We can supply - hydroperoxides, peresters, peroxycarbonates, diacyl peroxides, ketone peroxides, dialkyl peroxides and perketals as Trigonox, Butanox, Laurox and Perkadox. Major applications are: Initiator for the production of thermoplastics such as PE, PVC and EPS. Curing agent for thermoset resins Crosslinking agent for elastomers and thermoplastics. Modifying agent for polymers such as polypropylene Reagent in pharmaceutical synthesis For price, specifications and other details please contact us.
Transmission lines are the connectors running between generating stations and distribution stations. Transmission lines carry high voltages from the generating stations to primary transmission stations, secondary transmission stations, primary distribution stations, and secondary distribution stations
PTFE is also used to make gaskets because of its strength and heat resistance. It is also used as a thread seal tape for plumbing. PTFE also has good electric insulation properties and thus it is used to insulate cables and connector assemblies For price , specification and other details please approach us with end Buyers LOI and company profile
2 Volt LMLA Battery Cell Features Positive Plate-Tubular low corrosion grid & Low self-discharge rates. Negative Plate- lead grid providing low corrosion & low enhanced force life because of very less discharge Terminals �¯�¿�½?�?�¯�¯�¿�½?�?�¿�¯�¿�½?�?�½?�?�¯ï¿½?�¿ï¿½?�½?�¯�¿�½?�?�¢?? Antimonial lead, specially designed for sustained high current Container & lid-high grid polymer Separator-Envelope type high density and porosit Connectors-lead plated copper connectors. Advantage Easier to Install Low water top-up during service life. Long life because of very low corrosion & enhance free self discharge rate. Proven cycling & deep cycling capability Enhancement in life High buy back value after the end of the life. Eco Friendly Low emission of corrosive fumes or gases under normal operating conditions.
Parts material hole siz Shell Zinc alloy Finish Nickel plating
Pitch: 1.27mm/2.0mm/2.54mm Sleeve: Brass CuZn36Pb3(C36000) Contact Clip: Beryllium Copper(C17200) Insulator: black glass filled polyester PPS + 30%G.F Row: sinngle row / dual row socket connector strips
- Bar Connector - Terminals - Auto Connector - EV Charging Connector - Mobile Connector
Silver Plated Braided Copper Flexible Connectors Copper ferrule conforming to BS:2871 (C101) Highly flexible dimension of 0.051mm (47 SWG) to 0.61mm (23 SWG) Retains good flexibility. Confirming to BS:4109-1970 (C101) Available in the finish of tinned, un-tinned or silvered.
VIBRATION CONNECTORS MANUFACTURERS & SUPPLIERS Stainless steel vibration eliminator: Aeroflex Vibration eliminators are specially designed to absorb mechanical vibration and destructive force of noise which is transmitted by the compressor, and also eliminate the stresses linked with piping thermal expansion in refrigeration and air condition installation. These connectors are TIG welded stainless steel hose with copper pipe, due to there is not any brazing so these connector bear more temperature as compared to brazed fitting The main function of vibration eliminator is to absorb compressor vibration and stop its transition into pipe network, by isolating the vibration the risk of damage to pipe work and related component reduce, 1.1 Size range of vibration eliminator: The comprehensive range of vibration eliminator are available from to 3 1/8 Outer diameter of copper tube, copper tube are comply a per ASTM B88 & ASTM B88M (water & general plumbing system) & ASTM B280 (air conditioners & refrigeration system) 1.2 Material specification: Aeroflex Vibration eliminators are manufacture from EN 10028-7, Stainless steel SS 321 & SS 316L annular corrugated hose with SS 304 stainless steel braid. All unit are brazed with copper tube, detail dimension of pipe and vibration connector are in the table. All the units are ultrasonically cleaned and completely dried made suitable to refrigeration system Individual package of connector are remain under sealed plastic tubing. The maximum test pressure is 1.5 time of maximum operating pressure and minimum burst pressure is 5 time of maximum operating pressure. Copper tube end are designed as sweat connection for refrigeration tubing which have inner surface as per ASME B16.18 1.3 Installation conditions: Aeroflex vibration eliminator should be installed as close as possible to the compressor and end away from the source of vibration. Vibration eliminator should be installed perpendicular to the direction of vibration (in-line with the compressor crank shaft) Horizontal Vibration: Where source of vibration is only in the horizontal plane, a single vibration and noise eliminator may be installed. Best results will be achieved by installation at 90�° to the source which is normally the crank of the compressor in a horizontal plane. See fig. 1 Vertical / horizontal vibration: Where the source of vibration and noise is in both horizontal are in vertical planes. Best result will be achieved by installing two vibration eliminators at right angle to each other see fig. 2 Although the copper tube end of vibration absorber are attached by TIG welding (special alloy filler) during installing if unit is over heated there is not effect on the connector
Our separable connectors for IEC markets are compliant with the equipment bushing standards EN 50180 and EN 50181. Our separable connectors for IEEE standardized markets are made of EPDM rubber for low tension set and high dielectric strength. Both product lines are IEEE 386 compliant and available with accessories such as test points, cable sealing, grounding kits. IF you are interested in the spare parts of separable connectors to to connect cables to transformers, switchgear units and motors, please feel free to contact me
EVT EMT connector set screw type is UL listed with UL file number E343475 that is for the EMT fittings manufactured according to UL 514B and C22.2 No. 18.3-12 Conduit, Tubing, and Cable Fittings EMT straight connector is used in dry locations to bond EMT electrical conduit to an electrical junction box or enclosure. EVT can provide set screw type EMT connectors in zinc, steel and aluminum that can meet all your requirements in different markets. The EMT set screw connector provides concrete tight protection when taped and is available in trade sizes 1/2" through 4". EMT connector set screw type sizes 2-1/2" to 4" is also suitable for RMC and IMC Conduits