Vasthi model vt-90-o2, oxygen gas transmitter deficiency sensors are non-intrusive â??smart oxy meterâ?� sensors designed to detect and monitor o2 in air over the range of 0-25%.
Vasthi model vt-90-o2, oxygen gas transmitter deficiency sensors are non-intrusive â??smart oxy meterâ?� sensors designed to detect and monitor o2 in air over the range of 0-25%.
Pressure: High Place of Origin: China Model Number: BW410 Material: Steel, Mn,CrMo,CrMo4,ST52 Brand Name: OEM Use: High Pressure Gas Outside Diameter: 83-356 mm Working pressure: 150-300 bar Test pressure: 225-451 bar Bottom type: Concave,Convex Design wall thickness: 2.1-9.7 mm Nominal water capacity: 0.8-140 L Cylinder height: 230-1770 mm Nominal weight: 1.4-183 kg Our daliy output: 4ton
2L, 2.7L 5L, 8L alloy steel, aluminum gas cylinder for medical and industrial
:- Shivam Industrial Gases - Professional & experienced supplier, trader, manufacturer of Oxygen Gas, Portable Oxygen Cylinders in Delhi-NCR based in Faridabad, Haryana, India. Enquire now for your industrial or commercial application Online.
oxygen gas cylinder for industrial use
Application GTR-7001 is based on the differential pressure method, and is professionally applicable to the determination of gas transmission rate as well as solubility coefficient, diffusion coefficient and permeability coefficient of plastic films, laminated films, high barrier materials, sheeting, metal foils, rubber, tires and permeable membranes. Features Vacuum differential pressure method Patent technology 3 specimens test simultaneously and independently Computer control One-button test, test automatically through whole process High accuracy vacuum sensors embedded in 3 Chambers with independent temperature sensor Test under various RH conditions with Humidity generator (optional) Environment temperature and humidity sensor inside Permeability coefficient ,solubility coefficient and diffusion coefficient test Chambers with water bath temperature control technology Unit based on embedded system,24bit AD Multiple test modes optional Data curves display Traceable reference film calibration Supports DSM system (DSM, lab data management system) Technical Indexes Test range: 0.01 - 190,000 cm3/m2�24h�0.1MPa (Standard) Resolution: 0.001cm3/m2�24h�0.1MPa Samples: 3, independent Vacuum accuracy: 0.1Pa Temperature range: 5C - 95C Temperature accuracy: ±0.1C Humidity range: 0%RH,35%RH-90%RH,100%RH (optional) Humidity accuracy: ±1%RH (optional) Sample thickness: less 5mm Sample size: >= 150mm * 94mm Test area: 48cm2 Test gas: O2, N2, CO2, He, etc Differential pressure: -0.1MPa - 0.1MPa Gas interface: Ф8mm Dimension: 730mm * 510mm * 350mm Power supply: AC 220V 50Hz Net wt. : 63kg Standards ASTM D1434, ISO 15105-1,ISO 2556,GB/T 1038-2000,JIS 7126-1,YBB 00082003 Configuration Delivery: Main unit, computer, G-TRANS software, Temperature controller, vacuum pump(BOC Edwards), tank regulator, PCIE card, communication cable, sample cutter, vacuum grease. Optional: Humidity generator, Reference film, vacuum grease, sample cutter, DSM system.
Capacity : 6 m3 ( 40 litres), 7 m3 ( 47 litres) Working pressure : 150 bar Test pressure: 250 bar Seamless steel tube cylinders.
GAZTRON engineering private limited is one leading manufacturers of PSA based medical oxygen gas generation plant & Oxygen Gas Plants in India. Our Plants are Operation friendly and Maintenance free with Low capital cost and Operation cost is less. For More Information Kindly Call us or
GAZTRON engineering private limited is one leading manufacturers and exporters of PSA based medical oxygen gas generation plant & Oxygen Gas Plants in India. Our PSA based medical oxygen gas generation plant are available with 96% Purity . Our Plants are Operation friendly and Maintenance free with Low capital cost and Operation cost is less. For More Information
Hydrogen Generators Ammonia Cracker Hydrogen Recovery system Water Electrolytic Hydrogen Generator Nitrogen Generators Membrane Nitrogen Generator PSA Nitrogen Generator Nitrogen Technical Input Oxygen Generators PSA Oxygen Generator VPSA Oxygen Generator
Description BX616 portable four-gas detector can make continuous detection to combustible and toxic gases to protect the disasters caused by the O2 deficiency, toxic gas poisoning and combustible gas. Once the gas concentration is abnormal, it sends out an alarm. It is suitable for steel plant, petrochemical plant, petroleum industry, shipbuilding yard, sewage treatment plant, mine, power supply engineering, confined space, etc. Key Features 100, 000 detected records including peak value Calibration point adjustable Two alarm level for each sensor channel STEL& TWA alarm for toxic gases Visual/audible/vibrating alarm Self protection against high concentration combustible gas Low battery alert Confidence beep Data uploading Password management Self-test when power on Self-diagnostic and self correction function
Newly type of hydrogen oxygen gas generator has been used the most advanced technology(Its electrolytic voltage is DC 24V, and electrolytic current is DC 13A,which reduces power supply breakdown. special features of hydrogen oxygen gas generator 1.energy-saving: consume water and electricity; electrolysis water into hydrogen and oxygen gases; use hydrogen and oxygen as source of flame replacing LPG, propane,acetylene fuel,natural gas or other fuel. 2.environmental-friendly and safe: output of hydrogen oxygen flame burning is only water vapor with on smell or no pollution. 3.five safety elements: automatic air switch, non-return valve, auto-pressure release valve,flashback arrestor, flame torch with anti-flashback device. 4.gas production can be adjustable. ( through rotating the black knob in front outer shell.) 5.water-lacking alarm for feeding cell to inform operator to add water into the machine once waterline is lower than 30% of the sight tube. 6.external flashback arrestor can be disassemble,cleanable and reusable. 7.LCD screen shows total gas output per hour,and electrolytic current of each electrolytic cell circularly. 8.detachable electrolytic cells; broken electrolytic cell can be replaceable easily. applications of hydrogen oxygen gas generator 1.precise welding In electronic industry, for welding enameled wires ( copper wires), flame welding circuit board, thermocouple and platinum resistor leading wires. In medical industry,for denture welding, welding metal fitting and mending sand holes in dentistry, no carbon flame disinfection and glass seal In laboratory, for welding of laboratory teaching,providing convenient,safe and clean hydrogen oxygen flame. 2.jewelry industry Gold,silver,platinum,copper jewelries,accessories,ornaments,decorations melting,welding,and so on. 3. heating and sealing glass or quartz glass tubes sealing ; ampule bottles sealing 4. acrylic/organic/perspex/plastic industry ideal tool for polishing irregular surfaces,curved and tilted surfaces,edges,holes and inner corner surfaces of acrylic/organic/perspex/plastic sheets,signs,trophies and other art wares, and make these rough edges and hard to reach places much more clear and transparent. 5.other welding instrument welding,small copper pipes welding,fishhook welding,storage battery tinplate welding 6.carbon cleaning and saving oil for cars and boats ... ... tech data of hydrogen oxygen gas generator-605T power input: AC 220V�10% or AC 110V�10% frequency: 50HZ/60HZ gas output: =600 L/H electrolytic cell volume: 10.8 L feeding cell volume: 3.6L max. water adding: 12.6 L no.of electrolytic cell: 6 no.of feeding cell: 1 gross size: 107 cm � 33 cm56 cm gross weight: 47 kg
4OXV CiTiceL Oxygen Gas Sensor (O2 Sensor) Key Features and Benefits: * False alarm immunity * Enhanced response time in extreme applications * Reliably meets stated life * Superior environmental performance
O2-M2 Oxygen Sensor Description Alphasense Oxygen sensors use capillary flow control. Unlike partial pressure oxygen sensors, they have good pressure and temperature dependence, making them the best choice in safety applications. Standard galavanic sensors use lead for greatest reliability but fixed lifetime. Specifications * Output: 80 to 120 uA @ 20.9% O2 * Response time t90: < 15 (s) from 20.9% to 0% O2 * Linearity: 0.6 % O2 deviation @ 10% O2 * Operating life: > 24 months *Temperature range: -30 to 55 'C * Pressure range: 80 to 120 kPa * Humidity range: 5 to 95 % rh continuous * Diameter: 20.0 mm (including label) * Heigh: 17.4 mm (including foam ring) * Weight: < 16g
1. Current overload or line surge shutdown 2. High temperature compressor shutdown. 3. High pressure alarm shutdown. 4. Low pressure alarm shutdown. 5. Low oxygen cocentrator alarm. Oxygen concentrator: 0.5-5L/min Purity: 95%+_3% Working system Continuous Power Supply AC230V.50Hz/AC220V.60HZ AC120V.60Hz Power: 390VA Net Weight: 16kg( Gross weight: 18.5kgs) Warranty: Long-life compressor designed for 1000 hours of maintenance-free use. Size: 33*26*54cm
welding oxygen acetylene gas cylinder for industrial use
Gas Headspace Analyzer adopts a new handheld design and is equipped with advanced sensors, which can accurately and conveniently determine O2, CO2, N2 in sealed packaging bags, bottles, cans and other packaging containers. It can store the testing data in the device and transfer to the DK-190 software or third-party software. Effectively testing the atmosphere of the package is necessary steps of mass brand manufacturing. Features Testing data can be saved automatically. Portable design is suitable for test on production lines. The testing data can be transported to the DK-190 software or the third-party software. The protective cover of the sampler needle assured the testing safety. The built-in storage of data can reach 1500 pieces , which can meet the needs of large amount. Color display with touching function. It can be used for measurement of oxygen or combination of oxygen and carbon dioxide. The minimum volume of sampling gas is 3 ml. Data can be transmitted through Ethernet and USB. Optional wireless micro-printer. Principle The gas is transported to the embedded sensor which calculate the proportion of O2 and CO2 via the exported signal, the test is stopped when the required condition is reached. Standards This test instrument conforms to many national and international standards: ISO 15105-1, ISO 2556, ASTM D1434, JIS K7126-1, GB/T 1038-2000, YBB 00082003. Applications Packaging Bags Test the volume of O2 and CO2 (optional) in headspace of non-vacuum sealed packaging bags of coffee, cheese, milk tea, milk powder, bread, bean powder, instant food and drugs, etc. Packaging Containers Test the volume of O2 and CO2 (optional) in headspace of packaging containers of coffee, milk powder, food, cheese, can, Tetra Pak and beverage, etc. Technical Specifications Testable Gas O2 (Standard) CO2 (Optional) Test Principle Electrochemistry Infra-red absorption Life of Sensor 2 years (In air) >15 years Specification of Sensor 0-100% Resolution 0.01 % Accuracy ±0.2% ± (0.03% reading value *5%) Sampling Volume 3ml (Standard Mode) Dimension 230mm (L) 120mm (W) 82mm (H) Power Supply 220V AC ± 10% 50Hz 120V AC ± 10% 60Hz Net Weight 1 kg Configurations Standard: Instrument, Sampling needle, Filter, Sealing gasket Optional: Wireless printer, DK-190PC Professional Software, Device for testing ampoule, Standard portable bag