FEATURES Most cost-effective Faster installation Safe and easy installations High accuracy 0.5 Holding wire diameter: 32mm Ratio ranging from 60/1A to 600/5A CE, UL PARAMETERS Technical parameters Standards IEC/EN60044-1 & IEC61010-1 & IEC61869-2&ANSI C57.13 Ratio 400: 5 or 200:5 , customized Nominal input current Primary current 100A/150A/200A/300A/400A/500A/600A Overload withstand 1.2 times rated current continuously Accuracy 0.2%, 0.5 %, 1%/60Hz System Voltage 720V(0.72kV) Output signal 1A or 5A 333mV AC or 100mV-2V optional Burden 2.5VA Frequency range 40 Hz-500 Hz Dielectric strength 3KV 50Hz/60Hz at 1 minute Output Standard 2.5 meter cable Max. jaw opening 32 mm Mechanical parameters Dimensions (DH) (mm) 110mm130mm 41mm Weight(g) 700 Operating conditions Operating temperature -25 C to +55 C Relative Humidity 0-85% non-condensing Altitude
Standards IEC60044-1; IEC 61869-2; ANSI C57.13; NTC 2205; GB1208-2006 Rated primary current 300-600A Rated load 10VA Rated frequency 50Hz or 60Hz Rated secondary current 5A or 1A Rated short-time thermal current 40kA, 1S Rated continuous thermal current 120%I1n Secondary winding power-frequency voltage 3kV, 1min Instrument security factor FS 10 Mechanical parameters Dimensions (WDH) (mm) 50x110x32 Weight (kg) 1 Operating conditions Operating temperature -35C to +55C Daily average temp
Technical parameters Standards IEC60044-1; IEC 61869-2; ANSI C57.13; NTC 2205; GB1208-2006 Rated primary current 20-600A Rated load 25VA Rated frequency 50Hz or 60Hz Rated secondary current 5A or 1A Rated short-time thermal current 40kA, 1S Rated continuous thermal current 120%I1n Secondary winding power-frequency voltage 3kV, 1min Instrument security factor FSâ?¤10 Mechanical parameters Dimensions (WDH) (mm) 50x110x105 Weight (kg) 3.1 Operating conditions Operating temperature -35C to +55C Daily average temp
We are supplier and exporter of Ferro Silicon. Ferro silicon Specs: Si:75%min. and Si:72%min. C:0.2%max. S:0.02%max. P:0.04%max. Al:2.0%max.1.5%max.and 1.0%max .Commodity: Ferro Silicon Low Al Specs: Si:75%min. C:0.2%max. S:0.02%max. P:0.04%max.Al:0.1%max.0.3%max.and0.5%max. In 1mt plastic woven bags. Ferro Silicon Ferro Silicon has a melting point of 1200�?�°C to 1250�?�°C with a boiling point of 2355�?�°C and Ferro Silicon contains about 2% of calcium and alluminium. Ferro Silicon, as an additive to the production process of ferrous metals, will impart several desirable properties upon the resultant alloy. Some of the primary benefits of adding Ferro Silicon to an alloy is to improve the corrosion resistant properties of the new compound, as well as to add to the high temperature heat- resistance properties of the new alloy, for example, in the production of silicon steel for use in transformer cores.
Split core Current transformer: 1) HK-23: Inner hole 20*30mm, Ratio: 100/5A, 150/5A, 200/5A, 250/5A, 300/5A, 400/5A 2) HK-58: Inner hole 50*80mm, Ratio: 250/5A, 300/5A, 400/5A, 500/5A, 600/5A, 750/5A, 800/5A, 1000/5A 3) HK-812: Inner hole 80*120mm, Ratio: 500/5A, 600/5A, 750/5A, 800/5A, 1000/5A, 1200/5A, 1250/5A, 1500/5A, 1600/5A, 2000/5A, 2500/5A, 3000/5A, 4000/5A 4) HK-816: Inner hole 80*160mm, Ratio: 1000/5A, 1200/5A, 1500/5A, 1600/5A, 2000/5A, 2500/5A, 3000/5A, 4000/5A, 5000/5A, 6000/5A, 7500/5A, 8000/5A
1:The structure of the self-locking, safe, easy to install, portable 2:Wide inner window, allowing clamping of big cables or bus-bars 3:Wide range of sizes to accommodate all the existing installations 4:Isolated plastic case recognized according to UL94-V0 5:Wires plugs,Audio plugs,Power plugs and so on five kinds of plugs 1:Current measurement, monitoring and protection for electrical wiring and equipment. 2:Current and power measurement for electric motors, lighting, aircompressor,heating and ventilation system, air-condition equipment and automation – control system. 3:Current, power and energy monitoring device. 4:Relay protection device.
The initial magnetic permeability and temperature stability between nanocrystalline soft magnet alloy and permalloy are similar. Under the same conditions of core sizes and characteristics, the weight of the former is much lighter (about 1/3 lighter), cost much lower. Applications: Electronic kwh meter Precise power meter Overcurrent protection in mechanical control apparatus Current control in industrial automation Good thermal stability Paper ctn
Main Feature: 1.Small size, low cost 2.High secondary turns 3.Secure locking hinge Model No.: MEWOI-CT23CT55CT58,CT88,CT410,CT610,CT816 Name: MEWOI-CT23CT55CT58,CT88,CT410,CT610,CT816 Split Core Current Sensor/Transformer SPECIFICATION Model Number: MEWOI-CT23CT55CT58,CT88,CT410,CT610,CT812,CT816 Apply to: GB28040 and IEC68169 Rated Voltage : 0.66/0.72KVrms Primary Current input : 100-5000Arms Secondary Output: 5Arms/1Arms Insulaiton Strength: 2KVac/min Insulation Resistance DC500V/100MΩ Working frequency 50-400Hz Operating Temperature-25to 50 Storage Temperature -30to 70 MEWOI-CT23CT55CT58,CT88,CT410,CT610,CT812,CT816 series of split type current transformers are mainly used in industrial urban network, agricultural network transformation project, easy installation, no need to disassemble any cable or bus-bar circuit, and support electrified operation, not affect the normal power consumption of users, save a lot of manpower and material resources for the user transformation project, and improve the efficiency of transformation. This series current transformer can be used in conjunction with relay protection, measurement and metering devices. At present, it is widely used in transformation projects such as semiconductor industry.
We have 3units of MTU Serious 4000 R03s from the Navy MTU Series 4000 R03 The specification for the MTU 20V538TB91 engine Type :20V538TB91 Rated Power: 3589hp (2640kW) Number of Cylinders :20 Speed at Rated Power :1950 RPM Bore/Stroke:185mm x 20mm (7.28 in x 7.87 in) Displacement:107.5 liter (6550 cu.in) Fuel Consumption: 1150 liter/hour (303.9 gallons/hour) Dimensions (L x W x H) 3790 x 1640 x 2505mm (14575kg/32132 lbs) Cooling system: MTU-split circuit coolant system with electronically controlled thermostats And a coolant to raw water plate core heat exchanger
Features: High saturate magnetic induction bs High initial permeabilityhigh linearity high accuracylow phase and amplitude error for ct Good temperature stability-55~130 Applying for transformer class grade: 0.5-0.05 class 2applications High precision current and voltage transformer Current leakage circuit breakers Electronic watt hour meter Precision power meter Current control in automation industry
Application Current transformers can convert large currents into small currents in a certain proportion, thereby providing current for various instruments and relay protection, and isolating the secondary system from high voltage. This way can protect workers and equipment, can also simplifies and standardizes the manufacture of meters and relays. Advantagesï¼? In order to improve the current transformer precision, has to improve the magnetic permeability of current transformer cores. Compared with silicon steel core, nanocrystalline core has better magnetic permeability. Compared with permalloy core, the cost of nano core is lower. So nano core is the ideal material of current transformer. It is widely used in precision current transformer, zero sequence current transformer, medium and high frequency transformer.
Application Current transformers can convert large currents into small currents in a certain proportion, thereby providing current for various instruments and relay protection, and isolating the secondary system from high voltage. This way can protect workers and equipment, can also simplifies and standardizes the manufacture of meters and relays. Advantages In order to improve the current transformer precision, has to improve the magnetic permeability of current transformer cores. Compared with silicon steel core, nanocrystalline core has better magnetic permeability. Compared with permalloy core, the cost of nano core is lower. So nano core is the ideal material of current transformer. It is widely used in precision current transformer, zero sequence current transformer, medium and high frequency transformer.
Type: Non-Gmo Fit For Human Consumption MOQ 12,500MT / SBLC DLC 1 Year CIF Contract Payment At Destination Port SWIFT POP ICPO MT799 MT700 Quality: Standard Export Quality Origin Brazil OR USA Moisture: 13.5% Maximum Max Splits: 20% Protein: 35% Basis, 34% Minimum Max Color: 2% Oil Content: 18.5% Basis, 18.0% Minimum Test Weight: 54 Pounds/Min/Bushel Total Damaged Kernels: 3% Max Foreign Matter: 2% Max Radiation: Normal Crop: 2020 Or Current Heat Damaged Kernels: 0.50% Maximum.
Thickness: 15- 20mm Application : Interior, Exterior, Projects This sought-after granite design is inspired by our magnificent milky-way galaxy, It has a deep black base speckled with white and brown spots. This classic granite design can transform any residential or commercial space. Our galaxy black can enhance any space such as patios, bathroom floors, flooring, staircases, pavements and kitchen tops to mention a few. The thickness of this granite design ranges from 15 mm to 30 mm and is available in various finishes such as honed, polished, matte, leather, litchi and 3d. It can make any outdoor or indoor space visually appealing with its intriguing texture along with several functional properties such as being water-resistant, stain-resistant, heat resistant, easy to clean and hard to wear out. All of this makes our galaxy black granite a very popular and commercially favorite among others.
.Power quality monitoring .Power instrument and meter .Distributed measurement systems .Measurement of current of power supplyequipment below 10KV .Microcomputer protection Character: .Use high permeability silicon steel . Outdoor , water proof IP65,dust proof .Secondary winding employ with high qualityepoxy resin casting in plastic case which is flame retardant, anti-moisture,stable performance .Split core and full sealed ,use sealedwater proof cable as secondary leading wire
Quick Details Place of Origin: Beijing, China (Mainland) Brand Name: HYLITON POWER Model Number: LDZC-10/24/35kV Usage: Current Phase: Single/Three Coil Structure: Toroidal Coil Number: Autotransformer Rated frequency: 50Hz or 60Hz Rated secondary current: 5A or 1A Rated short-time thermal current: 40kA,1s Rated continuous thermal current: 120%In Continuous power-frequency voltage: 3kV , 1min Instrument security factor: FSâ?¤10
Morning Bright Crop is dedicated to providing the highest grade premium Peanuts/Groundnuts anywhere in the world, at the most competitive market prices. We currently are able to supply both Whole Peanuts as well as Peanut Kernels depending on your needs/requirements. With a monthly capacity of over 1000 metric tonnes and a minimum order of 1 container (20 metric tons), we are confident that we can meet your Peanuts/Groundnuts sourcing needs. Our facility is equipped to offer packaging options of 25kg and 50kg bags, ensuring that your product is delivered in excellent condition. -COLOR Red -AFLATOXIN Free -DAMAGES & SPLITS 3% Max -FOREIGN MATTER 5% Max -HUMIDITY 5% Max -MOISTURE 7% Max -OIL CONTENT 45% Min -FFA 2% Max
The CT can be mounted to existing panels, such as control centers or load centers, to measure or monitor wattage. These CTs can be mounted without removing existing cables for easier installation.