Nominal Current(RMS):200/400/800/1000/1200/2000A Vout@Ipn:+_4.000V Measuring Range:0~+_3000A Supply Voltage DC:+-12-15V Accurancy@Ipn,+25degree Celsius:less than +_0.5% Mounting(mm):12.5*41.0
Nominal Current(RMS):25/50/75/100A Vout@Ipn:+_25/50V Measuring Range:0~+_150A Supply Voltage DC:+-12-15V Accurancy@Ipn,+25degree Celsius:less than +_0.5% Mounting(mm):7.0*12.7  * Closed- loop                                        * Supply voltage: DC +-12~15V  * Capable measurement of currents: DC, AC,pulse with galvanic isolation between primary circuit and secondary circuit.
Nominal Current(RMS):30/300A Vout@Ipn:2.500+_2.000V Measuring Range:+_30/+_300A Supply VoltaIpn,+25
Nominal Current(RMS):10/25/50/75A Vout@Ipn:2.500+_0.625V Measuring Range:0~+_150A Supply Voltage DC:+5V Accurancy@Ipn,+25degree Celsius:less than +_0.5% Mounting(mm):8.2 in diameter
Split core current transformer, current transformer, current transducer, hall effect current sensor, hall effect voltage sensor.
Nominal current(rms):50/100/200/300/400/600a Voutipn:+4.000v Measuring range:0~+900a Supply voltage dc:+15v Accurancyipn, +25degree Celsiusless than1.0% Mounting(mm):10.5*20.5 * open- loop supply voltage: dc +15.0v * capable measurement of currents: dc, ac, pulse with galvanic isolation between primary circuit and secondary circuit.
Nominal Current(RMS):50/100/200/300/400/600A Vout@Ipn:+_4.000V Measuring Range:0~+_900A Supply Voltage DC:+_12-15 Accurancy@Ipn,+25degree Celsius:less than +_1.0% Mounting(mm):10.5*20.5
Type : RTCS100B,RTCS200B,RTCS300B,RTCS400B,RTCS500B,RTCS600B, IPN Primary nominal input current : 100, 200, 300, 400, 500, 600 A IP Measuring range of primary current : 0~300, 0~600, 0~900, 0~900, 0~900, 0~900 A VOUT Nominal output voltage : 41%V VC Supply voltage : 15(5%) V IC Current consumption : VC=15V
Nominal Current(RMS):200/400/800/1000/1200/2000A Vout@Ipn:+_4.000V Measuring Range:0~+_4000A Supply Voltage DC:+-12-15V Accurancy@Ipn,+25degree Celsius:less than +_1.0% Mounting(mm):40.5 in diameter * Open- loop * Supply voltage: DC +-12~15V * Capable measurement of currents: DC, AC,pulse with galvanic isolation between primary circuit and secondary circuit.
Rated input current AC 50A, 100A, 400A AC/DC Accuracy 1.0 Input Impedance (R) approximate zero Linear measuring range 0 - 1.2 times of rated input current Over Load Capacity 30 times of rated input current, 5s Frequency range 25Hzï½?5kHz Isolation Voltage(Input/Output) â?¥2500Vdc, for 1 minute Thermal drift 600ppm/°C Ambient Temperature -25ï½?+70 Mounting DIN Rail 35mm Mounting or screw mounting
Rated input current AC 50A, 100A, 400A AC/DC Accuracy 1.0 Input Impedance (R) approximate zero Linear measuring range 0 - 1.2 times of rated input current Over Load Capacity 30 times of rated input current, 5s Frequency range 25Hz~5kHz Isolation Voltage(Input/Output) 2500Vdc, for 1 minute Thermal drift 600ppm/ Ambient Temperature -25~+70 Mounting DIN Rail 35mm Mounting or screw mounting
Hall components have many advantages, they are strong construction, small volume, light weight, long service life , easy installation, wide bandwidth ( can reach 1 MHZ);vibration resistance, Not afraid of pollution or corrosion of dust ,oil, greasy dirt, moisture , salt mist and so on. • Hall linear elements are excellent accuracy, good linearity. Hall switch elements are no contactless, no in-gage, clear output waveforms, no instant jitter, high-precision positional repeatability. In recent years, with the development of China aerospace industry .Our hall-effect product is widely used in new rocket ,new generation communication satellite, new navigation satellite, new recoverable satellites, chang-e satellites, Shenzhou spacecraft and so on . Its related products is also can widely used in automotive matching, environmental protection, medical equipments, instrument, power protection, office automation and many other civil fields. It is wildly used in frequency driver, contravariant devices, UPS, contravariant welding machine, converting station, electrolyze & electroplating, CNC machine, PC monitoring, grid monitoring, insulated current & voltage testing, Etc. Working Principle 1.Direct measurement principle 2.Magnetic compensation principle Packed in box ,can be customized
I221LY05-25 I222LY05-25 I224LY05-25 Output signals 0-5V AC/DC 0-5V DC 4-20mA Responding time 50us 100ms 150ms Power supply ±12V, ±15V DC ±12V, ±15V, +12V, +24V DC
Rated input current AC 20A, 30A, 40A, 50A, 70A, 90A, 100A AC Output signals 0-20mA ,4-20mA DC Accuracy 1.0 Input Impedance (R) approximate zero Responding Time 300ms
I221LY05-25I222LY05-25I224LY05-25 Output signals0-5V AC/DC0-5V DC4-20mA Responding time50us100ms150ms Power supply12V, 15V DC12V, 15V, +12V, +24V DC
RIT001 has a high gain and measurement accuracy in the full bandwidth range, due to the application of the multi-point zero-flux technology system and high-frequency ripple sensing channel on top of currently existing DC sensor technology. Primary Nominal Current: DC0.01, Overload Capacity: 200% for 1 minute, Power Supply: DC14.2V to 15.8V, Output Voltage: ±1V, Accuracy: 1%, Linearity: 0.2%, Zero Offset Voltage: ±10mV, Dynamic Response Time: 2ms, Frequency bandwidth(-3dB): up to 100KHz, Insulation Voltage (Between primary and secondary): 5KV, Operation Temperature Range: -40 ~ 85.
HIT500 has a high gain and measurement 0.05% accuracy in the broad bandwidth range, due to the application of the multi-point zero-flux technology system and high-frequency ripple sensing channel on top of currently existing DC sensor technology. Accuracy: 0.05%. Linearity: 50ppm. Current Change Rate: 100A/us. Frequency bandwidth(-3dB): up to 100KHz. Insulation Voltage (Between primary and secondary): 5KV. Operation Temperature Range: -40 ~ 85.
HIT600 has a high gain and measurement accuracy in the full bandwidth range, due to the application of the multi-point zero-flux technology system and high-frequency ripple sensing channel on top of currently existing DC sensor technology. Primary Nominal Current: DC600A, AC424A, Overload Capacity: DC720A for 1 minute, Power Supply: DC14.2V to 15.8V, Ratio: 3000:1, Secondary Burden Resistance: 2 ~ 5�©, Accuracy: 0.05%, Linearity: 50ppm, Current Change Rate: 100A/us, Frequency bandwidth(-3dB): up to 100KHz, Insulation Voltage (Between primary and secondary): 5KV, Operation Temperature Range: -40 ~ 85.
Input: AC/DC 20-100A; Output: DC 4-20mA; Accuracy: 1.0%; Power supply: DC 12V, 15V, 24V.
1.Features: firm structure. low power consumption. small size. easy installation. vibration resistance. water vapor proof and dust proof 2.Application: It applies hall effect principle, can measure direct current, alternating current, pulse and current of various irregular wave forms in electrical isolation conditions. 3.Specification: Measuring frequency: 0-100KHz Accuracy: 0.2%-1% Responding time: