Profile A certain amount of water as defined by meter body passing through makes piston move. The measuring structure records its movements. Movements times defined amount making total amount of water passed registered. Features 1. Rotary piston structure. It registers total amount of water passed in the tube by calculating how many times the piston rotates. 2. Dry and wet type are both separated from water so as to keep the registering clear. 3. Registering is stable and high-graded measurement. Easy to install. 4. Long endurance with no rotating inclination and long work life. 5. Various types available to register pure water or to be installed in any position. 6. Remote transmission device can be added upon request. 7. Different structures and specifications with beautiful appearances are available. 8. Meter bodies can be of copper, SS or plastic. 9. All technical figures are conformed with GB/T778.1~3-1996 which is equivalent to IS04064 Standard Class C. Working condition L Water temperature≤ 45º C L Water pressure≤ 1Mpa (≤ 0.6Mpa for LXH-8S). Maximum permissible error L From the minimum flow-rate (qmin ) inclusive to the lower zone of the transitional flow-rate (qt ) exclusive: ± 5%.
Medical mask; Blood Glucose Meter.
Electrical measuring instruments, meters, volt meters, current transformers.
Meter, multimeter, clamp meter, light meter, sound level meter, thermometer, shunt, voltage detector.
Multi Function Blood Glucose Meter.
SYSTEM INFORMATION The electromagnetic flow meter HMF 2110 series is the most common and highly accurate flow measurement device that can be universally used in various measurement fields. Since there is no driving part like a propeller, no trouble is caused due to pressure loss, and the durability is excellent In addition, since the installation is simple with the flange type, even a beginner can easily install it through simple training. The sensor measures the flow rate by direct contact with the fluid,, thus a more reliable flow rate value can be obtained, and the reproducibility is also excellent If you are looking for a flowmeter that can be used with confidence, choose the HMF 2110 series without hesitation. â?? KEY FEATURES Quick Start Self diagnostic Easy Maintenance â?? CHARACTERISTICS â?¢ Due to high stability, popular for water flow measurement â?¢ Excellent durability due to no driving part â?¢ Electrode and lining materials are selected for measuring chemical flow â?¢ There is no pressure drop, which reduces electricity costs. â?? SPECIFICATIONS * Sensor installation method : Flange mounting type (Standard: JIS, DIN, ANSI, etc.) * Accuracy : �±0.2% (flow rate 0.1 m/s or more)0.2% (flow rate 0.1 m/s or more) * Max Minimum Flow : 0.05 m/s ~ 10 m/s (Flow rate by diameter) * Measuring pipe caliber : 6 mm ~ 2,000 mm * Measurable fluid : Water, sewage, wastewater, chemicals, etc. (Conductivity of 5�¼S /cm or more) * Power : 110 ~ 220 V AC / 60 Hz * Operating temperature : Sensor (40 ~ 70 â??), Operation: (18 ~ 60 â??) * Screen display contents : LCD Size: LCD Display 100 x 55, 3 Line, 16 Characters, Instantaneous flow rate (4 digit), accumulated flow rate (9 digit), pressure (4 digit) * Flow display unit : Unit: m3, L, etc. / Directions: Forward & Reverse (-) * Electrode : Hastelloy C * Liner: NBR, Hard Rubber, EPDM * Flange : Carbon Steel * Flow measurement frequency : 1.875 ~ 12.5 Hz * Sensor cable length : 100m * Output signal : 4 ~ 20 mA, Integrated pulse active , Passive (Max 10 kHz), Relay pulse (Max Load 24 V DC / 1A) * Communication and memory : RS 232, RS 485 Modbus 128 Mbyte internal memory: date, time, instantaneous flow rate, accumulated flow rate, Pressure memory interval: 5 seconds ~ 24 hours * Protection class : Sensor unit: IP 68 / Operation unit: IP 65 * Self diagnosis function : Alarm display when empty pipe information and self diagnosis error occur For more details on quality Korean flowmeters, please feel free to visit http://www.hnl-global.com/flowmeter and contact us.
System Information The electromagnetic flow meter HMF 2110 series is the most common and highly accurate flow measurement device that can be universally used in various measurement fields. Since there is no driving part like a propeller, no trouble is caused due to pressure loss, and the durability is excellent In addition, since the installation is simple with the flange type, even a beginner can easily install it through simple training. The sensor measures the flow rate by direct contact with the fluid,, thus a more reliable flow rate value can be obtained, and the reproducibility is also excellent If you are looking for a flowmeter that can be used with confidence, choose the HMF 2110 series without hesitation. â?? KEY FEATURES Quick Start Self diagnostic Easy Maintenance â?? CHARACTERISTICS â?¢ Due to high stability, popular for water flow measurement â?¢ Excellent durability due to no driving part â?¢ Electrode and lining materials are selected for measuring chemical flow â?¢ There is no pressure drop, which reduces electricity costs. â?? SPECIFICATIONS * Sensor installation method : Flange mounting type (Standard: JIS, DIN, ANSI, etc.) * Accuracy : �±0.2% (flow rate 0.1 m/s or more)0.2% (flow rate 0.1 m/s or more) * Max Minimum Flow : 0.05 m/s ~ 10 m/s (Flow rate by diameter) * Measuring pipe caliber : 6 mm ~ 2,000 mm * Measurable fluid : Water, sewage, wastewater, chemicals, etc. (Conductivity of 5�¼S /cm or more) * Power : 110 ~ 220 V AC / 60 Hz * Operating temperature : Sensor (40 ~ 70 â??), Operation: (18 ~ 60 â??) * Screen display contents : LCD Size: LCD Display 100 x 55, 3 Line, 16 Characters, Instantaneous flow rate (4 digit), accumulated flow rate (9 digit), pressure (4 digit) * Flow display unit : Unit: m3, L, etc. / Directions: Forward & Reverse (-) * Electrode : Hastelloy C * Liner: NBR, Hard Rubber, EPDM * Flange : Carbon Steel * Flow measurement frequency : 1.875 ~ 12.5 Hz * Sensor cable length : 100m * Output signal : 4 ~ 20 mA, Integrated pulse active , Passive (Max 10 kHz), Relay pulse (Max Load 24 V DC / 1A) * Communication and memory : RS 232, RS 485 Modbus 128 Mbyte internal memory: date, time, instantaneous flow rate, accumulated flow rate, Pressure memory interval: 5 seconds ~ 24 hours * Protection class : Sensor unit: IP 68 / Operation unit: IP 65 * Self diagnosis function : Alarm display when empty pipe information and self diagnosis error occur For more details on quality Korean flowmeters, please feel free to visit http://www.hnl-global.com/flowmeter and contact us.
Blood glucose meters, strips, medical equipment.
Memory128 with date/time FunctionIrregular heartbeat detection (ihd) Measure range0 - 300mmhg Pulse rate40 - 200/minute ScreenLarge lcd display date/time, systolic, diastolic and pulse rate Size & weightSize/weight - 75x67x30mm/140g (included battery) PowerBattery ""aaa""x2, 3v dc AccessoriesCuff, instruction manual, storage case Packing20pcs/carton/5.8kg/42.2x40.2x14.2cm; 22, 000pcs/20ft; 44, 800pcs/40ft Packing20pcs/carton/5.8kg/42.2x40.2x14.2cm; 22, 000pcs/20ft; 44, 800pcs/40ft
Medical devices, blood pressure monitor, blood glucose meter, digital thermometer, oximeter, ECG, doppler, stethoscope, nebulizer.
Car modification engine parts, cam pulley, ignition coil, ignition wire, crank pulley, meters, adjustable fuel regulator set, adjustabe suspension and enlarge racing brake system.
Blood pressure monitor, infrared thermometer, fetal doppler, pulse oximeter, hearing aids, glucose meter etc..
INTENDED USE The Malaria Gold Rapid Test is a lateral flow chromatographic immunoassay for the simultaneous detection and differentiation of antibodies including IgG, IgM and IgA to Plasmodium falciparum (Pf) and vivax, ovale, and malariea (Pv.o.m) in whole blood. This device is intended to be used as a screening test and as an aid in the diagnosis of infection with Plasmodium. Any reactive specimen with the Malaria Gold Rapid Test must be confirmed with alternative testing method(s) and clinical findings. REAGENTS AND MATERIALS PROVIDED 1. Each kit contains 25 test devices, each sealed in a foil pouch with three items inside: a. One cassette device. b. One plastic dropper. c. One desiccant. 2. Sample diluent (1 vial, 5 ml) 3. One package insert (instruction for use). MATERIALS REQUIRED BUT NOT PROVIDED 1. Clock or Timer 2. Lancing device for whole blood test
Blood glucose meter.
450 memories, 5 sec., 7/14/28 average record. 0.5 micro-liter sample blood. Clock alarm Temperature change, measurement unit change. ***accurate , stable, mature *** 42g.
Dr. Odin Accugence is a multi-monitoring system for 4 in 1 testing. This product offers a simple and effective solution for your demand of testing with clinically proven accuracy, fast test time, and tiny sample volume in one system. It can test Blood Glucose Level (GOD/FAD-GDH), Uric Acid Testing and Blood Ketone Testing. Features: 4 in 1 testing 5 range indicators Easy strip ejection Auto strip recognition Care: To use twist-off the protective cap Smooth, polished surface for reduced friction during penetration Guaranteed sterility to fulfill hygienic requirements Read the manual carefully before use Use under medical supervision Keep out of the reach of children Lancet is for single use only Additional Info: Model number: NA Warranty: Lifetime Easy to use Our lancets have an advanced glide control system for convenient use Made from natural & super-fine round points to ensure a less painful prick
Features: 1. Bargraph and/or digital displays 2. Single or dual channel 3. Transmitter power supply for 2-wire loop powered input 4. Variety of input types 5. Non-linear tank volume calculation, retransmission output and relay outputs available 6. Horizontal or vertical orientation
Medical disposables, blood pressure monitors, thermo meters, glucose meters.Broker services
Electromagnetic Flowmeter.
We have several different products. We are esclusive distributor of Polygreen brand (thermometer,blood pressure,baby articles and medical devices). Our companies is on of the biggest manufacture in the world. We are searching for distributors in Europe.