Product description The Transformer short circuit impedance tester comes with an adjustable power output. Regardless of single phase or three phase transformers, only one connection is required, and the instrument can complete the measurement of all winding pairs. The test and connection are simple. Main technical indicators and conditions of use Measurement accuracy voltage, current 0.2 level Power COS 0.1 0.5 grade, COS 0.1 1.0 grade Impedance COS 0.1 0.5 grade COS 0.1: 1.0 grade Voltage measurement range AC 3V 300V Internal power output range voltage 0 250V, current 0 10A Current measurement range AC 0.2A 20A Working temperature 10 50 Working humidity 0 80 Working power supply AC220V 10 50Hz 1Hz Dimensions 360mm 220mm 150mm Weight of the instrument 20Kg Transformer Short circuit Impedance Tester
Product description The Transformer short-circuit impedance tester comes with an adjustable power output. Regardless of single-phase or three-phase transformers, only one connection is required, and the instrument can complete the measurement of all winding pairs. The test and connection are simple. Main technical indicators and conditions of use Measurement accuracy: voltage, current: 0.2 level Power: COS>0.1: 0.5 grade; COS 0.1: 1.0 grade Impedance: COS>0.1: 0.5 grade; COS 0.1: 1.0 grade Voltage measurement range: AC 3V300V Internal power output range: voltage 0~250V, current 0~10A Current measurement range: AC 0.2A 20A Working temperature: -10-50 Working humidity: 80% Working power supply: AC220V ±10-50Hz ±1Hz Dimensions: 360mm 220mm 150mm Weight of the instrument: 20Kg
Product description The Transformer short-circuit impedance tester comes with an adjustable power output. Regardless of single-phase or three-phase transformers, only one connection is required, and the instrument can complete the measurement of all winding pairs. The test and connection are simple. Main technical indicators and conditions of useï¼? Measurement accuracy: voltage, current: 0.2 level Power: COS>0.1: 0.5 grade; COS 0.1: 1.0 grade Impedance: COS>0.1: 0.5 grade; COS 0.1: 1.0 grade Voltage measurement range: AC 3V300V Internal power output range: voltage 0~250V, current 0~10A Current measurement range: AC 0.2A 20A Working temperature: -10-50 Working humidity: 0-80% Working power supply: AC220V 10-50Hz1Hz Dimensions: 360mm-220mm 150mm Weight of the instrument: 20Kg
Product description Current transformer field tester was developed with high-end testing technology, large-scale electronic circuit design and accord with national related protocol . It has solved the problem of big working intensity,trival operation while on-site test of current transformer, voltage transformer. Meanwhile the product has a reliable performance,and the function is strong. Technical index Test range: 5A5A~25000A5A or 5A1A~5000A1A Tested current transformer work scope: 1% 120% Second load 2.5 VA 300VA, COS 0.8 1.0 Be tested current transformer accuracy range 1.0, 0.5, 0.5 S, 0.2 and 0.2 S Resistance, admittance measurement errors 5.0% Measurement range R 0.00 ~20.0 Y 0.000mS~100.0 mS Power consumption 20 VA Accuracy level 0.05 S level Shape dimension mm 460 L 375 W 183H Weight kg 10 Feature HCCT-H Current Transformer Field Tester with recursive method to measure current transformer error, as well as potential difference method to measure voltage transformer error function, convenient for carrying out calibration work of field metering device. HCCT-H Current Transformer Field Tester without using Standard Current Transformer, Current Source, Load Box, Double Adjustable Control Box and Primary cable, using extremely simple test connection and operation to realize the current transformer test, greatly reduce work intensity and improve the work efficiency, convenient to carry out current transformer field test work.
Product description The current booster is used on checking current transformer,to be the power source supply once current for current transformer or to be other 50Hz single phase current source device. Technical index Temperature Humidit Capacity: 20kVA Specification Weight: 75Kg Allow long-term work on the rated current Allowable overload 1.5 times,30 minutes of continuous work. Feature This PSLLQ is make up of input Winding(220V), output winding below 100A and CXRZ. Output current indicated on the nameplate is defined the rated current that through winding allow to pass.When CX many circles, the rated current its permitted to pass through will inversely decline. The value which ouput capcity divided by product of output current and each circle voltage was the biggest circle number allowing. The current booster is designed to provide the primary current power supply for the current transformer when verifying the current transformer or as other 50HZ single-phase power equipment. The current booster for transformer verification is suitable for power departments such as power testing, power measurement, and power maintenance. The current booster is developed and produced according to the industry standard of transformer error testing, and is used as a current transformer to verify the primary current of the current transformer. The output current can be customized according to customer requirements. The lifter is equipped with casters for easy on-site movement.
Product description Current transformer field tester was developed with high-end testing technology, large-scale electronic circuit design and accord with national related protocol . It has solved the problem of big working intensity,trival operation while on-site test of current transformer, voltage transformer. Meanwhile the product has a reliable performance,and the function is strong. Technical index
V-checker circuit tester
Overview Generator Rotor AC Impedance Testing Instrument is a special instrument for determining whether the turn-to-turn short circuit exists in the generator rotor winding, and can manually and automatically unidirectionally or bidirectionally measure many parameters of the generator rotor such as voltage, current, impedance, power and rotating speed.Generator Rotor AC Impedance Testing Instrument is the latest enhanced AC impedance tester launched by our Company. The instrument adopts the state of the art high speed microprocessor technology with more powerful functions, preferable performances and more convenient use. The Tester has a series of characteristics such as high reliability, easy operation, high test precision, being compact and lightweight and etc., and currently is in the domestic leading level. Major Technical Indicators Temperature 5 C 40 C Relative Humidity 0 1 FS2d Cos 0.1 0.5 FS2d 1kW 72KW 0.1 Cos 0 1 FS2d Cos0.1 0.5 FS2d Frequency 40-75HZ 0.2 Volume 415 225 200mm
Transformer Capacity and Loss Tester Transformer Oil Tester I Introduction Transformer Capacity Testing Instrument is specialized in bad power users evading basic electricity secretly adds capacity problems and is a high precision instrument specially used for the measurement of the transformer capacity and parameters. This product uses color LCD monitor, English display, simple and quick menu operation, man-machine interface is friendly. The internal of the instrument has a rechargeable battery and it can work without external power source. A fully charged battery can be continuously measured more than 100 sets. In addition, the instrument can provide three-phase precise 50Hz sine wave AC test power without the external three-phase test power, the pressure regulator, up flow reactor and other auxiliary equipment in measuring the capacity and transformer load loss, thus greatly improving the efficiency of the work. This is a multi-functional measuring instrument, which is equivalent to two common devices: activity transformer capacity tester and transformer parameter tester. It can be used for test transformer capacity, model, no-load current, no-load loss, load loss, impendence voltage and so on. This product has many advantages such as small, light , high accuracy, stability, simple operation and so on. It can replace the multi-meter method to measure the transformer loss and capacity with simple wiring and convenient testing so that the work efficiency can be greatly improved. Function 1. We can measure a variety of distribution transformer, power transformer capacity instead of the additional power. It is more convenient and efficient. 2.Combined with the power, voltage, boost up flow and other equipment, it measures various transformer no-load current, no-load loss, impedance voltage, load loss and so on. 3.All results are automatically carried out relevant correction. You only need to input the related parameters (such as temperature, load adjustment coefficients), then the instrument can automatically correct such as waveform deformity correction, temperature correction, correction of non rated voltage, rated current correction. 4.The maximum voltage is up to 750V and the maximum current is up to 100A. It is equipped with protection circuit. 5.The voltage and current range can be very flexible and easy to expand. 6.It has large screen, high brightness LCD display, English menu and operation tips, friendly man-machine interface and wide temperature, brightness adjustable type LCD screen, which can adapt to the different temperature.
This instrument is designed for testing DC circuit breakers at rated current of 1A-500A. 1. The instrument can be used separately or linked to PC. 2. 320*240 LCD screen thermal printer interactive keyboard operation and intelligent operation system. 3. Power electronics controlling technique has been adopted to output high current with high speed high precision and continuous adjustability. 4. Current range can be automatically switched by multiple high precision sensors.14 digit AD acquisition chip of high capacity. 5. Automatic data storage. Be capable of saving 200 testing results which will not lose in power failure. 6. Two options: ampere-second characteristic test or through current characteristic test. 7. When linking to PC it is available to do following operations such as controlling the instrument data importing data saving data report and data graph generation. 8. Protection functions for overheat over-current and over voltage. 9. Anti-interference capacity and good EMC(electromagnetic compatibility).
This instrument is designed for testing DC circuit breakers at rated current of 1A-500A. 1. The instrument can be used separately or linked to PC. 2. 320*240 LCD screen thermal printer interactive keyboard operation and intelligent operation system. 3. Power electronics controlling technique has been adopted to output high current with high speed high precision and continuous adjustability. 4. Current range can be automatically switched by multiple high precision sensors.14 digit AD acquisition chip of high capacity. 5. Automatic data storage. Be capable of saving 200 testing results which will not lose in power failure. 6. Two options: ampere-second characteristic test or through current characteristic test. 7. When linking to PC it is available to do following operations such as controlling the instrument data importing data saving data report and data graph generation. 8. Protection functions for overheat over-current and over voltage. 9. Anti-interference capacity and good EMC(electromagnetic compatibility).
Product Introduction TKBB-S Transformer Ratio Tester is specially designed for three- phase transformer in power system especially for transformer of type Z winding and other transformers whose zero-load current is relatively high.Transformer turns ratio test is very important in order to find out the transformer has the right ratio corresponding on its rated voltage in primary and secondary. TKBB-S is single phase, automatically test set specially designed for turns ratio, phase shift and excitation current measurements of power, distribution and instrument transformer. The tester has wide testing range fast testing speed favorable repeatability flexible data processing convenient connection complete protection easy learning and convenient operation
Rated power: 1-5KW Pure sine wave output Smart LCD setting (Working modes, Charge Current, Charge Voltage, etc). Bult in MPPT 60A/80A solar charge controller Combining solar system, AC utility, and battery power source to supply continuous power Overload, short circuit and Deep discharge protection Cold start function Support USB, RS485 monitoring function WIFI remote monitoring (optional) Compatible to generator Support parallel operation up to 3 units (available for 3KW-5KW 48V) This is a multi-function inverter/charger, combining functions of inverter, MPPT 60A/80A solar charger and battery charger to offer uninterruptible power support with portable size. Its comprehensive LCD display offers user-configurable and easy-accessible button operation such as battery charging current, AC/solar charger priority, and acceptable input voltage based on different applications.
Automatic circuit breaker tester UPA-3 is designed for testing and ampere-second characterization of automatic AC current circuit breakers. The device allows registering the value of the supplied current and timing the automatic circuit breaker switching interval. Circuit breaker tester UPA-3 is a mobile device, which could be easily transported to a required testing location. Circuit breaker tester UPA-3 operates on the principle of varying the power in the primary circuit of the matching power transformer and, respectively, varying the output current, flowing through the automatic circuit breaker under the test. Power regulation could be done either through an external regulator (RNO or VR) or through a built-in thyristor controller.
SANDI SERIES charging module is for electric vehicle charging station. With single-phase non neutral conductor AC input, it has the advantages of high efficiency, high power density and low harmonic. Functional details 1. Hot plug Plug technology is applied to the charging module to provide convenience for installation and maintenance. The access of the charging module to the system shall not disturb the output voltage of the system. 2. Advanced current sharing technology Under constant voltage working mode, the charging modules can share current automatically within 10S, with degree of unbalance less than �±0.5A. 3. Control of input limited power Refer to Fig. 1-10 for the relation between the output power and input voltage of the charging module. When the input voltage is within 360 Vac ~ 450 Vac (return difference is less than 5V), the module can output the maximum power of 20 KW; when the input voltage is within 260 Vac ~ 320 Vac, the module can still work normally under limited power mode. 4. Control of output constant power When there is a rated input voltage, the output power of the module is 20 KW. Refer to Fig. 11 for the relation between the output voltage and the output current of the module. The SD75050 module uses two operating modes with output voltage ranges of 50 to 750V. The module only selects the operating mode based on the value of the received demand voltage, and does not select the operating mode based on the actual output voltage. 5. Temperature limited power 6. Regulation of output current limiting point 8. Regulation of output voltage The output voltage of the module can be regulated constantly through the external monitoring module, with regulation range of 50Vdc ~ 750Vdc and minimum regulation step of 0.1 Vdc. 9. Fan control The built-in processor of the module can regulate the speed of the fan according to the internal temperature and output current of the module. 10. Protection of input overvoltage/ voltage shortage 11. Output overvoltage protection The overvoltage protection point is 260Vdc ~770Vdc (�±10 Vdc). Default is 778Vdc.The module can be started after manual intervention upon overvoltage protection. 12. Over-temperature protection The environmental over-temperature protection point is 80�°C. When the DC panel has a temperature over 100�°C, the module will stop working; when the DC panel has a temperature below 90�°C, the module will automatically work again. 13. Protection of internal bus fault When the internal bus voltage of the module is beyond the overvoltage/ voltage shortage protection point, the module will be powered off automatically. At this time, there is no output from the module and the fault indicator light is on. 14. Short circuit protection In case of short circuit of the module, it will be subjected to protective shutdown and the red indicator light of the panel is on, and this condition will be transmitted to the monitor of the "module fault".
TKBB-S Transformer Ratio Tester is specially designed for three- phase transformer in power system especially for transformer of type Z winding and other transformers whose zero-load current is relatively high.Transformer turns ratio test is very important in order to find out the transformer has the right ratio corresponding on its rated voltage in primary and secondary. TKBB-S is single phase, automatically test set specially designed for turns ratio, phase shift and excitation current measurements of power, distribution and instrument transformer.
The on-load tap changer is the only moving part connected with the transformer circuit so more and more attention has been paid to the detection of the on-load tap changer.In the electrical equipment handover and preventive test regulations it is required to check the action sequence of on-load tap changer measure switching time etc.This device is mainly used for measuring the transition waveform transition time transient resistance of transformer on-load tap changer three-phase synchronism etc. product names On - load tap - changer tester transformer on - load tap - changer tester transformer on - load switch tester
High voltage insulation equipment, transformer tester, circuit breaker, switch tester.Export, research and development
GF1061PT is the first portable device (4.8 kg) which offers highly accurate voltage transformer tests. This allows to use GF1061PT not only for electrical performance checks, but also for class verification and calibration. It performs quick tests of all kinds of inductive voltage transformers (VTs or PTs) and capacitive voltage transformers (CVTs) for both protection and metering purposes. Its lightweight design makes it ideal for on-site tests and calibration tasks in power system grids. Accuracy 0.02% Power supply AC 220V±10% or AC 120V±10%, 50/60Hz or Battery Output voltage 0-100Vrms Output current 0-5Arms (20A peak-value) Output power 0-400 VA (1500 VApeak) Automatic frequency variation range 0.1-60Hz Equivalent excitation voltage â?¤5000V/50KV Accuracy â?¤0.5% Secondary winding DC resistance measurement Range 0.1-1000�© Accuracy â?¤0.05% Secondary actual load measurement Range 5VA-1000VA Accuracy â?¤0.5%�±0.1VA PT phase error measurement Accuracy ±1min (typical) / 3 min (guaranteed) Resolution 0.1min PT ratio error measurement Range 1-15000 Accuracy 0.05% LCD display 7' inch TFT touch color LCD Communication port USB port Printer Yes, Thermal printer
GDKF Transformer Load and No Load Tester Introduction: It's used to Measure the transformer load and no load current, load and no load loss, short-circuit voltage, short circuit (load) losses and capacity. Test items: RMS phase voltage Average value of three-phase AC voltage Three-phase current RMS Percentage of no-load loss and no-load current Load loss, impedance voltage, and the percentage of short-circuit impedance Any given temperature, load loss, the percentage impedance voltage and short circuit impedance Voltage waveform in the percentage of each harmonic component Current waveform in the percentage of each harmonic component Technical index: Current measurement range: 100mA ~ 5A, accuracy class 0.2; Voltage Range: 10V ~ 650V, accuracy class 0.2; External transformer can broaden the scope of measurement instruments; Frequency Range: 40 ~ 65Hz, accuracy class 0.2; Power Input: AC220V ± 10% Company Information Our company has become one of the leading manufacturer of petroleum testing instrument and electrical testing instrument since 2009sâ??. We have developed sales channels in many countries such as Malaysia,India,Germany,USA,Mexico,Saudi Arabia,South Africa and other countries worldwide. and we have gained great advantage and high reputation in international market. We are making effort to develop together with customers from both domestic and abroad on the basis of reciprocity.Client,quality and service are our supreme target. Our Services Pre-sale Service: Inquiry will be replied within 24 hours. Welcome to visit our factory. Technical datas and operation manual sent for evaluation. After-sale Service: Training how to instal the machine, training how to use the machine at our factory; Engineers available to service machinery overseas at customers' cost;GDKF Transformer Load And No Load Capacity Characteristic Tester