Vsm-12 series vacuum circuit breaker
1.With the voltage of 40.5kV is three-phase AC, 50/60 Hz indoor power distribution equipment. 2.It is used for switchgear KYN61-40.5(Z) 3.It is accordance with GB1984 AC HV vacuum circuit breaker standard. 4.It effectively reduces the dimensions of VCB, the overall arrangement is reasonable and simple,with aesthetic appearance. 5.It has high reliable with characteristics of long life and easy maintenance and free-maintenance for operating mechanism. 6.Meet the Five Preventions function.
1.Use spring energy storage. 2.Operating by two ways: manual or electric operation 3.The characteristics is accordance with GB1984-2003 AC High Voltage Circuit Breakers, JB3855-96 3.6~40.5kV indoor AC HV vacuum circuit breaker, relevant regulations of IEC62271-100 standard and the technical requirements of this product. 4.Use modular type operating mechanism and embedded pole The mechanical life is M2 and electrical life is E2
1. General VS1 12KV vacuum circuit breaker VCB HVD1-12(VS1-12) type indoor AC HV vacuum circuit breaker VCB (hereinafter referred to as circuit breaker) are suitable for 12kV air-insulated indoor switchgears, used as protection and control unit of power equipment of industrial& mining enterprise. Due to the super excellence, it is especially for location where requires the frequent operation of rated working current or multi breaking short circuit current. The circuit breaker adopts the integrated design of operating mechanism and circuit breaker body, servers as not only fixed installation, but also the handcart unit through equipping with a special propelling mechanism. 2. Service conditions 3.1 Environment temperature:-15degree~+40degree; 3.2 Environment humidity: Daily average relative humidity:
1. General HVD32 ZW32 This vacuum circuit breaker VCB is three-phase AC 50Hz, rated voltage 12 kV outdoor high voltage switch equipment. It is mainly used to opening(closing) load current, overload current and short-circuit current. It is suitable to protect or control the city or village electrical power distribution system. 2 . Main technical parameter Rated voltage: 12 kv 1 minute rated power frequency withstand voltage: Phase to Phase, to Ground 42 kv / Fracture 48 kv Rated current: 630A / 1250A Rated short circuit breaking current: 12.5KA, 16KA, 20KA / 25KA Rated short-circuit current (peak): 31.5KA, 40KA, 50KA / 63KA Rated peak withstand current: 31.5KA, 40KA, 50KA / 63KA 4s rated short time withstand current: 12.5KA, 16KA, 20KA / 25KA Rated operating sequence: O-0.3s-CO-180s-CO(Electric operation) Closing time: 30-60 ms Opening time: 20-40 ms Rated short circuit breaking current breaking times: 30 times Mechanical life: 10,000 times Secondary circuit 1 minute power frequency withstand voltage: 2000 v Energy storage motor rated power: 40 w Energy storage motor rated voltage V: DC220/110 Rated closing operation voltage v: DC220/110, AC220/110 Rated switching operation voltage v: DC220/110, AC220/110 Electric energy storage time: =8 s
TERASAKI TEMPOWER ACB TYPES: AT06, AT16, AT12, AT20, AT25, AT32, AT40. TERASAKI TEMPOWER ACB Type AGR-11B,21B,22B,31B Overcurrent Protective Device) Types: AR208S, AR212S, AR216S, AR220S, AR325S, AR332S, AR440S, AR440SB, AR212H AR216H, AR220H, AR316H, AR320H, AR325H, AR332H, AR420H, AR440H.
VACCUM CIRCUIT BREAKER ALL TYPE OF ABB VACCUM CIRCUIT BREAKER VD4 12.12.25 , VD4 12.12.40, VD4 07.12.25.... MANY MORE 11 KV , 33KV . VD4Medium voltage vacuum circuit-breaker12 kV - 1250...4000 A - 63 kA36/40.5 kV - 630...3150 A - 16...40 kAMedium Voltage Products The VD4 are a synthesis of the renownedtechnology in designing and constructing vacuuminterrupters embedded in resin poles, and ofexcellency in design, engineering and productionof medium voltage circuit-breakers.Embedding the interrupter in resin makes thecircuit-breaker poles particularly sturdy andprotects the interrupter against shocks, accumula-tion of dust and humidity.The vacuum interrupter houses the contacts andmakes up the interrupting chamber.
1. Introduction HVD7 33KV 36kv outdoor HV AC vacuum circuit breaker VCB has many visual advantages like reasonable design, fashionable appearance, high safety and reliability, simple maintenance, long electric life. It is the ideal upgraded products of 35KV outdoor oil circuit breakers. HVD7-40.5 vacuum circuit breaker is applicable for three-phase power system of AC 50HZ.It is used to make and break the load current ,overload current and short-circuit current. 2. Applicable environment 3.1The ambient temperature should be -30degree~ +40degree(-40degree in the frosty area); 3.2Altitude should not exceed 2000m(over 2000m is plateau type); 3.3The wind pressure should not exceed 700Pa(equal to wind speed 34m/s); 3.4Air pollution degree: 3,that of antifouling type:4; 3.5The installation site should be free from the fire, explosion, chemical corrosion and serious vibration. 1.Main technical parameters Rated voltage: 33kv 36KV 1 minute power frequency withstand voltage, dry test: 95 kv 1 minute power frequency withstand voltage, wet test: 80 kv Lightning impulse withstand voltage(peak value): 185 kv Rated current: 1600A / 2000A Rated short-circuit breaking current: 20KA, 25KA, 31.5KA Rated short-circuit making current(peak): 50KA, 63KA, 80KA Rated operating sequence: O-0.3s-CO-180s-CO Rated short-time withstand current: 20KA, 25KA, 31.5KA Rated peak withstand current: 50KA, 63KA, 80KA Rated short-circuit duration: 4 s Rated control voltage: AC220,110;DC220,110 Rated short-circuit breaking current break times: 20 times Full-break time:
Circuit breaker The circuit breaker mainly serves for protecting the circuits of ac 50 hz, 230vof single pole, 230v/400v of two poles and 400v of three or four poles from overload or short-circuit, and also for unfrequent making and breaking electrical apparatus and lighting circuit. Packed in export cartons
Standard rating: 1-20 ampere. Input power: 12 VDC /125 VAC / 250 VAC. Dielectric strength: 1500 VAC / 1 minute. Reset: manual push reset. Approvals: CSA, VDE, CSA C/US.
Terasaki, , square d, siemens, merlin gerin, qo, areva, sylvania, westinghouse, ge, murray, moeller, federal, schneider, zinsco, eta, cutler hammer, airpax, heinemann, klixon, hager. Miniature circuit breaker, air circuit breaker, electric circuit breaker, earth leakage circuit breaker, thermal magnetic circuit breaker, low voltage circuit breaker, molded case circuit breaker, vacuum circuit breaker, standard circuit breaker
Mini circuit breaker is suitable for wires of AC 50Hz, rated voltage of 400V,rated current of 32A(63A)D, with some protection functions such as leakage because of getting an electric shock, overload, short circuit, etc., and it can add over-voltage protection function according to users’ requirements. It mainly used in building lighting and protection of power distribution system. This product accords with IEC61009 and GB16917.1 standard.
DZ47-63 Series High Breaking Capacity Mini Breaker may be used in such occasions with AC 50 or 60Hz, rated working voltage of 415V or below and rated working current of 63A.It can servefor the illumination of office, residential housing and similar buildings and its distribution wires and protect the distribution circuit and equipment against overload and short-circuit.It can also be used for infrequent conversion of circuit under normal conditions. Rated current:1A, 3A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A Number of poles:1p, 2p, 3p, 4p Working voltage:From 240V to 415V DZ47LE Series Leakage Circuit Breaker may be used in the circuit with AC 50 or 60Hz, rated voltage of 230V or 400V and rated current of 63A or below. It can prevent personnel from electric shock, protect equipment against leakage and the circuit against overload and short-circuit It can also serve as infrequent conversion of circuit and infrequent startup operation of motor under normal conditions. Number of poles: 1p+n, 2p, 3p, 3p+n, 4p, Working voltage: 240V, 380/400V, 240V, 240/415V Rated current: 1A, 3A, 6A, 10A, 20A, 25A, 32A, 40A, 50A, 63A DZ20 series Moulded Case Circuit Breaker (hereafter refers to as circuit breaker) to be suitable to exchanges 50HZ. The nominal current from 16A to 1250A, fixed insulation voltage 660V, fixed working voltage 380V (400V) and in the below electric circuit makes the infrequent transformation and the electric motor infrequent starting using of. The circuit breaker has the overload, short-circuits and owes the voltage protective device, can protect the line and the power equipment is not damaged. This circuit breaker may be vertical the installment (namely vertical stroke to install), also may the level installment (namely horizontal attire). This circuit breaker carries out the standard: GB14048. 2 and IEC60947-2. Product model: Dz20-100, dz20-225, dz20-400, dz20-630, dz20-800, dz20-1250 Rated current: From 16A to 1250A Rated working voltage: 380V DZ30LE-32 Leakage Protector may be used in single-phase domicile circuit with AC 50 Hz or 60Hz, rated voltage of 220 V and rated current of 32 A. It can prevent personnel from electric shock, and protect vivil electric lines against overload and short-circuit. This product is of such characteristics as small volume, high breaking capacity and cutting off the live and zero lines at the same time. Rated current: 3A, 6A, 10A, 16A, 20A, 25A, 32A Number of poles: 1p+n Working voltage: 220V
Product Description Major Technical Data: Rated voltage: 12KV Rated frequency: 50HZ Rated current: 630A. 1250A. 1600A. 2000A. 2500A. 3150A. 4000A. 5000A. Rated short circuit current to be turn-off: 20KA. 31. 5KA. 40KA. 63KA. Mechanical lifetime of the operating device: í¦100, 000 times (5000A 63KA Mechanical lifetime: í¦60, 000 times) Mechanical lifetime: (630A-1250A) 20KA í¦50, 000 times. (1250A-3150A) 31. 5KA í¦50, 000 times (1250A-4000A) 40KA í¦30, 000 times (5000A) 63KA í¦30, 000 times Operating voltage for switch-on and switch-off: DC220V or AC220V. Model: ZN73A-12 Standard: ISO9001 CQC CCC.
DZ47-63 Miniature Circuit Breakers has small size, light weight, novel structure and excellent performance. The material of enclosure and inside plastically parts is fire resistance and withstand shocking. It is used in the circuit of 50/60Hz,rated voltage 230/400 V, rated current up to 100A as protection against overload and short circuit. It is also used as protection against frequent switchover.
Dimension for outline: Specification: 1.Rating currentú¦min.5Aú¼max.20A 2.Working pressureú¦min.12Vú¼max.250V 3.Double usage of DC and AC Application scopeú¦Used at the prote ction of compound outlet, power transformer and electrical motor. Current specificationú¦5A-15A125V UL
JD156(DZ47) series circuit breaker is used in Helmet distribution system or motor distribution system for protection overload and short-circuits in the system. The product is neoteric in structure, light in weight, reliable and excellent in performance. It has high breaking capacity, can trip quickly, and its case and items are adopted by high fire-resistant and shockproof plastics. The product, with long life, is mainly used in AC 50/60HZ single-pole 240 or two, three four-pole 415V circuit for overload and short-circuit protection as well as for unfrequented on íºCand-off switching electric equipment and Helmet circuit in normal case.
Circuit breaker Ns moulded case circuit breaker is one of the most advanced type breakers in the world, which adopts international advanced design and manufacture technology. They are suitable for short circuit and overload protection for circuit of ac 690v 50/60hz, rated current from 12.5a to 630a. It takes protect effect when mouse cage motors non-frequent start, breaking off working and protecting overload, short circuit and lacking voltage. Paper
Circuit breaker Foshan omell electrical equipment co., ltd are specializing in designing and manufacting electrica household including the circuit breaker, socket switch ect.We are acquaint with the market of south america, south asia.Mid east. We could be glad to provide our best service by offering you the excellent service and good quality goods.
Circuit breaker