Performance Sensitivity na/ppm at 2ppm co 420 to 650 Response time t90 (s) from zero to 10ppm co < 25 Zero current na in zero air at 20°c +30 to -130 Noise* ±2 standard deviations (ppb equivalent) 4 Range ppm limit of performance warranty 1000 Linearity ppb co error at full scale, linear at zero, 500ppm co 20 to 35 Overgas limit maximum ppm for stable response to gas pulse 2000 * tested with alphasense isb low noise circuit Environmental Sensitivity @ -20°c (% output @ -20°c/output @ 20°c) @ 5ppm co 40 to 70 Sensitivity @ 50°c (% output @ 50°c/output @ 20°c) @ 5ppm co 110 to 125 Zero @ -20°c na -30 to +30 Zero @ 50°c na -50 to -200 Cross sensitivity Filter capacity ppm·hrs h2s 250, 000 H2s sensitivity % measured gas @ 5ppm h2s < 1 No2 sensitivity % measured gas @ 5ppm no2 < 1 Cl2 sensitivity % measured gas @ 5ppm cl2 < 1 No sensitivity % measured gas @ 5ppm no < -3 So2 sensitivity % measured gas @ 5ppm so2 < 0.1 H2 sensitivity % measured gas @ 100ppm h2 at 20oc < 10 C2h4 sensitivity % measured gas @ 100ppm c2h4 < 1 Nh3 sensitivity % measured gas @ 20ppm nh3 < 0.1 Key temperature range °c -30 to 50 Specifications Pressure range kpa 80 to 120 Humidity range % rh continuous 15 to 90 Storage period months @ 3 to 20°c (stored in sealed pot) 6 Load resistor o (isb circuit is recommended) 33 to 100 Weight g < 13 Isweek provide smoke, gas, humidity&temperature, uv, fluid or other kinds of sensors More details welcome to inquiry: skype:isweek_laura
Misir is a low power (20mw4), high performance co2 sensor. Based on gss patented solid state ir sensor technology and innovative optical designs, misir is configured to meet the requirements of the hvac and demand led ventilation markets. Low power 20mw Measurement ranges from 0 to 1% Low noise measurement
Items Technical parameter Detection Range a1000ppm Max detecting bound 2000ppm Detecting life 5 years Sensitivity 0.015 Resolution 0.5ppm Temperature range Pressure range Normal atmosphere Response time(T90)
Gas leak detection in stationary fuel cells combustible gas sensor module Model number:cgm6812--b00 Features: * linear analog output proportional to gas Concentration * maintenance free * compact size * meets rohs requirements Applications: * gas leak detection in fuel cell systems * hydrogen & combustible gas leak Detectors Description: The cgm6812-b00 combustible gas sensor module is A new unit which utilizes tgs6812, figaro's catalytic Pellistor type gas sensor which features durability and stability. This module provides analog output voltage proportional to hydrogen gas concentration. Cgm6812-b00 has conformal coatings for moisture- Proofing and electrical insulation purposes, and is also Capable of detecting sensor wire breakage. The unit has A wide range of operating temperature from -10' to +60'c. Because the tgs6812 sensor can detect methane and lp gas As well as hydrogen, this module is suitable for gas Leak detection in stationary fuel cells which use hydrogen Generated from combustible gases Sensor Module Cgm6812
NAP-66A is mainly used for gas detectors and leak testers. NAP-66A is a half in height and needs a half in power consumption compared to existing sensor so that thinner and lighter-weight detectors can be produced. The following are the basic characteristics but it is recommended to refer to the individual users manual for further information. * Target gases and concentration Propan(C3H8): 0.03~ 2.2% (0.03~ 1%) Iso-butane(Iso-C4H10): 0.03~ 1.8% (0.03~ 0.8%) Hydrogen(H2):0.05~ 4% (0.05~ 1.5%) Ethanol(C2H5OH): 0.05~ 3.2% (0.05~ 1.5%) Hydrocarbons(CnH2n+2): 1~100% LEL (1~50%LEL) ( ) is a detection range in high accuracy * Ratings Supply Voltage: DC 2.0 ± 0.2V AC 2.0 ± 0.2V (r.m.s. 50~60Hz) Current (When 2.0V is applied): DC 140 ~ 160mA AC 140 ~ 160mA (r.m.s. 50~60Hz) Ambient Temperature: In operation -10 ~ +50 In storage -10 ~ +50 Ambient humidity: In operation 95ï¼?RH or less In storage 99ï¼?RH or less (No dew condensation)
MTCS2601 silicon sensing die in SMD ceramic package The MTCS2601 sensors consist of a micro-machined thermal conductivity sensor using four Ni-Pt resistors realized using MEMS technologies. The sensor is mounted in a miniature SMD package, available on tape and real. This MEMS TC sensor, combined with simple low power CMOS standard integrated circuits, is an excellent choice for size-critical leakage OEM detector or miniature vacuum gauge based on Pirani principle requiring ultra-low power consumption, long lifetime and no maintenance. Applications are primary pressure control in rough environment with power and size constraints, or detection in closed volume of gas leakage or moisture, or intrusion. MTCS2601 Thermal Conductivity Sensor Applications * Primary vacuum control following Pirani principle. This sensor is easily added within a pressure valve or directly in vacuum pipes or systems, such as small mechanical pumping systems, vacuum pumping machine and analytical instruments . * Leakage miniature SMD sensor as control integrity of closed systems or instruments under dedicated pressure, able to detect defect like corrosion or simply box opening (load cells; flywheel systems, Dewarâ?¦) MTCS2601 Thermal Conductivity Sensor Features * Thermal conductivity sensor for primary vacuum measurement * Silicon device in SMD ceramic package. Delivery in Tape & Reel * Small dimension compatible with measurement in very small volume * Low power consumption and short time constants * Optimal sensitivity in the range 10^(-2) to 10^(+2) mbar. Possible extension in the range 10^(-4) to Patm * Low cost for volume application * Robust MEMS sensor following physical Pirani principle (hot wire) with no chemical reaction, based on gas thermal conductivity variation versus pressure * Measuring range from 10^(-4) to 1000 mbar with excellent reproducibility * Temperature compensated with excellent matching of compensation and heating resistors on the same silicon die * Ultra small sensor gas volume such as < 0.1 cm^3 * Robust and long MTBF (> 30â??000 hs) due to physical resistive sensing principles * Ultra-low power sensor consumption in operation (< 6 mW) due to the use of MEMS based micromachined silicon sensor with small heated mass. * Ultra-fast response time < 50 ms * Insensitive to mounting position * Gold contact version upon request for corrosive gas environment * Compatible with a simple constant excess temperature operation circuit
O2-M2 Oxygen Sensor Description Alphasense Oxygen sensors use capillary flow control. Unlike partial pressure oxygen sensors, they have good pressure and temperature dependence, making them the best choice in safety applications. Standard galavanic sensors use lead for greatest reliability but fixed lifetime. Specifications * Output: 80 to 120 uA @ 20.9% O2 * Response time t90: < 15 (s) from 20.9% to 0% O2 * Linearity: 0.6 % O2 deviation @ 10% O2 * Operating life: > 24 months *Temperature range: -30 to 55 'C * Pressure range: 80 to 120 kPa * Humidity range: 5 to 95 % rh continuous * Diameter: 20.0 mm (including label) * Heigh: 17.4 mm (including foam ring) * Weight: < 16g
Cheap price Ozone sensor O3 Gas sensor 20ppm SPEC’s printed sensors offer the performance of the best quality electrochemical sensors at a fraction of the price. SPEC’s printed sensors are also ultra-thin, offering easy integration into wireless, portable, and networked solutions. These sensors are ideal for health, environmental, industrial and residential monitoring, because of their high performance, low cost and small size. BENEFITS • Small Size with Low Profile (20x20x3 mm) • Long Life (10 years expected life) • Fast Response (< 15 seconds) • Low Power Consumption • Individually Calibrated (NIST Traceable) • ROHS Compliant APPLICATIONS • Air Quality Monitoring • Industrial Safety • Air Purification Control
Fs1015cl gas flow sensors description Fs1015cl mass flow sensors are specially designed for medical equipment flow monitor and control applications, and are made with world leading proprietary mems mass flow designed channel with a low pressure loss. The current models can be readily applied to ventilators and anesthesia equipments. These sensors can also be sterilized in medical liquids for reuse or hygienic purposes. Fs1015 series can measure a flow up to 150 slpm. Iso-15mm connection model is readily applicable to ventilators and/or anesthesia equipments. Fs1015cl gas flow sensors features and applications - mems thermal mass flow sensor - excellent rangeability with integrated multiple sensing elements - high stability at null and full scale - fast response - low power consumption - low pressure loss Fs1015cl gas flow sensors performance specifications * flow range: 0 to 100; 0 to 150slpm * turn-down ratio: > 100 : 1 * accuracy: +/- (2.0 + 0.5 fs) % * repeatability: +/- 0.5% reading * null shift: â± 30mv * output shift: +/- 0.12%/'c * response time: 8 (max.) ms
Gas Distribution Monitoring Systems : Unlike many competitors who sell boxes, PMAS delivers total secure end-to-end connectivity solution that seamlessly integrates remote devices & sites to centralized management systems i.e. SCADA. No changes in the existing system are needed. Gas Monitoring Systems is operator-independent and allows customer to implement two way communication in a similar manner all around the world. Features: Reliable Industry Leading Prices Easy Maintenance
20889280 Exhaust Gas Temperature Sensor for Volvo Trucks, many QTY
Detection gas CO Measurement Range 0~1000ppm Max detecting concentration 2000ppm Sensitivity (3~12)nA/ppm Resolution ratio 1ppm Response time(T90) 30S Load resistance(recommend) 1000 Repeatability
o3 gas sensor is widely used in water disinfection, food processing and purification, food storage and preservation, medical and health, and household disinfection and purification. In ozone applications, a certain concentration of ozone is an important parameter to ensure disinfection, energy conservation and pollution prevention. But as If the concentration of ozone in the environment is too high, it will cause harm to the human body. Therefore, it is very necessary to effectively monitor the concentration of ozone. The transmitter uses electrochemical technology to measure O3 concentration, and the reaction is quick and sensitive, which can reliably detect ozone concentration. degree. o3 gas sensor product uses 485 communication, standard ModBus-RTU communication protocol, communication address and baud rate can be set, the farthest pass The letter distance is 2000 meters. The equipment is 10-30V wide-voltage power supply, and the enclosure has a high degree of protection, which can adapt to various harsh conditions on site.
ECO-SURE (2E) Carbon Monoxide (CO) Gas Sensor Description ECO-SURE (2E) Carbon Monoxide Sensor, 2 Electrode, long life sensor designed for residential, fire detection and ventilation control applications. UL certified. ECO-SURE (2E) Carbon Monoxide (CO) Gas Sensor Features: * Long Life * Stable Performance * UL Certified - UL2075 ECO-SURE (2E) Carbon Monoxide (CO) Gas Sensor Applications: * Residential * Fire Detection * Ventilation Control ECO-SURE (2E) Carbon Monoxide (CO) Gas Sensor Technical Specifications * Operating Principle: 2-electrode electrochemical * Measurement Range: 0-500 ppm CO * Maximum Overload: 1000 ppm CO * Sensitivity: 45 ± 15 nA/ppm * Response Time (T90):
Cirius1 Infrared Sensor for Hydrocarbons Description and Operation The Cirius range of sensors use the non-dispersive infrared method to detect the presence of gases. The sensors contain an infrared radiation source, a dual element infrared detector and a patented optical arrangement into which gas diffuses. The dual element infrared detector responds to changes in incident radiation and to operate he sensor the infrared source should be pulsed with a duty cycle of 50% at a frequency typically between 2Hz and 4Hz. The sensor produces outputs for active wavelengths, which are modified by the presence of target gas, and for reference wavelengths, which are not modified by the presence of target gas. These outputs consist of a small AC signal in sympathy with the source pulse that is superimposed on a DC voltage pedestal. The sensor also provides a measure of internal temperature via an embedded thermistor. The sensor requires a voltage supply to operate the infrared detector and the connections to the sensor follow the industry standard 7 pin format. To operate the sensor it must be connected to a suitable circuit that provides the source drive and extracts the small AC signals from the DC voltage pedestal. The circuit must amplify the small AC signals, extract a value from them and treat the results to provide a linear output related to gas concentration. The temperature output from the sensor should be used to apply temperature compensation in order to achieve the full performance specification. Cirius1 Infrared Sensor for Hydrocarbons Features * Sensing ranges: 0-100% LFL Methane, 0-100% LFL Hydrocarbons and 0-100% volume Methane * All metal construction * Small internal volume * 'Lightlocked': not affected by external illumination * Low power * Active and Reference signal outputs * Embedded thermistor temperature sensor output * Wide operating temperature range * Fast response * Immunity from 'poisoning' * Fail safe operation * Zero maintenance * Electrically isolated housing
FSM-10H-01 Pre-calibrated Module for LPG Gas FSM-10H-01 is Pre-calibrated Module for LPG gas alarm which applies TGS2610-D00 sensor together, it features durability and stability. The module outputs PWM signal which is proportional to LPG gas concentration (The module has a memory which is stored with factory calibration data), also is capable of detecting sensor wire breakage and short. The module can operate at wide temperature from -10~70'C. Furthermore, the unit is less sensitivity to VOCs gas, it immunes poison by silicon compounds, it suits to work at rugged environment. FSM-10H-01 Combustible Gas Sensor Module Features * PWM, USART digital output proportional to gas concentration * Maintain Free * Compact size, low cost * Meets RoHS requirement FSM-10H-01 Combustible Gas Sensor Module Applications * Detect flammable gas leakage * Flammable gas leakage Detector * Industrial detector FSM-10H-01 Combustible Gas Sensor Module Specification * Gas sensor: TGS2610-D00(Semiconductor) * Detection range: 0 ~ 4,000ppm H2 * Error: ± 300ppm * Response time (T90): �30S * Operation temperature: -10'C ~+70'C * Operation humidity: 20~95%RH(No condensing) * Input voltage (VIN): 5.00.2V DC * Power consumption: 15W
Fsm-t-04a combustible gas sensor module description The fsm-t-04a combustible gas sensor module is a new unit which utilizes tgs6812, catalytic pellistor type gas sensor which features durability and stability. This module provides analog output voltage proportional to hydrogen gas concentration.(there is a memory in module, where factory calibration data has been store). Fsm-t-04a has conformal coatings for moisture proofing and electrical insulation purposes, and is also capable of detecting sensor wire breakage. The unit has a wide range of operating temperature from -10 to +70'c. Furthermore, the unit can detect ch4, lpg, h2. It is less sensitivity to vocs gas, it immunes poison by silicon compounds, it suits to work at rugged environment. Fsm-t-04a combustible gas sensor module features: * linear analog output proportional to gas concentration * maintenance free * compact size * meets rohs requirements Fsm-t-04a combustible gas sensor module applications: * gas leak detection in fuel cell systems * hydrogen & combustible gas leak detectors Fsm-t-04a combustible gas sensor module specification * gas sensor: tgs6812 (catalyâ??tic type) * detection range: 0 ~ 50, 000ppm ch4 * error: 3%lel * response time (t90): 30s * operating temperature: -10'c ~ +70'c * operating humidity: 20~95%rh (no condensing) * input voltage: 5.00.2v dc, 3.00.1v dc * power consumption: 1.5w
MICROceL CF Carbon Monoxide Sensor (CO sensor) Description MICRO 3-electrode carbon monoxide sensor with inboard filter. MICROceL CF Carbon Monoxide Sensor (CO sensor) Key Features & Benefits * A robust carbon monoxide sensor suitable for portable life safety applications * Extremely small size MICROceL CF Carbon Monoxide Sensor (CO sensor) Technical Specifications * Operating Principle: 3-electrode electrochemical * Measurement Range: 0-500 ppm CO * Maximum Overload: 1500 ppm CO * Filter: To remove TLV levels of interfering gases * Sensitivity: 0.045 ± 0.01 µA/ppm * T50 Response Time:
MICROceL HS Hydrogen Sulfide Sensor (H2S Sensor) Description MICRO 3-electrode hydrogen sulphide sensor MICROceL HS Hydrogen Sulfide Sensor (H2S Sensor) Key Features & Benefits * A robust hydrogen sulfide sensor suitable for portable life safety applications * Extremely small size MICROceL HS Hydrogen Sulfide Sensor (H2S Sensor) Technical Specifications * Operating Principle: 3-electrode electrochemical * Measurement Range: 0-100 ppm H2S * Sensitivity: 0.105 ± 0.025 µA/ppm * T50 Response Time:
IRceL CH4 NDIR CH4 Sensor Description Miniature infrared sensor with on-board EEPROM and thermistor IRceL CH4 NDIR CH4 Sensor Key Features & Benefits: * Integrated thermistor for accurate temperature compensation * EEPROM programmed with sensor specfic performance characteristics * Compact Size IRceL CH4 NDIR CH4 Sensor Technical Specifications * Operating Principle: Non-Dispersive Infra-Red * Measurement Range: 0-5% vol. Methane * Accuracy (-20C to +50C): Within ± (0.1% vol CH 4 + 4% of concentration)?? * Response Time (T90): < 35 Seconds * Supply Voltage: 3-5 VDC, 3.3 V to utilise EEPROM calibration * MTBF: > 5 years