Mini circuit breaker has novel structure , reliable performance, high breaking capacity, pleasing outlook and small size. Its case and items are adopted by high fireresistant and shockproof plastics, it mainly used in the building office, house and similar building for illuminating at ac 50hz(60 hz), rated voltage below 400v , rated current below 100 a, distribution circuit and equipment overload, short circuit protection .It can also be used for unfrequent switch over of the circuit under normal conditions .This product conforms to the requirement of iec 60898&gb 10963 standards.
The series of (MCB) mini circuit breakers are suitable for circuit of AC 50HZ or 60HZ.rated voltage up to 400V,rated current up to 63A,they are mainly used in office,singe-pole lighting,distribution system for overload and short circuit protection. The series of miniature circuit-breakers conform to IEC60898 and GBI0963 standards,and comply with CCC,CE...certificate. 42.5*23.5*34cm 22kg 240pcs.
Mini circuit breaker has novel structure , reliable performance, high breaking capacity, pleasing outlook and small size. Its case and items are adopted by high fireresistant and shockproof plastics, it mainly used in the building office, house and similar building for illuminating at ac 50hz(60 hz), rated voltage below 400v , rated current below 100 a, distribution circuit and equipment overload, short circuit protection .It can also be used for unfrequent switch over of the circuit under normal conditions .This product conforms to the requirement of iec 60898&gb 10963 standards.
Mini circuit breaker has novel structure , reliable performance, high breaking capacity, pleasing outlook and small size. Its case and items are adopted by high fireresistant and shockproof plastics, it mainly used in the building office, house and similar building for illuminating at ac 50hz(60 hz), rated voltage below 400v , rated current below 100 a, distribution circuit and equipment overload, short circuit protection .It can also be used for unfrequent switch over of the circuit under normal conditions .This product conforms to the requirement of iec 60898&gb 10963 standards.
Mini circuit breaker has novel structure , reliable performance, high breaking capacity, pleasing outlook and small size. Its case and items are adopted by high fireresistant and shockproof plastics, it mainly used in the building office, house and similar building for illuminating at ac 50hz(60 hz), rated voltage below 400v , rated current below 100 a, distribution circuit and equipment overload, short circuit protection .It can also be used for unfrequent switch over of the circuit under normal conditions .This product conforms to the requirement of iec 60898&gb 10963 standards.
Dz47-63(c45n) series circuit breaker is used in lighting distribution system or motor distribution system for protecting overload and short circuit in the system. This circuit breaker is neoteric in structure, light in weight, reliable and excellent in performance. Its frame and parts adopt plastics of high fire resistant and shockproof. The product, with long life, is mainly used in ac 50hz/60hz single pole 240v or two, three, four poles up to 415v circuit for overload and short circuit protection, as well as for unfrequently switching on&off electric equipment and lighting circuit in normal case. The products comply with iec 60898 & gb10963-1999. Specification: Number of pole: 1, 2, 3, 4pole Rated voltage: 240/415ac Rated current: 1, 3, 6, 10, 16, 20, 25, 32, 40, 50, 63a Breaking capacity: 4.5/6ka Electrical endurance: 10, 000 times
Sell dz47-63 mini circuit breaker Dz47-63 Standard:iec60898 Construction and feature Protection against the overload and short circuit High short circuit capacity Easy mounting onto35 mm din rail The certificate:ccc, ce, cb, s, iram. 43*23.5*17cm 13/12kg 120pcs/ctn
Our featured products automatic transfer switch, circuit breaker, contactor, pilot light,relay, SPD, etc. with solid quality and considerable price and could equip them with enclosure. Circuit Breaker DZ47 is an automatically operated electrical switch designed to protect an electrical circuit from damage caused by overload or short circuit. Its basic function is to detect a fault condition and, by interrupting continuity, to immediately discontinue electrical flow. When a current is interrupted, the arc must be contained, cooled, and extinguished in a controlled way. So that the gap between the contacts can again withstand the voltage in the circuit. Electric ratings:Â a. AC: up to 63A, AC230/400V, AC50/60Hz; b. DC: up to 63A, DC110V/1P, DC125V/2P; Application: for protection of circuits from over-load and short-circuit; and for infrequent making and breaking of circuits under normal operation conditions, as well; Standard: IEC/EN 60898.
Miniature circuit breakers protect installations against overload and short-circuit, warranting reliability and safety for operations. They have two different tripping mechanisms, the delayed thermal tripping mechanism for overload protection and the magnetic tripping mechanism for short circuit protection. ï?? Extra-wide and complete range of MCBs to cover most applications and markets ï?? Meeting worldwide standards ï?? Certificates, documentation, training or background information to support customers due to their daily work ï?? Space and time saving thanks to frame degree updates Main features MCB range offer the possibility to select among different characteristics (B, C, D), configurations (1P, 1P+N, 2P, 3P, 3P+N, 4P), breaking capacities (up to 15 kA) and rated currents (up to 125A). Compliance to the worldwide standards, IEC/EN 60898-1 IEC/EN 60947-2 IEC/EN 60947-3 IEC/EN 61009-1 GB10963.1 GB1096.1 GB14048.2 GB14048.3 GB16917.1 Allowing the use for residential, commercial and industrial applications 25 mm2 and 10 mm2 cylinder lift twin terminals for challenging industrial use. Cross Real contact position indication, directly connected to the moving contact, for more comfort and safety ï?? Environmental Ambient Air Temperature: Operation -5 ... +55°C Storage -40 ... +70 °C Resistance to Shock acc. to IEC 60068-2-27: 30g / 2 shocks / 13 ms Resistance to Vibrations acc. to IEC 60068-2-6: 5g, 20 cycles at 5 ... 150 ... 5 Hz Environmental Conditions: 28 cycles with 55 °C / 90-96 % and 25 °C / 95-100 % Technical Standards: IEC/EN 60898-1 Rated Current (In): 6A, 10A,16A, 20A, 25A, 32A, 40A, 50A, 63A, 80A, 125A Rated Operational Voltage: acc. to IEC 60898-1 230 V AC & 400V AC Rated Insulation Voltage (Ui): acc. to IEC/EN 60664-1 440 V Rated Frequency (f): 50 Hz 60 Hz Rated Ultimate Short-Circuit Breaking Capacity (Icu): (230V AC & 400V AC) 15 kA Rated Service Short-Circuit Breaking Capacity (Ics): (230V AC & 400V AC) 6 kA Instantaneous release: Type C: Lighting protection ; Type D: Motor protection
DZ47 AC MCB circuit breaker series is used in lighting distribution system or motor distribution system for protecting overload and short-circuit condition. The product is light in weightreliable and excellent in performance. It has high breaking capacity up to 6kA. Its case and items are adopted with high fire-resistant and shock proof plastics. Mainly used in AC 50/60Hz single-pole 230V or two three four-pole 400V circuit for overload and short circuit protection as well as for on-off switching electric equipment and lighting circuit. The product complies with EN/IEC60898. Rated current(In) 1A, 2A, 3A, 4A, 6A, 10A, 13A, 16A, 20A, 25A ,32A ,40A, 50A, 63A, 100A Optional Rate voltage(Un) 230VAC / 415VAC / 400VAC / 415VAC Optional Breaking capacity 6kA Rated frequency 50/60Hz Tripping charateristics BCD Number of poles 1P, 2P, 3P, 4P, 1P+N, 3P+N Optional Rated impulse withstand voltage(Uimp) 4kV Electrical endurance 10000cycles Mechanical endurance 10000cycles Terminal Pillar type
DZ47 mini circuit breaker 1. IEC60898-1 2. Rated current: 1~63A 3. Rated capacity: 3KA, 4.5KA For protecting cables and equipments against overload and short citcuit. 240pcs/carton (0.42X0.24X0.34 CBM) 23.5KG.
We can supply c45n mcb dz47 mcb, dz47le, c60n mcb, c65n mcb, ic65n mcb, merlin gerin mcb, lg mcb, abb mcb, mem mcb, legrand mcb, lg mcb, nt-50 safety breaker, s101 screw mcb, e4cb mcb, 200b mcb 200bz mcb, l7 mcb, nc-100h mcb, my mcb mt mcb mu mcb, sx mcb, bh mcb, hydraulic magnetic miniature circuit breaker Cm1 mccb cdm1, dpx mccb, hhb mccb, 3vl siemens mccb, am7 mccb, ns mccb, ds mccb, ea mccb, sa mccb, ab mccb, hfd mccb, 3ve mpcb, 3vu cb, gv Mpcb isomax s molded case circuit breaker (abb mccb) , nf-cs mccb(mitsubishi mccb), dpx mccb(legrand mccb), ns mccb (merlin gerin mccb) etc. Moulded case circuit breaker 1. Product net weight: 128g/pole 2. Packing quantity& weight: 12 pole /box, 20 box/carton, 240 pole/carton . 3. N.W: 22.5 kg/carton 4. G.W:24kg/carton 5. Packing measurement: inner box 22.5¡Á9¡Á8 cm, carton 45¡Á23.5¡Á33.5 cm ( ie 0.036 cbm)
2P 500V DC solar mini circuit breaker Description: PQB1Z-63 2P PV DC breaker supplementary protectors are designed to provide overcurrent protection within appliances or electrical equipment, where a branch circuit protaction is already providedd or not required. Devices are designed for direct current(DC) control circuit applications. Technical Parameter: Item DC MCB Code PQB1Z-63 Pole 1P 2P 3P 4P Voltage 250VDC 550VDC 800VDC 1000VDC Current 1A,3A,6A,10A,16A,20A,32A,40,50A,63A Standard IEC/EN60947 Breaking Capacity 6KA,10KA Characteristic Curve B,C,D Working Temperature "-5°"to +40° Protection Degree IP20 Electrical life More than 8000times Mechanical life More than 2000times Dimension(W)X(H)X(D) 18X80X71 36X80X71 54X80X71 72X80X71 Installation 35MM DIN RAIL Accessory YES Installation Altitude â?¤2000M
Main Specification Trademark:CNHUNG/OEM Poles:2P/4P Rated current(A): 25,40, 63 Rated Voltage(V):AC230 / 400V Frequency:50 / 60Hz Rated residual action current(mA):30, 100, 300 -
Standard: IEC/EN60898-1 GB/T10963.1 Instantaneous trip type: B/C/D The number of poles: 1P/1P+N/2P/3P/3P+N/4P Rated short circuit breaking capacity (Icn): 10kA Rated working current (In): 1-63A Rated working voltage( Ue): AC 230/400V Rated operating frequency: 50/60Hz Rated insulation voltage (Ui): 500V Rated impulse withstand voltage (Uimp): 4kV Mechanical/electrical life: 10000/4000 Time
Standard: IEC/EN60898-1 GB/T10963.1 Instantaneous trip type: B/C/D The number of poles: 1P/1P+N/2P/3P/3P+N/4P Rated short circuit breaking capacity (Icn): 6kA Rated working current (In): 1-63A Rated working voltage (Ue): AC 230/400V Rated operating frequency: 50/60Hz Rated insulation voltage (Ui): 500V Rated impulse withstand voltage (Uimp): 4kV Mechanical/electrical life: 10000/4000 Times
Standard: IEC/EN60898-1 GB/T10963.1 Instantaneous trip type: B/C/D The number of poles: 1P/1P+N/2P/3P/3P+N/4P Rated short circuit breaking capacity (Icn): 6kA Rated working current (In): 1-63A Rated working voltage (Ue): AC 230/400V Rated operating frequency: 50/60Hz Rated insulation voltage (Ui): 500V Rated impulse withstand voltage (Uimp): 4kV Mechanical/electrical life: 10000/4000 Times
Standard: EC/EN60898-1 GB/T10963.1 Instantaneous trip type: B/C/D The number of poles: 1P/1P+N/2P/3P/3P+N/4P Rated short circuit breaking capacity (Icn): 4.5/6kA Rated working current: In 1-63A Rated working voltage (Ue): AC 230/400V Rated operating frequency: 50/60Hz Rated insulation voltage (Ui): 500V Rated impulse withstand voltage (Uimp): 4kV Mechanical/electrical life: 10000/4000 Times
Standard: IEC/EN60898-1 GB/T10963.1 Instantaneous trip type: B/C/D The number of poles: 1P/1P+N/2P/3P/3P+N/4P Rated short circuit breaking capacity( Icn): 10kA Rated working current (In): 1-63A Rated working voltage (Ue): AC 230/400V Rated operating frequency: 50/60Hz Rated insulation voltage (Ui): 500V Rated impulse withstand voltage (Uimp): 4kV Mechanical/electrical life: 10000/4000 Times