Reference voltage 220v Voltage reference 0.7 u un .2 b -1 Current specifications 10-40a Reference frequency 50hz Grading accuracy ++ level Starting current 0.4% ib Voltage power lines 0.8w Communication transmission distance 5m Environmental conditions -25f¬f+70f¬ Relative humidity -_85% Automatic relay depth Data transmission speed Center frequency Dimensions
Power supply (AC/DC) AC 85-265V/DC 85-330V, DC18-90V (option) Power Consumption:
Power supply (AC/DC) AC 85-265V / DC 85-330V or 18-90V DC Power consumption:
Model ytms006 Seal material abs plastic Wire material galvanized steel wire/copper wire nylon Coated wire/stainless steel wire/mixed with kinds of material Color yellow/red/green/blue/purple etc. Printing laser marking Wire length 150mm or others as per request Options printing logo, name, numbering and bar code
Single-phase prepaid kWh meter Type: DDSY716 Name: Single-phase pre-payment electricity kilo watt-hour meters Accuracy: Class 1.0 Class 2.0 Power Consumption:
The main functions and features : Meter circuit design and selection of the components are according as the tolerance of greater choice of environment, so we can guarantee long-term stability of a piece of work. Basically error will not affected by the frequency, temperature, high harmonics, and the installation of location is arbitrary. After sealing unit manufactured without adjustment, greatly reduced the power sectorf+s workload of testing and calibration, meter - button box with pulse interface light coupler facilitate error testing. Detection the constant of pulse output / kw.H to find weather it is the same as constant table marked on nameplate meter, meter also provides low-frequency pulse acquisition (opts). When the one phase of three-phase three-line network is broken, three-phase four-wire network with a two-phase power outages, the watt-hour meter still normal, and display the lost pressure. Power meter in the factory before carefully debugging and test the installation of qualified lead seals. Energy applies to an ambient temperature of -25 fp c to 70 fp c and relative humidity over 85% of the region. Main technical parameters Reference voltage 220/380v 3 * Voltage reference 0.7 u un .2 b -1. Current specifications 3 * 5 (20) a. Reference frequency 50hz. Grading accuracy 2.0 Starting current 0.4% ib. Voltage power lines "0.8w Communication transmission distance 5m. Environmental conditions -25fï+70elative humidity -_85% Automatic relay depth Data transmission speed Center frequency Dimensions. Current specifications 10-40a Reference frequency 50hz. Grading accuracy 2.0 Starting current 0.4% ib. Voltage power lines "2w Communication transmission distance 5m. Environmental conditions -10f¦f+50f¦relative humidity Automatic relay depth Data transmission speed Center frequency Dimensions 166 * 123 * 74.
Electric meter The main functions and features : 1. Energy measurement ways: total single-phase power meritorious =positive meritorious + reverse meritorious. 2. Right through infrared interface programming meter settings and copied sheet data to support meter reading with shrinking table, table factory default is bar code numbers. 3. After the blackout enter low-power work, in the blackout shows that the current state of total consumption, continuous 24-hour blackout revealed about the closure. 4. Meter procedural device to prevent the failure caused flight function, and after the failure to stop measurement. Main technical parameters Reference voltage 220v Voltage reference 0.7 u un .2 b -1 Current specifications 10-40a Reference frequency 50hz Grading accuracy ++ level Starting current 0.4% ib Voltage power lines "2w Communication transmission distance 5 meters Environmental conditions -25fªf+55fª Relative humidity 25f+95+¦ Automatic relay depth Data transmission speed Center frequency Dimensions 150 * 122 * 56.5
Electricity meter Offer!!! we have immediate stock for 200, 000 units and final price offer based on quantity required. Details specification will be provided upon request. 20 unit per carton, weight 19.5kg/carton
Product: DD28 MECHANICAL kWH METER Specifications: Model Number: DD28 Accuracy: Class 2.0 Rated Voltage: 220 Volt Rated Current: 10(30-40)Amp Starting Current: 0.5%Ib Rated Frequency: 50 Hz Constant: 600 rev/kWH Power Loss( Under no current): 2W Meter Base: Black Clock Steel Meter Main Cover: Non Transparent( Black Cover) Meter Terminal: Short or Extended Meter Terminal Material: Copper Voltage Coil Material: Copper Current Coil Material: Copper Wire Protection: The Voltage and current coil connecting wire must be insulated with a cover on it Magnet: Big Size Magnet suitable for 30 A to balance the rotation of the wheel. Size and Dia. of Voltage and Current Coil: As per IEC design to bear 30 Amp continuous current Meter Terminal Size: As per IEC norms with continuous current bearing capacity of 30 Ampere Meter Register: 5 Digits ( 4 Integer , 1 Decimal) Meter Bearing: Jewell Quality: Excellent Serial Number: Each DD 28 must have serial number on its name plate Design Standard: GB/T15283-2008 & IEC 521
Multifunction Power Meter: CPM-12D is a din rail mounting multifunction power meter with high accuracy measurement for single phase and three-phase system. Measuring all basic parameters ; V, I, P, Q, kWh, kVarh etc.. 1 RS485 Modbus RTU communication port as default, LCD display in front panel with buttons for programming. Auto wiring change (see remark as below) via software CE and FCC approved Remark: Auto wiring change have certain condition limit, please refer to operation manual for further details. Â Applications Energy management system Factory automation Intelligent power panel Industrial automation Power Grid automation Community power monitoring Intelligent green building
Single phase electronic kwh meter Main features: Active e. C measure mode is optional. Lcd display format is optional. Tamper function(option): 1p2w 1p1w Cover open alarm(option): meter cover or terminal cover Communication port (option): optical port or rs485 Terminal cover: short or long (transparent) One or two rates controlled by external device (option). Ip53 in accordance with iec60529: 198 Sea transportation standard packing
Name: single phase electricity meter case Material: PC, ABS Can be customized
Product Overview This portable optical power meter with red light source is an accurate portable instrument with long service time specially designed for the installation, operation and maintenance of fiber-optical network. It features fine appearance, controllable backlight display, automatic power off, supper wide testing range for optical power, high accuracy, self-calibration and universal interface. Whats more, the linearity index(mW) and nonlinear index (dBm) will be displayed in a same screen. The optical power meter can be used alone for saving power. Product features The optical power meter with red light of 10mW or 1mW features open self-calibration which could be operated by the user. With two AA batteries, the optical power meter can work continuously for 40 hours. It can work continuously if working with a red light source of 10mW, or 42 hours with a red light source of 1mW. the linearity index(mW) and nonlinear index (dBm) will be displayed on the same screen of the optical power meter. Special universal interface for FC/SC/ST, easy to transformation. Optional auto off. Optional backlight display. Optional steady/flashing red light.
Profile: MPM8000 is a powerful multifunction power meter with modular design, which can be applied for monitoring and controlling of the electrical system. MPM8000 can measure and analyze real time data, such as U, I, P, Q, S,COS, F, kWh, kVAr, etc. MPM8000 has the following functions: RS-485 communication port, 2 energy pulse output (include active energy and reactive energy), Max/min data record, and SOE event record. MPM8000 can extend functions by choosing the external optional modules: harmonic analysis, 8 remote signals on/off mode, programmable 4 analog outputs (0~5V or 4~20mA optional), data storage, Profibus Com. protocol, Ethernet communication functions. The multi-tariff function allows the user to measure energy in any interval (the min. interval is 30min.), which can read the sum, sharp, peak, valley, flat energy data in 30 days, and measure 2nd to 63rd harmonics in statistics. EMC and safety standard IEC61000-4-2 (GB/T17626.2) IEC61000-4-8 (GB/T17626.8) IEC61000-4-4 (GB/T17626.4) IEC61010-1 (GB/T4793.1) Measured Scope: The meter MPM8000 can be applied in single phase, 3-Ph 3Wire, 3-Ph 4Wire system. It can be applied vastly in the field of secondary measurement in high Voltage, low Voltage system, or transmission of measured data. Measured accuracy Parameters Display Direction Accuracy Voltage 0~9999.9kV Class 0.2 scope:5%~100%V Current 0~9999.9kA Class 0.2 scope: 5%~100%A Zero sequence Current Class 0.5 Power factor -1~+1 Directional Class 1 Frequency 45~65Hz ¡À0.01Hz Active Power -9999~9999MW Directional Class 0.5 Reactive Power -9999~9999MVAr Directional Class 0.5 Apparent Power 0~9999MVA Class 0.5 Active Demand -9999~9999MW Class 1.0 Reactive Demand -9999~9999MVAr Class 1.0 Active Energy 0~9999999.99Mwh Directional Class 1.0 Reactive Energy 0~9999999.99MVArh Directional Class 2.0 Phase Angle 0.0¡ã~359.9¡ã Directional Class 2.0 Current total harmonic % 0~100% Class 2.0 Voltage total harmonic % 0~100% Class 2.0. 1unit/carton, 36 unit/big carton.
1.Can be operated in measurement of output power with nw, uw, mw, dB and dBm readings function 2.Optional RS232 Remote Control Interface 3.0.01dBmu precision 4.Can be used for absolute power measurement and relative measurement of link loss. 5.Compact design, portable, light weight, energy-saving 6.Battery for power supply 7.Large LCD display screen, helpful to your eyes. Weight:450g Dimensions 14.0í-7.8í-3.8cm
Digital electricity meters High quality, at reasonable prices As per request
Single-phase smart watt-hour meter adopts large-scale integrated circuit and dedicated ultra-high precision energy measurement soc chip. The communications capability and reliability of its communication module has reached the level of widespread practical application. It is a modern advanced meter designed and manufactured according to the actual energy consumption conditions with the application of digital sampling technology and smt technology. Its performance indicators are in line with iec 62053-21: 2003 electricity metering equipment (a.C.) - particular requirements - part 21: static meters for active energy (classes 1 and 2), iec 62053-23: 2003 electricity metering equipment (a.C.) - particular requirements - part 23: static meters for reactive energy (classes 2 and 3) and iec 62052-11: 2003 electricity metering equipment (a.C.)general requires, tests and test conditions - part 11: metering equipment and other standards. The technical requirements of the smart meter can be made to measure the functional requirements; meanwhile, its telecommunication adopts a dedicated data encryption chip to ensure the security of quantity of electricity, tariff and other information
Feature * DDSU1877 is used to measure the rated frequency of 50Hz, Rated voltage below 265V, single phase AC smart power. * Made of fine quality ABS material, impact resistance, heat-resistant, cold-resistant, and with fine insulating effect. * Alarm when low energy/overload/fraud. * With RS485, GPRS, 4G, or other communication functions for reading meter and setting parameters. * The smart meter adopts the special large scale integrated circuit and special technology to ensure the accuracy and reliability of measurement. * 5+1 bit wide temperature LCD display, real-time display voltage, current, power, total energy kWh. * Comfortable guide rail installation mode 35-36 mm. * Calculate total consumption, real-time view of power consumption via mobile phone. * APP remote control. You can easily control your devices when you leave your home or fast-forward your home, easily control the status of your home device at any time via the mobile APP. * Long service time by high brightness LED indicator. * It can realize the functions of automatic tripping when the balance is exhausted. * After you pay for the electricity, the energy meter could display the remaining electricity. * It could realize remote manual closing and open the energy meter. * The Single phase WiFi energy meter will update the Kwh data when disconnect with wifi. It will not lose the historical data if there is a power outage.
The main functions of this product include metering, display, communication, relay control, data encryption, enabling local and remote meter reading, meter operation monitoring and customer electricity consumption management. This product has the following advantages: DLMS/COSEM communication protocol, good interconnection and operability; Communication methods include infrared communication, RS485 communication, GPRS or PLC communication; Large-capacity data storage capacity, able to record related events such as electricity theft, power supply, switch-opening, and load profile data; Provide LCD display, support automatic display and key display function; Built-in relays, supporting multiple control modes, facilitating power safety and power management; Upgradable software for the meter base layer; Closed structure design, dustproof, waterproof and resistant to external damage.
True-RMS measuring parameters ANSI and IEC 0.2 accuracy class Power quality analysis 4 quadrant energy 2MB onboard memory, can be extended to 16M Data logging High-speed RS485, Ethernet port (option) Measure individual harmonics from 2nd to 63st (option) TOU, 4 Tariffs, 6 Seasons, 6 Schedules Three years warranty With PC management software; web browse data APPLICATIONS Metering of distribution feeders, transformers, generators, capacitor banks and motors Medium and low voltage systems Commercial, industrial, utility Power quality analysis Data logging Monitoring system