Standard: IEC/EN61009-1 GB/T16917.1
Instantaneous trip type: B/C/D
The number of poles: 1P+N
Rated short circuit breaking capacity( Icn): 6kA
Release Type of Leakage Protection: Electronic
Rated working current In: 6-40A
Rated working voltage (Ue): AC 230V
Rated operating frequency: 50/60Hz
Rated insulation voltage (Ui): 500V
Rated residual operating current : 10/30/100/300mA
Life :4000 Times
Residual current type: A/AC
May-23-19
 
Standard: IEC/EN61009-1 GB/T16917.1
Instantaneous trip type: B/C/D
The number of poles: 1P+N
Rated short circuit breaking capacity (Icn): 6kA
Leakage protection trip type: Electronic /Electromagnetic
Rated working current (In): 6-40A
Rated working voltage (Ue): AC 230/400V
Rated operating frequency: 50/60Hz
Rated insulation voltage (Ui): 500V
Rated residual operating current : 10/30/100/300mA
Life: 4000 Times
Type of residual current : A/AC
May-23-19
 
Standard: IEC/EN61008-1 GB/T16916.1
Release Type of Leakage Protection: Electronic /Electromagnetic
The number of poles: 1P+N/3P+N
Rated limit short circuit breaking capacity (Inc): 6kA
Rated working current (In): 16-63A
Rated working voltage (Ue): AC 230/400V
Rated operating frequency: 50/60Hz
Rated impulse withstand voltage (Uimp): 4kV
Rated residual operating current : 10/30/100/300mA
Mechanical/electrical life: 4000/4000 Times
Type of residual current: A/AC
May-23-19
 
Standard: IEC/EN61009-1 GB/T16917.1
Instantaneous trip type: B/C/D
The number of poles: 1P+N/3P+N
Rated short circuit breaking capacity (Icn): 6kA
Leakage protection trip type: Electronic
Rated working current (In): 6-40A
Rated working voltage (Ue): AC 230/400V
Rated operating frequency: 50/60Hz
Rated insulation voltage (Ui): 500V
Rated residual operating current : 10/30/100/300mA
Life: 4000 Times
Type of residual current: A/AC
May-23-19
 
Standard: IEC/EN61009-1 GB/T16917.1
Instantaneous trip type: B/C/D
The number of poles: 1P+N
Rated short circuit breaking capacity (Icn): 4.5kA
Release Type of Leakage Protection: Electronic
Rated working current (In): 6-40A
Rated working voltage (Ue): AC 230V
Rated operating frequency: 50/60Hz
Rated insulation voltage (Ui): 500V
Rated residual operating current : 10/30/100/300mA
Life: 4000 Times
Residual current type: A/AC
60238 Moulded Case Circuit Breaker Suppliers
Short on time? Let Moulded Case Circuit Breaker sellers contact you.
May-23-19
 
Standard: IEC/EN61009-1 GB/T16917.1
Instantaneous trip type: B/C/D
The number of poles: 1P+N
Rated short circuit breaking capacity (Icn): 10kA
Release Type of Leakage Protection: Electronic /Electromagnetic
Rated working current (In): 6-40A
Rated working voltage (Ue): AC 230V
Rated operating frequency: 50/60Hz
Rated insulation voltage (Ui): 500V
Rated residual operating current : 10/30/100/300mA
Life: 4000 Times
Residual current type: A/AC
May-23-19
 
Standard: IEC/EN61009-1 GB/T16917.1
Instantaneous trip type: B/C/D
The number of poles: 1P+N
Rated short circuit breaking capacity (Icn): 6kA
Release Type of Leakage Protection: Electronic
Rated working current (In): 6-40A
Rated working voltage (Ue): AC 230V
Rated operating frequency: 50/60Hz
Rated insulation voltage (Ui): 500V
Rated residual operating current : 10/30/100/300mA
Life: 4000 Times
Residual current type: A/AC
May-23-19
 
Standard: IEC/EN61009-1 GB/T16917.1
Instantaneous trip type: B/C/D
The number of poles: 1P+N
Rated short circuit breaking capacity Icn: 4.5kA
Release Type of Leakage Protection: Electronic
Rated working current (In): 6-32A
Rated working voltage (Ue): AC 230V
Rated operating frequency: 50/60Hz
Rated insulation voltage (Ui): 500V
Rated residual operating current : 10/30/100/300mA
Life: 4000 Times
Residual current type: A/AC
May-23-19
 
Standard: IEC/EN61008-1 GB/T16916.1
Release Type of Leakage Protection: Electronic /Electromagnetic
The number of poles: 1P+N/3P+N
Rated limit short circuit breaking capacity (Inc): 6kA
Rated working current (In): 16-63A
Rated working voltage (Ue): AC 230/400V
Rated operating frequency: 50/60Hz
Rated impulse withstand voltage (Uimp): 4kV
Rated residual operating current : 10/30/100/300mA
Mechanical/electrical life: 4000/4000 Times
Type of residual current: A/AC
May-23-19
 
Standard: IEC/EN61009-1 GB/T16917.1
Instantaneous trip type: B/C/D
The number of poles: 1P+N/3P+N
Rated short circuit breaking capacity (Icn): 6kA
Leakage protection trip type: Electronic
Rated working current (In): 6-63A
Rated working voltage (Ue): AC 230/400V
Rated operating frequency: 50/60Hz
Rated insulation voltage (Ui): 500V
Rated residual operating current : 10/30/100/300mA
Life: 4000 Times
Type of residual current : A/AC
May-23-19
 
Standard: IEC/EN61008-1 GB/T16916.1
Release Type of Leakage Protection: Electronic /Electromagnetic
The number of poles: 1P+N/3P+N
Rated limit short circuit breaking capacity (Inc): 6kA
Rated working current In: 16-63A (can be extended to 125A)
Rated working voltage (Ue): AC 230/400V
Rated operating frequency: 50/60Hz
Rated impulse withstand voltage (Uimp): 4kV
Rated residual operating current : 10/30/100/300mA
Mechanical/electrical life: 4000/4000 Times
Type of residual current: A/AC
May-23-19
 
Standard: IEC/EN61008-1 GB/T16916.1
Release Type of Leakage Protection: Electronic /Electromagnetic
The number of poles: 1P+N/3P+N
Rated limit short circuit breaking capacity (Inc): 6kA
Rated working current (In): 16-63A
Rated working voltage (Ue): AC 230/400V
Rated operating frequency: 50/60Hz
Rated impulse withstand voltage (Uimp): 4kV
Rated residual operating current : 10/30/100/300mA
Mechanical/electrical life: 4000/4000 Times
Type of residual current: A/AC
May-21-19
 
Standard: IEC/EN61009-1 GB/T16917.1
Instantaneous trip type: B/C/D
The number of poles: 1P+N
Rated short circuit breaking capacity: Icn 6kA
Release Type of Leakage Protection: Electronic
Rated working current : In 6-40A
Rated working voltage : Ue AC 230V
Rated operating frequency : 50/60Hz
Rated insulation voltage Ui : 500V
Rated residual operating current I â?³ n 10/30/100/300 mA
Life: 4000 Times
Residual current type: A/AC
Mar-08-22
 
moulded case circuit breaker with rated insulation voltage 800V, applied in the power system of AC50(60)Hz, rated voltage 690V and below, rated current 1250A and below as the transfer not frequently. The circuit breaker has the protection devices of over load, short circuit and under voltage ,it can protect the circuit and power equipment from broken.

The mccb can be sorted to C type (basic),L type (standard),M type (high breaking), H type(higher breaking) according to its rated limit short circuit breaking capacity.

The mccb has the features small volume, breaking capacity high, electric arcing short ,anti-vibration. It is the ideal product for application in land and ship.

The installation can be vertical or level and the standard conforms to IEC60947-2 and GB14048.2
VERIFIED
Jun-09-21

C&s Mccb

$41.00
MOQ: Not Specified
Supplier From Anand, Gujarat, India
 
C&S MCCB , Moulded Case Circuit Breakers - Winbreak2
RANGE : Rating: 16A~1600A , Poles: 3P & 4P.

Moulded Case Circuit Breakers - Winbreak
RANGE: Rating: 15A ~ 1200A , Poles: 2P, 3P & 4P

Moulded Case Circuit Breakers - WiNbreak1
RANGE : Rating: 16A ~ 400A in 3P & 4P
Rating: 16A ~ 200A in single pole
May-25-09

Circuit Breaker

$0.10 - $5.00
MOQ: Not Specified
 
DZ47-63 Series High Breaking Capacity Mini Breaker may be used in such occasions with AC 50 or 60Hz, rated working voltage of 415V or below and rated working current of 63A.It can servefor the illumination of office, residential housing and similar buildings and its distribution wires and protect the distribution circuit and equipment against overload and short-circuit.It can also be used for infrequent conversion of circuit under normal conditions.

Rated current:1A, 3A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A
Number of poles:1p, 2p, 3p, 4p
Working voltage:From 240V to 415V

DZ47LE Series Leakage Circuit Breaker may be used in the circuit with AC 50 or 60Hz, rated voltage of 230V or 400V and rated current of 63A or below. It can prevent personnel from electric shock, protect equipment against leakage and the circuit against overload and short-circuit It can also serve as infrequent conversion of circuit and infrequent startup operation of motor under normal conditions.

Number of poles: 1p+n, 2p, 3p, 3p+n, 4p,
Working voltage: 240V, 380/400V, 240V, 240/415V
Rated current: 1A, 3A, 6A, 10A, 20A, 25A, 32A, 40A, 50A, 63A

DZ20 series Moulded Case Circuit Breaker (hereafter refers to as circuit breaker) to be suitable to exchanges 50HZ. The nominal current from 16A to 1250A, fixed insulation voltage 660V, fixed working voltage 380V (400V) and in the below electric circuit makes the infrequent transformation and the electric motor infrequent starting using of. The circuit breaker has the overload, short-circuits and owes the voltage protective device, can protect the line and the power equipment is not damaged.

This circuit breaker may be vertical the installment (namely vertical stroke to install), also may the level installment (namely horizontal attire).

This circuit breaker carries out the standard: GB14048. 2 and IEC60947-2.

Product model: Dz20-100, dz20-225, dz20-400, dz20-630, dz20-800, dz20-1250
Rated current: From 16A to 1250A
Rated working voltage: 380V

DZ30LE-32 Leakage Protector may be used in single-phase domicile circuit with AC 50 Hz or 60Hz, rated voltage of 220 V and rated current of 32 A. It can prevent personnel from electric shock, and protect vivil electric lines against overload and short-circuit. This product is of such characteristics as small volume, high breaking capacity and cutting off the live and zero lines at the same time.

Rated current: 3A, 6A, 10A, 16A, 20A, 25A, 32A
Number of poles: 1p+n
Working voltage: 220V
Aug-12-13
Supplier From Wenzhou, Zhejiang, China
 
Specifications

1.Om1 circuit breaker
2.Used for circuit of a.C. 50hz
3.Rated operating voltage ac 400v
4.Iec60947-2 standard

Om1 moulded case circuit breaker (mccb)

Application:
Om1 series moulded case circuit breaker is one of products developed and manufactured by adopting international advanced technology. It is supplied with rated insulating voltage 800vand used for circuit of a.C. 50hz, rated operating voltage ac 400v (or below), rated operating current up to 800a for infrequent changing over and starting of the motors.The products con-forms to iec60947-2 standard.


Ccc, ce, sgs.Ul
Jan-03-20
Supplier From South Korea (Republic Of Korea)
Dec-19-03
Supplier From Hangzhou, Zhejiang, China
Mar-21-16
Supplier From Wenzhou, China
60238 Moulded Case Circuit Breaker Suppliers
Short on time? Let Moulded Case Circuit Breaker sellers contact you.