming to IS:694 Color Codes : Red, Yellow, Blue, Black, Grey, White, Pink, Green, Violet, Brown, Orange Specification : IS:694 Packing : In 90 meter coils, higher sizes in drums.