We manufacture Automobile Industry related temperature sensors. In BULK: 1) Automatic transmission (position sensor and ATF temperature sensor) 2) Motor temperature sensor 3)Battery temperature sensor/ current senso 4) Exhaust gas temperature sensor (recirculation) 5) Ambient air temperature sensor 6) Steering wheel and seat heat temperature sensor 7) Air duct temperature sensor
Basic Parameters Dimensions: 201 x 99 x 35 mm Weight: 333g Adapter Input: AC 100 ~ 240 V Output: DC 24V 2.65A Display mode Segment LCD with white backlight + LED in red and green Function Introduction Charge Active, pre-charge, constant current and constant voltages are the stages of charging mode. The initial charging mode depends on the battery voltage, so active and pre-charge don't happen to every batteries. For charging mode and current, please refer to the paragraphs of charging mode and charging current on page 2 & 3. Tester will stop charging if one of the conditions below was met. 1) Remaining capacity 99% & current intensity = 0 2) Remaining capacity = full charge capacity 3) Current intensity reduce to end charge current when constant voltage charge 4) Remaining capacity reach up the set value Discharge Constant current discharge for double loads Inner load: 0 ~ 1000mA, adjustable continuously via Battery Manager External load: 0mA, 500mA, 1000mA, 1500mA, 2000mA, five gears with dip switches offered Tester will stop discharging if one of the conditions below is met. 1) Remaining capacity set value 2) Voltage set value 3) Current intensity reduce to zero Remarks: Many batteries can not measure exact current intensity, which cause an else current value appears after you set a value. However, the actual discharging current is the same with your set value. Test Testing time is 12 seconds and the purpose is to check both the charging and discharging performances. After finishing test, LED flickers with green color and LCD reports the test result. Normal: Test OK Shown on LCD Abnormal: Test NG Shown on LCD Possible causes and solutions for the abnormal: 1) Cause: battery voltage is too low to discharge Solution: try to charge the battery to raise voltage 2) Cause: remaining capacity is too full to charge any more Solution: try to discharge the battery to reduce the remaining capacity 3) Bad contact of battery connecting wires 4) Damaged battery 5) Tester trouble Capacity Correction The battery capacity value in the battery management chip will different from the actual capacity after a battery goes through many recycling cycles. It will affect the use of the battery when the difference reaches a certain degree. Capacity correction is to deep discharge a battery and then fully charge, which will correct the capacity value in the battery management chip. Remarks: Discharging current can be set via Battery Manager. Deep discharge will cause a battery losing communication with tester, so battery dropping phenomenon may happen in the discharging process if the end capacity and voltage are set too low. In such a case, active charge will make the battery work again. 50% Capacity CD50%: charge firstly, and then discharge to 50% capacity DC50%: discharge firstly, and then charge to 50% capacity Online Functions Tester can be connected with master machine via a USB port. Users can monitor, control and set parameters via Battery Manager software in the master machine. Monitoring Battery information can be monitored via three windows. 1. Home screen Battery bar and brief information can be read on home screen. 2. Battery detail information window Show smart battery data in real time and the data can be saved and printed in image format. 3. Battery graph window Voltage, current and capacity are traced in curves. Control Battery Manager can control slave machine completely. Right-click menu on the battery bar includes the related commands. Attention All the functions of charge, discharge, capacity correction and 50% capacity are comply with the charging discharging conditions, which are showed on function introduction paragraph in page 4 & 5, so parameters should be set reasonably. Especially, deep discharge will cause a battery losing communication with tester. Others 1. Active cooling 2. Active batteries of zero voltage When a battery is deep discharged, the discharge protection circuit will start up and the voltage in the battery connector will become zero voltage. In this case, an appropriate voltage should be supplied to active the battery. 3. Battery identification Battery information can be read from battery management chip after establishing communication. 4. Intelligent protection Against over-current, over-voltage, over-charge, over-heat and short circuit. 5. Fan Discharging mode: fan startup Other modes: fan startup when temperature above 48 Fan stop working when temperature below 40 6. Trouble alarm LED flickers in red color and current command stops when one of the conditions below happen. 1). There is not current for around 50 seconds when charge. 2). There is not current for around 25 seconds when discharge. 3). Charging time is above 8.8 hours. 4). Discharging time is above 9.9 hours. 5). Suitable for almost all laptop batteries, above 95% Structure Accessories 1).1 * adapter 2). 1 * USB cord 3). 1 * CD 4). 13 * connectors 5). 10 * cables 6). 10 * jumpers 7). 1 * loader Standard Export Carton
We are proud to say that for the first time in India, we are launching Battery temperature sensors for commercial purposes. The specialty of the sensor is that we can measure the in situ temperature. So far, the widely popular technique is to monitor the battery temperature by placing a sensor adjacent to it. As expected, the accuracy of this method is not up to the mark. Now with the advent of Arcotherm's unique sensors, more accurate values can be obtained. Currently, we are exporting these to the European market.
Our Eddy Current Separators are prominently used in industries as a separator of nonferrous metals from mixed wastes and other mainstream materials More specifically it purely separates metals like aluminium copper brass and much more from the product stream municipal solid waste recycling lines scrap residues and other project lines Our eddy masterclass eccentric rotor is designed to ensure the full efficiency of eddy current effects on the rotor shell which separates about 97 of the total nonferrous impurities Application Wise Capacity Applications Capacity Per Meter Width Pet Flakes 1600kg Glass Cullet 10 TonsHR Wood Chip 5 TonsHR Beverage Cains 3 TonHR Rubber Scrap 800 KGHR Aluminium Scrap 2 TonsHR Salient Features Tensile structure with a very stable foundation Zero loss of valuable material Low on maintenance Quality deliverance and protection for further equipment High yields of nonferrous metals recovery Applications 98 recovery of aluminium cans from commingled recyclables Stainless steel copper aluminium and brass from shredder residue and fluff Nonferrous metal recovery in refuse streams and ash streams in WastetoEnergy facilities Separation of nonferrous chips Aluminium scrap recovery in foundry sand reclamation Glass cullet recycling Wood waste processing Aluminium extrusion recycling Eddy Current Separator is used for Aluminium Scrap Recycling Rubber Scrap Recycling Ewaste Recycling MSW Municipal Solid Waste Glass Cullet Recycling Aluminium Scrap Recycling Pet Flakes Recycling Wire Scrap Recycling Plastic Waste Recycling PVC Scrap Recycling Zorba
Eddy current sorting machine Inspection items: 1. Recognition of hardness difference , accurancy 2 HRC ( +/- 1HRC) 2. Recognition of different metal material mixed. 3. Same size with similar material parts mixed 4. With/without high frequency harding difference. 5. Dimension measurement of appearance by laser or optic ( extra optional) 6. crack sorting (extra optional).
Nominal Current(RMS):200/400/800/1000/1200/2000A Vout@Ipn:+_4.000V Measuring Range:0~+_3000A Supply Voltage DC:+-12-15V Accurancy@Ipn,+25degree Celsius:less than +_0.5% Mounting(mm):12.5*41.0
Nominal Current(RMS):25/50/75/100A Vout@Ipn:+_25/50V Measuring Range:0~+_150A Supply Voltage DC:+-12-15V Accurancy@Ipn,+25degree Celsius:less than +_0.5% Mounting(mm):7.0*12.7  * Closed- loop                                        * Supply voltage: DC +-12~15V  * Capable measurement of currents: DC, AC,pulse with galvanic isolation between primary circuit and secondary circuit.
FEATURES Suitable for 5A, 10A cable online measurement. Holding wire diameter: 8mm Dimension: 42.6mm 122.5mm 23mm Load capacity: 4 Installation: clamp type Output mode: lead output PARAMETERS Electrical parameters Ratio 1000: 1 or 2000:1 (customized) Accuracy class 0.2%, 0.5% Primary current 0 - 10A AC Secondary current 0 - 10mA AC (customized) Max. Cont. Input current 12 A Load capacity 4 Over voltage category CAT III 600V Output signal (AC current) From 0 to 10mA AC at nominal input current Output signal (AC voltage) From 0 to 1V AC at nominal input current Frequency range 40Hz-2000Hz Dielectric strength 3KV 50Hz/60Hz at 1minute Temperature range -20C to +55C Output 2.5 meter cable with D01 connector Max. voltage not insulated conductors 600 V Standard EN 61010-1, EN 61010-2-032, IEC60044-1 Installation Clamp type Output mode Lead output(2.5m) Mechanical parameters Dimensions (L x W x H) (mm) 42.6 122.5 23 Weight (g) 225 Holding wire diameter (mm) 8 Max. jaw opening (mm) 8 Color Gray Material PC+ABS+Polycarbonate, UL94 V0
The FQ-RCTA02 rogowski coil flexible current sensor is designed for easy installed in tight spaces and without the need for dismantling the primary busbar or cables. It includes a flexible Rogowski coil probe and electronic modules. The signal from the coil probe can be amplified by the electronic amplifier modules through the integration processing. The output signal can be directly used in oscilloscope, digital multimeter or data logger recording instrument. good linearity, easy to use, measuring large current, 6000A/3V, 600A/3V, 60A/3V or 3000A/3V, 300A/3V, 30A/3V, lower phase shift. In particular, it can be installed in tight spaces, around cable bundles, around wide or large bus bars, or even wrapped around irregular shapes. Models range from 1 to 100,000Arms with an accuracy of 1% of reading. Rated EN 61010, 600V CAT IV, 1000V CAT III. This feature facilitates positioning the sensor around the conductor, enhances user safety, and alleviates the drooping effect associated with other flexible sensors. FEATURES
Main FeaturesAC/DC Current Sensor Model No.: MEWOI-DRK1D Name: MEWOI-DRK1D-50-500A AC/DC Ï?20mm Open-loop Hall current Sensor Jaw Size21mm Rated input Current IPN50 100 200 300 400 500 A Primary Current Measure range(IP)0~±100 0~±200 0~±400 0~±600 0~±800 0~±800 A Rated output voltage of secondary side2.5±1.25 ±1% V Power Supply Voltage VCCDC +5V ±5% V Current consumptionVCC=+5V 10 mA Galvanic isolation (Vd) 2.5KV /50Hz/1min
SO-E2-960 Limiting Current Type Sensor Oxygen Sensors When voltage is applied to a zirconia electrolyte cell, oxygen is pumped through the zirconia disc from the cathode side to the anode side because the carriers of the current flowing through the zirconia electrolyte are oxygen ions. By attaching a cap with a pinhole on the cathode side of the cell and by increasing the voltage over the cell the current shows saturation due to the rate limiting step in the transfer of oxygen to the cathode. This saturation current is called limiting current and is nearly proportional to the ambient oxygen concentration. Below the advantages of the oxygen sensor: measuring range 1.00 to 96.0 vol.% oxygen High accuracy For many types a more or less linear characteristic Small temperature dependence of the sensor signal Low interference with other gases Long service life In many cases "Single point calibration" necessary only once Applications: Medical Laboratory Food industry Household/Gastronomy Measuring technique Security technology/Monitoring (Electrical-) industry Characteristic Data: Measuring gas: Oxygen concentration Measuring medium: Gaseous atmosphere Measuring principle: Limiting current type sensor Measuring ranges: 1.00 - 96.0 vol.% O2 Response time (t90): 2 to 25 sec. (Depends on: sensor type, gas flow, measuring chamber) Sensor voltage / heating voltage / power consumption / heater cold resistance Sensor voltage: 0.7 to 1.6 Volt Heating voltage: 3.6 - 4.4 Volts Power consumption: 1.3 to 1.8 Watts (depends on application and packaging) Cold resistance: R( 25'C ) = 3.25 ohm ± 0.20 ohm Warm up time: Min. 30 s
BRAND : SCHNEIDER MCB 6A - 32A Single Pole Schneider Miniature Circuit Breaker. Product Specification No.of poles 1-4 Pole Rated current 6 to 63 A Voltage 240-415 V Breaking Capacity 10 kA Frequency 50 Hz Curve Type B and C tripping curves Brand Schneider
We are a company dealing dry fruits, nuts and Kernels etc.. and we currently offer many types of high quality Sunflower seed Kernel, Soybean seeds, Sesame seeds, Pumpkin seeds, Barley seed, Rape seed, Cotton seed, Chia seeds, Wheat and many more. We equally supply nuts like Cashew Nuts, Peanuts, Walnuts, Almonds, Pine Nuts, Macadamia Nuts etc.. in very large quantity and competitive prices. Specification: â??â?? â??â?? â??â??- Type: â??Raw â??Cashew Nut - Packaging: in tin or flexible pack/cartons - Style: Dried - Grade: WW240 and W320 â?¢ Density : â??â?? 240 seeds/kg â?¢ Moisture: 5% max â?¢ Foreign matter: 1%max â?¢ Broken: 5% max â?¢ Live insect and larvas: Negative â?¢ Coliforms, salmâ??â??onella : Negative Nutrition facts: - Calories: 603 kcal/100 - Total Fat: 46.2 % - Saturated Fat: 10.1% - Cholesterol: not detected - Carbohydrate: 25.2% - Saccarose: 9.3% - Protein: 21.6% - Canxi: 46.7 mg/100g - Iron: 5.6 mg/100g â??Packaging: 25kg bags Kraft paper multi-wall with inner polyethylene liner. Steal Drums, or as clients require Minimum Order Quantity: 1X20 FCL Supply Ability: 200MTs/Month
Eddy-current testing (also commonly seen as eddy current testing and ECT) is one of many electromagnetic testing methods used in nondestructive testing (NDT) making use of electromagnetic induction to detect and characterize surface and sub-surface flaws in conductive materials. The two major applications of eddy current testing are surface inspection and tubing inspections. Surface inspection is used extensively in the aerospace industry, but also in the petrochemical industry. The technique is very sensitive and can detect tight cracks. Surface inspection can be performed both on ferromagnetic and non-ferromagnetic materials
current sensor rt63c2 dc0-10v thermal relay CYWP1C3D 220-440V AC used to control the temperature of heating oil in the mud pump BOMCO F-1000 T103-003.19 Membrane keeper 04EA X Nozzle MFG HL-100 Actuator SQX32.00 ZW 10 II600 2.4.20.090 hose assembly Harting shell 09340060301 THROAT BUSHING DY155-67-0017 1.03.16.701 Flat pad Dryer 81099-00-8100 for Air system of Carrier X D-60ZJ-20 AC225002-3200-Break Assembly PIN HINGE 30178847 Sleeve XYQ3C.B-9D Rack pulnger actuator 23042986 24V ENCODER HS35F-100-R2-SS-1024-ABZC-5V/V-SM18-EX 01075-111 57218323 Filter Hydraulic valve MFH-3-1/4 9964 E502 1.5-8bar 21-120 psi Switch Mode Power Supply CP-C 24/10.0 Power supply 1SVR427025R0000 ABB O-ring 140x3.55 BG75B-12 GA105 pressure gauge 5114003 , Ex M T8-14 Explosion-Proof Led Lamp Tube (Led/14w) Series BAY51-Q Led Magnetic contactor HlMC 18 Ith=25A UI=750V.Coil 200V.S0Hz.200-220V.60Hz HRMC20 Central shaft 56.300-08 PIN COTTER 51401-6-S Board driver inventor EI900/MD500 16420 Bladder accumulator NXQ-L80 4807100030 Filtration bar KG80-4 O-ring 568-235 FLO 75DR V14412803 Rear panel universal IC695CHS012 Blind die set F9301.37.00 Sleeve for hydraulic key ZQ 203/100 ZQ203-027 Mesh on vibrating sieve 3 X 1080 X 700 mm to X J-750 mesh 120 flat J234-25 HOSE ASSY,1/4X 25, 5K PSI Pressure transmitter C73451-A407-B7 Bolt 50108-20-C for clamping device TDS-11 for 3-1/2 89 mm DP box 124-127 mm BONNET SEAL J005531439 Roller Z9.HL88R Spring clip 350 E015920 Crosshead AH1001010401 pump BOMCO harting VARIANTEC61835545001 Dynamic Friction Disc WCB224 for drawworks drum JC21D V-belt B54 HI-POWER CATERPILLAR C-15 Jaw 4 45.291E ASSEMBLY,PUMP,WATER,400921-00016C GH3101-06.05.00Shim set Link tilt hydraulic cylinder 30119592 Hacksaw blade for saw blade Oil seal XGGJ-012 TPS63001DRCT PLDP-A Crane engine V-Belt TOYOPOWERRECMF-6570 Valve HH8S366WV Inserts 1.99 65652-1.990 Oil Temperature Sender DC24V 789802-00-0180 for Air system of ZJ-20 Oil seal, 90 for hydraulic wrench ZQ 203/100 ZQ203-091 PH1 Exd, Weatherproof Blade seal 6011815654 Plate for hydraulic key ZQ 203/100 ZQ203-043 5007196 RING,SNAP,WASHPIPE GASKET,DOOSAN,65.05902A0041 Parasitic gear 01.02-02M Pressure valve cover 4M50104.13JT25-02-47C DYMANIC BRAKING RESISTOR YTDZ 43A 20070106 Tooth plate L137 4.10.01.030 hexagon socket head screw Check valve S6A1/2 HARTING 9990000319 YELLOW PLASTIC DUST CAP 1-1/4 WF28 MD TOTCO EDMS BOARD 219770-001 Weighing display instrument PLAC-5105L-R-P O-ring bushing AN33001-05.04 O RING: 175 X 3. 55GGB/T3452.1-1992 Screw M8x15 with hex head and full thread GB/T5783-2000 ZQ203-160 Break strap ENG.6.40.066-10.01 ZQ203 01.06.00m
ABB 64750097 IP54 RH35M-4EK Oiler 45 M10x1 KG80-20 MCS7 Ex d fixed camera station MD TOTCO INTRINCALLY SAFE MODEM 219916 https://www.amlppmfg.com/circlip-for-shaft-70-w05293070-sand-pump-sb6x8fj.html PLDP-A DEG engine model NTA-855-G4 ESN 25325738 GH3101-27.03.00Air bag 4801010140 Chain 24SAX122 122section Sealing ring for hydraulic wrench TQ340/35YA TQ340-165 Solenoid valve DSG-0-3C4-A200-70 YUKEN Screw M12x25 KG80-19 Guide ring KG80-15 Bearing NB800G.04.17 Guide LGF3101-05.12G Loadmaster Spring 7'' 9360007 Voltage sensor NPGL-CX5D 275-2604 Engine oil filter XB8 0.5 Joule Xenon - Exia (Intrinsically Safe), Weatherproof ZPEC ZM107.03.62.00 LINER 6-1/2" WITH LINER SEAL POLYPAK S03-1019-010 Packing 60BG26 GH3161-05.27 G on ZJ-50/315 DB19 valve guide GUIDE 125128 Block booster station QWS-2500 pump standard : according to technical task harting connector 9330102616 LEVER FOR VALVE 10" 24230001 Crown block roller P1000529AA for XJ-450S THE FLOW TIME DELAY RELAY FPTB180 Transfer cylinder 02-00M Adjusting nut BG75B-16 SEAT 1786031 Current sensor JA866-3I XP40-Ti Explosion Protected Thermal Imaging PTZ Camera Stations Intermediate relay DRM570730LT 51403014007 Control valve for gear shiftHNR-R431003806 Valve four X X single hydraulic Z07060400005AA Cover 1468.032.000-07 Oil scraper ring for reciprocating engine QB7400.9.00-2005 Central gear 56.321.02/56.321.00 STUDNUT, PN.H13-1035-01A Clamp RS11309.05.04.00 SPTA pump F1300 Piston Application: safety valve SIN25.100 according to tech task Material: rubber Rubber ram core 5" DFZ1310-01A-01-00 GH3101-05.03Stick, liner cover Weatherproof Signalling Hooter HPW12 Draw-work control handle BVV81B3KM-03ZP-X O-ring kit 143 03734279 harting HAN15D09200100321 Lock spring washer 29540988 Valve spring RGF1000-05.16 3906 BLOCK,TERMINAL,WK 4/U,600V,40A 77992-1080 Potting Compound Metal Seal 6-5/8". THERMOMETER, PN.N14-1000-020 Sealing ring AN33001-04.06A M/D TOTCO connector J10900A-20\308240 GFD(S)D760/90-1000 Top Blowing Fan RGS4/100A FUSE FSYT-2 fully sealed integrated camera Gear small 21 teeth ZP275-20.01 Cotter pin 2x14 for hydraulic key ZQ 203/100 ZQ203-105 Support bearing pad 533X9TC33B BZ000005-V-belt 4ZV25J-7620 CHECK VALVE 90251000 08MK650 346-8340 Hydraulic tank breather Seal 0766945 Weatherfor MOTOT YS-550W-4P Fan YDK600-8AA 600W 380V 2.1A Fuel water separator Filter 20998367 Cooling Fan X45.25 No for Kiln Shell LOWER RING ASSY 350 E028650 "Panel View Plus Logic Module 24VDC, CAT:2711P-RP9DK, Make: Allen Bradley, USA" Weatherproof Signalling Bell UWE 321-4686 breather
The HQ15 100a current probe sensor is designed for easy installed in tight spaces and without the need for dismantling the primary busbar or cables. The sensing head uses sliding push-fit clamp structure, safety isolation to avoid the user to contact with charged objects directly. It complies with CE standards and meets 300V CAT III safety class. This model HQ15 current sensor is a high accuracy mini current probe for measurements up to 130A AC. This current probe uses a special magnetic core to provide higher accuracy and lower phase shift. The HQ15 Series is an excellent probe sensor to be used in power and low level current measurement applications. FEATURES UL, CE CNAS mark Excellent linearity High content permalloy core Holding wire diameter: 15mm Frequency 10Hz-5kHz Bandwidth High time harmonics measurement Easy &quick installation in tight spaces; Measurement range of 1mA to 130A AC; Low phase shift for power measurement; Â EN 61010-2-032 , 300V CAT III Standard Improved ergonomic design & easy operation; High precision 0.1% for current measurement Flexible and light weights, exquisite appearance;
Three phase current transformer Model: SCT2851A, SCT2851B, SCT2851C Input current: 60-630A Output current: 5A/ 1A Accuracy: 1.0/0.5
So-e2-960 Limiting current type sensor oxygen sensors When voltage is applied to a zirconia electrolyte cell, oxygen is pumped through the zirconia disc from the cathode side to the anode side because the carriers of the current flowing through the zirconia electrolyte are oxygen ions. By attaching a cap with a pinhole on the cathode side of the cell and by increasing the voltage over the cell the current shows saturation due to the rate limiting step in the transfer of oxygen to the cathode. This saturation current is called limiting current and is nearly proportional to the ambient oxygen concentration. Below the advantages of the oxygen sensor: Measuring range 1.00 to 96.0 vol.% oxygen High accuracy For many types a more or less linear characteristic Small temperature dependence of the sensor signal Low interference with other gases Long service life In many cases â??single point calibrationâ?? necessary only once Applications: Medical Laboratory Food industry Household/gastronomy Measuring technique Security technology/monitoring (electrical-) industry Characteristic data: Measuring gas: oxygen concentration Measuring medium: gaseous atmosphere Measuring principle: limiting current type sensor Measuring ranges: 1.00 - 96.0 vol.% o2 Response time (t90): 2 to 25 sec. (depends on: sensor type, gas flow, measuring chamber) Sensor voltage / heating voltage / power consumption / heater cold resistance Sensor voltage: 0, 7 to 1, 6 volt Heating voltage: 3.6 â?? 4.4 volts Power consumption: 1.3 to 1.8 watts (depends on application and packaging) Cold resistance: r( 25'c ) = 3.25 ohm â± 0.20 ohm Warm up time: min. 30 s -
Feature designed with metal platform suitable for fastener size between M3~M20 and auto parts inspection spec: auto parts, larger screw and ODM special customize size Inspection criteria Our AOI machines are different from old style index plate, continues rotating platform operating smoothly, avoid the problems of bumping and slow inspecting speed occurred on go-and-stop index style machine. Inspection criteria Our AOI machines are different from old style index plate, continues rotating platform operating smoothly, avoid the problems of bumping and slow inspecting speed occurred on go-and-stop index style machine.