L7 2P 20A current circuit breaker is mainly used in AC50/60Hz single pole230V or two,three,four pole 400V voltage for overload and short-circuit protection as well as for infrequent on-and-off switching electric equipment and lighting circuit under normal conditional.
The product is suitable for industry,business,building,residence,etc.
It's conformity with GB10963,IEC60898 standards.
We manufacture and export Residual Circuit Breaker Nylon Body to our customers from Wenzhou, Zhejiang, China. NFIN series Residual current circuit breaker (without over-current protection) is suitable for the line of AC 50/60Hz,voltage 240V(2pole)/415V(4pole),rated current up to 63A.When there is human electricity shock or if the leakage current of the line exceeds the prescribed value, RCCB will cut off the power rapidly to protect human safety and prevent the accident due to the current leakage. It can be used as infrequent changeover of the line in normal situation. RCCB is applicable to industrial area, commercial area, tall building and civil house. It complies with standard IEC/EN61008.1 and GB16916.1
Mini circuit breaker has novel structure , reliable performance, high breaking capacity, pleasing outlook and small size. Its case and items are adopted by high fireresistant and shockproof plastics, it mainly used in the building office, house and similar building for illuminating at ac 50hz(60 hz), rated voltage below 400v , rated current below 100 a, distribution circuit and equipment overload, short circuit protection .It can also be used for unfrequent switch over of the circuit under normal conditions .This product conforms to the requirement of iec 60898&gb 10963 standards.
L7 Miniature Circuit Breaker Application L7 series circuit breaker is used in lighting distribution system or motor distribution system for protection overload and short-circuits in the system. The product is neoteric in structure, reliable and excellent in performance. It has high breaking capacity, can trip quickly, and its case and items are adopted by high fire-resistant and shockproof plastic. The product, with long life, is mainly used in AC 50HZ/60HZ single-pole 230V or two, three, four poles 400V circuit for overload and short-circuit protection as well as for infrequent on-and-off switching electric equipment and lighting circuit in normal case. The products comply with IEC 60898.
It can happen very quickly: Thoughtlessly touching a currentcarrying cable; a faulty connecting cable; or a device fault. Happy are those who have protected their electrical system with the right RCCB. In the event of damage, it is activated within a fraction of a second, breaks the circuit and thus possibly saves lives. In this way, everyday exposure to current gets considerably safer. For new installations and extensive renovations of commercial and private electrical systems, the use of RCCBs is mandatory according to VDE 0100-410 since June 2007 anyway. This also refers to all outdoor electrical systems and electric circuits. Our product range offers you the right RCCB solution for every field of application because - in addition to devices of type A (sensitive to pulsating currents) and type B (sensitive to universal current) for the German market - we can also deliver devices of type AC (sensitive to alternating current - not approved for Germany) for export.
2P 500V DC solar mini circuit breaker Description: PQB1Z-63 2P PV DC breaker supplementary protectors are designed to provide overcurrent protection within appliances or electrical equipment, where a branch circuit protaction is already providedd or not required. Devices are designed for direct current(DC) control circuit applications. Technical Parameter: Item DC MCB Code PQB1Z-63 Pole 1P 2P 3P 4P Voltage 250VDC 550VDC 800VDC 1000VDC Current 1A,3A,6A,10A,16A,20A,32A,40,50A,63A Standard IEC/EN60947 Breaking Capacity 6KA,10KA Characteristic Curve B,C,D Working Temperature "-5°"to +40° Protection Degree IP20 Electrical life More than 8000times Mechanical life More than 2000times Dimension(W)X(H)X(D) 18X80X71 36X80X71 54X80X71 72X80X71 Installation 35MM DIN RAIL Accessory YES Installation Altitude â?¤2000M
Main Specification Trademark:CNHUNG/OEM Poles:2P/4P Rated current(A): 25,40, 63 Rated Voltage(V):AC230 / 400V Frequency:50 / 60Hz Rated residual action current(mA):30, 100, 300 -
2-wire & 4-wire circuit breakers Description It is an electronic type circuit breaker. The PG circuit breaker range, from 5 to 60 A, 2P (1 Ph + N) or 4P (3 Ph + N), with or without earth leakage protection (300 mA - 500 mA or 650 mA), offers the right product to suit each type of installation. It complies with NFC 61-450; IEC60947-2 French standard. DISJONCTEURS DIFFERENTIELS BIPOLAIRES 5/15A 1 Tension de fonctionnement 220V 2 Calibrage (REGLABLE) 5A, 10A, ou 15A 3 Fr�©quence 50Hz 4 Nombre de p�´les 2 5 Nombre de p�´les prot�©g�©s 1 6 500mA 7 Chute de tension
Brands : Schnieder, Abb, Legrand, L&T, C&S, Chint, HPL, Hager, Havells, etc Current Rating : 6A to 125A No Of Poles : 2P, 4P Voltage Rating : 230 - 240 VAC, 230 VAC, 240 - 415 VAC, 400 - 415 VAC , 415 V Breaking Capacity : 6KA to 10KA Sensitivity (mA) : 30 mA to 500mA Buy RCCB online from India at wholesale rates. If you have been looking for Schneider, ABB, L&T, Siemens, Chint, havells, HPL, Hager etc RCCB dealers, your search ends here as you can get the best RCCB distributors in countries such as USA, UK, Australia, Sweden, Africa, Middleeast, Europe, Asia etc. You can purchase RCCB of the finest quality and rest assured to get the best in terms of both durability and performance. If you are bothered about the prices, you can be totally sure to get the best rates as brings you genuine Products.