Feture:
- laser scatter differential and electronic resistance for basophils to ensure outstanding accuracy.
- complete 5-part differential menu.
- 60 tests/hr.
- touch screen operation
Sample volume: 40 ul
Aperture diameter
Wbc/baso: 100um
Rbc: 80um
Work model: three channels test, auto-add quantitative lyses.
Data storage¡êomore than 35000 sample results with 3 histograms and 1
Diff scattergram.
Rate of crossing pollution
Wbc< 3.5%, rbc/hgb<2.0%, plt<5%
Display ¡êo large color tft touch screen; resolution: 640¡¨¢480
Information edit: input patients¡¡¥ information, including name, division,
Inspector ect.
Alarm/hint ¡êo 25 alarm/hint functions along with expert diagnosis
System.
Input/output interface: rs232¡¨¢2, usb, 1 parallel printer, 1 keyboard
Printer: graphic thermal printer with various printing format,
Optional external printer.
Operation environment
Temperature¡êo18~25¡æ¡ê¬
Relative humidity¡êo¡§q80% ,
Atmosphere: 86.0kpa -106.0kpa
Storage environment:
Temperature¡êo-20 ¡æ~55¡æ
Relative humidity¡êo¡§q93%
Power requirement: ac 220, 50hz
Power requirement: ac 220, 50hz
Input power: 150va
Fuse: ac 220v 50hz 2a
Overvoltage: ii type
Pollution degree: second degree
Related keywords: blood analyzer , blood cell counter , haemacytometer , hematology analyzer
Dimension¡êo 571(h)*410(w)* 478(l)mm3
Weight: 34kg
Package: wooden box
Sample volume: venous mode: 9.6ul venous Capillary mode: 9.6ul capillary Prediluted mode: 20ul capillary Working mode: double counting pathway +independent hgb detection system Operation mode: color windows interface, figure button, mouse input Dimension of gem aperture: wbc: 100um rbc/plt: 80 um Throughput: more than 60 samples per hour, 24 hour running continuous auto stand-by Storage: up to 35000 sample results including histograms can be stored Display: large color lcd display with 10.4inch, resoluion:640¡¨¢480 dot Interface: 1parallel interface, 2usb interface, 2ps/2 interface, 2rs232 interfaces (with net), 1vga interface Report: built-in rapid thermal recorder, optional external printer, 8 report formats Structure: fan-door structure, flexible and easy to use Ambientoperating:temperature:0degree-40degree.Humidity:10%-90% Power supply: ac100-240v`~50/60hz
3/5 part differentiation, 19/20 parameters +3 histograms Double apertures for wbc and rbc/plt separately Whole blood and pre-diluted counting modes available for different patients' sample requirement 45/60 samples/hour throughput Optional barcode scanner, printer port and other enhanced functions. 14-25kg
Two counting mode: whole blood & prediluted Patented aperture technology: automatic clog-clearing with high pressure and lower rate of clog Storage capability of up to 16000 sample results with histograms Automatic diluting, lyzing, mixing, rinsing Built-in thermal printer Bar code scanner ( optional) Reagent alarm system ( optional) Net weight: 19kg Gross weight: 22kg
12 predetermined animals + 4 options, Wbc 3 part diff 19 parameters + 3 histogram 2 sample modes: whole blood and prediluted Throughput: less than 2 minute per sample Up to 35, 000 sample results (including histograms) can be stored Built-in thermal recorder, optional external printer Auto reverse flushing and high pressure burn, block clearing Liquid sensor Color lcd display 400mm(l)íß400mm(w)íß460mm(h) 25kg
80 samples per hour--- Fully auto cap piercing sampler--- Sample rotor valve technology--- Parameters: 19 parameters + 3 histograms Principle: electrical impendence for counting and sft method for hgb Throughput: up to 80 samples per hour Sampler capacity: 50 samples Testing mode: manual open(whole blood, prediluted); sampler close(whole blood) Sample volume: sampler mode: whole blood 200 ª8l Manual mode: whole blood 200ª8l; prediluted 40ª8l Aperture diameter Wbc: 100ª8m Rbc/plt: 80ª8m Memory: 35, 000 results with histogram Performance: Parameters precision cv% Wbc(10 /l) 2.0% Rbc 1.5% Plt 4.0% Mcv(fl) 0.5% Hgb(g/dl) 1.5% Display Large color lcd, displays all parameters result with histogram of wbc, rbc and plt Resolution: 800íß600 Menu Count, sample mode, review, quality control, system setting, reference value, system service, calibration, copyright, shutdown Alert: 25 sets of alert message Input/output: usb(keyboard, mouse, flash disk), rs232, parallel Print:graphic thermal printer with various printing format, optional external printer Operating environment: Temperature: 18-30íµ Humidity: ín70% Power requirement: Ac100-240v, 60/50hz Dimension 600mm(l)íß520mm(w)íß57 0mm(h) Weight 30kg
Product Details: Instrument Name Haematology Analyzer Usage/Application Laboratory Brand Spinreact Differential Type 5-Part Number Of Parameters 34 Sample Mode Whole Blood Display Digital Sample Volume 20 Micro Litre Storage 200000 Sample Results No. Of Reagents Used 4 Power 250 VA Weight 35 kg Dimension 490x332x459 mm Screen Size 10.4 inch Voltage 100-240 V AC Spincell 5compact Compact 5 Diff analyzer Compact 5 Diff analyzer Reticulocyte count Determination of reticulocytes Laser multi-dimensional cell classi cation Multi-dimensional laser classi cation Up to 60 samples per hour throughput Up to 60 samples per hour Supports both whole blood and capillary blood samples Analyze both blood samples total like blood cap
Automatic Hematology Analyzer is mainly designed to detect the parameters of the series of red blood cells and hemoglobin,platelet and leukocyte in the blood.It is a requisite vitro diagnostic equipment which is applied to quantitative analysis of blood cells in clinical and laboratory. Features 1. Easy to operate 2. Carry-over protection by automatic probe interior and exterior washing 3. Both whole blood and prediluted blood test modes are available 4. Automatic self-checking and warming function 5. Automatic standby function 6. Safe reagent without any harm to environment
20papameters, 3histograms Double chamber and appertures Whole blood and prediluted counting modes both available 60 samples / h 20000 samples can be stored External keyboard. Nw:18.6kg, gw:21.8kg Measurement:35*43*44cm Package:76*62*56cm
3-part differentiation of wbc: 19 parameters + 3 histograms 2 sample modes: whole blood and prediluted Throughput: ín1.5 minute per sample Up to 100, 000 sample results (including histograms) can be stored Built-in thermal recorder, optional external printer Auto reverse flushing, block clearing Color lcd display 272mm(l)íß 420mm(w)íß 390mm(h) 24kg