Main functions and effects: ,Connect with PC for querying date. ,300 types of oil data in world market for reference. ,Automatically save oil data with 4GB ROM. ,Automatically form the oil curves with test result. ,Rechargeable Li Battery Product Features ,2.8-Inch TFT color screen with English display. ,Automatic calibration with great testing efficiency. ,Automatic judgment whether the oil chamber clean or not. ,Automatic judge whether have metal particles beyond 60 μm in oil. ,Advanced processor with low power consumption and longer battery service life. ,Automatic shut down in no man operation state. ,Portable aluminium alloy suitcase,more convenient for testing. Applications: For the present THY-23A oil quality analyzer is applied to various fields such as aerospace, oil field, ports, transport, mine, electricity, metallurgy, chemical industry and engineering plant., etc.
The THY-22A oil quality analyzer,adopts low voltage,micro power consumption,signal conditioning and data-processing system,which can be used for a long time powered by the dry battery,the LCD large screen display can be contribute to enable us read measurement dates clearly;the automatic calibration function improves the testing efficiency;the instrument is more suitable for site work and field work by adopting small size volume and portable design. Main functions: Detecting the degree of contaminate in lubricants within 3 minutes. Detecting metal particles byyond 60 microns. Determining whether the newly purchased lubricant is qualified. Main Features Small size,portable enable us to use it by hand. Intelligent,auto 0 -adjusting user friendly operation. LCD screen,make testing results more intuitive.
Product description: The model THY-23A is a portable and intelligent oil quality analyzer.The product can be normally used with Li battery under the system of data processing,low voltage and low power consumption.A 2.8-inch color screen shows operating prompt in English characters of each function that convenient to read various data.Automatic calibration of the analyzer greatly improve the testing efficiency,the analyzer will shut down automatically in no man operation state.Hand- held design is convenient for on-site and wild field use. Main functions: Rapid test oil contaminant, water content in 10 seconds Detecting whether have metal particles in lube oil beyond 60μm Determining the new purchased lubricant is qualified or not Main Features: 2.8-Inch TFT color screen with English display. Automatic calibration with great testing efficiency. Automatic judgment whether the oil chamber clean or not. Automatic judge whether have metal particles beyond 60 μm in oil. Advanced processor with low power consumption and longer battery service life. Automatic shut down in no man operation state. Portable aluminium alloy suitcase,more convenient for testing.
Product Introduction Chromatographic analysis technology is a kind of separation and analysis technology of multi-component mixture. It mainly makes use of the difference of boiling point polarity and absorption add coefficient of each component in the sample in the chromatographic column so that each component can be separated in the chromatographic column and detect the separated components by detection apparatus so as to conduct qualitative and quantitative analysis of multi-component mixture. Because this method has a high separation efficiency fast analysis less sample consumption etc therefore has been widely used in petrochemical biochemical medicine and health food of the health and quarantine inspection of environmental protection industry in the medical clinical departments by gas chromatography in the field of solve the industrial production of intermediates and pollution detection of industrial products quality inspection scientific research production control and other issues. Chromatographic instrumentIt is a kind of high cost performance multi-function economical and practical precision instrument which adopts three-column and three-gas circuit operating system. The basic type is equipped with hydrogen flame ionization detection (FID) and thermal conductivity detection deviceï¼?TCDï¼?. Chromatographic instrumentUsing microcomputer and integrated circuit control English and Chinese interface high degree of self-motion and good reliability operating parameters keyboard setting instrument with power failure protection file storage and call function instrumentLarge screen liquid crystal displayï¼?The detection apparatus and its control assembly unit adopt plug and play control modesimplicity of operator for the instrument to conduct constant temperature and program temperature rise operation column room is equipped with flexible rear door self-motiontemperature control system the column box has excellent performance high precision temperature control quick rise and drop speed and flexible air temperature operation process Reliable easy to expand suitable for a variety of detection and sample combinations. The detector adopts the unitized combination design which is easy to install and maintain. The chromatograph can be configured with a variety of detectors (TCD FID ECD FPD and NPD). According to the user's analysis needs the chromatograph can be configured with up to four detectors at the same time. The chromatograph's injection system can be equipped with a variety of injection devices such as filling column head injection glass lining rapid injection and capillary column divided/undivided injection with diaphragm cleaning function.
Main functions: Determining the degree of contaminate in lubricants within 3 minutes Detecting metal particles beyond 60 micrometer Determining whether the newly purchased lubricant is qualified Main features Small size, portable enable us to use it by hand Intelligent, auto zero adjusting user-friendly operation Lcd screen, make testing results more intutive
Determining the degree of pollution in lubricant within 5 minutes; Detecting percentage of water content in the lubricant within 3 minutes; Detecting metal particles beyond 60um; Determining the new purchased lubricant is qualified or not; Printing the result after finishing the detecting.
Oil quality analyzer (thy-21a) Thy-21a oil quality analyzer is a portable instrument which measures the effect of contamination by detecting changes of dielectric constant that occur in lubricants. Dielectric constant change is directly related to the degradation and the contamination level of the oil and will allow the user to achieve optimized intervals between oil changes. Oil quality analyzer also can detect the percentage of water content without standard oil sample. Main functions: 1. Determining the degree of contaminate in lubricants within 5 minutes 2. Detecting the percentage of water content in lubricants within 3 minutes 3. Detecting metal particles beyond 60 micron 4. Determining whether the newly purchased lubricant is qualified 5. Detecting the percentage of water content without standard sample oil 6. Printing the report after detecting the lubricants. Advantages: 1. Maximization and safe extension of intervals between oil changes 2. Early detection of mechanical failures in conjunction with preventative maintenance procedures 3. Avoidance of unnecessary engine damage resulting from overly used lubricants 4. Reduction in the number of costly and unnecessary laboratory analysis of oil samples. Applications: 1. Diesel engines 2. Gasoline engines 3. Natural gas engines 4. Natural gas turbines 5. Automatic transmissions 6. Any other equipment using synthetic lubricants. Specifications: Range: [0, 99.9]ua Repeatability: 3% Temperature: -15¼--+55¼ Power: 5w Voltage: 220v Weight: 5kg Size: 328*210*130mm Battery: 9.6v ni-mh rechargeable battery.
Thy-18f oil quality analyzer The oil quality analyzer is a portable instrument which measures the effect of contamination and electro-chemical changes that occur in lubricants. It detects and measures the dielectric constant of oil. By comparing the measurements obtained from used and unused oils of the same brand, The oil quality analyzer is able to determine the degree of change in the dielectric constant of the oil. Dielectric change is directly related to the degradation and contamination level of the oil And helps the user to optimize intervals between oil changes and to detect increased mechanical wear And loss of the oils lubricating properties. To facilitate trending the instrument is equipped with a numerical read-out. Advantages 1. Determining the degree of contaminate within 5 minutes; 2. Detecting metal particles beyond 60m; 3. Determining whether the newly purchased lubricant is qualified; 4. Determining whether the lubricant includes light oil; 5. Detecting the percentage of water content below 0.05% within 3 minutes. Specifications The standard oil analyzer has the following specification: Range: 0, +99.9ua Repeatability: 3% Temperature: -20 +55 Power: 5w Voltage: 220v Weight: 4.5kg Size: 285-220-115mm Battery: 9.6v ni-mh rechargeable battery.
FUJI developed the first infrared gas analyzer in Japan to use mass-flow sensors. Since then, we have supplied customers with various types of gas analyzers to support environmental preservation and control efforts. These efforts include measurements of atmospheric pollution and detection of low density of SOx and NOx, generated by incinerating facilities and boilers. FUJI's gas analyzers are widely used to monitor the atmosphere to help maintain a cleaner natural environment.
Scope Petroleum product sulfur content analyzer (x-ray spectroscopy) is in accordance with people's republic of china standard gb / t11140, gb / t17040, astm d4294 requirements specified in design and manufacture of this instrument for the determination of trace sulfur content of petroleum products. Because it uses physical analysis methods, with fast analysis without complicated sample pretreatment, high precision, human error is small, low labor intensity of operators, no pollution, it has been widely used and generally replace other measuring sulfur in the international arena the analytical method. Features 1, with full english operating system, the man-machine interface friendly exchanges. 2, short detection time, automatic test results within 30 seconds; automatic c / h ratio correction, for a variety of samples; 3, large-screen lcd, automatic print measurement data; 4, using the x-ray tube excitation, the instrument can be long-term use, without affecting the source attenuation; 5, the use of physical methods, the analysis does not touch, do not destroy the sample, no chemical reagents; 6, instrument with integrated design, easy maintenance; Technical parameters 1, the scope of analysis: s analysis range can be adjusted by the calibration curve of the selected method. 2, the scope of analysis width: s% max-s% min=9.999%; such as oil: s: 0.001 ~ 9.999%. 3, the inherent error, accuracy of analysis: such as oil: in line with the national standard gb / t 17040, at the same time meet the relevant requirements of american national standard astm d4294. 4, system analysis time: 1 to 999 seconds, the recommended value of 60 seconds. 5, detection limit: 10ppm 6, using the conditions: ambient temperature: 5 ~ + 40 ?, relative humidity: =85% (30 ?), power supply: 220v ± 20v, 50hz. 7, total power consumption:
KLD-B adopts the principle of laser blockage method (laser shading method) to detect the size and number of solid particles in the oil. Based on the measurement, it does the analysis and displays the oil contamination level in various standards (e.g NAS1638, ISO4406, GJB, etc) so as to help the operator be aware of the potential risks and avoid any evitable wear of parts.It can be widely applied to various kinds of oil, such hydraulic oil, lubricating oil, gearbox oil, insulating oil (transformer oil), etc. Highlights: 1. High precision. Adopting the principle of laser blockage method (laser shading method) which is the most efficient method to count the number of particles in liquid. Equipped with high-quality Germany-made transducer, which ensures the precision of counting. 2. Two ways of measurement. Both on-line and sampling measurement are available. 3. Able to display the measurement result in the form of NAS1638, ISO4406, GJB by means of both digits and diagrams. 4. Equipped with big touch screen. Easy for operation and efficient for display. 5. Built-in PC. No need connecting the instrument to another computer, operator could look up the data by various standards such as location, time, operator name, etc, or transfer the data via USB connection. 6. Printer internally installed. Able to print out the measurement result within 45 sec. 7. Lithium battery installed. Suitable for outdoor use. 8. Large data storage volume.160G hard disk. 9. Suitcase design. Light and small. Easy to take along. Technical specification: Weight 10KG Dimension 415mm * 319mm * 168mm Temperature of Tested Oil 0-60 centigrade Operating Ambient Temperature 0-40 centigrade Diameter of Tested Particles 2,5,15,25micron , or 4,6,14,21 micron Viscosity 10-100 cSt(46-2000SUS)plus-minus 20% Hose Connector for Online Measurement M16*2 standard connector Measurement Standard NAS 1638 00-21; ISO4406 01-29; GJB 420A 000-12 Data Storage Volume 160 hard disk Online Working Pressure low pressure:0.3-3Mpa; high pressure: 3-20MPa Online Working Flow Rate 50-300 ml Power Supply AC 220V plus-minus10%; storage battery (optional). Wrapped in see-through plastic bags and packed in stndard export cardboard cartons.
Scope Crude oil and fuel oil precipitate tester for pressing gb / t6531-86 to determine the content of crude oil and fuel oil precipitate "crude and fuel oils precipitate assay (extraction method)" is used for extraction with toluene. This standard is equivalent to international standards iso3735-1975 "crude and fuel oils precipitate assay (extraction method)", crude and fuel oils precipitate analyzer can be programmed to control its heating power. Features 1, the instrument uses dual electric stove, can work independently; 2, the instrument uses 8-bit microcontroller control; 3. The instrument uses three semi-liquid crystal display; 4, the instrument has mains compensation; 5, the instrument automatically controlled heating power; Technical parameters 1, the heating temperature range: room temperature ~ 400 ?; te00000000000mperature accuracy: ± 0.5 ?. 2, the equivalent output voltage adjustable value: 0 ~ 220v 3, electric heater power: 1000 w * 2 4, power: ac 220 v ± 10v, 50 hz ± 1hz
FDR-2601 Crude oil and its products salt content analyzer Scope This instrument conforms to the GB / T6532 standard Features 1, integrated design, easy to operate 2, digital PID temperature control, high accuracy 3, adjustable voltage heating, flexible operation Technical Parameters 1, the control temperature: 60 ± 1 2 operating modes: digital temperature control, electric heating tube 3, Power Supply: AC220V ± 10% 50HZ
FDR-3301 UV fluorescence sulfur analyzer Scope UV fluorescence sulfur analyzer is based on UV fluorescence measurement principle and the development of computer technology combined with a new generation of precision instruments, is currently the most advanced of the total sulfur content tester, in line with ASTM D5453, SH / T 0689 and other standards, the instrument is National total sulfur content of refined oil arbitration standards. Now widely used in the determination of total sulfur content of crude oil, hydrocarbons and fuel, petroleum, plastics, petrochemicals, food and so on. Measurement principle instrument uses ultraviolet fluorescence method, when the sample is introduced into the pyrolysis furnace, cracking occurred sample oxidation of sulfide which quantitatively converted to sulfur dioxide, carried by a carrier gas, off which the water through a membrane dryer, into the reaction chamber, sulfur dioxide absorbing ultraviolet light energy into an excited state of sulfur dioxide (SO2 *), the fluorescence emission of sulfur dioxide when SO2 * to return to a stable state, the energy released by a photomultiplier tube to receive, and then the micro-current amplifier, computer data processing, the amount of reaction with sulfur dioxide emission intensity is proportional to the amount of sulfur dioxide and total sulfur content in the sample is proportional, so the content of the sample can be determined by measuring total sulfur emission intensity. Features 1, computer-controlled operation, enabling interactive, data, peak shape can be automatically stored print. 2, the operating software can be connected with LIMIS system, automatic data transmission. 3, the instrument uses the new quartz pyrolysis tube, the injection volume can be increased to reduce measurement errors, increase the sensitivity of the instrument, higher repeatability. 4, cooling fans, automatic switch, eliminating the need to wait for the shutdown to finish samples trouble, saving time and effort. 5, darkroom system uses the latest technology, the key components imported detecting element to improve the detection accuracy and sensitivity of the instrument. Technical Parameters 1, in line with standards: ASTM D5453, SH / T 0689 and other standards 2, measuring range: 0.2mg / L ~ 10000mg / L ~ percentage 3. Air source: Argon: 99.999% Oxygen: 99.999% 4, sample status: solid, liquid, gas (with corresponding injector) 5, temperature range: room temperature ~ 1100 ? ± 3 ? 6, repeatability error: 0.2mg / L=X
Scope UV fluorescence sulfur analyzer is based on UV fluorescence measurement principle and the development of computer technology combined with a new generation of precision instruments, is currently the most advanced of the total sulfur content tester, in line with ASTM D5453, SH / T 0689 and other standards, the instrument is National total sulfur content of refined oil arbitration standards. Now widely used in the determination of total sulfur content of crude oil, hydrocarbons and fuel, petroleum, plastics, petrochemicals, food and so on. Measurement principle instrument uses ultraviolet fluorescence method, when the sample is introduced into the pyrolysis furnace, cracking occurred sample oxidation of sulfide which quantitatively converted to sulfur dioxide, carried by a carrier gas, off which the water through a membrane dryer, into the reaction chamber, sulfur dioxide absorbing ultraviolet light energy into an excited state of sulfur dioxide (SO2 *), the fluorescence emission of sulfur dioxide when SO2 * to return to a stable state, the energy released by a photomultiplier tube to receive, and then the micro-current amplifier, computer data processing, the amount of reaction with sulfur dioxide emission intensity is proportional to the amount of sulfur dioxide and total sulfur content in the sample is proportional, so the content of the sample can be determined by measuring total sulfur emission intensity. Features 1, computer-controlled operation, enabling interactive, data, peak shape can be automatically stored print. 2, the operating software can be connected with LIMIS system, automatic data transmission. 3, the instrument uses the new quartz pyrolysis tube, the injection volume can be increased to reduce measurement errors, increase the sensitivity of the instrument, higher repeatability. 4, cooling fans, automatic switch, eliminating the need to wait for the shutdown to finish samples trouble, saving time and effort. 5, darkroom system uses the latest technology, the key components imported detecting element to improve the detection accuracy and sensitivity of the instrument. 6, equipment imported membrane dryer to absorb , eliminating the need to frequently replace magnesium perchlorate of trouble, while reducing the leakage problem. 7, using computer control of temperature, improve the instrument precision temperature control, and difficult to over-temperature. 8, using air instead of water cooling, saving water resources. 9, can be adjusted to take existing calibration curve calibrated using a standard sample after sample analysis. Technical Parameters 1, in line with standards: ASTM D5453, SH / T 0689 and other standards 2, measuring range: 0.2mg / L ~ 10000mg / L ~ percentage 3. Air source: Argon: 99.999% Oxygen: 99.999% 4, sample status: solid, liquid, gas (with corresponding injector) 5, temperature range: room temperature ~ 1100 ? ± 3 ? 6, repeatability error: 0.2mg / L=X
Scope Distillate fuel oil oxidation stability tester side given instrument (accelerated method) according to sh / t0175-94, astmd2274 and other standards to determine the initial boiling point of not lower than 175 ?, 90% point distillation temperature no higher than 370 ? of middle distillate fuels inherent stability and performance of the oil. I.E., in the case of an active metal surface and the water or dirt and other environmental factors do not exist, the sample is exposed to the atmosphere in the ability of anti-change. Features 1, the fixed value regulator valve to provide a constant flow of oxygen test. 2, thermostatic bath, large capacity, good insulation properties, and can make six samples tested. 3, oxidation tube with radial clamping, easy operation and reliable. 4, the camera obscura after the oxidation test tube directly into which were cooled at room temperature 5, sample oxidation time automatic control, when the alarm system. 6, the instrument uses metal bath, heating speed, good stability, environmental protection Technical parameters 1, oxidation flowmeter: six oxidation test flow meter can be adjusted individually, the test flow rate: 50 ± 5ml / min. 2, constant temperature bath: the use of fld metal bath. 3, the thermometer: in line with gb / t514-83 standard, wlh-33c, 50-100 ?, 0.5 ? indexing rod 4. Temperature control mode: automatic heating, automatic temperature control 5, temperature accuracy: 95 ± 0.2 ? 6, oxidation tube: borosilicate glass, in line with sh / t0175-94 standard 7, electric heaters: when the main heater 220v 2500w, auxiliary heating 800w. 8, the regulator valve oxidation: oxidation is the oxidation stability, in front of the flow meter with regulator valve
Features 1, the instrument adopts the automatic tube furnace test method, program control tube furnace heating and moving 2, the instrument adopts the super thermal insulation material, is the tube furnace can work under high temperature 3, the instrument adopts the intelligent control system, with temperature setting, time setting and alarm function detection 4, the instrument uses a timing device, the alarm prompt
Cocoa oil Fat Content Analyzer PQ001-20-010V is one of the PQ001 series device. This Device is mainly used in determination of cocoa oil's solid fat. Because this feature, Cocoa oil Fat Content Analyzer PQ001-20-010V is widely applied in food and agriculture.
The portable model THY-23A Oil Quality Analyzer is an intelligent product,with high performance of anti-interference ability and low power consumption.The analyzer with high sensitivity, resolution, stability and good repetitiveness.It uses rechargeable Li-Battery, especially suitable for the production on-site work and field environment work. Technical Specifications: Measuring Range 0 -199.9 Water Content Measuring Range:0.01% - 20% Repetitive Error:±2% ROM:4GB Power Supply:5V/1A Power Adapter/Rechargeable Li Battery Total Power Consumption 0.3W Environmental Temperature Net.Weight:0.4kg Size 20 10045mm
Features 1, high reliability design, efficient brushless motor; 2, the high-performance single-chip control, mature technology, simple operation, high efficiency analysis, analysis of low cost; 3, analysis of the memory speed, temperature, time, work status and display are Automatic control completed; 4, low power consumption, low noise, reliable performance, good stability, easy maintenance, long service life; 5, equipped with electronic locks to ensure the safe use of equipment.