FEATURES * Oxygen pressure range 2 mbar - 3bar * Zirconium dioxide (ZrO2 ) sensing elements * Non-consumption technology * Integral heating element * No need for temperature stabilisation * No reference gas required * High accuracy * Linear output signal * Operates with external interface boards SPECIFICATIONS Heater Voltage Porous Cap (15mm) 4.35V DC ± 0.1V DC (1.85A) Stand by 2V DC (0.85A) Pump resistance @ 700'C < 6k� Permissible gas temperature -100 to 250'C Gas flow rate 0 to 10 m/s Repetitive permissible acceleration 5 g Incidental permissible acceleration 30 g z
Features * oxygen pressure range 2 mbar - 3bar * zirconium dioxide (zro2 ) sensing elements * non-consumption technology * integral heating element * no need for temperature stabilisation * no reference gas required * high accuracy * linear output signal * operates with external interface boards Specifications Heater voltage: Porous cap (15mm): 4.35v dc +/- 0.1v dc (1.85a) Stand by: 2v dc (0.85a) Pump resistance @ 700'C: < 6kOhm Permissible gas temperature: -100 to 250C Gas flow rate: 0 to 10 m/s Repetitive permissible acceleration: 5 g Incidental permissible acceleration: 30 g
Zirconia O2 Sensors Probe Series - Short Housing The Probe Range of zirconium dioxide oxygen sensors are available in three lengths. Suitable for aggressive and polluted applications such as boiler exhausts. Longer probes are an ideal solution for thicker walled, insulated flue pipes. FEATURES * Zirconium dioxide (ZrO2) sensing elements * Long life, non-depleting technology * Integral heating element * High accuracy * Requires an external interface board to operate BENEFITS * No reference gas required * No need for temperature stabilisation * Compact enclosure TECHNICAL SPECIFICATIONS Heater voltage Operating (standard response) 4V DC ± 0.1V DC (1.7A) Standby 1.65V DC (0.7A) Operating (fast response) 4.35V DC ± 0.1V DC (1.85A) Standby 2V DC (0.85A) Pump impedance at 700'C < 6kΩ Permissible gas temperature -100'C to +250'C Gas flow rate 0 ~ 10 m/s Repetitive permissible acceleration 5g Incidental permissible acceleration 30g OUTPUT VALUES Oxygen pressure range 2mbar ~ 3bar max Accuracy 5mbar max Internal operational temperature 700'C Response time (10 - 90% step) Standard response sensor < 15s Fast response sensor < 4s Warm up time (prior to sensor operation) 60s Warm up time (from standby) 20s Output stabilisation time ~ 180s
Zirconia o2 sensors Flange mounted series The flange mount zirconium dioxide oxygen sensor is designed for easy sealing into a manifold or sampling chamber. Favoured by ssts aerospace customers and in applications that require high temperature and pressure operation. O2s-fr-t4-4p flange zirconia o2 sensors features Zirconium dioxide (zro2) sensing elements Long life, non-depleting technology Integral heating element High accuracy Requires an external interface board to operate O2s-fr-t4-4p flange zirconia o2 sensors benefits No reference gas required No need for temperature stabilisation Flange mounting O2s-fr-t4-4p flange zirconia o2 sensors technical specifications Heater voltage Operating: 4.35vdc ± 0.1vdc (1.85a) Standby: 2vdc (0.85a) Pump impedance at 700'c: < 6k Permissible gas temperature: -100'c to +400'c Gas flow rate: 0 - 10 m/s Repetitive permissible acceleration : 5g Incidental permissible acceleration: 30g O2s-fr-t4-4p flange zirconia o2 sensors output values Oxygen pressure range: 2mbar - 3bar max Accuracy: 5mbar max Internal operational temp: 700'c Response time (10 - 90% step): < 4s Warm up time (prior to sensor operation): 60s Warm up time (from standby): 20s Output stabilisation time: ~ 180s
Features * oxygen pressure range 2 mbar - 3bar * zirconium dioxide (zro2 ) sensing elements * non-consumption technology * integral heating element * no need for temperature stabilisation * no reference gas required * high accuracy * linear output signal * operates with external interface boards * pcb mountable Specifications Heater supply* Porous lid cap 4vdc +/- 0.1vdc (1.7a) Stand by 1.65vdc (0.7a) Full porous cap 4.35v dc +/- 0.1v dc (1.85a) Stand by 2v dc (0.85a)
Features * oxygen pressure range 2 mbar - 3bar * zirconium dioxide (zro2 ) sensing elements * non-consumption technology * integral heating element * no need for temperature stabilisation * no reference gas required * high accuracy * linear output signal * operates with external interface boards * 80mm, 220mm and 400mm probes available Specifications Heater supply* Porous lid cap 4v dc +/- 0.1v dc (1.7a) Stand by 1.65v dc (0.7a) Full porous cap 4.35v dc +/- 0.1v dc (1.85a) Stand by 2v dc (0.85a)
Features: oxygen pressure range 2 mbar - 3bar zirconium dioxide (zro2 ) sensing elements non-consumption technology integral heating element no need for temperature stabilisation no reference gas required high accuracy linear output signal operates with external interface boards Specifications Heater supply* Full porous cap 4.35v dc +/- 0.1v dc (1.85a) Stand by 2 v dc (0.85a)
(LME standards) Standard Cu Cathode-1, purity 99, 97-99, 99 %Dimension: 914 mm x 914 mm x 12 mm (LME standards) Copper (Cu) min% 99.99% Other materials may be present which are described below: Oxygen O2 -- Sulfur S 4 PPM Iron Fe 2 PPM Silver(Argent 10 PPM Lead Pb 0.2 PPM Nickel Ni 0.2 PPM Selenium Se 0.3 PPM Antimony Sb 0.1 PPM Silica Si 0.3 PPM Cobalt Co 0.2 PPM Arsenic As 0.1 PPM Bismuth Bi 0.1 PPM Manganese Mn 0.1 PPM Tellurium Te 0.05 PPM Aluminum Al 0.5 PPM Magnesium Mg 0.4 PPM Zinc Zn 0.4 PPM
(LME standards) Standard Cu Cathode-1, purity 99, 97-99, 99 %Dimension: 914 mm x 914 mm x 12 mm (LME standards) Copper (Cu) min% 99.99% Other materials may be present which are described below: Oxygen O2 -- Sulfur S 4 PPM Iron Fe 2 PPM Silver(Argent 10 PPM Lead Pb 0.2 PPM Nickel Ni 0.2 PPM Selenium Se 0.3 PPM Antimony Sb 0.1 PPM Silica Si 0.3 PPM Cobalt Co 0.2 PPM Arsenic As 0.1 PPM Bismuth Bi 0.1 PPM Manganese Mn 0.1 PPM Tellurium Te 0.05 PPM Aluminum Al 0.5 PPM Magnesium Mg 0.4 PPM Zinc Zn 0.4 PPM
Features * oxygen pressure range 2 mbar - 3bar * zirconium dioxide (zro2) sensing elements * non-consumption technology * integral heating element * no need for temperature stabilisation * no reference gas required * high accuracy * linear output signal * operates with external interface boards * m18x1.5 screw mount Specifications Heater voltage* 4.35v dc +/- 0.1v dc (1.85a) Stand by 2v dc (0.85a)
Zirconia o2 sensors Miniature series The miniature zirconium dioxide oxygen sensors can be pcb mounted and are used when measuring ambient gas with the complete sensor immersed in the atmosphere which is to be measured. Features * zirconium dioxide (zro2 ) sensing elements * long life, non-depleting technology * integral heating element * high accuracy * requires an external interface board to operate Benefits * no reference gas required * no need for temperature stabilisation * pcb mountable Technical specifications Heater voltage Standard response sensor: 4v dc â± 0.1v dc (1.7a) Standby: 1.65v dc (0.7a) Fast response sensor: 4.35v dc â± 0.1v dc (1.85a) Standby: 2v dc (0.85a) Pump impedance at 700'c: < 6k Permissible gas temperature: -100'c to +250'c Gas flow rate : 0 - 10 m/s Repetitive permissible acceleration: 5g Incidental permissible acceleration: 30g Output values Oxygen pressure range: 2mbar - 3bar max Accuracy: 5mbar max Internal operational temperature: 700'c Response time (10 - 90% step) Standard response sensor:
Silicon Dioxide, E551, CAS no.7631-86-9, white powder. Silicon dioxide (SiO2), also known as silica, is a natural compound made of two of the earth's most abundant materials: silicon (Si) and oxygen (O2). Silicon Dioxide is a common additive in the production of foods, where it is used primarily as a flow agent in powdered foods, or to absorb water in hygroscopic applications used in silica gel, control moisture levels to avoid prevent certain goods from going bad. It is often used in cheese, fat spreads, confectionery, dried vegetables, etc. As an experienced Silicon Dioxide manufacturer and supplier, we has been supplying and exporting Silicon Dioxide for almost 10 years, please be assured to buy from us. Any inquiries about price and the market trend please feel free to contact us, we will reply you within 1 working day. Silicon Dioxide Specification Item Standard Appearance White powder Purity (SiO2, %) 96 Oil absorption (cm3/g) 2.0~ 3.0 Loss on drying (%) 4.0~ 8.0 Loss on ignition (%) 8.5 BET (m2/g) 170~ 240 pH (10% solution) 5.0~ 8.0 Sodium sulfate (as Na2SO4, %) 1.0 Arsenic (As) 3mg/kg Lead (Pb) 5 mg/kg Cadium (Cd) 1 mg/kg Mercury (Hg) 1 mg/kg Total heavy metals (as Pb) 20 mg/kg Total plate count 500cfu/g Salmonella spp./ 10g Negative Escherichia coli/ 5g Negative
Thank you for purchasing and using our company's ultrasonic oxygen concentration / flow sensor. 1, please carefully read the instructions and fully understand the contents of the sensor after operation and maintenance. Improper use may cause damage to the sensor. (no violent impact and falling ground) 2, without the consent of the company, it is strictly prohibited to alter the structure and components of the sensor without authorization. The company is not responsible for any personal safety incidents or sensor abnormalities caused by unauthorized alterations. 3, the specifications and instruction contents of this sensor may be changed due to the technical improvement of the product. 4, this instruction manual must be handed to the actual user of the sensor and stored in it, and placed at any time where the actual user of the sensor can access it. 5, the company has the right to interpret the instructions for the sensor. 2ã??technical parameter Measurement parameters measuring method range Resolution accuracy O2 Ultrasonic 20.5%-95.6% 0.1% �±1.8%FS 5-45â?? Note: the range can be customized according to customer requirements. Sample gas requirements Water removal (no condensation); dust filtration (
O2-M2 Oxygen Sensor Description Alphasense Oxygen sensors use capillary flow control. Unlike partial pressure oxygen sensors, they have good pressure and temperature dependence, making them the best choice in safety applications. Standard galavanic sensors use lead for greatest reliability but fixed lifetime. Specifications * Output: 80 to 120 uA @ 20.9% O2 * Response time t90: < 15 (s) from 20.9% to 0% O2 * Linearity: 0.6 % O2 deviation @ 10% O2 * Operating life: > 24 months *Temperature range: -30 to 55 'C * Pressure range: 80 to 120 kPa * Humidity range: 5 to 95 % rh continuous * Diameter: 20.0 mm (including label) * Heigh: 17.4 mm (including foam ring) * Weight: < 16g
O2-a2 oxygen sensor Performance Output î¼a @ 20.9% o2 80 to 120 Response time t90 (s) from 20.9% to 0% o2 < 15 Zero current î¼a in n2 < 2.5 Linearity % o2 deviation @ 10% o2 0.6 Lifetime Output drift % change in output @ 3 months < 1 Operating life months until 85% original output of 20.9% o2 > 24 Environmental Humidity sensitivity % o2 change: 0% to 95% rh @ 40â?? < 0.7 Co sensitivity % (change o2 reading) / % co2 @ 5% co2 0.1 Pressure sensitivity (% change of output)/(% change of pressure) @ 20kpa < 0.1 Key specifications Temperature range â?? -30 to 55 Pressure range kpa 80 to 120 Humidity range % rh non-condensing (0 to 99% rh short term) 5 to 95 Storage period months @ 3 to 20â?? (store in sealed pot, open circuit) 6 Load resistor î© (recommended) 47 to 100 Diameter mm (including label) 20.0 Height mm (including foam ring) 17.4 Weight g < 16 -
Zirconia O2 Sensors Probe Series - Long Housing FEATURES * Zirconium dioxide (ZrO2) sensing elements * Long life, non-depleting technology * Integral heating element * High accuracy * Requires an external interface board to operate BENEFITS * No reference gas required * No need for temperature stabilisation * Two lengths available; 220mm and 400mm TECHNICAL SPECIFICATIONS Heater voltage Operating 4V DC ± 0.1V DC (1.7A) Standby 1.65V DC (0.7A) Pump impedance at 700'C < 6kohm Permissible gas temperature Standard temperature -100'C to +250'C High temperature -100'C to +400'C Gas flow rate 0 - 10 m/s Repetitive permissible acceleration 5g Incidental permissible acceleration 30g OUTPUT VALUES Oxygen pressure range 2mbar - 3bar max Accuracy 5 mbar max Internal operational temperature 700'C Response time (10 - 90% step) < 15s Warm up time (prior to sensor operation) 100s Warm up time (from stand by) 20s Output stabilisation time ~ 180s
Oxygen sensor o2 gas sensor for portable gas detector Model number: o2-a2 Performance Output µa @ 20.9% o2 80 to 120 Response time t90 (s) from 20.9% to 0% o2 < 15 Zero current µa in n2 < 2.5 Linearity % o2 deviation @ 10% o2 0.6 Lifetime Output drift % change in output @ 3 months < 1 Operating life months until 85% original output of 20.9% o2 > 24 Environmental Humidity sensitivity % o2 change: 0% to 95% rh @ 40°c < 0.7 Co2 sensitivity % (change o2 reading) / % co2 @ 5% co2 0.1 Pressure sensitivity (% change of output)/(% change of pressure) @ 20kpa < 0.1 Key specifications Temperature range °c -30 to 55 Pressure range kpa 80 to 120 Humidity range % rh continuous (0 to 99% rh short term) 5 to 95 Storage period months @ 3 to 20°c (store in sealed pot, open circuit) 6 Load resistor o (recommended) 47 to 100 Diameter mm (including label) 20.0 Height mm (including foam ring) 17.4 Weight g < 16
optical oxygen sensor O2 Gas sensor LOX-02 Description The LuminOx Family is a range of factory calibrated optical sensors which measure ambient O2levels using the principle of fluorescence quenching by oxygen. Our unique patented process allows us to produce an oxygen sensor that benefits from low power, traditionally associated with electrochemical sensing devices, while providing a much longer lifetime due to the non-depleting sensing principle. Applications Typical applications for the Cheap Price Oxygen Sensor LOX-02 are; Oxygen detection Portable equipment Breathing apparatus Inerting Medical Lab equipment Agriculture Incubation Fore prevention Flue gas in condensing boilers