level measure Ultrasonic rangefinder measures range: 0.6-15m Bubble level for horizontal checkout Angle measurement Adjustable built-in laser available in spot & line shape. Conversion unit among feet, inches and meter Length /area / volume measurement Data computation , storage, recall Automatically power off after 30 seconds of inactivity. Double shell blister card /piece.
Level measurement
Features and benefits Range up to 8m/12m 6 mm range accuracy Easy remote operation, diagnosis and adjustment with KEY/LCD or PC Low processing power Capable 2-wire, loop powered, intrinsically safe inner temperature compensation to ensure accuracy of measurement Non-contact measurement Easy mounting via 1¿÷ NPT Low cost Application Continuous, non-contact level measurement in fluids, pastes, sullies and coarse bulk materials Characteristics Measuring Range Solids applications: 4m/6m (transducer dependent) Liquid applications: 8m/10m (transducer dependent) Measuring Resolution 2mm Accuracy 0.25% of range or 6mm, whichever is greater Max. Pulse Frequency 43.5KHz Operating Temperature -20..+80í+ Operating Pressure 0.7..3 mbar Power Supply 15..30V Power Consumption 51 mW ... 800 mW PCB Size Driver board(Ñ+:84mm), Main CTL board(Ñ+:80mm) PCB Material FR4 LCD Size 128*64dot Description ANL-4012 Ultrasonic Level Measurement Instruments use sound waves to determine level. A piezoelectric crystal inside the transducer mounted on top of the tank converts electrical pulses into sound energy that travels in the form of a wave at the established frequency and at a constant speed in a given medium. The sound waves are emitted in bursts and received back at the transducer as echoes. The Ultrasonic Level Measurement Instrument measures the time for the bursts to travel down to the reflecting surface and return. This time will be proportional to the distance from the transducer to the surface and can be used to determine the level in the tank. Ultrasonic systems are accurate within a range of approximately 8m. A typical installation consists of two parts: A Transducer, consisting of both a transmitter and receiver. Ultrasonic energy is transmitted from the í¦headí¦ in the direction of the liquid surface. When the ultrasonic waves contact the surface, they are reflected back to the receiver in the head. Electronics, which produce, control and time the ultrasonic pulses which are transmitted and received by the head. The electronics also transmit control signals to remote monitoring devices such as displays and process control systems.
MLC-V235 Continuous Casting Mold Level Automatic Measurement System Overview The automatic control for the molten steel level of the mold is one of the key technologies of continuous casting production. It is very important to reduce the labor intensity of workers, improve production efficiency, improve the quality and output of casting billet, reduce overflow and breakout of steel and improve the management level of steelmaking and continuous casting. The molten steel is poured into the mold. In order to prevent overflow, the molten steel level must be kept stable. Otherwise, during the casting process, if the level will fluctuate too much, and slag will be involved, forming surface slag inclusion on the surface of the casting billet, affecting the quality of the billet. The test points out that the relationship between the level fluctuation and the depth of casting billet surface slag inclusion is as follows: The experience has shown that surface slag inclusions can be eliminated when the level fluctuation is within 10mm. At the same time, if the level fluctuation is more than 10mm, the rate of longitudinal cracks on the casting billet surface is 30%. It means that the level fluctuation directly affects the surface quality of the casting billet. The principle of the system The eddy current type molten steel level gauge is the key to the system. The system operates reliably and has excellent performance: high temperature resistance, strong anti-interference ability, fast dynamic response (lag time
Aluminium level Topredo level Plastic calipers Adjustable square Zinc-alloy steel angle square Oil filter wrench
Explosion proof typed tuning fork level switch, d ii ct6 Fundamental principles The su-yc vibrating probe level switch/liquid level control switch is a kind of universal liquid level switch, which is brought to its resonance frequency by means of piezoelectric crystals drive. If the tuning fork is covered by liquid or solidity, this frequency will change. The electronics of the su-yc monitor the resonance frequency and then output a switching value, in this way, to alarm and control the liquid level. The structure and characteristics of tuning fork liquid level switch make it can replace any level switch of other principles, and can be widely used in building materials, petroleum, chemical industry, light industry, metallurgy field to alarm or control the height of liquid level for their lower and upper limit. Qualification Power supply: ac 110v/ac 220v 50hz / dc 24v Operating temperature: fork: -30-150¡ãc Instrument:-30-70¡ãc Operating pressure: ¡ü2mpa Fluid density: 0.6g/cm3 (in minimum) Action point: vertically insert into water about 25mm Start up time: about 3 sec Response time: about 1 sec Output style: one or two sets of relay contact (ac 220v/3a, dc 30v/ 3a) Output delay time: 1-20sec, can be adjusted Sensitivity: 10 grades can be set Consumption: ¡ü1w Process connection: r 1 taper pipe thread or others. Explosion proof: exd ii ct6 Exia ii bt4 Standard export packing.
Agecho ultrasonic sensors salient features: Agecho ultrasonic sensors are available with output options such as analog current 4-20ma, analogue voltage 0-5v, on/off signal, trigger output for multi-sensor application, pulse width , serial ttl , serial rs 232c. Agecho is very useful non-contact type of sensing or presence or counting of object. On/off type signal is also available. Agecho sensing range: 200mm to 1000mm … up to … 6000mm. (19.7feet) (0-200mm is dead band). Agecho accuracy is 1% of the full scale. Agecho operating voltage 12v dc, with reverse polarity protection.(24v dc optional) Agecho is self-calibrated. Microcontroller is present in each sensor. This provides direct distance/depth reading with better calibration and communication with the controller module. Agecho is very easy to install, rugged design for use in dusty and humid conditions, suitable for outdoor as well as indoor use. Agecho very useful for non-contact distance/level measurement. The distance of the target is measured, not just its presence, but gives directly 4-20ma, serial or pulse width data proportional to the distance of the target. Agecho operating temperature 0 to 65 degree celsius. Agecho temperature compensated measurement for better accuracy (optional). Agecho unaffected by ambient light, object color or any other optical characteristic. Works with hard materials like metal sheet, plywood, or soft materials like cloth and paper, rubber etc.
Measurement Ultrasonic non-contacting Accuracy 0.2% of F.S Resolution 1mm Damping Rate 0.1m/min - 100m/min adjustable Output Display Illuminated Graphic LCD IP Rating IP65 Material Polycarbonate Dimension 166(W)¡¿250(H)x95(D) mm Weight ca. 2kg Range LXD-10: 0.3~ 5m (0.98- 16.4ft) LXD-10: 0.3~10m (0.98- 32.8ft) LXD-15: 0.3~15m (0.98- 49.2ft) Process Connection 1¡± PF Weight 1.5kg - 2.0kg Material PP, PVDF Temperature Compensation by a built-in temperature sensor IP Rating IP68 Cable 2 Core Shield (AWG18) Cable Extension up to 450m (1,476ft)
•agecho ultrasonic sensors are available with output options such as analog current 4-20ma, analogue voltage 0-5v, on/off signal, trigger output for multi-sensor application, pulse width , serial ttl , serial rs 232c. •agecho is very useful non-contact type of sensing or presence or counting of object. On/off type signal is also available. •agecho sensing range: 200mm to 1000mm … up to … 6000mm. (19.7feet) (0-200mm is dead band). •agecho accuracy is 1% of the full scale. •agecho operating voltage 12v dc, with reverse polarity protection.(24v dc optional) •agecho is self-calibrated. Microcontroller is present in each sensor. This provides direct distance/depth reading with better calibration and communication with the controller module. •agecho is very easy to install, rugged design for use in dusty and humid conditions, suitable for outdoor as well as indoor use. •agecho very useful for non-contact distance/level measurement. The distance of the target is measured, not just its presence, but gives directly 4-20ma, serial or pulse width data proportional to the distance of the target. •agecho operating temperature 0 to 65 degree celsius. •agecho temperature compensated measurement for better accuracy (optional). •agecho unaffected by ambient light, object color or any other optical characteristic. Works with hard materials like metal sheet, plywood, or soft materials like cloth and paper, rubber etc.
Analytical Balance 0.1mg Precision Electro Magnetic Force Compensation, Multiple Weighing Units, Density Determination Function, Counting Weighing Mode, Underhook Weighing & TARE. Technical Specifications Model Number MAB201 Calibration Internal Display LCD Capacity 220 g Pan Size 90mm(phi) Readability 0.0001 g (0.1 mg) Response Time 4-5sec Voltage 220V AC Repeatability 0.0001 g (+-) Linearity 0.0003g(+-) Tare Range Full Frequency Hz 50-60Hz Min Capacity 0.01g
Level Indicator, Magnetic level gauges are used to measure the level of the fluid in tank systems. Level indicators can also adjustable to building management system(BMS) and by giving direct output 0-10 VDC or 4-20mA. Standard, scale, top mounted or valve connection types are also available.
Description 3-beam self-leveling laser Applications Framing rooms Rugged, impact absorbing work site "armor" Carrying case included Tripod ready Specifications Accuracy: 0.0003"/" (0.3mm/m) Laser range: up to 100' (30m) Laser class: ii Carton
Industrial weighing scale, frls panel, plc hmi, Diesel Diesel Generator Set, Compression Force Transducer, Tension/Compression Force Transducer, Bending/Shear Beams, Load Pins .
Liquid level measurement series and magnetic field measurement series.
Surgical Gown LEVEL 2-LEVEL 4Blue AMMI Level 2-3 Gown Disposable Medical PP Non-woven Gown SURGICAL GOWNS � Surgical gowns are personal protective equipment used by many people in health care. Surgical gowns are used by surgeons and the surgical team for all types of procedures. Modern surgical gowns provide a breathable, protective barrier for the surgeons and all health care providers. � Surgical gowns provide a barrier protection to prevent blood strikethrough and fluid contamination. Most surgical gowns are sterile and come in a wide variety of sizes and versions. Surgical gowns can be purchased alone or within surgical packs. There are many surgical packs for frequently performed procedures. � Surgical gowns are produced non-reinforced or reinforced. Non-reinforced surgical gowns are less durable and designed for surgical procedures with low to moderate fluid contact. Reinforced surgical gowns have reinforced protection in specific critical areas for more invasive and intense surgical procedures. Surgical gowns cover and provide a barrier for important areas from the shoulders to the knees and wrists. Surgical gowns are usually made with Set-In sleeves or Raglan Sleeves. Surgical gowns come with and without a towel. Most surgical gowns are made from a fabric called SMS. SMS stands for Spunbond Meltblown Spunbond. SMS is a lightweight and comfortable non-woven fabric that provides a protective barrier. Surgical gowns are usually rated by their AAMI level. AAMI is the Association of the Advancement of Medical Instrumentation. AAMI was formed in 1967 and they are a primary source of many medical standards. AAMI has four protection levels for surgical gowns, surgical masks, and other protective medical equipment. Level 1: is used for Minimal Risk of exposure situations, such as providing basic care and cover gowns for visitors. Level 2: is used for Low Risk of exposure situations, such as during common blood drawing procedures and suturing. Level 3: is used for Moderate Risk of exposure situations, such as surgical procedures and inserting an Intravenous (IV) line. Level 4: is used for High Risk of exposure situations, such as during long, fluid intense surgical procedures.
* Liquid level sensor * Range: 0-0.1m &0-200m * Input/Output: 10-30VDC/4-20mA, 1-5V, 0-5V; 5V/0.5-4.5V * Certification: SGS & ISO9001 1. Application Level of Lubricant and hydraulic oil for machineries Water tanks and level measurement and controls in industries area Tank level of shipment Swage treatment Irrigation and hydraulic monitoring HAVC 2. Features High sensitivity, good long term stability Strong reliability Water-proof, dust-proof Varies construction and installation methods EMI/RFI Special condensation design High strength stainless steel construction. Shocking proof packing.
MR-ELL- SA External level switch is a non-contact level switch by using the Variable frequency ultrasonic technology, it is widely applied to all kinds of liquid level detection. The measuring probe is installed on the external wall of the container. And it belongs to a completely non-contact instrument which measure the level from outside of tank.