Cable Standard Generally conforms to IS 694:2010, IEC60228, BS 6004 Silent Features - Special heat resistant insulation - Higher current carrying capacity - Fine copper wires - Highly thermal stable insulation - High electrical conductivity - Long Life - Excellent mechanical & electrical properties Technical Data Operating Temp : -10�?�°C to max.+90�?�°C Nominal voltage : 1.1 KV Test voltage : 3.0 KV Standard Packing Coils 100, 200, 500 and 1000m. Conductor Bare Copper class1 or class-2 as per IS:8130, IEC 60228 Insulation PVC FR, FRLS,HRFR,ZHFR as per IS:5831-1984 Color Black, Green, Yellow/green or as per customer requirement Application Neskeb - Earth : Installation in surface mounted or embedded conduits, or similar closed systems
Cable Standard Generally conforms to DIN VDE 0281-5&2, BS:6500, EN-50525-2-11, IEC 60227-5 Cable Features - Special heat resistant insulation - High current carrying capacity - Less heat energy radiation - Longer life - High compatibility of cores - Excellent resistance to moisture, abrasion, grace, oil - Excellent mechanical & electrical properties - Insulation is highly thermal stable - Harmonized acc. to European standards Technical Data Working Temp : -5C to 70C Operating Temp : 20c to +80C Nominal Voltage : 300/500 V Test Voltage : 2000V Min. Bending Radius : 6x Cable Diameter Standard Packing Coils 100, 200, 500 and 1000m Conductor Annealed flexible bare Copper (Class 5 - Flexible Plain Copper) according to VDE 0295 IEC 60228. Insulation PVC T12 to according to EN 50363-3, BS 7655 Sheath PVC TM2.to according to EN 50363-3, BS 7655 Color White, Black, Blue or as per customer order Core Identification 2 Core - Blue & Brown 3 Core - Yellow/green, Blue, Brown 4 Core - Yellow/green, Blue, Brown, Black or Yellow/green, Brown, Black, Grey 5 Core - Yellow/green, Blue, Brown, Black and Grey Application H05VV-F cordage is a flexible PVC insulated, PVC jacketed harmonized cord recommended for use in electronic and electrical equipment such as office.
Silent Features (FR and FRLS) - Good Flame Retardant Properties - Excellent resistant to moisture, abrasion, grace, oil - Long Life - Excellent mechanical & electrical properties - Steam and boiling water resistant Silent Features (ZHFR) - Zero Halogen acid gas Evolution - Non-corrosive and non-toxic insulation - High-temperature resistant insulation - Better Flame retardant property - Excellent resistance to moisture, abrasion, grace, oil - Long Life Technical Data Operating Temp : -10Cto max.+90C Nominal voltage : 1.1 KV Test voltage : 3.0 KV Flame propagation : Flame retardant test as per IS 10810-58,64, IEC 60332-1 Standard Packing Coils 90m, 180m and 360m Conductor Annealed flexible bare Copper class-2 and class-5 Conductor as per IS:8130-1984 Insulation PVC FR, FRLS,HRFR,ZHFR as per IS:5831-1984 Color Red, yellow, Blue, Black, Brown, Grey, Orange, White, Green, Yellow/green or as per customer requirement Application Fixed installation in conduits and under plaster, for appliance wiring & distribution stations. Fixed Wiring in Conduits & Building wire Application
Cable Standard IS 694:2010, BS 6500 Silent Features - High Flexibility - Excellent resistant to moisture, abrasion, grace, oil - Long Life - Excellent mechanical & electrical properties Technical Data Working Temp : Max.+70�°C Nominal Voltage : 1.1 KV Test Voltage : 3.0 KV Min. Bending Radius : 6 x Cable Diameter Standard Packing Coils 100, 200, 300 , 500, 1000m. Conductor Flexible Bare or Tinned Bunch Copper as per IS:8130-1984 Insulation PVC as per IS:5831-1984 Sheath PVC as per IS:5831-1984 Core Color As per IS 694 : 2010 2 Core â?? Red & Black 3 Core â?? Red, Black, Green or Red, Yellow and Blue 4 Core - Red, Yellow, Blue and Green or Black Application Ideal For industrial induction motor, power tools, electrical machinery etc.
Cable Standard Generally conforms to EN-50525-2-21, DIN VDE 0282 part 810,IEC 245 Cable Features - Special heat resistant insulation - High current carrying capacity - Less heat energy radiation - Longer life - High compatibility of cores - Excellent resistant to moisture, abrasion, grace, oil - Excellent mechanical & electrical properties - Insulation is highly thermal stable - Harmonized acc. to European standards Technical Data Working Temp : -25�?�°C to 70�?�°C Operating Temp : -20�?�°C to max. +90�?�°C Nominal Voltage : 450/750 V Test Voltage : 2500V Min. Bending Radius : 6 x cable Diameter Flame propagation : Flame retardant test as per IEC 60332-1-2 Standard Packing Coils 100, 200,500 and 1000m Conductor Flexible bare Class 5 copper conductor according to DIN VDE 0295,IEC 60228 Insulation Rubber Type El-4 to VDE 0282 Part-1 Sheath Neoprene Jacket Rubber Type EM-2 Color White, Black, Blue or as per customer order Core Identification 1 Core - Black 2 Core - Blue & Brown 3 Core - Yellow/green, Blue, Brown 4 Core - Yellow/green, Blue, Brown, Black or Yellow/Green, Brown, Black, Grey 5 Core - Yellow/Green, Blue, Brown, Black and Grey Application H07RN-F rubber insulated and sheathed cables are intended for flexible connection to electrical equipment. They are suitable for both indoor and outdoor use in industrial and agricultural plant and on construction sites
Cable Standard IS 694:2010, BS 6500, IEC 60227 Silent Features - Excellent flexibility - Excellent resistant to moisture, abrasion, grease, oil - Long Life - Excellent mechanical & electrical properties Technical Data Working Temp : Max.+70�°C Nominal Voltage : 1.1 KV Test Voltage : 3.0 KV Min. Bending Radius : 6 x Cable Diameter Standard Packing Coils 100, 200,300, 500, 1000m Conductor Flexible Bare Bunch Copper as per IS:8130 Insulation PVC As Per IS:5831 Outer Sheath PVC As Per IS:5831 Core Color As per IS: 694:2010 â?? 3C - Red, Yellow, Blue, 4C - Red, Yellow, Blue, Black As per IEC:60227 - 3C - Black, Blue, Brown. 4C - Black, Blue, Brown, Green or Yellow/Green Application Ideal For Irrigation Pumps, Drinking Water Supply Pumps, Submersible Pump Motor Power Supply
Cable Standard DIN VDE 0282 part 810, IEC 245 & BS 6007, BS 6899 Silent Features - Temperature range -40�° to +90�° - Exceptional long term performance - Excellent Impact Resistant - Excellent Weather Resistant Technical Data Operating Temp : -20�°c to Max.+90�°C Nominal Voltage : 1.1 KV Test Voltage : 3.0 KV Min. Bending Radius : 6 x Cable Diameter Standard Packing Coils 100, 200,300, 500, 1000m Conductor Flexible Bare Bunch Copper as per IS:8130, IEC 60228 Insulation EPR Rubber Outer Sheath EPR Rubber Core Color 3C - Red, Yellow, Blue, Or Black, Blue, Brown 4C- Red, Yellow, Blue, Black Or Black, Blue, Brown, Green or Yellow/Green Application Ideal For Irrigation Pumps, Drinking Water Supply Pumps, Submersible Pump Motor Power Supply.
Cable Standard Generally conforms to, Based on IS:9857-1990 VDE 0282, IEC 245-6, BS 6899 Silent Features - Ultra high performance flexible welding lead, double insulated for longer life and added safety - Better flame retardant properties - Outstanding toughness & durability - High resistance to cuts, tears & abrasion - Resistance to oil, solvents and chemicals - Excellent ozone and weather resistant Technical Data Fixed Installation : -20C to max.+90C Nominal Voltage : 600 V Spark Test : 3.5 KV(ac) Color : Orange / Black Jacket Min. Bending Radius : 6 x Cable Diameter Standard Packing Coils 100, 200, 300 and 500m Conductor High conductivity, bare annealed copper flexible conductor, EC copper class 5 & class 6 generally conforms to IS:8130-1984, IEC 60228 Separation Polyester tape Insulation Double Insulated/single insulated flexible Nitrile rubber HOFR insulated as per IS:6380-1984 Color Orange / Black Jacket Current Rating The maximum current ratings of flexible welding cables for different duly cycles are based on an ambient air temperature of 25 C and a maximum conductor temperature of 90 C. The percentage duly cycles for various processes and applications are as follows: - Automobile Welding : up to 100% - Semi Automatic Welding : 30% to 85% - Manual Welding : 0% to 60% - Very intermittent or Occasional Welding : up to 20% Voltage Drop When total cable lengths in excess of 15mtr., are involved, it may be necessary to use cables of larger cross section to ensure that the voltage drop is not excessive & welding currents are maintained at adequate levels. Application Designed for the secondary (high current) connection to automatic or hand - held metal arc welding electrodes. It is suitable for flexible use under rugged conditions, on assembly lines & conveyor systems, in machine tool and automatically operated line & spot welding machines
Electrical Characteristics - Rated Voltage : 0.6/1 kV AC - Rated DC Voltage : 1.5 kV - Maximum Permitted DC Voltage : 1.8 kV (conductor/conductor, non earthen system, circuit not under load) - Maximum Permitted AC Voltage : 1 KV - Working Voltage : DC 1000 V - Spark Test : 6000 V. ac (8400 Vdc) - Voltage Withstand : 6500 V as per EN50395 for 5 min - Ampacity : According to requirements for cables for PV systems Technical Data - Ambient Temperature : -40C +90C - Minimum Bending Radius : 5 x OD (fixed), 15 x OD (occasional flexing) - Flame retardant according to IEC 60332-1-2 - Low smoke emission < 20% as per ASTM D-2843 - Halogen free according to EN 50267-2-1/-2, IEC 60754-2 - Maximum Temperature at Conductor : 120C (20000h) - Short Circuit Temperature : 200�?�°C (at conductor max. 5sec) - Thermal Endurance Test : According to EN 60216-2 (temperature index +120C) - High Temperature Pressure : Test according to EN 60811-3-1 - Excellent mechanical and electrical properties. - UV resistance & OZONE resistance - Flexibility & suitability for fast & easy installation Cable Standard EN 50618 Standard Packing Coils 100, 200,300, 500, 1000m Conductor Flexible Electrolytic fine Tinned copper class-5 conductor according to IEC 60228 Insulation XLPO (Crosslinked Halogen Free & Flame Retardant) Sheath XLPO (Crosslinked Halogen Free & Flame Retardant) Color Red, Black and also available black color with red lining. Application For Solar Panel, Solar Power Plant, Solar Pump Installation.
Cable Standard BS:5308 (172) IEC 189 (1&2) Silent Features - Wear & Tear Resistance - Long Life - Easy to Cable Slitting - Fire Resistance Technical Data Working Temp : 70C / 90C / 105C as per Insulation Nominal Voltage : 300/500 V Application To Transmit signals from Field Instruments to Control Penal with No. disturbance. A.C. drive application Standard Packing Coils 100, 200, 500 & 1000m Conductor Annealed Plain Bare Copper or Tinned Copper As per IEC 60228 Insulation PVC/ XLPE/ PE/ LSZH/ EPR Sheath PVC/ Rubber/ LSZH/ FRLS Type Armoured or Unarmoured. Elements Insulated core/Pairs / Tried / Quads Color / multi core cable number marking on core Shield Aluminum mylar tape screen with tinned copper drain wire individual shielding or Overall Shielding Braiding Tinned copper braiding as per requirement Application To Transmit signals from Field Instruments to Control Penal with No. disturbance. A.C. drive application
Hot Pink Crystal Beaded Rosary Style Chain Sold by - Per Feet Approx. Wt. Per Feet - 2.80 gram Handmade Chain Made in India
Copper & aluminum armored/unarmoured lt power cable 3 core & 4 core pvc submersible flat/round cables 3 core & 4 core rubber submersible flat/round cables dewatering pump cable pvc insulated single core & multi core copper cables copper welding cables pvc insulated automobile cables pvc & rubber insulated battery cables polyester taped submersible winding wires. submersible winding wire copper earthing cables control cable crane cable marine cable shielded cables aluminum cables braided cables h07rn f cable h05vv f cable battery cable twin flat with earthing cable dc solar cable xlpe cable ptfe insulated wires silicone rubber cable optical fiber cable cat 6 cable pvc compound copper wire aluminum wire.
Model NO.: Multi Pairs Telephone Cable Conductor Dimension: 0.37mm/0.40mm/0.50mm, 24AWG Conductor Material: OFC/BC/CCA/CCS Insulation 1. Water blocking swellable tape (optional) 2. HD-PE (High density polyethylene) 3. 1.0mmHD-PE(Highdensity polyethylene) Number of Twisted Pair: 2P/5P/7P/10P/16P/20P/25P/30P/32P/ 50P/100P/150P/200P Shielding: UTP/Polyester Tape/Al Foil Ripcord: Yes with Nylon Jacket: PVC (Polyvinyl-Chloride)/ LSZH (Low Smoke Zero Halogen)/PE Separator: Mylar Spirally Wrapped Color: Different color is available Operating temperature: -20 C - +75 C Service Life: 20~25 years
Specification: 1,This cable is produced according to the standard BS6500,IEC60227:1993, VDE 0281 2,BS6360 Class 5,Solid or Stranded Bare Copper Conductor 3,BS7655 TI 1PVC Insulation 4,PVC Sheathed, color available Application: The cable is suitable to be fixed wireing of power device,power lighting of home electric equipment and instrument, inner wiring of electric enquipment Instrument, electron equipment, automatization device etc. Suitable for use in conduit and for fixed, protected installation of Wiring Burglar Alarm, Public Address Systems,Intercoms, Telephone Stations, Speakers, Instrumentation, Control and other Low Voltage Circuits that are Power Limited and anti-interference needed Product Feature: Linecorenumberand conductornominalsection Conductor Constructionn/mm Norminalthinkness ofinsulation(mm) Overall Diameter(mm) At20DCResistanceof conductor(Ω/km) 1.5 30/0.25 0.7 3.05±0.05 13.3 2.5 77/0.20 0.8 3.65±0.05 7.98 4.0 56/0.30 0.8 4.25±0.08 4.95 6.0 84/0.30 0.8 5.25±0.08 3.30 Factory Presentation&Certificate
Specification: 1,This cable is produced according to the standard BS6500,IEC60227:1993, VDE 0281 2,BS6360 Class 5,Solid or Stranded Bare Copper Conductor 3,BS7655 TI 1PVC Insulation 4,PVC Sheathed, color available Application: The cable is suitable to be fixed wireing of power device,power lighting of home electric equipment and instrument, inner wiring of electric enquipment Instrument, electron equipment, automatization device etc. Suitable for use in conduit and for fixed, protected installation of Wiring Burglar Alarm, Public Address Systems,Intercoms, Telephone Stations, Speakers, Instrumentation, Control and other Low Voltage Circuits that are Power Limited and anti-interference needed Product Feature: Linecorenumberand conductornominalsection Conductor Constructionn/mm Norminalthinkness ofinsulation(mm) Overall Diameter(mm) At20DCResistanceof conductor(Ω/km) 1.5 30/0.25 0.7 3.05±0.05 13.3 2.5 77/0.20 0.8 3.65±0.05 7.98 4.0 56/0.30 0.8 4.25±0.08 4.95 6.0 84/0.30 0.8 5.25±0.08 3.30 Factory Presentation&Certificate
Specification: 1,This cable is produced according to the standard BS6500,IEC60227:1993, VDE 0281 2,BS6360 Class 5,Solid or Stranded Bare Copper Conductor 3,BS7655 TI 1PVC Insulation 4,PVC Sheathed, color available Application: The cable is suitable to be fixed wireing of power device,power lighting of home electric equipment and instrument, inner wiring of electric enquipment Instrument, electron equipment, automatization device etc. Suitable for use in conduit and for fixed, protected installation of Wiring Burglar Alarm, Public Address Systems,Intercoms, Telephone Stations, Speakers, Instrumentation, Control and other Low Voltage Circuits that are Power Limited and anti-interference needed Product Feature: CONDUCTOR INSULATION COVERING MAX.COND. RESISTANCE (Ω/km,20°C,DC) DIELECTRIC STRENGTH (VAC,1min) AWG CONSTR- UCTION (No./mm) DIA. (mm) INSULATION THICKNESS (mm) O.D. (mm) JACKET THICKNESS (mm) O.D. (mm) 28 7/0.127 0.38 0.46 1.30 0.40 2.10 239 2,000 26 7/0.16 0.48 0.46 1.40 0.40 2.20 150 2,000 24 11/0.16 0.61 0.49 1.60 0.40 2.40 94.2 2,000 22 17/0.16 0.76 0.47 1.70 0.40 2.50 59.4 2,000 20 26/0.16 0.94 0.48 1.90 0.40 2.70 36.7 2,000 18 41/0.16 1.18 0.46 2.10 0.40 2.90 23.2 2,000 16 26/0.254 1.49 0.46 2.40 0.40 3.20 14.6 2,000 14 41/0.254 1.88 0.46 2.80 0.40 3.60 8.96 2,000 Factory Presentation&Certificate
Specification: 1,This cable is produced according to the standard BS6500,IEC60227:1993, VDE 0281 2,BS6360 Class 5,Solid or Stranded Bare Copper Conductor 3,BS7655 TI 1 PVC Insulation 4,PVC Sheathed, color available Application: The cable is suitable to be fixed wireing of power device,power lighting of home electric equipment and instrument, inner wiring of electric enquipment Instrument, electron equipment, automatization device etc.  Suitable for use in conduit and for fixed, protected installation of Wiring Burglar Alarm, Public Address Systems,Intercoms, Telephone Stations, Speakers, Instrumentation, Control and other Low Voltage Circuits that are Power Limited and anti-interference needed Product Feature: Model No. Conductor Insualtion Jacket Cores � Nom. Area Max. Resistance at 20°C Thickness Min. Resistance at 70°C Thickness Min. Dia. Max.  mm² MΩ/km mm MΩ/km mm mm mm RVV2�0.75 2�0.75 26 0.6 0.011 0.8 6 7.6 RVV2�1.0 2�1.0 19.5 0.6 0.01 0.8 6.4 8 RVV2�1.5 2�1.5 13.3 0.7 0.01 0.8 7.4 9 RVV2�2.5 2�2.5 7.98 0.8 0.009 1 8.9 11 RVV3�0.75 3�0.75 26 0.6 0.011 0.8 6.4 8 RVV3�1.0 3�1.0 19.5 0.6 0.01 0.8 6.8 8.4 RVV3�1.5 3�1.5 13.3 0.7 0.01 0.9 8 9.8 RVV3�2.5 3�2.5 7.98 0.8 0.009 1 9.6 12 RVV4�0.75 4�0.75 26 0.6 0.011 0.8 6.8 8.6 RVV4�1.0 4�1.0 19.5 0.6 0.01 0.9 7.6 9.4 RVV4�1.5 4�1.5 13.3 0.7 0.01 1 9 11 RVV4�2.5 4�2.5 7.98 0.8 0.009 1.1 10.5 13 RVV5�0.75 5�0.75 26 0.6 0.011 0.9 7.4 9.6 RVV5�1.0 5�1.0 19.5 0.6 0.01 0.9 8.3 10 RVV5�1.5 5�1.5 13.3 0.7 0.01 1.1 10 12 RVV5�2.5 5�2.5 7.98 0.8 0.009 1.2 11.5 14 Factory Presentation&Certificate FAQ Q1. What kind of products can your company supply?  A: We specialize in supplying network cable, coaxial cable, HDMI cable, VGA cable, telephone cable, speaker cable and ect.  Q2. What's your MOQ? A: The MOQ of long meter cable is 50 km, or we can negociate.  Q3. What's your delivery time? A: Our delivery time is about 15-20 days after comfriming the deposite, it is based on the quantity of the order.  Q4. What are your payment terms? A: Normally, we accept T/T in advance, as for other payment term, we can negociate with you.  Q5. What's your trade term ? A: We can accept FOB, CIF, EXW term.   Q6. What's your conventional packing ? A: 100m/plastic or wooden drum, 305m/wooden drum or color box. However, we can produce according your demand.  Q7. Can your factory customize cables based on clients' samples or data sheet ?  A: Yes, we can .
Grain length: 8.1 mm, before cooking Purity: 90% Sortex: 100% Admixture: 10 % Broken: 1% max (2/3 basis) Foreign matter: 0.25% max Damaged & discolored: nil Black grains: nil Moisture: 13% max Free from live or dead weevils Free from dust & stones
Grain length: 8.1 mm, before cooking Purity: 90% Sortex: 100% Admixture: 10 % Broken: 1% max (2/3 basis) Foreign matter: 0.25% max Damaged & discolored: nil Black grains: nil Moisture: 13% max Free from live or dead weevils Free from dust & stones
32mm x 32mm x 3.2mm having weight of 2.69kg/mtr. (iii) For Chain Link (inner) Frame: MS Angle of 25mm x 25 mm 3mm having weight of 1.1kg/mtr. (iv) For Chain Link Mesh: GI wire of 10 SWG with minimum 40 microns coating of Zink & fabrication of mesh of 2 x 2 with approx. weight 3kg/Sq.