Microfocus Fusion 5 X-ray Machine Suitable for SMT and semiconductor components
DESCRIPTIOn: Titanx100 RADIOGRAPHY RATING: 25-100mA, stations 45kVp to 100 kVp in 15 steps OUTPUT: 8KW RECTIFICATION: Full Wave Rectified TIMER: 0.06 to 5 sec DIGITAL DISPLAY : Digital Display of mAs, kV & mA X-RAY TUBE: XD-3/Imported POWER SUPPLY: 230 Voltage AC, 15 Amps LINE REGULATION: 10% 0.6max PROTECTION: Electronic overload Protection TUBE STAND counter Balance Mobile
DESCRIPTION: Titanx RADIOGRAPHY RATING: 25-100mA, stations 45kVp to 100 kVp in 15 steps OUTPUT : 8KW RECTIFICATION: Full Wave Rectified TIMER: 0.06 to 5 sec DIGITAL DISPLAY: Digital Display of mAs, kV & mA X-RAY TUBE: XD-3/Imported POWER SUPPLY: 230 Voltage AC, 15 Amps LINE REGULATION: 10% 0.6max PROTECTION: Electronic overload Protection TUBE STAND: Floor to Ceiling Column Stand
DESCRIPTION: Titanx100 RADIOGRAPHY RATING: 25-100mA, stations 45kVp to 100 kVp in 15 steps OUTPUT : 8KW RECTIFICATION: Full Wave Rectified TIMER: 0.06 to 5 sec DIGITAL DISPLAY: Digital Display of mAs, kV & mA X-RAY TUBE: XD-3/Imported POWER SUPPLY: 230 Voltage AC, 15 Amps LINE REGULATION: 10% 0.6max PROTECTION: Electronic overload Protection TUBE STAND: Counter Balance Mobile
DESCRIPTION- TITANX 100 RADIOGRAPHY RATING- 25-100mA, stations 45kVp to 100 kVp in 15 steps OUTPUT 8KW RECTIFICATION- Full Wave Rectified TIMER- 0.06 to 5 sec DIGITAL DISPLAY- Digital Display of mAs, kV & mA X-RAY TUBE- XD-3/Imported POWER SUPPLY- 230 Voltage AC, 15 Amps LINE REGULATION- 10% 0.6max PROTECTION- Electronic overload Protection TUBE STAND- Spring Balance
X ray machines, Mammography machines, digital Xray, OPG machines, C Arm, dental Xray, Portable X ray.Manufacturing and export
PLX101 Series High Frequency Mobile X-ray Equipment PLX101/101A/101C Rocker safety lock design, make your operate much safer High quality x-ray monoblock assures more details, less dose Symmetrical adjustable collimator for accurate positioning and better exposure protection Aviation aluminum connectors, connection reliable, more safety Advanced dislocation braking system, flexible movement, flexible braking Multifunctional cassette storage box design Features Our high frequency technology assures the best image in every operating condition Along with reduced patient dose and extended x-ray tube life time The generator provide the right amount of penetration, reducing exposure times and retakes. The parameter can be adjusted by the kV and mAs. Multiple security protect function such as over-voltage, over-current. 50 preset exposure programs allow extensive possibilities to optimize the exposure and processing parameters according to your preferences. Fault automatic protection setting and fault alarming display Parameters are automatically storage when power cut off. Adopt rotating beam limiting device to adjust the X-ray field and angle freely. Adopt manual controller and remote controller to do exposure. Optional: PLXF152 mobile table for high frequency mobile X-ray equipment. PLX101D is equipped with built-in battery, can take 200 films when full charged. Rocker can move up and down, automatically balance High quality X-ray monoblock can rotate in ±90 Options PLXF152 Mobile Bed For Mobile X-ray Machine Size: 2000 X 700X 500mm Range of grid box movement 1210mm Size of grid box: 430X 430(17 X 17) Bucky Stand Height: 1770mm Vertical movement range: 470-1470mm Grid density: 103L/inch Grid radio: 10:1 Focus distance: 150cm Maximum grid box: 17 X 17 Technical Parameters
100 mA, 100 KVP Mobile X-ray Machine 100mA, 100 KVP, Mobile X-ray Machine for Radiography only Electronic Timer Electronic Overload Protection Device Stationary Anode X-ray Tube : BEL or Imported Collimator Counter Balanced Mobile Stand Suitable for Bed Side X-rays
We're a leading XRay machine and accessories manufacturer company with over 29 years of experience and global presence and distributor network in 7 different countries. We have Line Frequency & High Frequency, APR X-Ray Machine, Dental X-Ray Machine, Mobile 100MA X-Ray Machine, 300MA X-Ray Machine, 500MA XRay Machine, Vertical Bucky, Multi-Position Bucky Table, 4 & 2 Way Floating Bucky Table Etc Beside new machines, we offer complete modification & repairing of any brand XRay machines, Rotating Anode Tube Head, HT 100MA, 300MA, 500MA Etc
Power Output 5.0KW x ray machine Main Inverter frequency 40 KHz X-ray Tube of radiography machine fixed anode focus: 1.5 (X-ray tube for high frequency) Power Supply 220V�±10% 50Hz Inner-resistance â?¤1.0�© Operation Method Wire/wireless control mobile x-ray machine safety mobile x ray machine cost mobile x ray machine price
2.5kw high frequency portable X-ray machines PLX101 x ray tube Fixed Anode Power Output of x ray machine 2.5kW Frequency 25kHz Tube voltage 40~100kV Power Supply 220V�±10%, 50kHZ Operation Method Wire/ Wireless control price list of x-ray machine price of 500ma x-ray machine price of medical x ray machine
X-ray machine Technical parameter 1. The numbers of x-ray tubes used in the product are also used as product number and x-ray generator (bulb tube head) number. 2. The current and voltage of x-ray tubes are fixed in three groups, they are: X exposure voltageú¿kvpú¬ 60 65 70 X-ray currentú¿maú¬ 0.50 0.85 1.10 3. When adding up voltage, total current is less than 2a and total power is 500w 4. Drain current and earth resistance are in accordant with the stipulates in gb9706.1 5. The three groups of voltage (60kvíó65kvíó70kv) are adjustable. 6ú«wireless remote control in any angles within 10 meters part form the control box 7. The parameter of x-ray generator (bulb tube head) 7.1. The parameter of x-ray tubes A. Focus index: 0.3í-0.3mm2 Bú«the voltage of the-highest-voltage generator: 90kv C. The highest inverse peak voltage: 90kv D. Filament characteristic: vf=5ví+0.5vú¼if=3a E. Target surface obliquity: 12íp F. The cooling manner of bulb tube head: oil immersion 8.7.2 the parameter of x-ray generator (bulb tube head): A. Focus-skin distance: 200mm B. The thickness of filter-ray film: more than 1.5mmal C. The leakage rate of x-ray: no more than 0.002mgy/h (no. 29.204.3 in gb9706.12 prescript that the leakage rate of x-ray is no more than 0.25mgy/h) D. The manner of limiting beam: using planigraphic device
Technical parameter 1. The numbers of x-ray tubes used in the product are also used as product numbers and x-ray generator (bulb tube head) numbers. 2. The current and voltage of x-ray tubes are fixed in three groups, they are: X exposure voltage (kvp) 60 65 70 X-ray current (ma) 0.50 0.85 1.10 3. When adding up voltage, total current is less than 2a and total power is 500w 4. Drain current and earth resistance are in accordant with the stipulates in gb9706.1 5. The three groups of voltage (60kv, 65kv, 70kv) are adjustable. 6. Wireless remote control in any angles within 10 meters part form the control box 7. The parameter of x-ray generator (bulb tube head) 7.1. The parameter of x-ray tubes A. Focus index: 0.3í-0.3mm2 B. The voltage of the-highest-voltage generator: 90kv C. The highest inverse peak voltage: 90kv D. Filament characteristic: vf=5ví+0.5v, if=3a E. Target surface obliquity: 12íp F. The cooling manner of bulb tube head: oil immersion 7.2 the parameter of x-ray generator (bulb tube head): A. Focus-skin distance: 200mm B. The thickness of filter-ray film: more than 1.5mmal C. The leakage rate of x-ray: no more than 0.002mgy/h (no. 29.204.3 in gb9706.12 prescript that the leakage rate of x-ray is no more than 0.25mgy/h) D. The manner of limiting beam: using planigraphic device
100 mA Mobile x-ray machine. very good image quality. built in stabilizer. works on 220v AC.
Tube stand (xts-01) Type : floor-to-ceiling rail Distance of longitudinal travel : 2550mm Distance of vertical travel : 1600mm Rotation of x-ray tube : ±180° Lock system : electromagnetic lock by manual Weight : 170kg Ceiling (xce-01, option) Type : ceiling rail Distance of longitudinal travel : 2800mm Distance of vertical travel : 1200mm Rotation of x-ray tube : ±180° Lock system : electromagnetic lock by manual Weight : 130kg Bucky stand (xbs-01, option) Type : vertical travel Distance of vertical travel : 120mm ~ 1780mm X-ray grid : grid ratio of 8:1, 103 line/inch Front plate to film distance : 50mm Weight : 105kg 4way type bucky table (xbt4-01) Type : 4way travel Longitudinal distance of tabletop sliding : 420±5mm Lateral distance of tabletop sliding : 120±5mm Tabletop to floor distance : 665mm X-ray grid : grid ratio of 8:1, 103line/inch Dimensions : 2000l x 750w x 665h (mm) Weight : 150kg 6way type bucky table (xbt6-01, option) Type : 6way travel Drive type : electric motor drive X-ray grid : grid ratio of 8:1, 103line/inch Longitudinal distance of tabletop sliding : 420±5mm Lateral distance of tabletop sliding : 120±5mm Vertical distance of tabletop : 300±5mm Tabletop to floor distance : 689(880)mm Dimensions : 2000l x 750w x 680(880)h (mm) Weight : 170kg High voltage cable (hvc-6/8) Length : 6m/8m Maximum voltage : dc 75kv The number of core line : 3 lines
NDT X ray equipment is used for inspect the inner fault of the material. It adopts radiography theory to make the image on the film, in order to evaluate the work piece. Features of X Ray Generator: Adopt high temperature installation technology and high pure degree aluminum radiator to improve 30% heat radiation. Portable design, light weight and easy operation. SF6 gas insulator, grounded-anode design to keep the operator safety. Strictly follow 1:1 work and rest radio, eliminating the disoperation. Good HV coil made by imported enamel wire in the generator to improve the power. Glass tube Panoramic XXH-1005 Power(KW) >1.0 , Beam Angle: 360*25 ,Max.Penetration A3 steel (mm) : 6 XXH-1605 Power(KW) >1.5 , Beam Angle: 360*25 ,Max.Penetration A3 steel (mm) : 18 XXH-2005 Power(KW) >2.0 , Beam Angle: 360*25 , Max.Penetration A3 steel (mm) : 26 XXH-2505 Power(KW) >2.5 , Beam Angle: 360*25 , Max.Penetration A3 steel (mm) : 36 XXH-3005 Power(KW) >3.0 , Beam Angle: 360*25 ,Max.Penetration A3 steel (mm) : 46 XXH-3505 Power(KW) >3.5 , Beam Angle: 360*25 , Max.Penetration A3 steel (mm) : 56 Glass tube Directional XXQ-1005 Power(KW) >1.0 , Beam Angle: 40 , Max.Penetration A3 steel (mm) : 8 XXQ-1605 Power(KW) >1.5 , Beam Angle: 40 , Max.Penetration A3 steel (mm) : 20 XXQ-2005 Power(KW) >2.0 , Beam Angle: 40 , Max.Penetration A3 steel (mm) :29 XXQ-2505 Power(KW) >2.5 , Beam Angle: 40 , Max.Penetration A3 steel (mm) : 39 XXQ-3005 Power(KW) >3.0 , Beam Angle: 40 , Max.Penetration A3 steel (mm) : 49 XXQ-3505 Power(KW) >3.5 , Beam Angle: 40 , Max.Penetration A3 steel (mm) : 59 Ceramic tube directional XXG-1605 Power(KW) >1.5 , Beam Angle: 40 , Max.Penetration A3 steel (mm) : 20 XXG-2005 Power(KW) >2.0 , Beam Angle: 40, Max.Penetration A3 steel (mm) : 29 XXG-2505 Power(KW) >2.5 , Beam Angle: 40 , Max.Penetration A3 steel (mm) : 39 XXG-3005 Power(KW) >3.0 , Beam Angle: 40 , Max.Penetration A3 steel (mm) : 49 XXG-3505 Power(KW) >3.5 , Beam Angle: 40°, Max.Penetration A3 steel (mm) : 59 wooden case 80KG
APR Model with Digital Display and Feather Touch Panel. Suitable for all type of X-Rays Mobile as well as Fixed Horizontal Bucky Table / Floating Table Top Table Exposure Counter Stationary as well as Rotating Anode. Counter Balanced and Spring Balanced Mechanical. One Unit, Approx Weight 300Kg.
Brand New Ge Make Portable 20 Ma X Ray Machine For Sale With Tube Head Anmd Console .(fully Refurbished Equipment)