The Dispersion Compensation Modules are building blocks of the HT6000 Optical Transport System and serve at optical communication nodes to correct the pulse spread phenomenon known as Chromatic Dispersion that reduces the maximal transmission distance of data in optical fibers.
Dispersion compensation in long haul WDM networks
DWDM system dispersion compensation and broadband low residual dispersion
G.652 fiber C-band 100% slope compensation (standard value)
Low insertion loss
Low polarization mode dispersion
Hot swappable
Low power consumption
Support for 10/40/100/200/400Gbps
C-Band Range
HTF optical compensation function with slope dispersion compensation for standard single-mode fiber can DCM (G.652) were dispersion and dispersion slope compensation broad band in the C-band, allowing the system to optimize residual dispersion.
In the dispersion compensation value of 1545nm wavelength dispersion can reach -2070ps /nm.
The DCMs offer a high dispersion compensation level and a very low insertion loss penalty. They provide negative dispersion compensation over the full C-Band with possible distance extensions of up to 80 kilometers.
Supplier: Transmission equipment, optic transceiver, optical module, amplifier, olp, obp, dispersion compensator , plc splitter, optic coupler, optic circulator, optical switch
Supplier: Pressure sensor, CO2 sensor, silicon pressure sensor die, uncompensated pressure sensor, guage pressure sensor, absolute pressure sensor, compensated pressure sensor, manifold absolute pressure sensor, NDIR CO2 module, silicon pressure sensor wafe
Introduction Irm300 is one of the general ndir co2 gas modules, which adopting ndir principle, consists of carefully designed light chamber, precise electric circuit and intelligent software. With the help of single light source, dual channel detector, and Unit Storage temperature Tstg -20 to 80 ¡ãc Working temperature Ta 0 to +50 ¡ãc Working humidity Ha 0 to 90 % rh Working pressure Pa 0.8 to 1.2 Atm Electric characteristics Description Symbol Min. Typical Max. Unit Supply power Vs 4.6 5 5.4 V Maximum current Imax 130 160- Ma Light current Iavg 60 70 Ma Frequency F 0.2 1 2 Hz Preheat time Twarm 90 120 180 Sec Performance characteristics Description Min Typical Max Unit Detection range 0 2000 50000 Ppm Detection accuracy - ¡¨¤60ppm¡¨¤5% fs - Ppm T90 Diffusing - 60 90 Sec Pumping - 10 20 Sec Repeatability Zero
L high reliability, low drift Applications L automotive pressure monitoring L pneumatic gages L hand-held meters
Supplier: Wati-hour meter, capacitor series, reactive field compenstor, reactive power auto compensation controller, leakage circuit protectment series, cj19 switch-over capacitor contactor, dz47 miniacture circuit breaker with hign breaking capacity plastic moulded cased circuit breaker, dz series leakage circuit breaker, cj series ac contactor, knife switch series, module sockets
4-20mA analog output for direct communication to DCS system or RS485 ModBus RTU output optiona. Relay output for connecting external device LCD display screen(LED display screen optional) Advantage: Sensor module(block) design on -spot replacement s and automatically distinguish sensor fault and current display fault simultaneously. When the sensor out of service or the sensor fails, the user can check and solve the problem by replacing spare modules,saving the time and cost. The LCD display and LED display module can be interchanged, supporting swift hot swap,support plug and play functionality. The sensor module and the connection interface in the detector have jack and plug prevent improper insertion.Just spin and press the plug gently,the plug can be inserted the jack. The sensor module of the detector can be replaced by the same type module and the different gas sensor module,and different range sensor module. The detector can distinguish and operation itself. Whatever the sensor module is chosen to replace the original one, there is no need to re-calibrate it. The detector automatically distinguishes the sensor module, reads the ex-factory calibration value and the related setting value and operates detecting when the self-inspection is done. Password verification for repeat operation, avoid fault operations. -40~+70 following compensation for accurate detecting. Twp grade visual alarms on-site and Relay (connected with audible/visual alarms or drive exhaust device). User-selectable alarm setpoint(s).
Specially design for solar-public electricity system, which is in exchange of the solar system, it has power switch where there is a shock by the battery or utility grid, and also the utility grid supply charging module. Its energy saving, and also ensures the power supply. It also has the same function of eprc. Specifications: 12v, 12/24v, 5a, 10a, 15a Use mcu and professional software as the control center to fulfill intelligent soc control, protection to overload, outside and insdie short circuit, reverse connection, thunder and lightining, pv panel reverse current, over charge and discharing etc, usd pwm high efficiency charging way and temperature compensation. Industry level production standard, led indication on system condition. The controller pcb is pained with england apl lacquer, its highly moisture-proof Packing:1pc/color box, 50pcs/carton, carton size:51&31&21cm.Gw:13.5kgs, nw:12.5kgs
NCS Series of Intelligent Transmitters are digital, intelligent, network-based, merged with advanced, reliable and stable sensor technology, to be designed as a new generation of Fieldbus Intelligent Transmitter. NCS Series of Intelligent Transmitter have been designed with high precision and high reliability, high stability. The pressure, temperature, currents and other physical quantities are displayed on LCD module. Zero drift, range settings and many other functions, are realized by the magnetism bar operation. The interoperability between different systems and equipments are realized by the Equipment Description Document, which is compatible to a variety of device management software, and adapting to harsh electromagnetic environment. NCS Series of Intelligent Transmitter have been used in inflammable and explosive places according to Intrinsically Safety Design. The Fieldbus Technology is used in NCS-TT105 Intelligent Temperature Transmitter, which is a new generation of Fieldbus Intelligent Temperature Transmitter, also an indispensable field device in control processing. It is integrated with a variety of functional modules, to realize not only the general testing functions, also the complicated control strategy. Digital technology is applied in NCS-TT105, which has been used in a wide range of thermal resistance and thermocouple sensors. It has a wide measuring range. Because of the simple interface between the field and control room, the costs of installation, operation and maintenance are reduced a lot. NCS-TT105 Series of Intelligent Temperature Transmitters, complied with FF Protocol, have been widely used in petroleum, chemical, metallurgy, electricity, cement,etc. Thermo resistance additional parameters as follows: Parameter Function Description COMP_WIRE1 Linearization compensation for thermo resistance 1 selecting 2-wire or 3-wire. Unit is fixed as Ω. COMP_WIRE2 Linearization compensation for thermo resistance 2 selecting 2-wire or 3-wire. Unit is fixed as Ω. SENSOR_CONNECTION It can be used to connect sensor with 2-wire or 3-wire. 0: 2-wire 1: 3-wire
Basic Parameters a) Rated voltage (Un) 230v~, 120v~ b) Rated current (In) 10A, 13A, 15A, 16A, 20A. c) Rated frequency (FN) 50Hz/60Hz d) Life: circuit protection device: 10,000 times; normal operation: 8000 times. Protection Functions: 1, Leakage protection(GFCI function): When body touchs electricity, earthing is unusual, power will be cut soon within 25ms. There will never be danger of electric shock. 2, Surge protection: Power will be cut at once when surge or thunderstroke, in order to protect all working electric equipments. 3, Overcurrent protection: Protect all working electric equipments from surge and heavy current in circuit. 4, Short circuit protection: Power will be cut within 25ms when short circuit happens. 5, Overvoltage protection: Protect electric equipments when external voltage exceeds standard. 6, Undervoltage protection: Protect electric equipments when external voltage is under standard. Energy-Saving: 1, Alternation current reactive power compensation energy saving: Reactive power compensation built inside, in order to improve electro-power factor, adjust network voltage, reduce circuitry waste, improve quality of power supply. This can save 10%-30% electricity. It specially works well for electric machines such as fridge and washer. 2, Time-delay standby / Timing energy saving: This product includes time-delay energy saving component and timing energy saving component (optional). Time-delay component can stop power supply automatically to avoid electricity waste, while electric equipments are standby. Timing component can define any power off time within 24 hours, with easy operation. Product characteristic: A, Zero power dissipation permanent magnetism breaker module built-in, safe without delay. B, Produced with silver alloy contacts, safe and reliable with excellent electronic conductivity. C, Case is produced with PC fire-retardant material (94UL-V0). Inside material produced with heat resisting nylon. D, Copper components produced with extra heavy phosphor bronze, with high metal memory, can be pluged 8000 times. E, One-button smart test function, can test protection function of product to avoid malfunction. F, USB charger component (optional), supplies DC 5V power for all kinds of usb products. G, Neoteric cable fixture on side of socket, can fix cables of electric equipments and makes them orderly. blister packing, ctn size:45*45*40 cm ,25 pcs.