CM500A 600A AC Clamp Meter CM510A 600A AC Clamp Meter (Temperature function) CM520A 400A DC/AC Clamp Meter CM530A 600A DC/AC Clamp Meter CM550A 1020KVA Power DC Clamp Meter CM210C 20.00A~200A DC/AC Mini Clamp Meter CM210E 2.000 A~200A DC/AC Mini Clamp Meter CTA600 600A AC A Current Clamp Meter Module
The Fluke 303 comes with all the rugged, reliable and accurate features you have come to trust, in a small, ergonomic design. The innovative body design offers a more compact tool to meet your needs. With features of AC current measurements up to 600 A, a large 30 mm jaw opening and CAT IV 300 V/CAT III 600 V safety rating, you get an easy-to-use tool that handles your everyday electrical maintenance needs. Key features 600 A ac current measurement Cat IV 300V / CAT III 600V safety rated 30 mm jaw size for numerous applications Resistance range of 40 k? Slim, ergonomic design is easy to carry and simple to use Easy to read backlight display Reviews
GF312B2 portable three phase reference meter high accuracy 0.02%, with all kinds of optional clamp on ct and smart optical sampler. It can be applied in electrical laboratory or on site. it will be ensured by a combination of measures such as the use of 24bit A/D converter. APPLICATION: Power plant; Electrical laboratory; Energy meter R & D; Watt-hour meter factory; Metrological service center; Electricity power bureau & power company;
Function Measuring Range Accuracy DC Voltage 600V +/-1.0% AC Voltage 450V +/-1.2% AC Current 20-200-400A +/-2.0% Resistance 200KOHM +/-1.0% Diode Test YES Data hold YES Buzzer YES Power Supply (AAA)1.5*2 Max. Display 1999 Dimensions 150*63*28mm Weight 160g Standard Accessories Test Leads, Manual.
GF312B2 portable three phase reference meter high accuracy 0.02%, with all kinds of optional clamp on ct and smart optical sampler. It can be applied in electrical laboratory or on site. it will be ensured by a combination of measures such as the use of 24bit A/D converter, DSP 32 bit ARM technology, a widely measuring range 600V/120A, adapted to typical test points of most recognized national metrological institutes. It can be as high precision three phase reference energy meter, also three phase portable meter calibrator, test ct pt ratio, burden etc.
Function random phase measurement, AC current and leak current measurement, AC Voltage detection, distinguish the inductive circuit and capacitive circuit, sequence of three-phase voltage detection and connection group of transformer detection, etc. Power supply DC9V alkaline dry battery LR6f-6 continuous duty :300h LCD 3-1/2 LCD display Dimension Width *length* thick·ª92mmf-192mmf-50mm LCD dimension Display domain·ª64mmf-54mm ·+font high·ª40mm Clamp mouth ¬+7.5mm ·+¬+40mm lectotype·¼ Measuring range phase·ª0~360fp·+current·ª0~200mA/2A/10A·+voltage·ª0~20V/200V/500V resolution phase·ª1fp·+current·ª0.1mA·+voltage·ª0.01V Measurement accuracy ·+50Hz,23f¦f+1f¦·+40-60%RH·¼ phase·ªf+3fp current·ªf+1%f+2dgt Voltage·ªf+1.2%f+2dgt line voltage Line test under AC500V Sampling speed About 3 times /s Signal frequency sine wave 45Hz~55Hz ¬-=0.05 Data hold Data holding function·ªdisplayed by fªDHfª symbol Back light function Blue back light ,suit for dark occasion Automatic shutdown After starting up 15min·+it shutdown automatically to reduce battery consumption Battery voltage When battery voltage is low ,battery low voltage symbol will filker to remind replacing battery; Quality Core about590g·+with battery·¼·+long flat nose current pliers about ·ª175gf-2·+big round tongs clamp·ª120g Work temperature and moisture -10f¦~40f¦·+85%rh below Storage temperature and moisture -20f¦~60f¦·+70%rh below Driving point impedance AC voltage driving point impedance·ª2M¬+·+when test phase U1-U2·ª40K¬+ Insulation intension fª10M¬+9·+Between wire of meter and crust·+two voltage input port·¼ Voltage bear Between port of voltage input and box, split core type currenttransformator and clamp handle& winding coil: 1000V/50Hz, 1min experiment can be reach when sine wave AC voltage 500V/50Hz between port of voltage input. 92*192*50(mm)
Description UT200+ series handheld automatic range true RMS clamp meter, designed according to safety standard EN61010-2010 CAT II600V/CAT III 300V grade, with full-function gear anti-burn protection, can meet high reliability and high safety operation requirements; It contains the basic functions of electrical measurement, with high precision measurement, and expands the current frequency (UT201+ / UT202+ only), high voltage frequency function, UT202+ has temperature measurement function, UT203+ has DC current measurement function, and the new design makes it An excellent measurement tool for electronic and electricians with superior performance Features: Large screen LCD display, fast ADC / analog to digital converter Full-featured false detection protection, overvoltage, overcurrent alarm prompt True RMS; voltage measurement 600V With high voltage frequency measurement AC current measurement function With current frequency measurement function (UT201+/UT202+UT202A+ only) Temperature measurement function (UT202+/UT204+ only) Capacitance measurement function (UT202+max 4mF/UT203+max 40mF/UT202A+/UT204+max 60mF) NCV electric field detection with sound and light alarm prompt; LIVE live line measurement (UT202A+/UT204+ only) Specification Range UT201+ UT202+ UT202A+ UT203+ UT204+ AC current (A) 400A (2%+10) (2%+10) (2.5%+5) 600A (2%+10) (2.5%+5) AC current frequency (Hz) 50Hz~100Hz (1%+5) (1%+5) (1%+5) DC current (A) 400A (2.5%+5) 600A (2.5%+5) AC voltage (V) 600V (0.8%+5) (0.8%+5) (0.8%+5) (0.8%+5) (0.8%+5) AC voltage frequency(Hz) 10Hz~10kHz (1%+5) (1%+5) (1%+5) 10Hz~60kHz (0.5%+2) (0.5%+2) DC voltage (A) 600V (0.5%+2) (0.5%+2) (0.5%+2) (0.5%+2) (0.5%+2) Resistance (�©) 40M�© (0.8%+2) (0.8%+2) (0.8%+2) 60M�© (0.8%+2) (0.8%+2) Capacitance (F) 4mF (4%+5) 40mF (4%+5) 60mF (4%+5) (4%+5) Temperature () -40~1000 (1.5%+5) (1.5%+5) Frequency (Hz) 10Hz~10MHz (0.1%+4) (0.1%+4) (0.1%+4) Features Display count 4000 4000 6000 4000 6000 Auto range Jaw opening 28mm 28mm 28mm 28mm 28mm True RMS NCV Live wire test Continuity test Diode MAX/MIN Relative mode Zero mode Data hold Low battery indication Auto power off General Characterisitics Power 1.5V battery (R03) x 2(Not included for air shipping) Display 37mm x 25mm Product color Red and grey Product net weight UT203+:235g Product size 215mm x 63mm x 36mm Standard accessories UT203+: test leads, Standard individual packing Gift box, Carring bag, English manual
GF111B single phase reference energy meter with 100a clamp on ct is the latest product launched by our company after extensive visits to users and drawing on the advantages of similar products at domestic and abroad. The measurement part of the product adopts high-speed A D converter and DSP for digital processing technology, which greatly improves the accuracy and stability of measurement. The central processing part adopts 32-bit ARM embedded technology, which makes the instrument have novel interface, rich functions, clear and simple operation and stable performance. it has not only advantages of light weight, portable structure, high precision, high performance, powerful function, original interface, ease-to-use, but also work stability. It can measure U, I, P, Q, S, E, frequency, power factor, phase angle, harmonics etc. Accuracy class: 0.04.
Product Introduction Digital double clamp Phase voltammeter is a high-precision low-price hand-held double-channel input measurement instrument designed for voltage current and Phase measurement on site.Using this meter the phase between u-u i-i and u-i can be easily measured in the field the phase sequence of sensitive and capacitive circuits and three-phase voltage can be distinguished the wiring group of transformers can be detected the secondary circuit and bus differential protection system can be tested the phase relationship between CT of each differential protection group can be read out and the wiring of the electricity meter can be checked.The tongs current transformer is used to input the measured current so there is no need to disconnect the measured line.When measuring the phase between u1-u2 the two input circuits are completely insulated and isolated so it completely avoids the possible short-circuit of the measured circuit caused by wrong wiring and thus burns out the measuring instrument.The display screen USES high-contrast Liquid crystal display with words up to 25mm and The screen Angle can be freely converted to about 70�° to obtain better visual effects. Digital double clamp Phase voltammeter enclosure USES engineering insulation materials another rubber vibration protection sleeve safe and reliable. Product namesï¼?Phase meter double clamp Phase meter double clamp Phase voltammeter clamp forms a table clip-on Phase voltammeter Digital Phase double clamp Phase meter Digital double clamp table low-pressure volt-ampere Phase inspection table hand-held Digital double clamp Phase voltammeter double clamp type Digital Phase meter double clamp Digital Phase meter double clamp type volt-ampere Phase meter double clamp volt-ampere Phase table double clamp Phase meter Digital display double clamp Phase voltammeter
M-4673 mini digital leakage current clamp meter features high reliability, safety, precision and compact design with 1mA resolution. AC/DC Current range of 100A; particular VFC start mode. Entering this mode can accurately measure voltage and current which has VFC frequency conversion. Voltage or current response display is T-RMS. Whole range overload protection, reliable measurement accuracy and unique design makes it an outstanding new generation electrician/electric power measurement instrument.
GF211 double clamp phase volt-ampere meter is a multi-functional portable instrument. It can measure not only alternating voltage, but also alternating current. Its important function is to measure phase angle between two voltages, between two current or between voltage and current. The current signal is obtained by the clamp current transformer without cutting off current wire. It can discern inductive circuit and capacitive circuit; can directly read differential protection phase among every unit of CT; can check connection of transformer; measure three way voltage phase sequence; can check whether the meter connection is right or not; can evaluate the running speed of electric kWh meter. It has high resolution of current, so can be used as a leakage current meter. It is an ideal choice for electric power bureau, factories, mine, petroleum -chemistry enterprises, metallurgy factories and so on.
We are a worldwide leading manufacturer of measuring instruments. We are actively looking for distributors worldwide. Should you want to distribute the best quality products with great product availability at competitive prices, please do not hesitate to contact us.
JCD type meter box clamp is made of special aluminum alloy material, has a strong electrical conductivity. it is used for aluminum conductor, copper conductor and copper to aluminum transitional conductor. The clamp is mainly used in the connection between the bus and the meter box, one end is to be connected with the bus. Through the hinge wedge, it tightens the conductor. C-type structure of the body can always maintain a constant contact with the conductor pressure (total breathing). It can be used for aluminum to aluminum conductor, aluminum to copper conductor, copper to copper conductor connection. JCD-0main wire: 10~25Branch wire: 1.5-16 Pull force:0.8Rated Current: 80 JCD-1 main wire: 35~50 Branch wire: 1.5-16 Pull force:0.8Rated Current: 80
Jcd type meter box clamp is made of special aluminum alloy material, has a strong electrical conductivity. It is used for aluminum conductor, copper conductor and copper to aluminum transitional conductor. The clamp is mainly used in the connection between the bus and the meter box, one end is to be connected with the bus. Through the hinge wedge, it tightens the conductor. C-type structure of the body can always maintain a constant contact with the conductor pressure (total breathing). It can be used for aluminum to aluminum conductor, aluminum to copper conductor, copper to copper conductor connection. Jcd-0main wire: 10~25branch wire: 1.5-16 pull force:0.8rated current: 80 Jcd-1 main wire: 35~50 branch wire: 1.5-16 pull force:0.8rated current: 80
JCD type meter box clamp is made of special aluminum alloy material, has a strong electrical conductivity. it is used for aluminum conductor, copper conductor and copper to aluminum transitional conductor. The clamp is mainly used in the connection between the bus and the meter box, one end is to be connected with the bus. Through the hinge wedge, it tightens the conductor. C-type structure of the body can always maintain a constant contact with the conductor pressure (total breathing). It can be used for aluminum to aluminum conductor, aluminum to copper conductor, copper to copper conductor connection. JCD-WX main wire: 16~240 branch wire: 1.5-16 Pull force: 1.2 Rated Current: 270