Relay , Diodes , MCB Miniature circuit breakers, copper wire and cable , flood ( street light ) , motor starter , submersible cable .
Electric relays, power relay, PCB relay, electromagnetic relay, electronic component, automotive relay, over current relay, under voltage relay, hermetically sealed relay.
Domestic wire, house wire, submersible cables (flat / round), single core flexible cable, multi core flexible cable, xlpe insulated pvc sheathed power cable, xlpe insulated armoured control cable, pvc insulated armoured control cable, xlpe insulated unarmoured control cable, pvc insulated unarmoured control cable, optical fiber cable, optical fiber armoured cable, ftth drop cable, instrumentation cable, shielded cable. networking cable, cat 6 cable, cat 6 utp cable, cat 6 stp cable, cat 6 sftp cable, cat 6 ftp cable fire alarm cable, fire survival cable, data cable, electric cable, coaxial cable, cctv cable, travelling cable, lift cable, lift traveling cable.
Electrical components, plug in relays, electronics hardware, circuit breakers, fuses.
Integrated circuits ics, diodes, capacitors, resistor, transistor, relays, connectors, semiconductors, and other components..Export
Sensors, encoders, cable relays, industrial cables, partex marking system, cable conduits.
GSM BASED RELAY ON/OFF SWITCH 1 CHANNEL TO 4 CHANNEL Remote control using a MOBILE phone from anywhere in the world! - New Feature - Schedule Timer Added The GSM BASED RELAY ON/OFF SWITCH 1 CHANNEL TO 4 CHANNEL is a GSM remote control switch, it connects to the cell phone network and like a cell phone has its own cell phone number. The GSM switch is activated by Sending SMS to its cell phone number, it has 1 TO 4 independent relay switches with normally open and normally closed switch contacts, these can be programmed to switch on and Off By Sending SMS A1 B1 C1 -A0 B0 C0 ..... . SMS text message command. It can report the relay status by sending back a text message. Applications Specification â?¢ Operating Voltage - 12VAC/ DC 2 Amps â?¢ SIM card any Network SPECIFICATION : POWER INPUT: 12v DC-2 Amps RELAY: 250v 7A, 24 10A LIGHT INDICATION: FIRST LED: RED- POWER LIGHT SECOND LED: GREEN â?? BLINK 2 SECONDS ONCE GSM CONNECTED TO NETWORK RELAY ON CORRESPONDING LED WILL GLOWGSM BASED RELAY ON/OFF SWITCH 1 CHANNEL TO 4 CHANNEL Remote control using a MOBILE phone from anywhere in the world! - New Feature - Schedule Timer Added Specification â?¢ Operating Voltage - 12VAC/ DC 2 Amps â?¢ SIM card any Network SPECIFICATION : POWER INPUT: 12v DC-2 Amps RELAY: 250v 7A, 24 10A LIGHT INDICATION: FIRST LED: RED- POWER LIGHT SECOND LED: GREEN BLINK 2 SECONDS ONCE GSM CONNECTED TO NETWORK RELAY ON CORRESPONDING LED WILL GLOW
190 series diesel engineParts body * cam bearing bush 12VB.01.34 Screw compressor accessoriesLS10-30 oil filter element 250025-525 oil well cementAdditive BSG-2 16YT/YZ-14 Inhibitor Macromolecular Cations subpolymer coating inhibitor CHM Drilling rig top drive accessoriesDQ40/DQ50/DQ70 flushing pipe packing 1.04.02.01 Detroit diesel engine parts crank linkage * connecting rod bolts 16V149 23512064 50103-16-B Phase control relay E10922 Canrig 118375 GLYD RING: 10IN DIA PHD50 PHM TDS Remote Console Accessory FKQ6406 Lubricator QAL-4000 Drill pipe tong accessories ZQ203-100 rear box 02-18M PLUG, O-RING, .562-18 87196-6-S 91255 SEAL, HOUSING PLUG, EXT PIPE 53000-4-S Polyacrylamide compound ammonium salt YLAY NK400E engine*exhaust valve O-ring (rubber) S01-1229-01N Canrig DIAPHRAGM PROT ASSEMBLY 15K DIAPHRAGM PROT ASSEMBLY 15K E17-152 Electric control box FKDQ640-7 Explosion-proof switching amplifier Ifm-N0533A DC 24V Plug, Cavity (93667-M11) 93667-M11 Gear Sprocket , Drum type , Mud pump 3NB-1600GIICLZ12 BZ100 15 14 ND1250M306N BottomDisc*Cab Lifter Hydraulic Lines Inductive sensor-NCB10-30GM40-N0-15M 106283 Liquid end accessories TEM-CPT800C SMP-600 plunger 3 1/2" GT550E Chassis*Tiressteel ring Bulb: 48V 25/10W F/Hyster Fork Lift 2027396 Hydraulic tank accessories F-1300 Shear safety valve piston assembly Semicircle retaining ring BK-8-6A Logging tool accessories dipole acoustic logging tool KClog energy storage capacitor 1025486002 Falcon AIR BLADDER W31-20-901 VOLVOFM12 chassis*Cab jack hose Mechanical seal cover of the reverse rotation pump SB6Ã??8FJP SB68FJP0011 Accessories for cementing toolsFGFX insert head 339.7mm POWER SUPPLY\CANRIG\E12823 For 1275AC-681 General test mining tool turntable square tile ZP-275 Valve group 2 BK-T-2 Centrifugal fan YF 04 11kW explosion-proof Floating hoop FG ZX QZ 177.8mm Drill pipe clamp accessories ZQ203-100 Plug screw 0101-26M HH-0625NC-0225-GR8 Roller shaft accessories ZJ-40L Roller shaft assembly 3H106.28.20.00 109586-3 SHIM: BEARING RETAINER TOP DRIVE TDS-9S Spherical hinge P0900031AA MANIFOLD 109547-2 Elevator drill pipe elevator C DZ 109*109mm 2250 Hydraulic control system accessoriesFKQ6406GS master switch CE 0201-72 Winch oil pump drive shaftParts ZJ-32 winch oil pump CB-B63 Drill pipe tong accessories ZQ203-100 pressure cap 0101-21M pressure gauge YNT60 Y16100 Telescopic cylinder PIN ACTUATOR LINK 30172173 SHIM, RESERVOIR MOUNTING (.002) 110147-1 PNEUMATIC TUBE CLUTCH 600X250, FOR DRAWWORKS, MODEL: JC 70D, MAKE: HH, P/N: 1300008438 NB800G.05.15 Bolt M10x20 Liquid end fittings 45-21OFM600 Valve body 3102008950 H10409 DWYER Instruments Air Pressure Switch 1950-20-2F PDC bit 101.6mm M0864 Liner Seal QF36001-05.15 Filter Element: Hyd. 82749 OK019000701 OK TYPE PISTON SEAL SOCKET SET SCREW, 1/2" x 1/2" LONG SS, Part No: 6119, OEM Part no: 23731 Logging tool accessories four-arm caliper logging tool MAXIS-500 special sleeve tool SLB J97
Key Specifications/Special Features Technical data Type JLW-180 Current range 5-80A Time-current characteristic Definite time Rated voltage 220VAC,50/60Hz Measurement error 1% Protective functions Overcurrent,locked-rotor,phase loss, Additional functions power-on delay,auto reset Indicators LED indicating current,operation status Output contacts 1 C/O Contact capacity 5A 250VAC Dimensions (L x W x D) 70Ã?44Ã?98mm Mounting screw fixing -
Key Specifications/Special Features Technical data Type DZB Rated voltage 220VAC,380VAC,50/60HZ Current range 1-10A,5-50A,10-100A,80-200A200-400A,400-600A,600-800A Proective functions locked-rotor,overcurrent, undervurrent,phase loss,phase unbalance,overvoltage,undervoltage, Optional functions RS-485 communication port4-20mA analog output indicators LED indicating voltage,current,operation status Output contacts 1C/O for trip1C/O for alert Contact capacity 3A 380VAC Dimensions(HÃ?WÃ?Dï¼? 118Ã?54Ã?135mm Mounting Screw fixing Features Integrative structure Built-in LED and keypad afford a precise,digital setting Three-phase monitoring of short-circuit, locked-rotor,overcurrent, undervurrent, phase loss, phase unbalance,overvoltage,undervoltage Earth fault (should couple with ZCT) Fault recording RS-485 communication port (optional) 4-20 mA analog output (optional) 2 C/O output contacts, one for trip,one for alert Protective Functions Short-circuit Locked-rotor Overcurrent Undercurrent Phase loss Phase unbalance Overvoltage Undervoltage Typical Applications Pumps Fans Blowers Motors Compressors Approvals CE ROHS -
Baby products like baby clothes, baby diapers, toys, cosmetics, kitchen dishes, cutlery set, toiletry, clothes (used & new), bed sheet, quilt, home electronics, food, leather bags , wallet, shoes, belt,spices, home decor, artefacts, artificial jewellery, etc.
Product Usage The JWJXC-7200 type stepless enhanced contact relay is used as a power supply supervisory relay for the electric point machine in the power supply screen of a large station. Product function JWJXC-7200 type stepless enhanced contact relay is a commonly used electrical appliance in automatic control systems. It is used to connect and disconnect circuits, to issue control commands and reflect the status of equipment to form automatic control and remote control circuits. Applicable environment The applicable environment of the relay is: a) Ambient temperature: -40~+60; b) Relative humidity: not more than 90% (temperature +25C); c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m); d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken. product structure The electromagnetic system of the stepless strengthened contact relay is a stepless magnetic circuit with an enlarged size. The contact system is composed of two parts: a normal contact and a strong contact. The normal contact is the same as the stepless relay. Switches, switch start, etc.) designed contacts and isolator. Mechanical properties Number of contact groups: 4QJ; 2H Identification pin number: 14, 55; Strengthen the contact gap: not less than 7mm; Ordinary contact gap: not less than 4.5mm; Reinforce the gap of the support plate: generally not less than 0.35mm; Reinforce the gap of the support: the reinforcement is not less than 0.1-0.3mm;
Product Usage The JYJXC-135/220 type has a pole reinforced contact relay used as a switch control relay in a signal circuit. Applicable environment The applicable environment of the relay is: a) Ambient temperature: -40~+60; b) Relative humidity: not more than 90% (temperature +25C); c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m); d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken. Mechanical properties Number of contact groups: 2DF, 2DFJ; Identification pin number: 15, 54; Contact gap: ordinary contact is not less than 4.5mm; reinforced contact is not less than 7mm; Pallet gap: ordinary contact point is not less than 0.35mm; Ordinary contact pressure: the positioning contact is not less than 150mN; the reverse contact is not less than 150mN; Strengthen the contact pressure: the positioning contact is not less than 400mN; the reverse contact is not less than 400mN; Contact uniformity error: between ordinary contacts and ordinary contacts, between ordinary contacts and reinforced contacts, no more than 0.2mm, between reinforced contacts and reinforced contacts, no more than 0.1mm. Positioning or reverse position holding force is not less than 4N;
Product Introduction The JWJXC-160 type stepless enhanced contact relay is an important element in the interlocking equipment and the main equipment to ensure the safe operation of the system. The signal relay can control the switching, locking and unlocking of the switch and the opening and closing of the signal machine. Its reliability, availability, maintainability and the entire sauna line are the keys to the safety of railway transportation and operation services. The automatic control systems in various fields all use relays. Relays are widely used in railway signal technology, called signal relays, which are important components in railway signal technology. It plays an important role no matter as the core component of the relay signal system or as the interface component of the electronic or computer signal system. The reliability of the relay action directly affects the reliability and safety of the signal system. Product Usage The JWJXC-160 type stepless strengthened contact relay is used as a phase-failure supervision relay in the power supply screen. Applicable environment a) Ambient temperature: -40~+60; b) Relative humidity: not more than 90% (temperature +25C); c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m); d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken.
Product Introduction The JWJXC-135/135 stepless enhanced relay is an important element in the chain equipment and the main equipment to ensure the safe operation of the system. The signal relay can control the switching, locking and unlocking of the turnout, and the opening and closing of the signal machine. Its reliability, availability, maintainability and the entire sauna line are the keys to the safety of railway transportation and operation services. The automatic control systems in various fields all use relays. Relays are widely used in railway signal technology, called signal relays, which are important components in railway signal technology. It plays an important role no matter as the core component of the relay signal system or as the interface component of the electronic or computer signal system. The reliability of the relay action directly affects the reliability and safety of the signal system. Product function It is a commonly used electrical appliance in automatic control systems. It is used to connect and disconnect circuits, to issue control commands and reflect the status of equipment to form automatic control and remote control circuits. Product Usage JWJXC-135/135. Infinitely enhanced relays (hereinafter referred to as relays) are used as general relays in signal circuits. Applicable environment The applicable environment of the relay is: a) Ambient temperature: -40â??~+60â??; b) Relative humidity: not more than 90% (temperature +25�°C); c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m); d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken. Insulation withstand voltage Under the standard atmospheric conditions of the test, the insulation resistance of the relay should not be less than 100MQ. Under the condition that the air pressure is not lower than 86kPa (equivalent to the altitude below 1000m), the insulation withstand voltage of the relay should be able to withstand AC sine wave 50Hz, 2000V rms voltage, there should be no breakdown flashover after 1min, the voltage when repeating the test Should be 75% of the original test voltage value.
Product Usage The JZXC-H18 rectifier slow release relay is used as a filament supervisory relay in the electric centralized lighting circuit. Installation Precautions 1. When installing the relay, make sure that the insulation interval between the sockets is intact, the socket hanging spring is intact, and the socket identification pin is in the correct position and should not be missing. 2. Pay attention to the relative position between the relay and the socket when plugging in the relay to avoid damage to the relay or socket during plugging. 3. When repairing and replacing the relay, first remove the fixed relay spring, and then pull out the relay. Do not use excessive force or shake left and right when pulling it out, as it may damage the relay or socket. Applicable environment a) Ambient temperature: -40~+60; b) Relative humidity: not more than 90% (temperature +25); c) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m); d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken. Product electrical life The relay contact is connected to DC24V1A resistive load; its electrical life is 1106 times
Product Usage The JZJXC-100 type rectifier strengthened contact relay is used as a power supply supervisory relay for the indicator light in the power supply screen. Applicable environment a) Ambient temperature: -40~+60 b) Relative humidity: not more than 90% (temperature +25C); C) Air pressure: not less than 70kPa (equivalent to an altitude below 3000m); d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken. Mechanical properties Number of contact groups: 4QJ; 2H Identification pin number: 22, 32; Ordinary contact gap: not less than 1.3mm; Strengthen the contact gap: not less than 7mm; Ordinary pallet gap: not less than 0.35mm; Reinforce the gap of the support plate: not less than 0.1-0.3mm; Ordinary contact pressure: dynamic breaking contact is not less than 200mN; Strengthen the contact pressure: the moving and closing contact is not less than 600mN; Contact uniformity error: not more than 0.20mm. Electrical characteristics Rating: AC24V Magnetizing value: AC24V Release value: not less than AC4V Working value: not more than AC11V Coil resistance: 50 (1±10%) Q2 Coils are connected in series, connect 2, 3, use 1, 4
Product Introduction JZXC-16/16 is a dedicated multiplexer used to close and open the signal control circuit. It is an important part of railway signals. It plays an important role no matter as the core component of the relay signal system or as the interface component of the electronic or computer signal system. Product Features The JZXC-16/16 (formerly known as JZXC-16F) rectifier relay has a high return coefficient, which is used to automatically block the signal lighting circuit of the interval and solve the problem of large leakage current in long-distance power supply cables and unreliable release of the filament supervision relay. Features 1. The relay is a heavy elastic DC electromagnetic relay, which uses the principle of "constant gravity" to force the moving and closing contacts to open when the coil is de-energized. 2. It adopts silver-silver cadmium oxide contact, which has the characteristics of strong anti-adhesion and low contact resistance. 3. The magnetic circuit adopts electromagnetic pure iron material with small residual magnetism, and a stop piece is installed at the closed position of the armature and the iron core to ensure the minimum air gap of the magnetic circuit, prevent the magnetization of the ferromagnetic parts of the magnetic circuit, and ensure the reliable fall of the relay. 4. The front ring of the relay is a diode-enclosed short-circuit coil, without a rectifier unit, and the AC power supply is directly connected to the coil, which has a certain anti-lightning function. 5. The relay contact system consists of common contacts, with four groups of common contacts for switching on and off. 6. The relay should be used in conjunction with the isolation transformer to adjust the system current to ensure the reliable operation and release of the relay, and to ensure that the lamp terminal voltage meets the sp
Product Introduction The JZXC-H18F rectifier slow release relay is an important component in the interlocking equipment and the main equipment to ensure the safe operation of the system. The signal relay can control the switching, locking and unlocking of the turnout, and the opening and closing of the signal machine. Its reliability, availability, maintainability and the entire sauna line are the keys to the safety of railway transportation and operational services. The automatic control systems in various fields all use relays. Product Usage The JZXC-H18F rectifier slow release relay is used as a filament supervisory relay in the electric centralized lighting circuit. Features 1. The relay is a heavy elastic DC electromagnetic relay, which uses the principle of "constant gravity" to force the moving and closing contacts to open when the coil is de-energized. 2. The use of silver-silver oxidation requires contacts, which has the characteristics of strong anti-adhesion and low contact resistance. 3. The magnetic circuit adopts electromagnetic pure iron material with small residual magnetism, and installs the stop piece at the closed position of the armature and the iron core to ensure the minimum air gap of the magnetic circuit, prevent the ferromagnetic parts of the magnetic circuit from magnetization, and ensure the reliable fall of the relay. 4. The relay is a new product improved on the basis of the JZXC-H18 rectifier relay. The relay has no rectifier unit, and the AC power supply is directly connected to the coil, which has a certain anti-lightning function. The wiring terminal of the relay is exactly the same as the JZXC-H18 rectifier relay, so it is interchangeable, and there is no need to change the wiring on site. 5. The relay contact system consists of common contacts, with four groups of common contacts for switching on and off. 6. The relay should be used in conjunction with the isolation transformer to adjust the system current to ensure the reliable operation and release of the relay, and to ensure that the lamp terminal voltage meets the specified adjustment range.
Product Introduction JZXC-H0.14/0.14 rectifier slow release relay is the main equipment to ensure the safe operation of the system. The signal relay can control the switching of the turnout, lock and unlock the route, and control the opening and closing of the signal machine. Its reliability, availability, maintainability and the entire sauna line are the keys to the safety of railway transportation and operational services. The automatic control systems in various fields all use relays. Product Features The JZXC-H0.14/0.14 rectifier slow release relay is used as a filament conversion relay in the signal lighting circuit of a crossing. Applicable environment a) Ambient temperature: -40~+60; b) Relative humidity: not more than 90% (temperature +25); c) Air pressure: not less than 70kPa (equivalent to below 3000m above sea level); d) Vibration: the vibration frequency is not more than 15Hz, and the amplitude is not more than 0.45mm; e) Working position: horizontal; f) There should be no harmful gas causing explosion hazard around, and good dust-proof measures should be taken. Features