Oxygen O2 Industrial Gases CAS No.: 7782-44-7 EINECS No.: 231-956-9 UN No.: UN1072 Purity: 99.995%-99.9997% Dot Class: 2.2 Appearance: Colorless Grade Standard: Industrial Grade, Medical Grade, Electronic Grade. Industry Use: Steel making, non-ferrous metal smelting.Cutting metal material. Medical Use: In first-aid treatment of emergencies such as suffocation and heart attack, in the treatment of patients with respiratory disorders and in anaesthesia. Semiconductor Fabrication: Chemical vapour deposition of silicon dioxide, thermal oxide growth, plasma etching, plasma stripping of photoresist and carrier gas in certain deposition/diffusion operations.
Oxygen O2 CAS No.: 7782-44-7 EINECS No.: 231-956-9 UN No.: UN1072 Purity: 99.995%-99.9997% Dot Class: 2.2 Appearance: Colorless Grade Standard: Industrial Grade, Medical Grade, Electronic Grade. Industry Use: Steel making, non-ferrous metal smelting.Cutting metal material. Medical Use: In first-aid treatment of emergencies suc h as suffocation and heart attack, in the treatment of patients with respiratory disorders and in anaesthesia. Semiconductor Fabrication: Chemical vapour deposition of silicon dioxide, thermal oxide growth, plasma etching, plasma stripping of photoresist and carrier gas in certain deposition/diffusion operations. - -
OXYTEK 5 LT CAPACITY OXYGEN (O2) CONCENTRATOR STARTING FROM 335 USD, LOWERS DEPENDING ON QUANTITY ORDERED. TECHNICAL SPECIFICATIONS: K5BW Device's Electric Senif Class II, Type BF Weight 16KG Dimensions 305 x 300 x 535 (Length Width Height) mm Working Type Continuous Flow adjustment button 0-5 LPM Oxygen concentration 931% 3% (0-5LPM) Oxygen concentration sensor's alarm 82% or less Maximum output power (to sdg Average sound level 45dB (A) Power supply 230VAC-50HZ Operating Temperature / Humidity Range and Oxygen Concentration below flow rate CONCENTRATION 96% -06%
Thank you for purchasing and using our company's ultrasonic oxygen concentration / flow sensor. 1, please carefully read the instructions and fully understand the contents of the sensor after operation and maintenance. Improper use may cause damage to the sensor. (no violent impact and falling ground) 2, without the consent of the company, it is strictly prohibited to alter the structure and components of the sensor without authorization. The company is not responsible for any personal safety incidents or sensor abnormalities caused by unauthorized alterations. 3, the specifications and instruction contents of this sensor may be changed due to the technical improvement of the product. 4, this instruction manual must be handed to the actual user of the sensor and stored in it, and placed at any time where the actual user of the sensor can access it. 5, the company has the right to interpret the instructions for the sensor. 2ã??technical parameter Measurement parameters measuring method range Resolution accuracy O2 Ultrasonic 20.5%-95.6% 0.1% �±1.8%FS 5-45â?? Note: the range can be customized according to customer requirements. Sample gas requirements Water removal (no condensation); dust filtration (
O2-A3 Oxygen Sensor O2 Sensor Description Alphasense Oxygen sensors use capillary flow control. Unlike partial pressure oxygen sensors, they have good pressure and temperature dependence, making them the best choice in safety applications. Standard galavanic sensors use lead for greatest reliability but fixed lifetime. O2-A3 Oxygen Sensorsize: 20mm diameter, the industry standard size for portable gas detectors O2-A3 Oxygen Sensor O2 Sensor Specifications * Output: 60 to 85 μA @ 22â??, 20.9% O2 * Response time t90 : < 15 (s) from 20.9% to 0% O2 * Operating life: > 36 months * Temperature range : -30 to 55'C * Pressure range : 80 to 120 kPa * Humidity range : 5 to 95 % rh continuous * Height : 17.4 mm (including foam ring) * Weight: < 16 g
O2-C2 Oxygen Sensor (O2 Sensor) Description Alphasense Oxygen sensors use capillary flow control. Unlike partial pressure oxygen sensors, they have good pressure and temperature dependence, making them the best choice in safety applications. Standard galavanic sensors use lead for greatest reliability but fixed lifetime. O2-C2 Oxygen Sensor size: 20mm diameter, extra height allows additional filter material when measuring combustion gases O2-C2 Oxygen Sensor (O2 Sensor) Specifications: * Output: 80 to 120A @ 20.9% O2 * Response time t90: < 50(s) from 20.9% to 0% O2 * Linearity: -0.6 % O2 deviation @ 10% O2 * Operating life: > 24 months * Temperature range : -30 to 55'C * Pressure range: 80 to 120 kPa * Humidity range: 5 to 95 % rh continuous * Weight: < 18 g
O2-A3 Oxygen Sensor O2 Sensor Description Alphasense Oxygen sensors use capillary flow control. Unlike partial pressure oxygen sensors, they have good pressure and temperature dependence, making them the best choice in safety applications. Standard galavanic sensors use lead for greatest reliability but fixed lifetime. O2-A3 Oxygen Sensorsize: 20mm diameter, the industry standard size for portable gas detectors O2-A3 Oxygen Sensor O2 Sensor Specifications * Output: 60 to 85 μA @ 22'C, 20.9% O2 * Response time t90 : < 15 (s) from 20.9% to 0% O2 * Operating life: > 36 months * Temperature range : -30 to 55 'C * Pressure range : 80 to 120 kPa * Humidity range : 5 to 95 % rh continuous * Height : 17.4 mm (including foam ring) * Weight: < 16 g
O2-a2 oxygen sensor Performance Output î¼a @ 20.9% o2 80 to 120 Response time t90 (s) from 20.9% to 0% o2 < 15 Zero current î¼a in n2 < 2.5 Linearity % o2 deviation @ 10% o2 0.6 Lifetime Output drift % change in output @ 3 months < 1 Operating life months until 85% original output of 20.9% o2 > 24 Environmental Humidity sensitivity % o2 change: 0% to 95% rh @ 40â?? < 0.7 Co sensitivity % (change o2 reading) / % co2 @ 5% co2 0.1 Pressure sensitivity (% change of output)/(% change of pressure) @ 20kpa < 0.1 Key specifications Temperature range â?? -30 to 55 Pressure range kpa 80 to 120 Humidity range % rh non-condensing (0 to 99% rh short term) 5 to 95 Storage period months @ 3 to 20â?? (store in sealed pot, open circuit) 6 Load resistor î© (recommended) 47 to 100 Diameter mm (including label) 20.0 Height mm (including foam ring) 17.4 Weight g < 16 -
O2-M2 Oxygen Sensor Description Alphasense Oxygen sensors use capillary flow control. Unlike partial pressure oxygen sensors, they have good pressure and temperature dependence, making them the best choice in safety applications. Standard galavanic sensors use lead for greatest reliability but fixed lifetime. Specifications * Output: 80 to 120 uA @ 20.9% O2 * Response time t90: < 15 (s) from 20.9% to 0% O2 * Linearity: 0.6 % O2 deviation @ 10% O2 * Operating life: > 24 months *Temperature range: -30 to 55 'C * Pressure range: 80 to 120 kPa * Humidity range: 5 to 95 % rh continuous * Diameter: 20.0 mm (including label) * Heigh: 17.4 mm (including foam ring) * Weight: < 16g
PO2-2x Percent Oxygen Sensor (O2 sensor) General Purpose % O2 measurement when CO2 > 0.1%. Use when acid gases are present (CO2, HCl, HCN, etc.) PO2-2x Percent Oxygen Sensor (O2 sensor) Direct Replacement Guide Analytical Industries: XLT-11-15 Teledyne: A-3, A-5 PO2-2x Percent Oxygen Sensor (O2 sensor) Specifications: Sensor Technology: Micro Fuel Cell Signal Output: 105 - 260uA Measuring Range: 0 - 100 Percent Response Time T90: 7 Seconds Accuracy Full Scale: ± 1% of Signal Repeatability F.S.: ±0.5% Temp Coefficient: 2.54 %/ºC Operating Temp: 0 to 50ºC Storage Temp: 0 to 45ºC Recommended Flow: 0.5 - 2 SCFH Humidity: 0 - 100% RH (Non - Condensing) Expected Life: 12 - 15 Months Storage: 6 Months Warranty: 9 Months PCB Connection: Center Foil Negative Outer Foil Positive
Features * oxygen pressure range 2 mbar - 3bar * zirconium dioxide (zro2 ) sensing elements * non-consumption technology * integral heating element * no need for temperature stabilisation * no reference gas required * high accuracy * linear output signal * operates with external interface boards * 80mm, 220mm and 400mm probes available Specifications Heater supply* Porous lid cap 4v dc +/- 0.1v dc (1.7a) Stand by 1.65v dc (0.7a) Full porous cap 4.35v dc +/- 0.1v dc (1.85a) Stand by 2v dc (0.85a)
Features * oxygen pressure range 2 mbar - 3bar * zirconium dioxide (zro2 ) sensing elements * non-consumption technology * integral heating element * no need for temperature stabilisation * no reference gas required * high accuracy * linear output signal * operates with external interface boards * pcb mountable Specifications Heater supply* Porous lid cap 4vdc +/- 0.1vdc (1.7a) Stand by 1.65vdc (0.7a) Full porous cap 4.35v dc +/- 0.1v dc (1.85a) Stand by 2v dc (0.85a)
Thank you for purchasing and using our company's ultrasonic oxygen concentration / flow sensor. 1, please carefully read the instructions and fully understand the contents of the sensor after operation and maintenance. Improper use may cause damage to the sensor. (no violent impact and falling ground) 2, without the consent of the company, it is strictly prohibited to alter the structure and components of the sensor without authorization. The company is not responsible for any personal safety incidents or sensor abnormalities caused by unauthorized alterations. 3, the specifications and instruction contents of this sensor may be changed due to the technical improvement of the product. 4, this instruction manual must be handed to the actual user of the sensor and stored in it, and placed at any time where the actual user of the sensor can access it. 5, the company has the right to interpret the instructions for the sensor. 2ã??technical parameter Measurement parameters measuring method range Resolution accuracy FLOW Ultrasonic 0-10L/min 0.1L �±0.2L/min O2 Ultrasonic 20.5%-95.6% 0.1% �±1.8%FS 5-45â?? Note: the range can be customized according to customer requirements. Sample gas requirements Water removal (no condensation); dust filtration (
4OXV CiTiceL Oxygen Gas Sensor (O2 Sensor) Key Features and Benefits: * False alarm immunity * Enhanced response time in extreme applications * Reliably meets stated life * Superior environmental performance
Features * oxygen pressure range 2 mbar - 3bar * zirconium dioxide (zro2 ) sensing elements * non-consumption technology * integral heating element * no need for temperature stabilisation * no reference gas required * high accuracy * linear output signal * operates with external interface boards Specifications Heater voltage: Porous cap (15mm): 4.35v dc +/- 0.1v dc (1.85a) Stand by: 2v dc (0.85a) Pump resistance @ 700'C: < 6kOhm Permissible gas temperature: -100 to 250C Gas flow rate: 0 to 10 m/s Repetitive permissible acceleration: 5 g Incidental permissible acceleration: 30 g
optical oxygen sensor O2 Gas sensor LOX-02 Description The LuminOx Family is a range of factory calibrated optical sensors which measure ambient O2levels using the principle of fluorescence quenching by oxygen. Our unique patented process allows us to produce an oxygen sensor that benefits from low power, traditionally associated with electrochemical sensing devices, while providing a much longer lifetime due to the non-depleting sensing principle. Applications Typical applications for the Cheap Price Oxygen Sensor LOX-02 are; Oxygen detection Portable equipment Breathing apparatus Inerting Medical Lab equipment Agriculture Incubation Fore prevention Flue gas in condensing boilers
FEATURES * Oxygen pressure range 2 mbar - 3bar * Zirconium dioxide (ZrO2 ) sensing elements * Non-consumption technology * Integral heating element * No need for temperature stabilisation * No reference gas required * High accuracy * Linear output signal * Operates with external interface boards SPECIFICATIONS Heater Voltage Porous Cap (15mm) 4.35V DC ± 0.1V DC (1.85A) Stand by 2V DC (0.85A) Pump resistance @ 700'C < 6k� Permissible gas temperature -100 to 250'C Gas flow rate 0 to 10 m/s Repetitive permissible acceleration 5 g Incidental permissible acceleration 30 g z
1.General description The luminox family (lox) is a range of factory calibrated oxygen sensors which measure ambient oxygen partial pressure (ppo2) levels using the principle of fluorescence quenching by oxygen. By default luminox measures ppo2 (mbar) and temperature (°c). An optional pressure sensor enables luminox to also measure barometric pressure (mbar) and to convert the ppo2 reading to an oxygen concentration (o2%). The sensor benefits from low power operation, traditionally associated with electrochemical sensors, while providing a much longer lifetime due to the non-depleting sensing principle. Luminox is ppo2 and temperature compensated, enabling accurate operation over a wide environmental range without the need for additional system components. Unlike other sensor technologies, luminox is very stable and robust, does not contain lead or any other Hazardous materials and has negligible cross sensitivity to other gases. 2.Cleaning The housing of the sensor can be cleaned using a damp cloth. The sensor should not be immersed in any cleaning media. Full application and technical support can be provided by our knowledgable and highly experienced engineering team if required. 3.Benefits -low power -can also measure o2% & barometric pressure (lox-02) -suitable for battery power use -long life - high accuracy - small & compact - low cost -maintenance free contains no hazardous materials -connects directly to microcontroller - without any additional circuitry. - factory calibrated 4.Applications -oxygen detection -portable equipment - breathing apparatus - inerting - medical -lab equipment - agriculture -incubation -fire prevention - flue gas in condensing boilers