This Range Includes Ceiling Suspended Laminar Air Flow, Movable Laminar Air Flow Supplier, Vertical Laminar Air Flow And Horizontal Laminar Air Flow. Moreover, Our Laminar Air Flow Is Extremely Demanded By The National As Well International Shoppers, As A Result Of Their Unique Options And Efficiency.
Laminar air flow information We have CE,ROHS,ISO9001,ISO14001 for it. KLC series mini-type air flow laminar box, It is used for the partical high clean requirement in workshop and lab. Characteristic 1).It is adopted the super thin air filter without clapboard to minimize the size of structure. The air flow laminar box is matched stainless steel table-board and glass on sides. 2). It makes the workaround roomy and bright. We adopt send-off wind system that the air velocity is adjustable by touch the switch lightly,which makes the wind speed perfect. 3).The pre - filter that with big wind speed is convenient to take town. It is not only protect the HEPA filter ' s life and also ensure the wind velocity. 4).Level air current, opened desk type, and convenient operation. 5) Customized design is available for laminar air flow. Packing is plywood.
Bgm laminar air flow ensure 100% sterilization of air in ot/icu/nicu/opd and burn & maternity wards. These contain pre-filters, esp, uv, charcoal & hepa filters and air chargers. It also enriches air with oxygen & negative ions and makes it pleasant atmosphere by removing bad-odour from it. No recurring cost, no chemicals & no hazards are found in bgm air sterilisers. These can run 24x7 online.Bgm air sterilizer removes all the limitation and bearers of the existing system. It is particularly very helpful for critical care centers, as this place cannot be sterilized using conventional techniques. Icus are the most infestations place in the hospitals. Doctors and nurses are always at a sorbs moisture reducing the amount of fungus. It also removes foul smell, bad-odour from the air, making a pleasant atmosphere. 5. Hepa or high efficiency particulate arrestance filter: this is a 0.3-micron filter. It is very efficient filter in trapping smallest of microorganisms. There are no microorganisms smaller than 0.5-micron size. Bgm air steriliser thus ensures 100% sterilization of air. It also enriches air with oxygen and makes it pleasant by removing bad-odour from it. Air sterilisers, ozonisers, air curtain, laminar air flow, hepa filter, hospital equipments, operation theator steriliser, i c u sterilisers, air purifiers. One unit with all accessories.
Features :- Wooden/m.S duley power coated /stainless steel body. Hepa filter Pre-filter Blower (motor blower assembly) U.V. Light Fluorescent lamp Operating switch Pressure gauge (manometer) Stainless steel table High quality hepa filter provides protection for the product (filtration efficiency of more than 99.97% at 0.3 micron. Ultra-quiet noise level of not more than 65 dba. Durable and easy to clean stainless steel work. Cock for gase or vacuum line. Work area properly illuminated by diffused glare free fluorescent light. Optional accessories :- Particle dust count-validation at site. Timer for u.V. Lights. Speed regulator Caster wheels. Magnahelic manometer. Specifications:- Standard size (working area) 2' x 2', 3' x 2', 4' x 2', 6' x 2', 8' x 2' Air velocity 90 ± 20 cfm (average) Filtration elements Main filters : hepa filter Prefilter: washable non-woven polyester fibers. Filter efficiency Main filters : 99.97 at 0.3 micron Prefilter: arrestance 90%, at 10 microns Work Stainless steel Noise level< 65 dba Light intensity800-1000 lux Power supply220v single phase, 50 hz. Wooden packing
Construction- Outer Wall Mild Steel and Inner Stainless Steel or Fully Stainless Steel. Hepa Filter Size- 610/915/1220/1830 x 610 x 75 (0.3 Micron) Pre Filter- 500/600/800 x 400 x 50 mm (10 Micron) Door- 5 mm Acrylic Foldable/Sliding Door Illumination- 20/40 W LED Light- 1 No UV Lamb- 15/30 W- 1 No Power Socket- Yes- 1/2 No (230 V/5A) Pressure Gauge- Yes Power- Single Phase 230V/50 Hz Noise Level- 70 db +/- 5 db
Our VERTICAL Laminar air flows are designed so as to meet the requirements of US Federal Standard 209 B (BS 5295) providing particle free air to meet Class 100 (Class conditions). The cabinets are fabricated out of thick board duly sun mica clad/ stainless steel/ Mild steel sheet. Interior surfaces are epoxy painted for its longer life. The worktable is made of stainless steel sheet and side panels are made out of thick transparent Plexiglas duly framed. The unit is fitted with pre-filter and is made to pass through highly effective HEPA (High Efficiency Particulate Air) filters having efficiency rating as high as 99.99% with cold DOP and 99.97% with hot DOP, thus retaining all airborne particles of size 0.3 micron and larger. Using a dynamic machine, the blower and motor assembly is statically and dynamically balanced ISI marked motor of 1/5 H.P. capacity operates with minimum noise level. The working area is illuminated by fluorescent lights fitted to the unit. Height of the working table provides comfortable "SIT DOWN" working position for the operator. Supplied complete with manometer, UV light fluorescent light.
MOBILE LAMINAR AIR FLOW - Mobile Laminar Air Flow units offers highest product protection by providing ISO Class 5 particle free work area suitable for handling critical materials and processes. The work area is continuously supplied with positive pressure HEPA filtered vertical air flow. A continuous unidirectional vertical air flow prevents contamination from operator and the environment.
REVERSE LAMINAR AIR FLOW - Reverse Laminar Airflow Booths (aka Powder Containment Booths) are primarily designed to control the hazardous emissions of dust clouds during powder weighing, charging, sampling and dispensing operations. These booths provide highest level of protection to the operator and the environment from airborne contaminants generated during such powder handling operations and also protects the product from ambient air contamination.
GARMENT CABINET - Sterile Garment Cabinets are designed to provide ISO Class 5 (Class 100) particle free storage area for garments and to avoid any particulate accumulation. The storage area is continuously supplied with positive pressure HEPA filtered re-circulated vertical air flow for maintaining the class integrity of the storage area.
HORIZONTAL LAMINAR AIR FLOW - Horizontal Laminar Airflow (LAF) Benches are designed for offering highest product protection by providing ISO Class 5 particle free work area suitable for handling critical materials and processes. The work area is continuously supplied with positive pressure HEPA filtered horizontal air flow. A continuous unidirectional horizontal air flow prevents contamination from operator and the environment.
TEMPO make laminar airflow cabinets are a series of high efficiency clean room workbenches designed to protect equipment and other contents of the work zone from particulates. In a vertical laminar airflow cabinet, filtered air blows on the work zone and leaves through the holes in the base of three sides SS 304 covered sheet. As compared to horizontal type, vertical flow cabinet can provide greater operator protection. Application Plant tissue culture Media plate preparation Electronic inspection Media device assembly Pharmacy drug preparation General lab work Semiconductor industry Aeronautics industry
Application area; especially operating theatres, pharmaceutical industry, chemical industry, food production, electronic industry and research laboratories. Sensitive applications in aforementioned application areas require a ventilation system suitable for conditions specified in standards.Gonka laminar flow extract systems reduce microorganism contaminants and particulate concentrations in air to the minimum level in accordance with the standards. Hepa filters which clean filtrated air before going into operating room. Mounting situated in ceiling of the operating theatre in such a way that it should locate over operating table. Stainless steel air distribution box, hepa filters, transparent air distributor (laminarizator) and pendant operating table lighting connection. Easy maintenance and disinfection because of transparent air distributor's being pulled down. Operating theatre lighting system made up of airproof construction. A laminar, vertical air flow from transparent air distributor through operating table prevents turbulent air flow in conventional air systems and offers a high level cleanliness class around the operating table during the operati The system which remove particulates and microbes from operation part due to laminar flow. Special design for operation theatres which require especially high level sterilization in accordance with din 1946. Differential pressure sensors. Easy connection differential pressure sensors and leakage testing. Easy installation to all kinds of ceilings. Depends model
Laminar flow cabinet information The laminar flow cabinet can be made of stainless steel 304 or cold rolled steel. Klc series mini-type air flow laminar box, it is used for the partical high clean requirement in workshop and lab. Characteristic 1).It is adopted the super thin air filter without clapboard to minimize the size of structure. The Air flow laminar box is matched stainless steel table-board and glass on sides. 2). It makes the workaround roomy and bright. We adopt send-off wind system that the air velocity is adjustable by touch the switch lightly, which makes the wind speed perfect. 3).The pre - filter that with big wind speed is convenient to take town. It is not only protect the hepa filter ' s life and also ensure the wind velocity. 4).Level air current, opened desk type, and convenient operation. 5) customized design is available. Packing is plywood.The customer design is available.
Laminar Flow Hood Air Flow LP22R-ULPA LM air technology Laminar Flow Hood Air Flow LP22R-ULPA LM air technology USA Seems never used. AS IS sale
Melt Flow Index Tester indicates the uniformity of the flow rate of the polymer. This instrument measures the rate of extrusion of Molten resins through a drill of specified Length and diameter under prescribed conditions of temperature, load, and piston position. This test method covers measurement of rate of extrusion of molten resins through a die having bore diameter of 2.095 mm and a specified length of 8 mm within a stipulated time. Accordingly the unit of MFI is reported in grams/10 minutes. There are different test conditions based on the standard chart for Temperature Vs Fixed load for checking such melt index. Additionally two more tests could be incorporated in this same melt indexer such as MVR (melt volume-flow rate) and melt density for thermoplastics. We offer various different models seen below depending on technical features and operations comfort of the user.
BIOSAFFETY CABINETS - Biosafety Cabinet (aka biological safety cabinet or microbiological safety cabinet) is an enclosed, ventilated laboratory workspace for safely working with materials contaminated with (or potentially contaminated with) pathogens requiring a defined Bio-Safety Level (BSL). The primary purpose of a Bio-Safety Cabinet is to serve as the primary means of protection for the laboratory worker and the surrounding environment from pathogens.
DYNAMIC PASS BOXES - Dynamic Pass Box (aka Pass Through Box or Clean Pass Box) is primarily designed to minimize man and material movement between different classified areas thereby minimizing the chances of cross contamination. Pass Box is an essential equipment for any manufacturing or research facility which requires maintaining the integrity of different classified areas.
FUME HOOD - Fume Hoods (aka Fume Exhaust Hood) are designed to exhaust and contain toxic, obnoxious or otherwise harmful gases, vapors, mist etc. to protect laboratory workers and equipment. A motor driven blower creates negative pressure within the work area, extracting the contaminated air from work area and expel it into the atmosphere. The Hood is ventilated of the air drawn from inside the laboratory which is used effectively for thorough sweep-out of work area.
Laminar air flow equipment.