Supplier From Delhi, New Delhi, India
 
Brands : Schnieder, Abb, Legrand, L&T, C&S, Chint, HPL, Hager, Havells, etc
Current Rating : 6A to 125A
No Of Poles : 2P, 4P
Voltage Rating : 230 - 240 VAC, 230 VAC, 240 - 415 VAC, 400 - 415 VAC , 415 V
Breaking Capacity : 6KA to 10KA
Sensitivity (mA) : 30 mA to 500mA
Buy RCCB online from India at wholesale rates. If you have been looking for Schneider, ABB, L&T, Siemens, Chint, havells, HPL, Hager etc RCCB dealers, your search ends here as you can get the best RCCB distributors in countries such as USA, UK, Australia, Sweden, Africa, Middleeast, Europe, Asia etc. You can purchase RCCB of the finest quality and rest assured to get the best in terms of both durability and performance. If you are bothered about the prices, you can be totally sure to get the best rates as brings you genuine Products.
Sep-06-08
 
Mainly used in the low voltage distribution switchboard to control and protect power distribution systerm. Its technical index reaches the international advanced standard of that kind of products in 1990s and conforms to criteria for low voltage breaker in iec60947-2
Jun-28-13
 
Product Description
Residual current circuit breaker RCCB
Rated current: 25A, 32A, 40A,50A,63A,80A,100A
Rated sensitivity: 10mA, 30mA, 100mA,300mA
Product Feature
Feature (EBS6R Residual current circuit breaker )
1. Electro-magnetic release, voltage independent
2. High ability of withstanding short circuit current
Connection ( EBS6R RCCB )
Type of terminal: Lug type and pin type
Cables up to 35mm2
Product Specification/Models
Model: EBS6R RCCB ( Residual current circuit breaker )
Standard: IEC61008-1
Rated current In (A): 20A, 25A, 32A, 40A, 50A, 63A, 80A, 100A
Rated voltage Ue (V): 2 poles: 230VAC
4 poles: 230/400VAC
Poles: 2P, 4P

Standard export carton
Aug-28-06
Supplier From Wenzhou, Zhejiang, China
May-11-11
 
An Earth Leakage circuit breaker (ELCB) (now referred to as residual current circuit breaker-RCCB) is a safety device used in electrical installation with high earth impedance to prevent shock. High Quality circuit breaker (ELCB’S) Manufacturer and Exporters provides Automatic models as well as manual models ELCB’s.
5108 Residual Current Circuit Breaker Rccb Suppliers
Short on time? Let Residual Current Circuit Breaker Rccb sellers contact you.
May-23-19
 
Standard: IEC/EN60898-1 GB/T10963.1
Instantaneous trip type: Electronic /Electromagnetic
The number of poles: 1P+N/3P+N
Rated limit short circuit breaking capacity (Inc): 6kA
Rated working current (In): 16-63A (can be extended to 125A)
Rated working voltage (Ue): AC 230/400V
Rated operating frequency: 50/60Hz
Rated impulse withstand voltage (Uimp): 4kV
Rated residual operating current : 10/30/100/300mA
Mechanical/electrical life: 4000/4000 Times
Type of residual current : A/AC
May-23-19
 
Standard: IEC/EN61008-1 GB/T16916.1
Release Type of Leakage Protection: Electronic /Electromagnetic
The number of poles: 1P+N/3P+N
Rated limit short circuit breaking capacity (Inc): 6kA
Rated working current (In): 16-63A
Rated working voltage (Ue): AC 230/400V
Rated operating frequency: 50/60Hz
Rated impulse withstand voltage (Uimp): 4kV
Rated residual operating current : 10/30/100/300mA
Mechanical/electrical life: 4000/4000 Times
Type of residual current: A/AC
May-23-19
 
Standard: IEC/EN61008-1 GB/T16916.1
Release Type of Leakage Protection: Electronic /Electromagnetic
The number of poles: 1P+N/3P+N
Rated limit short circuit breaking capacity (Inc): 6kA
Rated working current (In): 16-63A
Rated working voltage (Ue): AC 230/400V
Rated operating frequency: 50/60Hz
Rated impulse withstand voltage (Uimp): 4kV
Rated residual operating current : 10/30/100/300mA
Mechanical/electrical life: 4000/4000 Times
Type of residual current: A/AC
May-23-19
 
Standard: IEC/EN61008-1 GB/T16916.1
Release Type of Leakage Protection: Electronic /Electromagnetic
The number of poles: 1P+N/3P+N
Rated limit short circuit breaking capacity (Inc): 6kA
Rated working current In: 16-63A (can be extended to 125A)
Rated working voltage (Ue): AC 230/400V
Rated operating frequency: 50/60Hz
Rated impulse withstand voltage (Uimp): 4kV
Rated residual operating current : 10/30/100/300mA
Mechanical/electrical life: 4000/4000 Times
Type of residual current: A/AC
May-23-19
 
Standard: IEC/EN61008-1 GB/T16916.1
Release Type of Leakage Protection: Electronic /Electromagnetic
The number of poles: 1P+N/3P+N
Rated limit short circuit breaking capacity (Inc): 6kA
Rated working current (In): 16-63A
Rated working voltage (Ue): AC 230/400V
Rated operating frequency: 50/60Hz
Rated impulse withstand voltage (Uimp): 4kV
Rated residual operating current : 10/30/100/300mA
Mechanical/electrical life: 4000/4000 Times
Type of residual current: A/AC
Sep-06-08
Supplier From Shanghai, Shagnhai, China
Dec-02-16
Supplier From Wenzhou, Zhejiang Sheng, China
 
We manufacture and export Residual Circuit Breaker Nylon Body to our customers from Wenzhou, Zhejiang, China. NFIN series Residual current circuit breaker (without over-current protection) is suitable for the line of AC 50/60Hz,voltage 240V(2pole)/415V(4pole),rated current up to 63A.When there is human electricity shock or if the leakage current of the line exceeds the prescribed value, RCCB will cut off the power rapidly to protect human safety and prevent the accident due to the current leakage.
It can be used as infrequent changeover of the line in normal situation. RCCB is applicable to industrial area, commercial area, tall building and civil house.
It complies with standard IEC/EN61008.1 and GB16916.1
Jan-30-11
Supplier From Lauf-A-D-Pegnitz, Germany
 
It can happen very quickly: Thoughtlessly touching a currentcarrying cable; a faulty connecting cable; or a device fault. Happy are those who have protected their electrical system with the right RCCB. In the event of damage, it is activated within a fraction of a second, breaks the circuit and thus possibly saves lives. In this way, everyday exposure to current gets considerably safer.

For new installations and extensive renovations of commercial and private electrical systems, the use of RCCBs is mandatory according to VDE 0100-410 since June 2007 anyway. This also refers to all outdoor electrical systems and electric circuits.

Our product range offers you the right RCCB solution for every field of application because - in addition to devices of type A (sensitive to pulsating currents) and type B (sensitive to universal current) for the German market - we can also deliver devices of type AC (sensitive to alternating current - not approved for Germany) for export.
Dec-02-16
Supplier From Wenzhou, Zhejiang Sheng, China
 
Main Specification
Trademark:CNHUNG/OEM
Poles:2P/4P
Rated current(A): 25,40, 63
Rated Voltage(V):AC230 / 400V
Frequency:50 / 60Hz
Rated residual action current(mA):30, 100, 300

-
Mar-01-24

Rccb

$5 - $20
MOQ: Not Specified
Supplier From New Delhi, Delhi, India
 
Residual Current Circuit Breaker or RCCB is basically a gadget that senses current and disengages any low voltage (uneven current) circuit whenever a fault occurs. The main purpose of installing a Residual Current Circuit Breaker fundamentally is to protect people from electric shocks or death caused by them.
Jul-10-19
Supplier From Huzhou, Zhejiang, China
Jun-21-24
 
Specifications ID Residual Current Circuit Breaker
Rating up to 100 A
Breaking capacity up to 6 k A
Model No: ID
Rated Current: 16, 25, 40, 63, 80, 100 A
Sensitivity : 10, 30, 100, 300, 500 m A
Rated Voltage: 230 VAC(2 P), 400 VAC(4 P)
No. Of Pole: 2 P, 4 P
Type: Type AC and Type A
Breaking Capacity: 6000 A
GOLD Member
Sep-03-10
Supplier From Mumbai, Maharashtra, India
Dec-26-19
Supplier From Godhra, Gujarat, India
 
Air circuit breaker -ACB
Vacuum Circuit Breakers- VCB
Vacuum Bottles
Protective Numerical Relays
Electrical meters
Timers
Electrical Leakage Circuit Breaker -ELCB
Residual Current Circuit Breaker -RCCB
Miniature Circuit Breaker -MCB
Molded Case Circuit Breaker -MCCB
Power Extension Boards
Ceiling fans
Switches
Plug / sockets
Domestic & industrial lighting accessories
Speed regulator for fans

Note: We are able to supply any kind of electrical accessory based on client specifications.
Jul-28-18
Supplier From Yueqing, Zhejiang, China
 
L7 2P 20A current circuit breaker is mainly used in AC50/60Hz single pole230V or two,three,four pole 400V voltage for overload and short-circuit protection as well as for infrequent on-and-off switching electric equipment and lighting circuit under normal conditional.

The product is suitable for industry,business,building,residence,etc.

It's conformity with GB10963,IEC60898 standards.
5108 Residual Current Circuit Breaker Rccb Suppliers
Short on time? Let Residual Current Circuit Breaker Rccb sellers contact you.