Main functions and effects:
,Connect with PC for querying date.
,300 types of oil data in world market for reference.
,Automatically save oil data with 4GB ROM.
,Automatically form the oil curves with test result.
,Rechargeable Li Battery
Product Features
,2.8-Inch TFT color screen with English display.
,Automatic calibration with great testing efficiency.
,Automatic judgment whether the oil chamber clean or not.
,Automatic judge whether have metal particles beyond 60 μm in oil.
,Advanced processor with low power consumption and longer battery service life.
,Automatic shut down in no man operation state.
,Portable aluminium alloy suitcase,more convenient for testing.
Applications:
For the present THY-23A oil quality analyzer is applied to various fields such as aerospace, oil field, ports, transport, mine, electricity, metallurgy, chemical industry and engineering plant., etc.
The THY-22A oil quality analyzer,adopts low voltage,micro power consumption,signal conditioning and data-processing system,which can be used for a long time powered by the dry battery,the LCD large screen display can be contribute to enable us read measurement dates clearly;the automatic calibration function improves the testing efficiency;the instrument is more suitable for site work and field work by adopting small size volume and portable design. Main functions: Detecting the degree of contaminate in lubricants within 3 minutes. Detecting metal particles byyond 60 microns. Determining whether the newly purchased lubricant is qualified. Main Features Small size,portable enable us to use it by hand. Intelligent,auto 0 -adjusting user friendly operation. LCD screen,make testing results more intuitive.
Product description: The model THY-23A is a portable and intelligent oil quality analyzer.The product can be normally used with Li battery under the system of data processing,low voltage and low power consumption.A 2.8-inch color screen shows operating prompt in English characters of each function that convenient to read various data.Automatic calibration of the analyzer greatly improve the testing efficiency,the analyzer will shut down automatically in no man operation state.Hand- held design is convenient for on-site and wild field use. Main functions: Rapid test oil contaminant, water content in 10 seconds Detecting whether have metal particles in lube oil beyond 60μm Determining the new purchased lubricant is qualified or not Main Features: 2.8-Inch TFT color screen with English display. Automatic calibration with great testing efficiency. Automatic judgment whether the oil chamber clean or not. Automatic judge whether have metal particles beyond 60 μm in oil. Advanced processor with low power consumption and longer battery service life. Automatic shut down in no man operation state. Portable aluminium alloy suitcase,more convenient for testing.
Main functions: Determining the degree of contaminate in lubricants within 3 minutes Detecting metal particles beyond 60 micrometer Determining whether the newly purchased lubricant is qualified Main features Small size, portable enable us to use it by hand Intelligent, auto zero adjusting user-friendly operation Lcd screen, make testing results more intutive
Oil quality analyzer (thy-21a) Thy-21a oil quality analyzer is a portable instrument which measures the effect of contamination by detecting changes of dielectric constant that occur in lubricants. Dielectric constant change is directly related to the degradation and the contamination level of the oil and will allow the user to achieve optimized intervals between oil changes. Oil quality analyzer also can detect the percentage of water content without standard oil sample. Main functions: 1. Determining the degree of contaminate in lubricants within 5 minutes 2. Detecting the percentage of water content in lubricants within 3 minutes 3. Detecting metal particles beyond 60 micron 4. Determining whether the newly purchased lubricant is qualified 5. Detecting the percentage of water content without standard sample oil 6. Printing the report after detecting the lubricants. Advantages: 1. Maximization and safe extension of intervals between oil changes 2. Early detection of mechanical failures in conjunction with preventative maintenance procedures 3. Avoidance of unnecessary engine damage resulting from overly used lubricants 4. Reduction in the number of costly and unnecessary laboratory analysis of oil samples. Applications: 1. Diesel engines 2. Gasoline engines 3. Natural gas engines 4. Natural gas turbines 5. Automatic transmissions 6. Any other equipment using synthetic lubricants. Specifications: Range: [0, 99.9]ua Repeatability: 3% Temperature: -15¼--+55¼ Power: 5w Voltage: 220v Weight: 5kg Size: 328*210*130mm Battery: 9.6v ni-mh rechargeable battery.
Thy-18f oil quality analyzer The oil quality analyzer is a portable instrument which measures the effect of contamination and electro-chemical changes that occur in lubricants. It detects and measures the dielectric constant of oil. By comparing the measurements obtained from used and unused oils of the same brand, The oil quality analyzer is able to determine the degree of change in the dielectric constant of the oil. Dielectric change is directly related to the degradation and contamination level of the oil And helps the user to optimize intervals between oil changes and to detect increased mechanical wear And loss of the oils lubricating properties. To facilitate trending the instrument is equipped with a numerical read-out. Advantages 1. Determining the degree of contaminate within 5 minutes; 2. Detecting metal particles beyond 60m; 3. Determining whether the newly purchased lubricant is qualified; 4. Determining whether the lubricant includes light oil; 5. Detecting the percentage of water content below 0.05% within 3 minutes. Specifications The standard oil analyzer has the following specification: Range: 0, +99.9ua Repeatability: 3% Temperature: -20 +55 Power: 5w Voltage: 220v Weight: 4.5kg Size: 285-220-115mm Battery: 9.6v ni-mh rechargeable battery.
Scope Petroleum product sulfur content analyzer (x-ray spectroscopy) is in accordance with people's republic of china standard gb / t11140, gb / t17040, astm d4294 requirements specified in design and manufacture of this instrument for the determination of trace sulfur content of petroleum products. Because it uses physical analysis methods, with fast analysis without complicated sample pretreatment, high precision, human error is small, low labor intensity of operators, no pollution, it has been widely used and generally replace other measuring sulfur in the international arena the analytical method. Features 1, with full english operating system, the man-machine interface friendly exchanges. 2, short detection time, automatic test results within 30 seconds; automatic c / h ratio correction, for a variety of samples; 3, large-screen lcd, automatic print measurement data; 4, using the x-ray tube excitation, the instrument can be long-term use, without affecting the source attenuation; 5, the use of physical methods, the analysis does not touch, do not destroy the sample, no chemical reagents; 6, instrument with integrated design, easy maintenance; Technical parameters 1, the scope of analysis: s analysis range can be adjusted by the calibration curve of the selected method. 2, the scope of analysis width: s% max-s% min=9.999%; such as oil: s: 0.001 ~ 9.999%. 3, the inherent error, accuracy of analysis: such as oil: in line with the national standard gb / t 17040, at the same time meet the relevant requirements of american national standard astm d4294. 4, system analysis time: 1 to 999 seconds, the recommended value of 60 seconds. 5, detection limit: 10ppm 6, using the conditions: ambient temperature: 5 ~ + 40 ?, relative humidity: =85% (30 ?), power supply: 220v ± 20v, 50hz. 7, total power consumption:
Scope Crude oil and fuel oil precipitate tester for pressing gb / t6531-86 to determine the content of crude oil and fuel oil precipitate "crude and fuel oils precipitate assay (extraction method)" is used for extraction with toluene. This standard is equivalent to international standards iso3735-1975 "crude and fuel oils precipitate assay (extraction method)", crude and fuel oils precipitate analyzer can be programmed to control its heating power. Features 1, the instrument uses dual electric stove, can work independently; 2, the instrument uses 8-bit microcontroller control; 3. The instrument uses three semi-liquid crystal display; 4, the instrument has mains compensation; 5, the instrument automatically controlled heating power; Technical parameters 1, the heating temperature range: room temperature ~ 400 ?; te00000000000mperature accuracy: ± 0.5 ?. 2, the equivalent output voltage adjustable value: 0 ~ 220v 3, electric heater power: 1000 w * 2 4, power: ac 220 v ± 10v, 50 hz ± 1hz
FDR-2601 Crude oil and its products salt content analyzer Scope This instrument conforms to the GB / T6532 standard Features 1, integrated design, easy to operate 2, digital PID temperature control, high accuracy 3, adjustable voltage heating, flexible operation Technical Parameters 1, the control temperature: 60 ± 1 2 operating modes: digital temperature control, electric heating tube 3, Power Supply: AC220V ± 10% 50HZ
FDR-3301 UV fluorescence sulfur analyzer Scope UV fluorescence sulfur analyzer is based on UV fluorescence measurement principle and the development of computer technology combined with a new generation of precision instruments, is currently the most advanced of the total sulfur content tester, in line with ASTM D5453, SH / T 0689 and other standards, the instrument is National total sulfur content of refined oil arbitration standards. Now widely used in the determination of total sulfur content of crude oil, hydrocarbons and fuel, petroleum, plastics, petrochemicals, food and so on. Measurement principle instrument uses ultraviolet fluorescence method, when the sample is introduced into the pyrolysis furnace, cracking occurred sample oxidation of sulfide which quantitatively converted to sulfur dioxide, carried by a carrier gas, off which the water through a membrane dryer, into the reaction chamber, sulfur dioxide absorbing ultraviolet light energy into an excited state of sulfur dioxide (SO2 *), the fluorescence emission of sulfur dioxide when SO2 * to return to a stable state, the energy released by a photomultiplier tube to receive, and then the micro-current amplifier, computer data processing, the amount of reaction with sulfur dioxide emission intensity is proportional to the amount of sulfur dioxide and total sulfur content in the sample is proportional, so the content of the sample can be determined by measuring total sulfur emission intensity. Features 1, computer-controlled operation, enabling interactive, data, peak shape can be automatically stored print. 2, the operating software can be connected with LIMIS system, automatic data transmission. 3, the instrument uses the new quartz pyrolysis tube, the injection volume can be increased to reduce measurement errors, increase the sensitivity of the instrument, higher repeatability. 4, cooling fans, automatic switch, eliminating the need to wait for the shutdown to finish samples trouble, saving time and effort. 5, darkroom system uses the latest technology, the key components imported detecting element to improve the detection accuracy and sensitivity of the instrument. Technical Parameters 1, in line with standards: ASTM D5453, SH / T 0689 and other standards 2, measuring range: 0.2mg / L ~ 10000mg / L ~ percentage 3. Air source: Argon: 99.999% Oxygen: 99.999% 4, sample status: solid, liquid, gas (with corresponding injector) 5, temperature range: room temperature ~ 1100 ? ± 3 ? 6, repeatability error: 0.2mg / L=X