Electrcal conduit.
Mining equipments, hdpe pipes and geomembranes, industrial constructions, special vehicles. spanish ceramic tiles, electric cables and hdpe conduits. hotel equipment, as per kitchens, restaurants, industrial laundry, chemical products, irrigation material.
Conduit Bodies
PVC Flexible Conduit 7MM 10MM 16MM 20MM 25MM 32MM 40MM 50MM
Specifications: Nylon Meets UL-94HB Flammability Rating Color: Black . Temp Range: -40C to 150C. Features: Split design for easier installation and removal of wiring Cable protection for electrical wiring harnesses Flexible body facilitates your corner/elbow wiring
High flexibility and good bending, anti-oil, acid,corrosion, nonflammable, protection rating: IP 65 Temperature range -40C ~+140C Flame retardant rating : V0
Material: PVC Heat resistance :-25 - +75 Properties:PVC spiral hose with unbreakable core inside,long-lasting.Smooth wall inside.Different colors can be prdered.RoHs approval. Usage:For water,liquid,powder,granule transmission.Water supply drainage usage in construction etc. Available for 150 Series,160 Series,171-180 Series. Specification OD (mm) ID (mm) M/Roll 16 15.6 12 20 20 20.5 16 20 25 26.2 22 20 32 33.2 28 20 40 40 35 20
Specifications: Nylon Meets UL-94HB Flammability Rating Color: Black . Temp Range: -40�°C to 150�°C. Features: Split design for easier installation and removal of wiring Cable protection for electrical wiring harnesses Flexible body facilitates your corner/elbow wiring
Description: Nylon Corrugated Flexible Conduit Material: Nylon 66, Polythene, Polypropylene High flexibility and good bending, anti-oil, acid,corrosion, nonflammable, protection rating: IP 65 Temperature range4C ~+140C Flame retardant rating : V0
Description: 1. Material: Stainless Steel 2. Construction: Interlock 3. Surface finish:Coating, Coating+braiding grinding polishing 4. Coating material: Oil resistant, Abrasion resistant, Low temperature resistant 5. Can add PVC coating or wire braiding on the flexible metal tube to achieve effect of water proof and explosion proof Part No Normial Size Inner Diameter mm Outside Diameter mm O.D After PVC Coated Length Of Each Roll Interlocked Squarelocked M FM-10ISS 3/8" 12.5 15.7 18.0 16.6 50 FM-11ISS 1/2" 15.7 19.1 21.3 20.0 50 FM-12ISS 3/4" 20.8 24.3 26.7 25.5 50 FM-13ISS 1" 26.0 30.0 33.2 31.6 30 FM-14ISS 1-1/4" 35.0 40.0 42.2 42.0 30 FM-15ISS 1-1/2" 40.0 45.0 48.0 47.0 20 FM-16ISS 2" 51.0 56.0 59.6 59.0 10
Part No. Normial Size Inner Diameter Outside Diameter O.D After PVC Coated Length Of Each Roll mm mm Interlocked Squarelocked M SS-10 3/8" 12.5 15.7 18.0 16.6 50 SS-11 1/2" 15.7 19.1 21.3 20.0 50 SS-12 3/4" 20.8 24.3 26.7 25.5 50 SS-13 1" 26.0 30.0 33.2 31.6 30 SS-14 1-1/4" 35.0 40.0 42.2 42.0 30 SS-15 1-1/2" 40.0 45.0 48.0 47.0 20 SS-16 2" 51.0 56.0 59.6 59.0 10
EVT threaded conduit body for rigid conduit or IMC allows access for general inspection, maintenance and wire pulling. Conduit body saves time and money by eliminating costly bending of large conduits in order to change the directions of conduit runs. Its powder-coated finish and neoprene gasket ensure a weatherproof installation.
EMT is short for Electrical Metallic Tubing. EMT tube, also commonly called thin-wall, is a steel raceway of circular cross section, which is unthreaded, and nominally 10² long. EVT EMT conduit is UL listed with UL file number E476073. EMT electrical is manufactured according to UL 797, CSA C22.2 NO.83.1 and ANSI C80.3, Electrical Metallic Tubing â?? Steel. EMT Tubing is available in trade sizes 1/2 through 4. The steel conduit is galvanized both inside and outside for corrosion protection. EMT pipe is commonly installed by use of set-screw or compression type connectors and couplings.
Features: Galvanized steel, square-locked core with cord packing from 3/8" to 1-1/4", interlocked core from 1-1/2" to 4" to give additional strength to prevent unravelling Smooth wipe clean PVC jacketed Liquid-tight IP66/IP67 Good flexibility High mechanical strength Flame retardant UV protection moisture proof Resistance to most of chemicals, such as oil, acids and vapors, etc. Good Absorption of motion and vibration Cover does not winkle when bent Temperature range from -20oC to +105oC PVC color black (standard), grey or orange (made to order) Nickel plated brass fittings Galvanized malleable iron fittings Stainless steel fittings Applications: General industrial installations and wire protection Outdoor installation Machine tools Installations where liquid-tight is a requirement Special Applications: According to customer's samples and specifications, we can manufacture the LT type flexible conduit to suit special applications, such as wider temperature range, specific chemical resistance, etc. Specifications: Part No Nominal Size ISO (mm) Nominal Size US (inches) I.D. (mm) O.D. (mm) Min. Bend Radius (mm) Length (M/coil) LT-10B/G 16 3/8" 12.3 - 12.8 17.5 - 18.0 60 30 LT-11B/G 20 1/2" 15.8 - 16.3 20.8 - 21.3 80 30 LT-12B/G 25 3/4" 20.7 - 21.2 26.2 - 26.7 100 30 LT-13B/G 32 1" 26.2 - 26.8 32.7 - 33.4 150 30 LT-14B/G 40 1-1/4" 34.8 - 35.4 41.4 - 42.2 180 20 LT-15B/G 50 1-1/2" 40.1 - 40.6 47.4 - 48.3 200 20 LT-16B/G 63 2" 51.3 - 51.9 59.4 - 60.3 250 15 LT-17B/G 75 2-1/2" 63.0 - 63.6 72.1 - 73.0 300 10 LT-18B/G 90 3" 78.0 - 78.7 87.9 - 88.9 450 10 LT-19B/G 100 4" 101.6 - 102.6 113.2 - 114.3 600 5 Suitable fittings: LT type of fittings - IP66/67 (liquid-tight
Features: Galvanized steel core, Plastic jacketed. Light weight style, excellant flexibility and low fire hazard low smoke. Use for the place with poor ventilation or the environment needs more secure care or any narrow space for electrical wiring application. Temperature range from -10oC to +90oC Applications: General indutrial installations and wire protection Outdoor installation Machine tools Specifications: Part No Nominal Size ISO (mm) Nominal Size US (inches) I.D. (mm) O.D. (mm) Min. Bend Radius (mm) Length (M/coil) LFH-10 16 3/8" 12.3 - 12.6 16.5 - 16.8 60 50 LFH-11 20 1/2" 15.7 - 16.0 20.5 - 20.8 85 50 LFH-12 25 3/4" 19.7 - 20.0 25.3 - 25.6 100 50 LFH-13 32 1" 25.3 - 25.8 30.7 - 31.2 120 50 LFH-14 40 1-1/4" 32.3 - 32.8 38.5- 39.0 150 25 LFH-15 50 1-1/2" 38.30 - 38.8 45.7 - 46.2 180 25 LFH-16 63 2" 50.0 - 50.5 58.8 - 59.3 220 20 LFH-17 75 2-1/2" 62.5 - 63.2 73.5 - 74.0 310 10 LFH-18 90 3" 73.0 - 73.7 84.5 - 85.2 350 10 LFH-19 100 4" 97.50 - 98.5 109.5 - 110.5 410 5
Features: Galvanized steel, square-locked core PVC vacuum jacketed Light weight Water resistance Excellent flexibility Temperature range from -20oC to +105oC PVC color black (standard), grey or orange (made to order) Nickel plated brass fittings Galvanized malleable iron fittings Stainless steel fittings Applications: General industrial and commercial electrical wiring protection Machining centers and robotics any narrow space in static applications Special Applications: According to customer's samples and specifications, we can manufacture the VJ type flexible conduit to suit special applications, such as wider temperature range, flame retardant, etc. Specifications: Part No Nominal Size ISO (mm) Nominal Size US (inches) I.D. (mm) O.D. (mm) Min. Bend Radius (mm) Length (M/coil) VJ-10 16 3/8" 12.3 - 12.8 16.7 - 17.2 50 50 VJ-11 20 1/2" 15.8 - 16.3 20.2 - 20.7 65 50 VJ-12 25 3/4" 20.7 - 21.2 25.5 - 26.1 75 50 VJ-13 32 1" 26.0 - 26.6 31.6 - 32.2 100 50 VJ-14 40 1-1/4" 34.7 - 35.4 40.8 - 41.5 125 30 VJ-15 50 1-1/2" 40.0 - 40.6 46.6 - 47.2 150 30 VJ-16 63 2" 51.3 - 51.9 58.1 - 58.7 175 20 VJ-17 75 2-1/2" 63.0 - 63.6 71.8 - 72.4 200 10 VJ-18 90 3" 78.0 - 78.7 87.2 - 87.9 225 10 VJ-19 100 4" 101.6 - 102.6 111.2 - 112.3 275 5 Suitable fittings: VJ type of fittings - IP54 (non-liquid-tight) LT type of fittings - IP66 (liquid-tight)
Structure: Connector body with hexagonal wrench surface, thread ISO metric in accordance with EN60423 or thread NPT in accordance with ANS/ASME B1.20.1-1983, Comply with stands AS/NZS 2053. 8, hexagonal pressure nut, sealing ring and ferrule Material: Connector body - Galvanized die casting, zinc plated steel& malleable ironï¼? nickel plated brass, stainless steel. Hexagon pressure nut - Galvanized die casting zinc plated steel& malleable iron, nickel plated brass, stainless steel. Sealing ring - Nylon 66 Ferrule - Galvanized steel Features: Simple, one piece installation provides a quick and reliable liquid-tight seal IP rating from IP40 to IP66/67/68 in combination with the corresponding flexible conduits High mechanical strength Highly liquid-tight and dustproof Vibration and tension proof Inherently low fire hazard Covering of the conduit ends Available in straight, 45o and 90o bodies Available in ISO Metric and NPT, PF, PG, BSP etc. threads Applications: General industrial and commercial electrical wiring protection Machining centers and robotics any narrow space in static applications General wiring for OEM applications Low fire hazard applications Under flooring wiring in office buildings Machine tools Installations where liquid-tight is a requirement Outdoor installation Special Applications: According to customer's samples and specifications, we can manufacture special fittings for suit any type of flexible conduit applications. Specifications: 5/16"-2" Suitable flexible conduits: VJ type of vacuum jacketed flexible conduit LT type of liquid-tight flexible conduit FM type of flexible metallic conduit
Structure: Connector body with hexagonal wrench surface, thread ISO metric in accordance with EN60423 or thread NPT in accordance with ANS/ASME B1.20.1-1983, Comply with stands AS/NZS 2053. 8, hexagonal pressure nut, sealing ring and ferrule Material: Connector body - Galvanized die casting zinc plated steel& malleable ironï¼? nickel plated brass, stainless steel. Hexagon pressure nut - Galvanized die casting zinc plated steel& malleable iron nickel plated brass, stainless steel. Sealing ring - Nylon 66 Ferrule - Galvanized steel Features: Simple, one piece installation provides a quick and reliable liquid-tight seal IP rating from IP40 to IP66/67/68 in combination with the corresponding flexible conduits High mechanical strength Highly liquid-tight and dustproof Vibration and tension proof Inherently low fire hazard Covering of the conduit ends Temperature range from -40oC to +150oC Available in straight, 45o and 90o bodies Available in ISO Metric and NPT, PF, PG, BSP etc. threads Applications: General industrial and commercial electrical wiring protection Machining centers and robotics any narrow space in static applications General wiring for OEM applications Low fire hazard applications Under flooring wiring in office buildings Machine tools Installations where liquid-tight is a requirement Outdoor installation Special Applications: According to customer's samples and specifications, we can manufacture special fittings for suit any type of flexible conduit applications. Specifications: 5/16'-2" Suitable flexible conduits: VJ type of vacuum jacketed flexible conduit LT type of liquid-tight flexible conduit FM type of flexible metallic conduit
Quick Details Place of Origin:Liaoning, China Brand Name:JIANXI Model Number:JX-CL-0177 Material:UPVC Specification:10mm-63mm Length:4m or customized Thickness:0.8mm-2.0mm Standard:ISO9001:2008, ISO,JIS,GB,DN,BS,ASTM Color:White or customized Fitting:Coupling,elbow Shape:Round Packaging:ODM&OEM service Usage:Electric wire and cable protection Feature:Light weight,insulative,chemical resistance Connection:Glue Inner wall:Smooth Lifetime:50 years Supply Ability:1920 Ton/Tons per Month PVC-U electric conduit pipe Packaging & Delivery Packaging Details25 pieces in a bundle,each pcs with a plastic sleeve bag Customized package welcome Port Dalian Lead Time : Quantity(Meters) 1 - 5000 5001 - 10000 >10000 Est. Time(days) 5 10 To be negotiated PVC-U electric conduit pipe Length 4m/length Size 10/15/16/20/25/32/40/50/63(mm) Color Red,white,yellow,blue or customized Function Electric wire and cable protection Material PVC Connection Glue Advantages 1.Easy to identify and maintain, to avoid the risk of electric shock, to solve the problem of interference of the strong-weak wires. 2.PVC electrical conduit pipe has good insulation,the anti-current breakdown voltage is high, can withstand 25 KV voltage without breakdown. 3.Good Impact resistance, can be concealed in the concrete, will not be effected by the impact of pressure damage. 4.Good fire performance,pipe oxygen index is high, with flame retardancy, leaving the flame self-extinguishing moment. 5.Moisture proof, acid and alkali resistant. 6.The tubes do not have odors which insects and rats like, which will avoid being damaged by them. 7.Gently use your hands to bend with a spring insert, easy to use.