Eltek Rectifier Module Flatpack MCU
Original Eltek Rectifier Module Flatpack 2500
24V 1000W Rectifier Module Eltek Flatpack S 24/1000 HE 241122.205 Eltek 241122.205 Profile � The combination of innovative design, efficiency and reliability makes the Flatpack S a perfect choice for telecom and industrial applications. With a system depth of only 250mm the Flatpack S systems will fit in most cabinets. This Flatpack S reduces losses by 30% compared to the current industry standard. The result is reduced total cost of ownership for the customers as well as contribution to reducing the global carbon emissions. Key Features Small Short Power dense, 26 W/inch3 High efficiency OR-ing protection on output Hot pluggable Voltage keying Description Compact and reliable rectifier for rail and power utilities applications Used in the 3U rack with Smartpack S controller, the Flatpack S rectifiers cover 2 to 8kW applications using a minimum of space, less than 18 liters, and low heat dissipation. Applications in these markets demand state of the art, reliable and safe DC power systems. Flatpack S delivers an industry leading power density in its segment, many safety functions, wide operating temperature range and superb reliability in its small 217mm deep housing. Specifications Input Voltage AC (operating range) 85 - 305 VAC Voltage DC (operating range) 85 - 300 VDC DC Output Max Power 1000 W Voltage (adjustable range) 41,7 - 21,5 VDC Current (maximum) 28 ADC Max voltage 21,5 VDC Other Cooling Single fan Efficiency 92,5 % Operating temperature -40 - 85 �°C Dimensions Dimensions WxHxD (mm) 72 x 41,5 x 217 mm Dimensions WxHxD (inch) 2,83 x 1,63 x 8,54 " Weight 0,85 lbs Design Standards Ingress Protection (IP) 20 Certifications Marine DNV 2.4 Valid for part no. 241122.205M
AC to DC converter battery charger 150-1000VDC rectifier 120KW power supply Product Introductionï¼? SANDI AC/DC Charger is specially developed for DC chargers. It has high efficiency, high power factor, high power density, high reliability advantage. AC input 3 phase, DC output voltage range from 150 to 1000VDC can be set, compliant with CE safety requirements, EMC standard EN61000-6-3 and EN61000-6-1 Class A, it is an advanced international level charger. Unique function High efficiency over the full load range, full load efficiency greater than 95% Wide output voltage range, 150-1000VDC, suitable for a wide range of Lithium or lead acid battery 5-inch LCD touch screen, easy to operate Flexible application, charging voltage, charging current, charging time, timing charging can be set by LCD screen, easy to operate Main featuresï¼? Powerful protection, overheating, short circuit, overload, overvoltage, undervoltage, etc. Wide input voltage range: 260~ 530Vac, adaptable to various power grid environments Three-phase AC input without neutral wire: Simplifies system design, eliminates the risk of excessive neutral current, and reduces system costs. Dual DSP design, achieve the full digital control, less components means high reliability Wide input voltage range, allows operation in most poor grid conditions Battery anti backflow: effectively protects the battery while ensuring reliable and safe operation of the system Input, output have protective circuit breaker switch Module adopts hot pluggable design, which is convenient for maintenance. RS485 interface (Optional)
Original Eltek Rectifier Module Flatpack 1500
Leading Bridge Rectifier Module Manufacturer: Insel Rectifiers Welcome to Insel Rectifiers, a hub where cutting-edge power solutions converge with innovation. As a distinguished industry manufacturer, we proudly stand as your trusted destination for premium-quality Bridge Rectifier Modules and Diode Bridge Modules. Bridging Excellence: Inselâ??s Bridge Rectifier Modules Discover excellence at Insel Rectifiers, where our Bridge Rectifier Modules are crafted with precision and expertise to cater to the ever-evolving needs of contemporary industries. Whether utilized in power supplies, electronic devices, or industrial applications, our modules guarantee optimal performance, efficiency, and reliability. Positioned at the forefront of technological innovation, we proudly set the standard for excellence in bridge rectification. Pioneering Diode Bridge Modules Our Diode Bridge Modules showcase Inselâ??s commitment to advancing power solutions. Meticulously designed and crafted, these modules epitomize reliability and efficiency. With a focus on precision engineering and adherence to stringent quality control measures, Insel Rectifiers ensures that every Diode Bridge Module aligns with our reputation for excellence. Insel Rectifiers: Your Trusted Manufacturer As committed manufacturers of Bridge Rectifier Modules, we harness cutting-edge technology and industry expertise to create modules that go beyond industry norms. Our focus on precision engineering, combined with stringent quality control measures, guarantees that every power module stamped with the Insel Rectifiers brand epitomizes durability, efficiency, and innovation. Exploring Rectifier Diode Modules Embark on a journey of exploration with Insel Rectifiers as we present our lineup of Rectifier Diode Modules, where innovation seamlessly merges with reliability. Crafted to deliver flawless power control across various applications, our Rectifier Diode Modules at Insel Rectifiers represent the epitome of power precision. Trust in the excellence of Insel Rectifiers for your electrical systems, where reliability and innovation converge. Choose Insel Rectifiers: Bridging Power and Precision For all your Bridge Rectifier Module needs, Insel Rectifiers stands out as a leader in the industry. Experience a seamless integration of innovation, reliability, and efficiency in every electrical system. Your quest for quality power solutions concludes here with Insel Rectifiers, where power meets precision.
Rectifier Huawei R4850N2 is a digital rectifier that converts the 85~300VAC to 53.5 VDC and possesses the characters of high efficiency, high power density, walk-in start, hot-plug, complete protection, and low noise. The rectifier adopts the latest power monitoring technology, implements the function of monitoring the states of loads and the rectifier status in real time. The output voltage of the rectifier can be adjusted through the host.
Model R4875G1 Description Rectifier Module, R4875, 1U, 4000W, High Efficiency Software and Hardware Attributes Hardware EAN UOM PCS Pack Weight kg Pack Volumem3 Pack DimensionDWH mm Net DimensionDWH mm 281105*40
Rectifier Module DPC DZY-48/50H DZY48/50H(HE)
241122.125 48/1800 HE Eltek Flatpack S 48V 1800W Rectifiers Description Compact HE rectifiers for small to medium telecom applications The Flatpack S rectifiers incorporate Telecom specifications, high efficiency, ORing protection on output and high power in a small, 217 mm deep box. Used in the 1U high, 2 or 3 rectifier positions power rack with Smartpack S controller and battery and load distributions, the Flatpack S rectifiers cover 2 to 5.4kW applications using a minimum of space, less than 6 liters, and low heat dissipation. Applications TELECOM â?? MOBILE / WIRELESS Radio base stations/ cell sites Lte / 4g / wimax Distributed antenna systems Microwave Broadband TELECOM - FIXED Telephony servers / switches Fiber optics / FTTx Microwave Cable BROADBAND Features Small Short Power Density - 47 w/Inch 3 High Efficiency Oring Protection On Output Hot Pluggable Voltage And Power Keying Specifications Model 48/1800 HE Part number 241122.125 INPUT DATA Voltage (nominal) 195 - 277 VAC / 195 - 250 VDC 1) Voltage (operating range) 85 - 305 VAC / 85 - 250 VDC 1) Current (maximum) @ nominal input, full load 9.9 ARMS Frequency 45 - 66 Hz / 0 Hz1) Power Factor > 0.99 at 50% load or more Protection Fuse in L & N, Varistor, Shutdown when input voltage is out of operating range
DZY 48/05H is a digitalized rectifier module with outstanding reliability.
Wholesale original ZTE 48V 3000W Switching Power ZXD3000 V5.5 Rectifier Module
Flatpack2 48V 2000W Super HE Eltek Rectifier Module 241119.106 APPLICATIONS TELECOM - WIRELESS Radio base station / Cell sites LTE / 4G / WiMAX Mobile switching center (MCS) Microwave Broadband TELECOM - FIXED Central office Telephony servers / switches Fiber optics Microwave Broadband Broadcast Data center Key Features SUPER HIGH EFFICIENCY â?? 97.8% HIGH POWER DENSITY â?? 33 W/IN3 COMPATIBLE WITH EXISTING SYSTEMS GLOBAL COMPLIANCE PATENTED TECHNOLOGY HOT PLUGGABLE Super High Efficiency (SHE) rectifiers for Telecom applications The Flatpack2 48V Super HE rectifiers are contributing to setting the new industry standard for efficiency in the DC power market. With an efficiency of 97.8% the Super HE is a premium rectifier particularly suitable for markets and applications where the energy is costly. In grid connected applications the payback time is down to 2 years compared to standard HE rectifiers, and in hybrid applications even faster. The Flatpack2 Super HE is fully compatible with Flatpack2 and Flatpack2 HE systems and can replace any Flatpack2 48V rectifier module. Specifications Model 48/3000 SHE Part number 241119.106 INPUT DATA Voltage (nominal range) 206 - 264 VAC Voltage (operating range) 85 - 264 VAC Frequency 45 - 66 Hz Maximum current 16 ARMS Protection Fuse in Live, varistor for transient protection, shutdown when VIN is out of range
High efficiency and reliable rectifiers The most efficient power conversion module in the industry! Since the launch the Flatpack2 family has expanded into a wide selection of power ratings and voltages. Power systems up to the MW-range can be realized using the 10A model addressing small and larger modular data centersâ?? power needs. 220VDC power systems provide an excellent alternative to traditional AC UPS providing significant efficiency and reliability improvements. With 220V DC, standard components, cables and distribution can be used and most IT equipment designed for 208/ 230V AC can be connected directly to the 220V DC bus. Applications Power Utilities Switch Tripping Control & Protection Systems Emergency Lighting Railway Infrastructure Converter Stations Power Stations Marine And Off-Shore Central Power System Data Center Central Power System Dc/ Dc - Isolate Branches Specifications Part number 241115.815 Model 220 / 2000 HE WOR INPUT DATA Voltage range 85 - 300 V AC/ DC Voltage range (nominal) 185 - 275 V AC/ DC Frequency 0 - 66 Hz Maximum current 11.9 A RMS Power Factor 0.99 (@ 50-100% load) THD (@ 230 VAC) < 5 % (@ full load) Protection Varistor for transient protection, fuse in both lines, shutdown above 300/ 305 V OUTPUT DATA Default voltage 245.3 V DC Voltage range 178.5 1) - 297 VDC
Model 48/2000 SHE Part number 241115.106 INPUT DATA Voltage (nominal range) 185 - 264 VAC Voltage (operating range) 85 - 264 VAC Frequency 45 - 66 Hz Maximum current 11.6 ARMS Protection Fuse in Live, varistor for transient protection, shutdown when VIN is out of range OUTPUT DATA Voltage (default) 53.5 VDC Voltage (adjustable range) 43.21) - 57.6 VDC Max power, nominal input 2000 W Max power, de-rated @VIN = 85 VAC 850 W Max current, @VOUT = 48 VDC 41.7 A Current sharing �±5.0% of max current Static voltage regulation (10-100% load) �±0.5% Dynamic voltage regulation 5.0% for 10-90% or 90-10% load variation, regulation time < 50ms Hold up time (3000W load) >10ms; output voltage > 42 VDC Ripple
Model 48V / 2000W HE Part number 241115.105 INPUT DATA Voltage (nominal) 185 - 275 VAC / 185 - 275 VDC Voltage (range) 85 - 300 VAC / 85 - 275 VDC Frequency 45 - 66 Hz, 15-18.5 Hz1) / 0 Hz Current (maximum) @ nominal input, full load 11.6 ARMS Protection Fuse in both lines Varistor for transient protection Disconnect above 300 VAC/DC OUTPUT DATA Voltage (default) 53.5 VDC Voltage (adjustable range) 43.5 - 57.6 VDC Power (maximum) 2000 W Power @ 85 VAC 850 W Current (maximum) @ nominal input, full load 41.7 A Ripple, 30MHz bandwidth < 100 mVpp Psophometric noise < 2 mVRMS Static Voltage regulation �±0.5% for 10 - 100% load Dynamic Voltage regulation �±5.0% for 10-90% or 90-10% load variation, regulation time < 50ms Protection Fuse, Short circuit proof, High temperature protection, Hot plug-in inrush current limiting OTHER SPECIFICATIONS Efficiency @ nominal input 96 % Isolation 3.0 kVAC - input to output, 1.5 kVAC - input to earth, 500 VDC - output to earth Alarms: Red LED 'on' Low mains shutdown, High and low temperature shutdown, Rectifier Failure, Overvoltage shutdown on output, Fan failure, Low voltage alarm, CAN bus failure Warnings: Yellow LED 'on' Rectifier in power derate mode, Remote battery current limit activated, Input voltage out of range, flashing at overvoltage Normal (module running): Green LED 'on' Acoustic noise, full load @ Tambient = 25�°C full load @ Tambient = 40�°C < 20 dBA < 56 dBA MTBF (Telcordia SR-332 Issue I method III (a)) >350 000 (@ Tambient : 25 �°C) Operating temperature -40 to +75�°C (-40 to +167�°F)4), humidity 5 - 95% RH non-condensing Temperature de-rating >55�°C (131�°F), 1200W @ 75�°C (167�°F) Storage temperature -40 to +85�°C (-40 to +185�°F), humidity 0 - 99% RH non-condensing Dimensions[WxHxD] / Weight 109 x 41.5 x 327mm (4.25 x 1.69 x 13â??) / 1.95 kg (4.3 lbs) DESIGN STANDARDS Electrical safety EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013, UL 60950-1:2014, CSA C22.2 No.60950-1-07:2014, IEC 60950-1:2013 EMC EN 61000-6-1:2019, -6-2:2019, - 6-3:2007 + A1:2011, - 6-4:2019, EN 61000-3-2:2019 ETSI EN 300 386 V.2.1.1, Telcordia NEBS GR1089 CORE Marine DNVGL-CG-03392) Environment ETSI EN 300 019: 2-1 (Class 1.2) & 2-2 (Class 2.3) EU 2015/863 (RoHS) & 2012/19/EU (WEEE) Normal operating conditions as per IEC 62040-5-3:2016 clause 4.2. Other operating conditions as per IEC 62040-5-3:2016 clause 4.3, must be advised
Eltek Flatpack2 Rectifier Module 110V 2000W HE WOR 241119.805 Overview High efficiency and reliable rectifiers The most efficient power conversion module in the industry! Since the launch the Flatpack 2 family has expanded into a wide selection of power ratings and voltages Key Feature Proven Reliability High Power Density Application Flexibility, 2kw - 2m Accepts Dc Input (Dc/ Dc Converter) Global Compliance (Ce, Ul, Nebs) Marine & Offshore Certification Patented Technology Digital Controllers Applications Power Utilities Switch Tripping Control & Protection Systems Emergency Lighting Railway Infrastructure Converter Stations Power Stations Various other applications in demanding industries like marine, oil & gas, process etc. Specifications Part number 241119.805 Model 110-120 / 20A HE INPUT DATA Voltage range (nominal) 176 - 277 V AC 1) Voltage range 85 - 305 V A 1) C Frequency 45 - 66 Hz Maximum current 18.64 ARMS Power Factor 0.99 (@ 50-100 % load) THD (@ 230 VAC) < 4 % (@ full load) Protection Varistor for transient protection, fuse in both lines, shutdown above 300/ 305 V OUTPUT DATA Default voltage 122.5 V DC Voltage range 90.02) - 151.25 V D 1) C # Pb cell supported (1.8 - 2.4 V DC/ cell) 54 -60 # NiCad cell supported (1.05 - 1.65 V DC/ cell) 86 - 91 Max power, nominal input 3025 W1) Max power, 85V input 1280 W Max current 20 A Hold-up time, default voltage and 1500 W load 10 ms, VOUT > 99.7 VDC Current sharing �±5% of maximum current from 10 to 100% load Static voltage regulation �±0.5% from 10% to 100% load and nominal input Dynamic voltage regulation �±5.0% for 10-80% or 80-10% load variation, regulation time < 50ms Rippel and noise, 30 MHz bandwidth < 500 mV PP Protection Overvoltage shutdown, short circuit proof, high temperature, hot plug -in inrush current limiting, ORing diode
36/1000 HE UI ELTEK Flatpack S rectifier 36/1000 HE UI 241122.235 INPUT DATA Voltage (nominal) 185 - 400 VDC / 185 - 275 VAC Voltage (operating range) 85 - 400 VDC / 85 - 305 VAC Frequency DC, 16 2/3 Hz, 45 - 66 Hz Current (maximum) 5.9 ADC / 5.9 ARMS Protection Fuse in Positive & Negative, Reversed polarity insensitive, Shutdown above 420 VDC / 305 VAC OUTPUT DATA Voltage 40 VDC Voltage (adjustable range) 331) - 45 VDC Power (maximum) @ nominal input 1000 W / 450 W @16 2/3 Hz input Power (maximum) @ 85 VDC / 85 VAC input 440 W / 440 W Current (max cont.) @ nominal input 27.8 A (@VOUT < 36 VDC) Hold up time, maximum output power >10ms; output voltage > 33 VDC Current sharing (10 - 100% load) �±5% of maximum current from 10 to 100% load Static Voltage regulation (10 - 100% load) �±0.5% Dynamic Voltage regulation �±5.0% for 10-90% or 90-10% load variation, regulation time < 50ms Ripple < 150 mVPP , 30 MHz bandwidth Protection ORing FET Short circuit proof High-temperature protection Overvoltage Shutdown
ELTEK Flatpack S 36/1000 HE UI rectifier Applications in these markets demand state-of-the-art, reliable, and safe DC power systems. Flatpack S delivers an industry-leading power density in its segment, many safety functions, a wide operating temperature range, and superb reliability in its small 217mm deep housing. Used in the 3U rack with Smartpack S controller, the Flatpack S rectifiers cover 2 to 8kW applications using a minimum of space, less than 18 liters, and low heat dissipation.
Product advantages: ï?¬All-in-one design, high integration and space saving installationï¼? ï?¬Using high-performance lithium iron phosphate cells, laser welding, good cell consistency, designed service life of more than 10 yearsï¼? ï?¬Master-slave mode, passive equalization, can manage the equalization resistance, can set the equalization start voltage difference, and monitor the equalization resistance temperature, more intelligent and safe, and reduce the impact of barrel effect on system energy storage BMS adopts NXP(USA) automotive-grade high-performance chips, with strong anti-interference, good reliability and wide temperature range CAN2.0 communication interface, has the advantages of strong real-time performance, long transmission distance, strong anti-electromagnetic interference ability System parameters can be set through the host computer, such as fan start/stop temperature, charger maximum current setting, charge and discharge current correction, SOC correction, with insulation leakage detection function to prevent oil leakage and short circuit of the cell Integrate Solar charge controller or AC charger optional, BMS communication control, more safe and reliable; Cell temperature management, can be automatically controlled with the air conditioner heater according to the cell condition to make the cell works at the most suitable temperature, and can be linked with the fire protection system as needed Performance characteristics Built-in BMS management system with comprehensive protection and monitoring control functions 5" LCD screen display, easy to operate, can check the temperature, voltage, working status, discharge current, dynamic and static SOC algorithm of a single cell, local display of alarm info, alarm level distinction, accurate positioning of abnormal cells Main control MCU can be centrally controlled and manage peripheral settings (AC charging module, inverter module, solar charging module) to adjust the charging current and voltage of peripheral devices according to the battery charging curve, making the system more reliable BMS battery management system, with SOC automatic calibration and high current passive balance function, combined with perfect operation control and management strategy, to achieve accurate and efficient management EMS energy management system, BMS with solar controller/AC charger, inverter centrally manages charge and discharge, effectively controls the charge and discharge current within the cell usage conditions, protects the cell and extend its service life