Luminox ppm fluorescence o2 sensors features * fluorescenceâ??based optical technology * contains no hazardous materials; rohs & reach compliant * factory calibrated * high accuracy * maintenance free * long life, non-depleting technology - can be stored in any oxygen % Luminox ppm fluorescence o2 sensors benefits * low power, long life due to non-depleting sensing principle * compact footprint Luminox ppm fluorescence o2 sensors technical specifications Supply voltage (vs) : 8-30v dc Supply current (ls) :
ANALYSIS VALUES Organoleptic Bright, clear; with absence of foreign odors and flavors Peroxide index 0.1 – 1.0 (meq O2 / Kg) Free fatty acid as oleic acid 0.03 – 0.07 (g / 100g) Lovibond color Yellow 10 – 15 (in 133.35mm cell) Red 0.6 – 1.5 (in 133.35mm cell) Unsaponifiable matter Max.: 1.00 (g / 100g) Soap Max.: 10 (ppm) Winter Test Oil will remain clear after cooling it for 24hs a 0ºC Moisture and volatile matter Max.: 0.05 (g / 100g) Impurities Will not contain naked eye Insoluble impurities Max.: 0.02 (g / 100g) Specific gravity at 25ºC 0.9133 – 0.9175 Refractive index at 25ºC 1.4706 – 1.4740 Iodine index 110 – 140 (g I2 / 100g) Saponification value 188 – 192 (mg OHK / g) Halphen – Gastaldi test Negative Linolenic acid Max.: 0.3 (as fatty acid / 100g of total fatty acids)
1.General description The luminox family (lox) is a range of factory calibrated oxygen sensors which measure ambient oxygen partial pressure (ppo2) levels using the principle of fluorescence quenching by oxygen. By default luminox measures ppo2 (mbar) and temperature (°c). An optional pressure sensor enables luminox to also measure barometric pressure (mbar) and to convert the ppo2 reading to an oxygen concentration (o2%). The sensor benefits from low power operation, traditionally associated with electrochemical sensors, while providing a much longer lifetime due to the non-depleting sensing principle. Luminox is ppo2 and temperature compensated, enabling accurate operation over a wide environmental range without the need for additional system components. Unlike other sensor technologies, luminox is very stable and robust, does not contain lead or any other Hazardous materials and has negligible cross sensitivity to other gases. 2.Cleaning The housing of the sensor can be cleaned using a damp cloth. The sensor should not be immersed in any cleaning media. Full application and technical support can be provided by our knowledgable and highly experienced engineering team if required. 3.Benefits -low power -can also measure o2% & barometric pressure (lox-02) -suitable for battery power use -long life - high accuracy - small & compact - low cost -maintenance free contains no hazardous materials -connects directly to microcontroller - without any additional circuitry. - factory calibrated 4.Applications -oxygen detection -portable equipment - breathing apparatus - inerting - medical -lab equipment - agriculture -incubation -fire prevention - flue gas in condensing boilers
(LME standards) Standard Cu Cathode-1, purity 99, 97-99, 99 %Dimension: 914 mm x 914 mm x 12 mm (LME standards) Copper (Cu) min% 99.99% Other materials may be present which are described below: Oxygen O2 -- Sulfur S 4 PPM Iron Fe 2 PPM Silver(Argent 10 PPM Lead Pb 0.2 PPM Nickel Ni 0.2 PPM Selenium Se 0.3 PPM Antimony Sb 0.1 PPM Silica Si 0.3 PPM Cobalt Co 0.2 PPM Arsenic As 0.1 PPM Bismuth Bi 0.1 PPM Manganese Mn 0.1 PPM Tellurium Te 0.05 PPM Aluminum Al 0.5 PPM Magnesium Mg 0.4 PPM Zinc Zn 0.4 PPM
(LME standards) Standard Cu Cathode-1, purity 99, 97-99, 99 %Dimension: 914 mm x 914 mm x 12 mm (LME standards) Copper (Cu) min% 99.99% Other materials may be present which are described below: Oxygen O2 -- Sulfur S 4 PPM Iron Fe 2 PPM Silver(Argent 10 PPM Lead Pb 0.2 PPM Nickel Ni 0.2 PPM Selenium Se 0.3 PPM Antimony Sb 0.1 PPM Silica Si 0.3 PPM Cobalt Co 0.2 PPM Arsenic As 0.1 PPM Bismuth Bi 0.1 PPM Manganese Mn 0.1 PPM Tellurium Te 0.05 PPM Aluminum Al 0.5 PPM Magnesium Mg 0.4 PPM Zinc Zn 0.4 PPM
Granoterra Sunflower Oil: Origin, mainly from Hungary. Pet bottles, 1L, 2L, 3L, 5L. Jerry cans, 25L, Flexitanks, Flexibags (20ft Container). SPECIFICATIONS: Moisture & Volatile Matter, 0.10%; Max FFA (as Oleic Acid), 0.10%; Max Peroxide Value, 2.0 meq. O2/Kg; Max Colo� (Lovibond Cell 5 �¼â??), 10Y Max â?? 1.0R; Max Iodine Value (Wijs), 94-141; Soap, 0 ppm; Max Insoluble Impurity, 0.05%; Max Odor, Bland & Neutral when warmed. To secure the safety of the commodity during sea transportation the pure refined sunflower oil grade A, will be packed in standard
Appearance: pure, refined, without sediments and with a light yellow color Taste and odor: Deodorized with good taste Saponification index 188,0 195,0 IRAM 5516 / ISO 3657 Unsaponificable matters Max. 0,7 % ISO3596 Acidity (80% oleic) Max. 0,07 % IRAM 5512 / ISO 660 Soap (ppm oleate of sodium) Max. 7ppm IRAM 5599 Index of peroxides (meq O2/Kg) Max. 4meg/kg IRAM 5551 / ISO 3960 Color: IRAM 550 Yellow Lovibond (5) Max. 12 ISO 15305
O2-M2 Oxygen Sensor Description Alphasense Oxygen sensors use capillary flow control. Unlike partial pressure oxygen sensors, they have good pressure and temperature dependence, making them the best choice in safety applications. Standard galavanic sensors use lead for greatest reliability but fixed lifetime. Specifications * Output: 80 to 120 uA @ 20.9% O2 * Response time t90: < 15 (s) from 20.9% to 0% O2 * Linearity: 0.6 % O2 deviation @ 10% O2 * Operating life: > 24 months *Temperature range: -30 to 55 'C * Pressure range: 80 to 120 kPa * Humidity range: 5 to 95 % rh continuous * Diameter: 20.0 mm (including label) * Heigh: 17.4 mm (including foam ring) * Weight: < 16g
LOX-02-F LuminOx Flow-through Optical Oxygen Sensor General Description The LuminOx Flow-Through Optical Oxygen Sensor Allows For A Clean Gas Sample Stream Directly Into The Sensor Which Can Be Completely Removed From The Process Environment. The LuminOx Flow-through Optical Oxygen Sensor is developed and manufactured by SST, it is part of the LuminOx family, which is a range of factory calibrated oxygen sensors which measure ambient oxygen levels using the principle of fluorescence quenching by oxygen, also known as luminescence quenching. The LuminOx Flow-through Optical Oxygen Sensor (LOX-02-F) is an extension to the standard range of LuminOx oxygen sensors. The original LOX-02 sensor was designed to be completely immersed in the sample gas environment as the base of the sensor is not gas-tight. The flow-through housing style is sealed on the base which allows for a clean gas sample stream into the sensor which can be completely removed from the process environment. A flow-through housing allows for better sample gas management and options in terms of where the sensor can be situated. The patented technology allows SST to produce a range of sensors that are based on a non-depleting operating principle. This can contribute to the LuminOx sensors having a comparably longer lifetime that other competitor technologies, such as galvanic sensors, for similar applications. LOX-02-F LuminOx Flow-through Optical Oxygen Sensor Features * Luminescence-based optical technology, NOT electrochemical * Contains no hazardous materials; RoHS & REACH compliant * Connects directly to a microcontroller without any additional circuitry * Factory calibrated * High accuracy, fast response * Maintenance free LOX-02-F LuminOx Flow-through Optical Oxygen Sensor Benefits * Compact, flow-through housing with sealed base * Low power, long life due to non-depleting sensing principle * Low cos OX-02-F LuminOx Flow-through Optical Oxygen Sensor Technical Specifications *â?¢ Supply voltage: 4.5 - 5.5V DC * Supply current:
Zirconia o2 sensors Miniature series The miniature zirconium dioxide oxygen sensors can be pcb mounted and are used when measuring ambient gas with the complete sensor immersed in the atmosphere which is to be measured. Features * zirconium dioxide (zro2 ) sensing elements * long life, non-depleting technology * integral heating element * high accuracy * requires an external interface board to operate Benefits * no reference gas required * no need for temperature stabilisation * pcb mountable Technical specifications Heater voltage Standard response sensor: 4v dc â± 0.1v dc (1.7a) Standby: 1.65v dc (0.7a) Fast response sensor: 4.35v dc â± 0.1v dc (1.85a) Standby: 2v dc (0.85a) Pump impedance at 700'c: < 6k Permissible gas temperature: -100'c to +250'c Gas flow rate : 0 - 10 m/s Repetitive permissible acceleration: 5g Incidental permissible acceleration: 30g Output values Oxygen pressure range: 2mbar - 3bar max Accuracy: 5mbar max Internal operational temperature: 700'c Response time (10 - 90% step) Standard response sensor:
The luminox family is a range of factory calibrated optical sensors which measure ambient o2 levels using the principle of fluorescence quenching by oxygen. Our unique patented process allows us to produce an oxygen sensor that benefits from low power, traditionally associated with electrochemical sensing devices, while providing a much longer lifetime due to the non-depleting sensing principle. * low drift * rohs compliant * extended temperature range compared to electrochemical sensing devices * low in cost * factory calibrated * measures temperature and pressure (if selected) * small and compact * maintenance free Luminox unlike other sensor technologies is stable and robust, it is rohs compliant as it does not contain lead or any other hazardous materials and has negligible cross sensitivity. Luminox can be purchased as a single optical sensor, or as part as an evaluation kit which includes the luminox sensor evaluation interface board, which was designed to allow customers to easily evaluate the sensor with minimum effort or design work. Typical applications for the luminox optical oxygen sensor are; * oxygen detection * portable equipment * breathing apparatus * inerting * medical * lab equipment * agriculture * incubation * fore prevention * flue gas in condensing boilers Part numbering system Lox - xx 01: measures 0-300 mbar ppo 2 and temperature (â°c) 02: measures 0-300 mbar ppo 2 , 0-25% o 2 , temperature (â°c) and 500-1200mbar barometric pressure -
LOX-02-S LuminOx Sealed Optical Oxygen Sensor General Description The LuminOx Sealed Optical Oxygen Sensor Range Offers Users With Application Requirements To Only Measure Sample Gas At The Front Face Of The Sensor. The LuminOx Sealed Optical Oxygen Sensor is developed and manufactured by SST, it is part of the LuminOx family, which is a range of factory calibrated oxygen sensors which measure ambient oxygen levels using the principle of luminescence quenching. The LuminOx Sealed Optical Oxygen Sensor (LOX-02-S) is an extension to the standard range of LuminOx oxygen sensors. It is a similar diffusion type sensor like the original LOX-02 sensor. However, the LOX-02-S has a sealed base that is gas-tight, meaning only the face of the sensor with the protective membrane needs to be in the sample gas environment, externally leaving easy access to the pins of the sensor. LOX-02-S LuminOx Sealed Optical Oxygen Sensor Features * Luminescence-based optical technology, NOT electrochemical * Contains no hazardous materials; RoHS & REACH compliant * Connects directly to a microcontroller without any additional circuitry * Factory calibrated * High accuracy * Maintenance free LOX-02-S LuminOx Sealed Optical Oxygen Sensor Benefits * Compact, diffusion-type housing with sealed base * Low power, long life due to non-depleting sensing principle * Low cost LOX-02-S LuminOx Sealed Optical Oxygen Sensor Technical Specifications * Oxygen range: 0 - 25% O2 * Oxygen pressure range: 0 - 300mbar ppO2 * Response time: T90 < 30s (typical) * Supply voltage: 4.5 - 5.5V DC * Supply current:
Features * oxygen pressure range 2 mbar - 3bar * zirconium dioxide (zro2 ) sensing elements * non-consumption technology * integral heating element * no need for temperature stabilisation * no reference gas required * high accuracy * linear output signal * operates with external interface boards Specifications Heater voltage: Porous cap (15mm): 4.35v dc +/- 0.1v dc (1.85a) Stand by: 2v dc (0.85a) Pump resistance @ 700'C: < 6kOhm Permissible gas temperature: -100 to 250C Gas flow rate: 0 to 10 m/s Repetitive permissible acceleration: 5 g Incidental permissible acceleration: 30 g
O2-a2 oxygen sensor Performance Output î¼a @ 20.9% o2 80 to 120 Response time t90 (s) from 20.9% to 0% o2 < 15 Zero current î¼a in n2 < 2.5 Linearity % o2 deviation @ 10% o2 0.6 Lifetime Output drift % change in output @ 3 months < 1 Operating life months until 85% original output of 20.9% o2 > 24 Environmental Humidity sensitivity % o2 change: 0% to 95% rh @ 40â?? < 0.7 Co sensitivity % (change o2 reading) / % co2 @ 5% co2 0.1 Pressure sensitivity (% change of output)/(% change of pressure) @ 20kpa < 0.1 Key specifications Temperature range â?? -30 to 55 Pressure range kpa 80 to 120 Humidity range % rh non-condensing (0 to 99% rh short term) 5 to 95 Storage period months @ 3 to 20â?? (store in sealed pot, open circuit) 6 Load resistor î© (recommended) 47 to 100 Diameter mm (including label) 20.0 Height mm (including foam ring) 17.4 Weight g < 16 -
Zirconia o2 sensors Probe series - long housing Features * zirconium dioxide (zro2) sensing elements * long life, non-depleting technology * integral heating element * high accuracy * requires an external interface board to operate Benefits * no reference gas required * no need for temperature stabilisation * two lengths available; 220mm and 400mm Technical specifications Heater voltage Operating: 4v dc ± 0.1v dc (1.7a) Standby: 1.65v dc (0.7a) Pump impedance at 700'c: < 6k Permissible gas temperature Standard temperature: -100'c to +250'c High temperature: -100'c to +400'c Gas flow rate: 0 - 10 m/s Repetitive permissible acceleration: 5g Incidental permissible acceleration: 30g Output values Oxygen pressure range: 2mbar - 3bar max Accuracy: 5 mbar max Internal operational temperature: 700'c Response time (10 - 90% step): < 15s Warm up time (prior to sensor operation): 100s Warm up time (from stand by): 20s Output stabilisation time: ~ 180s
Zirconia o2 sensors Flange mounted series The flange mount zirconium dioxide oxygen sensor is designed for easy sealing into a manifold or sampling chamber. Favoured by ssts aerospace customers and in applications that require high temperature and pressure operation. O2s-fr-t4-4p flange zirconia o2 sensors features Zirconium dioxide (zro2) sensing elements Long life, non-depleting technology Integral heating element High accuracy Requires an external interface board to operate O2s-fr-t4-4p flange zirconia o2 sensors benefits No reference gas required No need for temperature stabilisation Flange mounting O2s-fr-t4-4p flange zirconia o2 sensors technical specifications Heater voltage Operating: 4.35vdc ± 0.1vdc (1.85a) Standby: 2vdc (0.85a) Pump impedance at 700'c: < 6k Permissible gas temperature: -100'c to +400'c Gas flow rate: 0 - 10 m/s Repetitive permissible acceleration : 5g Incidental permissible acceleration: 30g O2s-fr-t4-4p flange zirconia o2 sensors output values Oxygen pressure range: 2mbar - 3bar max Accuracy: 5mbar max Internal operational temp: 700'c Response time (10 - 90% step): < 4s Warm up time (prior to sensor operation): 60s Warm up time (from standby): 20s Output stabilisation time: ~ 180s
Zirconia O2 Sensors Probe Series - Short Housing The Probe Range of zirconium dioxide oxygen sensors are available in three lengths. Suitable for aggressive and polluted applications such as boiler exhausts. Longer probes are an ideal solution for thicker walled, insulated flue pipes. FEATURES * Zirconium dioxide (ZrO2) sensing elements * Long life, non-depleting technology * Integral heating element * High accuracy * Requires an external interface board to operate BENEFITS * No reference gas required * No need for temperature stabilisation * Compact enclosure TECHNICAL SPECIFICATIONS Heater voltage Operating (standard response) 4V DC ± 0.1V DC (1.7A) Standby 1.65V DC (0.7A) Operating (fast response) 4.35V DC ± 0.1V DC (1.85A) Standby 2V DC (0.85A) Pump impedance at 700'C < 6kΩ Permissible gas temperature -100'C to +250'C Gas flow rate 0 ~ 10 m/s Repetitive permissible acceleration 5g Incidental permissible acceleration 30g OUTPUT VALUES Oxygen pressure range 2mbar ~ 3bar max Accuracy 5mbar max Internal operational temperature 700'C Response time (10 - 90% step) Standard response sensor < 15s Fast response sensor < 4s Warm up time (prior to sensor operation) 60s Warm up time (from standby) 20s Output stabilisation time ~ 180s
Zirconia O2 Sensors Probe Series - Long Housing FEATURES * Zirconium dioxide (ZrO2) sensing elements * Long life, non-depleting technology * Integral heating element * High accuracy * Requires an external interface board to operate BENEFITS * No reference gas required * No need for temperature stabilisation * Two lengths available; 220mm and 400mm TECHNICAL SPECIFICATIONS Heater voltage Operating 4V DC ± 0.1V DC (1.7A) Standby 1.65V DC (0.7A) Pump impedance at 700'C < 6kohm Permissible gas temperature Standard temperature -100'C to +250'C High temperature -100'C to +400'C Gas flow rate 0 - 10 m/s Repetitive permissible acceleration 5g Incidental permissible acceleration 30g OUTPUT VALUES Oxygen pressure range 2mbar - 3bar max Accuracy 5 mbar max Internal operational temperature 700'C Response time (10 - 90% step) < 15s Warm up time (prior to sensor operation) 100s Warm up time (from stand by) 20s Output stabilisation time ~ 180s
FEATURES * Oxygen pressure range 2 mbar - 3bar * Zirconium dioxide (ZrO2 ) sensing elements * Non-consumption technology * Integral heating element * No need for temperature stabilisation * No reference gas required * High accuracy * Linear output signal * Operates with external interface boards SPECIFICATIONS Heater Voltage Porous Cap (15mm) 4.35V DC ± 0.1V DC (1.85A) Stand by 2V DC (0.85A) Pump resistance @ 700'C < 6k� Permissible gas temperature -100 to 250'C Gas flow rate 0 to 10 m/s Repetitive permissible acceleration 5 g Incidental permissible acceleration 30 g z
Oxygen sensor o2 gas sensor for portable gas detector Model number: o2-a2 Performance Output µa @ 20.9% o2 80 to 120 Response time t90 (s) from 20.9% to 0% o2 < 15 Zero current µa in n2 < 2.5 Linearity % o2 deviation @ 10% o2 0.6 Lifetime Output drift % change in output @ 3 months < 1 Operating life months until 85% original output of 20.9% o2 > 24 Environmental Humidity sensitivity % o2 change: 0% to 95% rh @ 40°c < 0.7 Co2 sensitivity % (change o2 reading) / % co2 @ 5% co2 0.1 Pressure sensitivity (% change of output)/(% change of pressure) @ 20kpa < 0.1 Key specifications Temperature range °c -30 to 55 Pressure range kpa 80 to 120 Humidity range % rh continuous (0 to 99% rh short term) 5 to 95 Storage period months @ 3 to 20°c (store in sealed pot, open circuit) 6 Load resistor o (recommended) 47 to 100 Diameter mm (including label) 20.0 Height mm (including foam ring) 17.4 Weight g < 16