BC-5300 mindray auto hematology analyzer. Weight
Mindray BC1800 BC2300 BC2800 BC3000 BC3200 JXK-203 Diluent 20L JXK-204 Lyser 500ml JXK-205 Cleaner 5LÃ?2 JXK-206 EZ Cleaner 100ml JXK-207 Probe Cleaner 50ml
80 samples per hour--- Fully auto cap piercing sampler--- Sample rotor valve technology--- Parameters: 19 parameters + 3 histograms Principle: electrical impendence for counting and sft method for hgb Throughput: up to 80 samples per hour Sampler capacity: 50 samples Testing mode: manual open(whole blood, prediluted); sampler close(whole blood) Sample volume: sampler mode: whole blood 200 ª8l Manual mode: whole blood 200ª8l; prediluted 40ª8l Aperture diameter Wbc: 100ª8m Rbc/plt: 80ª8m Memory: 35, 000 results with histogram Performance: Parameters precision cv% Wbc(10 /l) 2.0% Rbc 1.5% Plt 4.0% Mcv(fl) 0.5% Hgb(g/dl) 1.5% Display Large color lcd, displays all parameters result with histogram of wbc, rbc and plt Resolution: 800íß600 Menu Count, sample mode, review, quality control, system setting, reference value, system service, calibration, copyright, shutdown Alert: 25 sets of alert message Input/output: usb(keyboard, mouse, flash disk), rs232, parallel Print:graphic thermal printer with various printing format, optional external printer Operating environment: Temperature: 18-30íµ Humidity: ín70% Power requirement: Ac100-240v, 60/50hz Dimension 600mm(l)íß520mm(w)íß57 0mm(h) Weight 30kg
3-part differentiation of wbc: 19 parameters + 3 histograms 2 sample modes: whole blood and prediluted Throughput: ín1.5 minute per sample Up to 100, 000 sample results (including histograms) can be stored Built-in thermal recorder, optional external printer Auto reverse flushing, block clearing Color lcd display 272mm(l)íß 420mm(w)íß 390mm(h) 24kg
3-part differentiation of wbc: 19 parameters + 3 histograms 2 sample modes: whole blood and prediluted Throughput: less than 2 minute per sample Up to 35, 000 sample results (including histograms) can be stored Built-in thermal recorder, optional external printer Auto reverse flushing and high pressure burn, block clearing Liquid sensor Color lcd display 400mm(l)íß400mm(w)íß460mm(h) 25kg
Fully automated, compact, flexible and low cost 3-part differentiation of wbc: 19 parameters + 3 histograms 2 sample modes: whole blood and prediluted Throughput: 60 samples per hour Automatic diluting, lying, mixing, rinsing and clog-clearing Automatic sample probe cleaning Up to 35, 000 sample results (including histograms) can be stored Built-in thermal recorder, optional external printer Reagent expired alarm Color lcd display 40cm(l)40cm(w)46cm(h) 25kg
Innolab200600002PS-Semi-Auto Biochemistry Analyzer
SelectraPro-XL6003703ET Fully Auto Biochemistry Analyzer
SelectraPro-S-Lite6003543VS Fully Auto Biochemistry Analyzer
Fully Auto Biochemistry Analyzer
SelectraPro-M-Lite6003400VS Fully Auto Biochemistry Analyzer
Microlab-3006002310VS Semi Auto Biochemistry Analyzer
19 parameters + 3 histograms Up to 60 tests per hour 9.7µL sampling volume for testing 8.4 inches touch screen Storage report >1000 cases 9.7 �µL venous blood/20 �µL peripheral blood sampling volume for testing Storage report (with picture) >1000 cases, unlimited expansion with U disk Available U disk software upgrade Real-time display and detection of sample temperature Wide range power supply design AC100V-264V
Mindray 2800 Single Chamber Hematology Analyzer ,easy To Operate ,compact,economical And Less Reajent Comming Analyzer Suitable For Small Workloads Also This Machine Is User Friendly ,non Problematic Fast Nand Accurate In Analysis Of Sample Without Consistancy. (fully Refurbished Equipment)
Forever Medical YJ-H7100 Automatic Hematology Analyzer : It mainly designed to detect the parameters of the series of red blood cells and hemoglobin,platelet and leukocyte in the blood. It is a requisite vitro diagnostic equipment which is applied to quantitative analysis of blood cells in clinical and laboratory. Best Advantages : 1. Easy to operate 2. Carry-over protection by automatic probe interior and exterior washing 3. Both whole blood and prediluted blood test modes are available 4. Automatic self-checking and warming function 5. Automatic standby function 6. Safe reagent without any harm to the environment
Feture: - laser scatter differential and electronic resistance for basophils to ensure outstanding accuracy. - complete 5-part differential menu. - 60 tests/hr. - touch screen operation Sample volume: 40 ul Aperture diameter Wbc/baso: 100um Rbc: 80um Work model: three channels test, auto-add quantitative lyses. Data storage¡êomore than 35000 sample results with 3 histograms and 1 Diff scattergram. Rate of crossing pollution Wbc< 3.5%, rbc/hgb
Features: 5-part differentiation, 27 parameters Laser scatter + Chemical dye +Flow cytometry Up to 60 samples per hour Independent channel for Basophil measurement 10.4 inches high resolution TF touch screen Powerful capability to flag abnormal cells Large storage capacity: up to 50,000 samples Support USB/LAN /bi-directional LIS Support external inkjet and Laser Printer Specification: Principles Impedance method for RBC andPLT counting Cyanide free reagent for hemoglobin test Laser scatter, Chemical dye,  Flow cytometry for WBC-5 part differential analysis and WBC counting Assay Items 27 parameters, 5 parts of differential WBC Parameters RBC, MCV, HCT, RDW-SD. RDW-CV, HGB, MCH, MCHC, PLT, MPV, PCT, PDW, WBC, LYM#, LYM%, MON#, MON%, NEU#, NEU%, EOS#, EOS%, BAS#, BAS%, ALY#*, ALY%*, LIC#*, LIC%* 3  histograms for WBC, RBC, PLT 3 DIFF scattergrams and 1 BASO scattergram Reagent DIL-C Diluent, LYC-1LYSE, LYC-2LYSE, CLE-P Sample Volume 15uL(Venous blood), 15uL(Capillary blood), 20uL(Prediluted)
Feature : 3-part differentiation of WBC, 23 parameters, up to 60 samples test per hour Electrical resistance for counting and SFT method of hemoglobin Low sample comsumption : venous 9.8 ul, prediluted 20ul for twice testing one time 8.4 inch color TFT, Windows interface all testing parameter displayed simultaneously Windows operation system graphical buttons mouse and keyboard operation Automatic diluting, Mixing, rinsing and clog clearing Automatically sample probe cleaning ( inside and outside) Large storage capacity : up to 10,000 samples + 3 histograms Internal thermal-sensitive printer or external printer RS 232 interface, PC connecting
Gas analyser Analysers for stack and ambient air pollution monitoring Also used for petrol and diesel vehicles
Diesel vehicle exhaust gas analyzer (can also be used in gasoline vehicle), belong to customized products, non standard. Increase the reverse blowing system and filtering, purifying device. Can be used for the detection and analysis of diesel oil as fuel of vehicle exhaust emissions group points. ã??Main technical parametersã?? exhaust gas analyzer measuring range COï¼?0ï½?10.0 10-2(%) CO2ï¼?0ï½?20.0 10-2(%) HCï¼?0ï½?9999 10-6(ppm) O2ï¼?0ï½?25.0 10-2(%) NOï¼?0ï½?5000 10-6(ppm) oil temperatureï¼?18ï½?150 speedï¼?100ï½?20000rpm resolving power COï¼?0.01% CO2ï¼?0.1% HCï¼?1ppmO2ï¼?0.01% NOï¼?1ppm oil temperatureï¼?0.1 speedï¼?1rpm Repetitive error â?¤±2% Zero drift COï¼?±0.06 10-2(%)/4h CO2ï¼?±0.5 10-2(%)/4h HCï¼?±30 10-6(ppm)/4h O2ï¼?±0.5 10-2(%)/4h NOï¼?±30 10-6(ppm)/4h Distance drift No more than shown value error allowed (4 hours) Indication error COï¼?±5%ï¼?absolute errorï¼?±0.03 10-2 ï¼? CO2ï¼?±5%ï¼?absolute errorï¼?±0.5 10-2ï¼? HCï¼?±5%ï¼?absolute errorï¼?±10 10-6 ï¼?±5%ï¼?absolute errorï¼?4001ï½?10000ppmï¼? O2ï¼?±5%ï¼?absolute errorï¼?±0.1 10-2ï¼? NOï¼?±4%ï¼?absolute errorï¼?±25 10-6ï¼? environment condition oil temperatureï¼?±2ï¼?relative errorï¼? speedï¼?±1.0%ï¼?relative errorï¼? temperatureï¼?0ï½?40 humidityï¼?â?¤80% atmospheric pressureï¼?60ï½?105KPa Power Supplyï¼?AC 220V±10%ï¼?50Hz±1Hz(Automobile power supply inverter) Preheating time 10min Weight Measurement unitï¼?10Kg vice machineï¼?3Kg Volume Measurement unitï¼?610 * 500 * 330mm Auxiliary machine:500 * 350 * 330mm Sampling method Exhaust gas: direct sampling, sampling tube length 5m, sampling probe length 900mm; Temperature: the temperature measuring head into the engine lubrication oil scale hole, insert the oil rod and the length of the same length, rubber stopper blocked, to prevent oil jet and wire length: 5m; Speed: the tachometer speed clip in high pressure flexible gasoline engine, can determine the speed of a gasoline engine. Display mode LCD large screen liquid crystal display major function 1)Meet GB18285-2005 national standard requirements, measurement of motor vehicle gasoline engine emissions of HC, CO, CO2, O2 and NO concentrations,Of HC, Co, CO2, the advanced NDIR regardless of light and infrared analysis technology (imported from movement detection equipment to meet the requirements of national standard OIMLR99 0 level precision, high precision, strong stability) and of O2 and no by the new electrochemical analysis technology for detection. 2)With idle speed, double idle test function; 3)Auto calculation shows that the excess air coefficient isï¼? 4)Equipped with RS-232C digital serial communication interface, convenient networkingï¼? 5)Matching speed and temperature measurement functionï¼?