The svc is made up of controllable reactance, passive filters (fc), and control and protection unit. At present, terms of the principle on which the reactance is adjusted, static var compensators are classified into three types: thyristor-controlled transformer (tcr), thyristor-controlled reactor (tcr), magnetic-controlled reactor (mcr). For their working principle and difference, see í¦svc operating principle Senbao has developed all the three types of static var compensator and launched them on the market successfully. As the only manufacturer in china possessing proprietary intellectual property right of the three types of svc, senbao offers the best performance-to-cost svc solutions and complete set of equipment to fulfill user requirements. Technical specifictations: 1.Rated voltageú¦6íó10íó35kv 2.Rated capacityú¦6~100mvarú¿tcrú¬ú¼ín30 mvarú¿tctú¬ú¼ín30 mvarú¿mcrú¬ 3.Response timeú¦10msú¿tcrú¬ú¼10msú¿tctú¬ú¼300msú¿mcrú¬ 4.Thyristor coolingú¦heat pipe self-cooling plus fans (tcr), heat pipe self-cooling plus fans (tct), self-cooling (mcr) 5. Thyristor triggering: optical fiber plus electro-magnetic (tcr), electro-magnetic (tct), optical fiber (mcr) 6. Controller: all-digital 7. Control modes: voltage, reactive power, power factor, or combination 8. Dynamic regulation: combination of open loop and closed loop control 9. Regulation mode: phase splitting control, compensatiing for unbalanced load 10.Useful life: 10 years 11.Environment: the svc can be made to work normally under user-specific environmental conditions.
Frequency range 1.000mhz 40.000mhz Frequency accuracy 1.0ppm/max Smd type. Size 50*32
Self compensating drippers Specifications: Self-compensating drippers (drain) Available flow rates:2lph,3lph,4lph,8lph, and 24lph Features: - uniform flow rate regardless of inlet water pressure and field slope - wide compensating range:0,5 - 4,0bar - self-flushing mechanism that ensures resistance to clogging - resistant to commonly used fertilizers, chemicals, and acids - nipple outlet ensures no run off along the lateral when hanging especially on grapes - ideal for trees as it can be added to serve the plant maturity - multi purpose use, ranging from orchards and grapes, to greenhouses, nurseries and landscaping - can be applied on various pipe sizes - adaptable to 4outlet manifold and spike drippers for better water distribution - micro tube connection to facilitate micro tube extension or dripper cap - special 'no water spring cap' available for 8 and 24 lph drippers - color-coding for different flow rates Self-compensating drippers (no drain) Available flow rates:2lph,3lph,4lph,8lph 0,2bar closing pressure 0,4bar opening pressure Features: - no water drainage when irrigation cycle stops; no need to refill the system - immediate pressure compensating flow after system start up; no need to wait for pressure built up - accurate irrigation for frequent cycles and hydroponics crops Accessories - spike 6x4mm - spike 4lph - 70o 5mm - dripper spike 5mm - hydroponics distribution manifold 5mm x 2outlets - hydroponics distribution manifold 5mmx4outlets crops type - hydroponics distribution manifold 5mmx4outlets - spaghetti hose - PE pipes
Bobby veal Veal leg Veal tenderloin
High Voltage Dynamic Reactive Power Compensation Device SVG reactive compensation device SVG also known as high voltage dynamic reactive power compensation generating device or static synchronous compensator, which is an equipment providing dynamic reactive power compensation through the self-commutated of the power semiconductor bridge converter. High Voltage Automatic Compensator is widely used in petroleum chemical industry, metallurgy, electric power, coal, electric railway, wind power station, as well as some other industrial fields with or near the impact load and large capacity motor. And plays an important role in saving energy and reducing consumption, improving power grid security and stability, increasing power grid power factor, improving power quality, etc. Providing concentrated compensation to improve the power factor for 3~10KV power supply network Based on DSP full digital control system, fast dynamic response time and high control precision Adopt photo electric trigger mode, high potential plate and high voltage-energy, thyristor switched capacitor protection, and strong anti-interference ability
Quick Details Place of Origin: Zhejiang, China (Mainland) Brand Name: Ehase-Flex Model Number: EH-TPC Material: Stainless Steel Technics: Non-Weld ,Intergral Flange Connection: Flange Shape: Equal Head Code: Round Product Name: Flange connection bellows compensator Application: Absorb the vibration and reduce the noise NominalBore: DN50-DN800 Working Pressure: 10Bar, 16Bar,25Bar Rating Temperature: Max 1000 â?? Flange Standard: JIS,ANSI,DIN,B.S.JB,ETC Test: 100% Tested with 1.5 Times Road OEM/ODM: Allowed Standard: EJMA Certificate: ISO Supply Ability Supply Ability: 80000 Piece/Pieces per Year HS Codet: 7307 99 Packaging & Delivery Packaging Details Carton Box, Pallet or Plywood Case; As Customer's Requirement No Unacceptable Packaging Material or Bamboo Products Been Used as Packing Port Shanghai or Ningbo or Any Port in China Lead Time : Quantity(Pieces) 1 - 50 >50 Est. Time(day) 10 To be negotiated Product Description Flange Connection Bellows Compensator Application  Used for pump to link with tube, absorbing vibration and reducing the noise. Integral flange makes strong and durable Construction Item Parts Material Remark 1 Bellows SUS304 SUS316/321 2 Flanges Q235B SS400/SUS304/316/321 3 Tie Rods S25C  4 Gaskets EPDM Natural Rubber Specification Nominal Bore Total Length Bellows O.D. Max Offset Working  Pressure mm ins mm ins mm mm bar 50 2 150 6 70 15 10 16 65 2 1/2 150 6 86.5 14 10 16 80 3 150 6 101.5 12 10 16 100 4 150 6 128 10 10 16 125 5 150 6 156.5 8 10 16 150 6 150 6 183.5 8 10 16 200 8 200 8 234 8 10 16 250 10 200 8 289 6 10 16 300 12 200 8 341 5 10 16 350 14 200 8 402 5 10 16 400 16 200 8 452 5 10 16 450 18 200 8 507 5 10 16 500 20 250 10 563 5 10 16 600 24 300 12 673 5 10 16 700 28 300 12 773 5 10 16 800 32 300 12 875 5 10 16 *Specification stated above are standard. We can design and manufacture according to customer's requirement. *Flange standard: JIS, ANSI, DIN, B.S., JB, etc Features 1. Excellent Welding Technology, like a fish swimming in water. 2. Omega Bellows, More flexible and longer service life. 3. All-in-one part construction, which can withstand greater pressure. Production Process Production Capacity Flexible Sprinkler Hoses: 350,000pcs per Month Flexible Joints/ Expansion Joints: 80,000pcs Annual Gas Connector: 300,000pcs Per Month Water Connectors: 5,000,000m Annual Testing 100% Before Delivery Packaging & Shipping Carton Box, Pallet, or Plywood Case NO Unacceptable Packaging Material or Bamboo Products been Used as Packing
SSQ-6C/10C Compensator Main parts and materials:  Parts name material Bodyã??Bonnet Ductile iron ;Cast  iron Disc Brass Stem Stainless steel Ball float NBR/ABS/EPDM  Test  Nominal pressure Shell test Seal test 1.00 1.50 1.10 1.60 2.40 1.76
The Dispersion Compensation Modules are building blocks of the HT6000 Optical Transport System and serve at optical communication nodes to correct the pulse spread phenomenon known as Chromatic Dispersion that reduces the maximal transmission distance of data in optical fibers. Dispersion compensation in long haul WDM networks DWDM system dispersion compensation and broadband low residual dispersion G.652 fiber C-band 100% slope compensation (standard value) Low insertion loss Low polarization mode dispersion Hot swappable Low power consumption Support for 10/40/100/200/400Gbps C-Band Range HTF optical compensation function with slope dispersion compensation for standard single-mode fiber can DCM (G.652) were dispersion and dispersion slope compensation broad band in the C-band, allowing the system to optimize residual dispersion. In the dispersion compensation value of 1545nm wavelength dispersion can reach -2070ps /nm. The DCMs offer a high dispersion compensation level and a very low insertion loss penalty. They provide negative dispersion compensation over the full C-Band with possible distance extensions of up to 80 kilometers.
The pressure compensating dripper has a labyrinth runner, a scientific structure, stable quality of the silicone sheet, and good pressure compensating effect; The pressure compensating dripper comes with an extra-long filtered water inlet, which has good anti-clogging performance and long service life; Anti-siphon mechanism prevents sediment and other debris from being sucked back into the dripper when the system is shut down, and can be used for underground irrigation; The pressure compensating dripper has small manufacturing deviation, uniform water output, and long laying length.
Model: WBB Automatic high voltage reactive power compensation device 1) Range of application: industry with high-voltage motor or 3-10KV power supply system 2) Main function: 1: Circuit factor power compensation , improve power factor over 0.95 2: Regulating power network voltage quality, 3: Reducing cable power consumption , reduce line loss 4: Improving the quality of power supply , stabilize power quality 5: Increase load ability 3)Characteristic: 1: Equipped with good discharge measures , residual voltage decrease to less than 50V in 1 miniute when the devices cut off from network. 2: High pressure ejecting fuse are adopted as short circuit protection for single capacitor to ensure the safe operation of the devices. The main protections include neutral unbalanced current protection, split triangular voltage protection and voltage differential protection. 3: Series reactors with impedance ratio of 1%-13% is adopted to limit the switching-on current and the 3rd harmonic and above 4: Perfect protective measures including, over-current, transient break, over-voltage, low voltage and so on, with a separate protective screen to ensure safe running. Standard working condition: Ambient temperature-40C ~ +45C air relative humidity
As a upgrade var compensator for substations, the svqr has remarkable advanteges in many aspects such as var compensation precision, , response speed, stabilization of system voltage, reduction of line losses, and enhancement of transmission capacity. Senbao developed, for the first time in china, the substation var compensator, svqr, whose output is changed by regulating voltage across the capacitor. The svqr has found wide applications in substations. With complete hv and lv testing beds and the-state-of-the-art dsp-based control system development system, senbao has gathered a large army of excellent professionls and has passed the national iso 9001 quality system certification. The svqr is widely applied not only for new substations, but also for upgrading of existing substations, transforming the existing manual 1-step tbb into an automatic 9-step voltage-regulating-type var compensator. Senbao svqr has been operating successfully at an altude of 4, 000 meters in the cold area of shangri-la, yunnan, way ahead of the domestic manufacturers of the like products.
Top side Silver side Thick flank Rump steak Tenderloin Strip lion Beef slice
Advantages: good flexibility, good sealing, easy installation Because of its light weight, small size, corrosion resistance, high pressure and other characteristics are widely used in aerospace, petrochemical, metallurgy, paper, food transportation and other industries.
Capacitance: 0.1-100uF Kvar range:250-3000kvar Rated Voltage: 375-3000V. AC Lifetime Expectancy: 50,000 Hours Application: Induction heating system, dissolve, mixing, casting machine.
Smart Filtering Reactive Compensation Capacitors Details Our company specializes in export Smart Filtering Reactive Compensation Capacitors Basic Information: product: Smart Filtering Reactive Compensation Capacitors Design Style: High Cylindrical Inner Core: one core Core material:Aluminum foil...
100% Halal Meat according to Islamic rites and hygienic conditions.Our product do not contains fat.
The built-in flat dripper pressure compensation drip irrigation belt uses a small dripper with a compensation structure to replace the original ordinary dripper, so that the drip irrigation pipe can ensure a uniform flow within a certain pressure range, and effectively solve the problems caused by terrain or terrain. problems of uneven water supply and differences in crop growth.
GGJ capacitor cabinet adopts computer-aided design (CAD), the introduction of microcomputer control, the implementation of intelligent tracking compensation of reactive power, its reasonable structure, advanced technology, widely used in low-voltage power grid, improve the power factor, reduce reactive power loss, improve the quality of power supply, is a new generation of energy-saving products. It is specially used for reactive power compensation of capacitor 130-600KVA three-phase change voltage.
TBBX high voltage re active power local compensation device is suitable for small load change, need to compensate a single motor and other equipment that needs compensation, has been widely used in metallurgy, mining, building materials, petrochemical and water supply and drainage industries, can effectively improve the power factor of the power system, reduce the re active power loss of lines and equipment, improve the output of equipment, thereby saving electricity energy. Improve power supply quality. The ZRTBBX series reactive power local compensation device developed and produced by the division adopts advanced design concept and advanced production technology as well as sound quality assurance system and after-sales service system, so that the product has been continuously improved in technical content and quality.
TBBZ High voltage reactive power automatic compensation device: Applicable to 220KV, 110KV, 35KV substation 35KV, 10KV(6KV) bus automatic reactive power tracking compensation, mainly for 3~35KV three-phase power frequency AC power system load fluctuations, the use of centralized compensation still can not meet the system requirements, often cause overcompensate or undercompensate situation. The installed device can detect the reactive power required by the system in real time, and then compare with the set value, and carry out automatic intelligent switching operation, so that the reactive power of the system reaches dynamic balance, in order to improve the power factor of the system, stabilize the system voltage, reduce the loss, and save the cost of electricity.