Single-phase smart watt-hour meter adopts large-scale integrated circuit and dedicated ultra-high precision energy measurement soc chip. The communications capability and reliability of its communication module has reached the level of widespread practical application. It is a modern advanced meter designed and manufactured according to the actual energy consumption conditions with the application of digital sampling technology and smt technology.
Its performance indicators are in line with iec 62053-21: 2003 electricity metering equipment (a.C.) - particular requirements - part 21: static meters for active energy (classes 1 and 2), iec 62053-23: 2003 electricity metering equipment (a.C.) - particular requirements - part 23: static meters for reactive energy (classes 2 and 3) and iec 62052-11: 2003 electricity metering equipment (a.C.)general requires, tests and test conditions - part 11: metering equipment and other standards. The technical requirements of the smart meter can be made to measure the functional requirements; meanwhile, its telecommunication adopts a dedicated data encryption chip to ensure the security of quantity of electricity, tariff and other information
Product description Three-phase electric energy meter calibrator is used for grid corporation of measurement and energy test center, management department of power supply bureau, national energy measurement of testing authorities, and also used to test each kind of single/three-phase kWh meter of industries and mining enterprises as well as electric meter manufacturers. Meanwhile, the calibrator also can be used as one high-precision standard power source. Technical index Electrical parameters Accuracy 0.05%, 0.1% Power Supply One Phase AC 180-265V, frequency 50/60Hz. AC Voltage Output Range(U1,U2,U3) 57.7V, 100V, 220V, 380V or 69.3V, 120V, 240V, 480V( optional) Adjustment range (0-120)%RG(1) Adjustment �neness 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. Electrical parameters - continued AC Voltage Output - continued Stability 0.01%/120s Distortion 0.3% (Non-capacitive load) Output load each phase 25VA Measuring accuracy 0.05%RG AC Current Output Range(I1,I2,I3) 200mA, 1A, 5A, 20A, 100A Adjustment range (0-120)%RG Adjustment �neness 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. Stability
HS-3303M is a three-phase electric energy meter inspection device designed based on the requirements of the IR46 metering part, which meets the harmonic requirements of the IR46 electric energy meter. It can output square wave, peak wave, current multiple zero-crossing wave, higher harmonics, odd harmonics, sub-harmonics, custom harmonics, etc. This device is equipped with 3 epitopes and has a small structure, which is suitable for product research and development, model selection, random inspection, etc. For more product details,please see Energy Meter Test Bench this page :
Product Description ADL10-E Single Phase Electric Energy Meter General ADL rail- installation Electricity meters is a new generation electricity meter developed by Acrel Co,.Ltd, resulting from many years experience in designing Electricity meters. LCD display and electricity pulse output function is installed in the power meter; clock, rate period parameters can be set also. Data swap with the super ordination machine via RS485 communication interface greatly facilitate the power automated administration. This power meter has advantages of smaller volume, high precision, good EMC, easy installation etc, meet the related technical requirements of electronic power meter in the IEC62053-21,IEC 62053-22 standard. Technical Parameters Voltage Reference voltage AC 220V Reference frequency 45-65 Hz Consumption
Product Description ADL10-E Single Phase Electric Energy Meter General ADL rail- installation Electricity meters is a new generation electricity meter developed by Acrel Co,.Ltd, resulting from many years experience in designing Electricity meters. LCD display and electricity pulse output function is installed in the power meter; clock, rate period parameters can be set also. Data swap with the super ordination machine via RS485 communication interface greatly facilitate the power automated administration. This power meter has advantages of smaller volume, high precision, good EMC, easy installation etc, meet the related technical requirements of electronic power meter in the IEC62053-21,IEC 62053-22 standard. Technical Parameters Voltage Reference voltage AC 220V Reference frequency 45-65 Hz Consumption
The following is the feature of the meter shell: Overall dimensions:281x180x98 Installation dimensions:255 x90.5 1, Bottom case is made of ABS-V0, or ABS-PC(UL94) 2, Upper cover(front cover) is made of PC-V0 3, Lower cover and window is made of PC-V0(UL94) 4, Nameplate is made of 0.5mm Aluminium or PC-V0 or ABS-V0(UL94) 5, Terminal housing is made of bakelite 6, Terminals is made of brass for 1.5-6A,10-40A,20-80A,or on request 7, Signal terminals No. - 2pcs-6pcs are available on request 8, short or long terminal housing cover is available 9, RS232 optical port available on front cover Standard export carton package
An electric meter, or energy meter, is a device that measures the amount of electric energy consumed by a building, tenant space, or electrically powered equipment. Electric utilities use electric meters installed at customers' premises to measure electric energy delivered to their customers for billing purposes
The main functions and features : Meter circuit design and selection of the components are according as the tolerance of greater choice of environment, so we can guarantee long-term stability of a piece of work. Basically error will not affected by the frequency, temperature, high harmonics, and the installation of location is arbitrary. After sealing unit manufactured without adjustment, greatly reduced the power sectorf+s workload of testing and calibration, meter - button box with pulse interface light coupler facilitate error testing. Detection the constant of pulse output / kw.H to find weather it is the same as constant table marked on nameplate meter, meter also provides low-frequency pulse acquisition (opts). When the one phase of three-phase three-line network is broken, three-phase four-wire network with a two-phase power outages, the watt-hour meter still normal, and display the lost pressure. Power meter in the factory before carefully debugging and test the installation of qualified lead seals. Energy applies to an ambient temperature of -25 fp c to 70 fp c and relative humidity over 85% of the region. Main technical parameters Reference voltage 220/380v 3 * Voltage reference 0.7 u un .2 b -1. Current specifications 3 * 5 (20) a. Reference frequency 50hz. Grading accuracy 2.0 Starting current 0.4% ib. Voltage power lines "0.8w Communication transmission distance 5m. Environmental conditions -25fï+70elative humidity -_85% Automatic relay depth Data transmission speed Center frequency Dimensions. Current specifications 10-40a Reference frequency 50hz. Grading accuracy 2.0 Starting current 0.4% ib. Voltage power lines "2w Communication transmission distance 5m. Environmental conditions -10f¦f+50f¦relative humidity Automatic relay depth Data transmission speed Center frequency Dimensions 166 * 123 * 74.