Alstom Gbcdg21af001zmch Obsoleted Model Ref.gbcdg21af101zmch Obsoleted Model Ref.gbcdg21af101zmch
Alstom Gbcdg21af003zmch Obsoleted Model Ref.gbcdg21af102zmch Obsoleted Model Ref.gbcdg21af102zmch
Alstom Gbcdg61eg001zmch Obs.replaced by Gbcdg61eg101zmch Obs Model .replaced by Model List Gbcdg61eg101zmch
'ALSTOM' Protection Relay MODEL NO:- P64392AE6M0060M;
'ALSTOM' Protection Relay MODEL NO:- P94VP16A7C0540A; Advanced Transformer Protection, Control and Condition Monitoring Transformers are high capital cost assets in electrical power systems. Internal faults are a risk for all transformers, with short-circuits dissipating the highest localised energy. Unless cleared quickly, the possibility of rewinding will diminish and core damage may become irreparable.The MiCOM Agile P642, P643 and P645 address all these issues - preserving service life and offering fast protection for transformer faults. A transient bias technique has been included, enhancing relay stability and CT requirements. CT saturation and no gap detection techniques have been included to improve the low set differential element operating time during CT saturation where the second harmonic blocking might be asserted. An external fault detection algorithm has been incorporated to prevent the CT saturation and no gap detection from affecting the second harmonic blocking .
GBCCUM21PF153A DEFINITE TIME REVERSE POWER RELAY Technical Specifications Model No : CCUM21PF153A CCUM21 Case Size - 1-1/2D VERT. 10T Current Rating Cup unit - 1 Amp CT V.T Secondary Volts - 110 V ac Torque Angle (MTA)I Lead V- 30 Degree Frequency - 50 Hz Aux. Voltage - 48 / 50 V dc Contacts - 2 N/O S/R Flag - Yes Mounting - Flush Timing Range - 2.5 - 25 Secs Ext.Resistor - 400 Ohms 35 Watts Name Plate VTT RZF9151-601 Name Plate RFH9072-604 Outline Diagram MFJ 013 & RFJ0349 Wiring Diagram MPDZ609-01-1
GBCCUM21PF154J DEFINITE TIME REVERSE POWER RELAY Technical specification Relay model no CCUM21PF154J Relay type CCUM 21 Case size 1.5D S/E V.T.Secondary voltage 110 V ac Frequency 50 Hz Current 1 amps Torque angle(M.T.A) 30 Degree Aux.voltage 110 V ac Contacts 2 N/O S/R Flag Yes Timing range 0.5 to 5 Secs Name plate VTT RZF9151 601 Name plate RFH9072 604 Outline drawing MFJ 013 Wiring diagram MPDZ 609 - 02-1
GBCCUM21PF161A DEFINITE TIME REVERSE POWER RELAY Technical Specifications Model No : CCUM21PF161A CCUM21 AUX. CURRENT OR VOLTAGE - 110/125V DC C.T. SECONDARY - 5 AMP C.T. CASE SIZE - 1-1/2D VERT. 10T CONTACTS (S/R OR H/R) - 2 N/O S/R FLAG - YES FREQUENCY - 50 HZ MOUNTING - FLUSH MTA PHASE-CHAR ANGLE - 30 DEGREES TIME DELAY P/U OR D/O - 0.5 - 5 SECS. V.T/P.T SECONDARY - 110V AC External Resistor 1.3 K.OHMS Name Plate RFH9072-604 RZF9151-601 Outline Diagram MFJ013 & FJ0349 Wiring Diagram MPDZ609-01-1
GBCCUM21PF162A DEFINITE TIME REVERSE POWER RELAY Technical Specifications Model No : CCUM21PF162A CCUM21 AUX. CURRENT OR VOLTAGE - 110/125V DC C.T. SECONDARY - 5 AMP C.T. CASE SIZE - 1-1/2D VERT. 10T CONTACTS (S/R OR H/R) - 2 N/O S/R FLAG - YES FREQUENCY - 50 HZ MOUNTING - FLUSH MTA PHASE-CHAR ANGLE - 30 DEGREES TIME DELAY P/U OR D/O - 1 - 10 SECS. V.T/P.T SECONDARY - 110V AC External Resistor 1.3 K.OHMS Name Plate RFH9072-604 RZF9151-601 Outline Diagram MFJ013 & FJ0349 Wiring Diagram MPDZ609-01-1
GBCCUM21PF163A DEFINITE TIME REVERSE POWER RELAY Technical Specifications Model No : CCUM21PF163A CCUM21 CASE SIZE - 1-1/2D VERT. 10T CURRENT RATING CUPUNIT - 5 AMP C.T. V.T/P.T SECONDARY - 110 V AC TORQUE ANGLE MTA I LEAD V - 30 DEGREES FREQUENCY - 50 HZ MOUNTING - FLUSH TIME DELAY P/U OR D/O - 2.5 - 25 SECS. AUX.VOLTAGE - 110/125 V DC CONTACTS - 2 N/O S/R FLAG - YES External Resistor 1.3 K OHMS 35 W Name Plate RZF9151-601 RFH9072-604 Outline Diagram MFJ013 & FJ0349 Wiring Diagram MPDZ609-01-1
GBCCUM21PF166A DEFINITE TIME REVERSE POWER RELAY Technical specification Relay model no CCUM21PF166A Relay type CCUM 21 Case size 1-1/2D V 10T Aux.current or voltage 110/125V dc C.T.Secondary 5 amps Contacts (S/R OR H/R) 1 N/O 1 N/C S/R Flag Yes Mounting Flush Frequency 50 Hz MTA Phase-char angle 30 Deg Time delay P/U OR D/O 0.5 - 5 Secs V.T/P.T Secondary 110V ac External rest 1.3 K.Ohms Name plate-1 RFH9072-604 Name plate-2 RZF9151-601 Outline drawing MFJ 013 & FJ0349 Wiring diagram MPDZ 609.01-2
GBCCUM21PF168A DEFINITE TIME REVERSE POWER RELAY Technical specification Relay model no CCUM21PF168A Relay type CCUM 21 Case size 1-1/2D VERT.10T C.T.Secondary 5 amps V.T/P.T SECONDARY 110V ac Frequency 50 Hz MTA Phase-Char angle 30 Deg Aux.current or voltage 110/125V dc Contacts (S/R OR H/R) 1 N/O 1 N/C S/R Flag Yes Mounting Flush Timing range 2.5 - 25 secs External rest 1.3K.Ohms Name plate RFH9072-604 Name plate-1 RZF9151-601 Outline drawinG MFJ013 & FJ0349 Wiring diagram MPDZ 609-01-2
GBCCUM21PF171A DEFINITE TIME REVERSE POWER RELAY Technical Specifications Model No : CCUM21PF171A CCUM21 AUX. CURRENT OR VOLTAGE - 110/125V DC C.T. SECONDARY - 1 AMP CT. CASE SIZE - 1-1/2D VERT. 10T CONTACTS (S/R OR H/R) - 2 N/O S/R FLAG - YES FREQUENCY - 50 HZ MOUNTING - FLUSH MTA PHASE-CHAR ANGLE - 30 DEGREES TIME DELAY P/U OR D/O - 0.5 - 5 SECS. V.T/P.T SECONDARY - 110V AC External Resistor 1.3 K.OHMS Name Plate RFH9072-604 RZF9151-601 Outline Diagram MFJ013 & FJ0349 Wiring Diagram MPDZ609-01-1
GBCCUM21PF172A DEFINITE TIME REVERSE POWER RELAY Technical Specifications Model No : CCUM21PF172A CCUM21 AUX. CURRENT OR VOLTAGE - 110/125V DC C.T. SECONDARY - 1 AMP CT. CASE SIZE - 1-1/2D VERT. 10T CONTACTS (S/R OR H/R) - 2 N/O S/R FLAG - YES FREQUENCY - 50 HZ MOUNTING - FLUSH MTA PHASE-CHAR ANGLE - 30 DEGREES TIME DELAY P/U OR D/O - 1 - 10 SECS. V.T/P.T SECONDARY - 110V AC External Resistor 1.3 K.OHMS Name Plate RFH9072-604 RZF9151-601 Outline Diagram MFJ013 & FJ0349 Wiring Diagram MPDZ609-01-1
GBCCUM21PF173A DEFINITE TIME REVERSE POWER RELAY Technical Specifications Model No : CCUM21PF173A CCUM21 AUX. CURRENT OR VOLTAGE - 110/125V DC C.T. SECONDARY - 1 AMP CT. CASE SIZE - 1-1/2D VERT. 10T CONTACTS (S/R OR H/R) - 2 N/O S/R FLAG - YES FREQUENCY - 50 HZ MOUNTING - FLUSH MTA PHASE-CHAR ANGLE - 30 DEGREES TIME DELAY P/U OR D/O - 2.5 - 25 SECS. V.T/P.T SECONDARY - 110V AC External Resistor 1.3 K.OHMS Name Plate RFH9072-604 RZF9151-601 Outline Diagram MFJ013 & FJ0349 Wiring Diagram MPDZ609-01-1
GBCCUM21PF174A DEFINITE TIME REVERSE POWER RELAY Technical Specifications Relay Model No CCUM21PF174A Relay Type CCUM 21 Case Size 1 1/2D V 10T Mounting flush. Current Rating 1 Amps V.T.Secondary Volts. 110 V ac Frequency 50 Hz Torque Angle(M.T.A) I Lead 30 deg Operating Voltage 110/125V dc Contacts 2 N/O S/R Flag Yes Timing Range 6/60 sec External Resistor 1.3 K / 35W Nameplate RFH9072 604 RZF9151 601 Outline Drawing MFJ 013 Wiring Diagram MPDZ609 01-1
GBCCUM21PF175A DEFINITE TIME REVERSE POWER RELAY Technical Specifications Model No : CCUM21PF175A CCUM21 Case Size - 1-1/2D VERT. 10T Current Rating Cup unit - 1 Amp CT V.T Secondary Volts - 110 V ac Torque Angle (MTA)I Lead V- 30 Degree Frequency - 50 Hz Aux. Voltage - 110 / 125 V dc Contacts - 2 N/O S/R Flag - Yes Mounting - Flush Timing Range - 12 - 120 Secs Ext.Resistor - 1.3K Ohms 35 Watts Name Plate VTT RZF9151-601 Name Plate RFH9072-604 Outline Diagram MFJ 013 & RFJ0349 Wiring Diagram MPDZ609-01-1
CCUM21PF176A GBCCUM21PF176A DEFINITE TIME REVERSE POWER RELAY RELAY MODEL CCUM21PF176A CCUM21 AUX. CURRENT OR VOLTAGE 110/125V DC C.T. SECONDARY 1 AMP CT. CASE SIZE 1-1/2D VERT. 10T CONTACTS (S/R OR H/R) 1 N/O 1 N/C S/R FLAG YES FREQUENCY 50 HZ MOUNTING FLUSH MTA PHASE-CHAR ANGLE 30 DEGREES TIME DELAY P/U OR D/O 0.5 - 5 SECS. V.T/P.T SECONDARY 110V AC EXTERNAL REST 1.3 K.OHMS NAME PLATE-1 RFH9072-604 NAME PLATE-2 RZF9151-601 OUTLINE DRAWING MFJ013 & FJ0349 WIRING DIAGRAM MPDZ609-01-2
GBCCUM21PF177A DEFINITE TIME REVERSE POWER RELAY RELAY MODEL CCUM21PF177A CCUM21 AUX. CURRENT OR VOLTAGE 110/125V DC C.T. SECONDARY 1 AMP CT. CASE SIZE 1-1/2D VERT. 10T CONTACTS (S/R OR H/R) 1 N/O 1 N/C S/R FLAG YES FREQUENCY 50 HZ MOUNTING FLUSH MTA PHASE-CHAR ANGLE 30 DEGREES TIME DELAY P/U OR D/O 1 - 10 SECS. V.T/P.T SECONDARY 110V AC EXTERNAL REST 1.3 K.OHMS NAME PLATE-1 RFH9072-604 NAME PLATE-2 RZF9151-601 OUTLINE DRAWING MFJ013 & FJ0349 WIRING DIAGRAM MPDZ609-01-2
GBCCUM21PF181A DEFINITE TIME REVERSE POWER RELAY RELAY MODEL CCUM21PF181A CCUM21 AUX. CURRENT OR VOLTAGE 220/230V DC C.T. SECONDARY 5 AMP C.T. CASE SIZE 1-1/2D VERT. 10T CONTACTS (S/R OR H/R) 2 N/O S/R FLAG YES FREQUENCY 50 HZ MOUNTING FLUSH MTA PHASE-CHAR ANGLE 30 DEGREES TIME DELAY P/U OR D/O 0.5 - 5 SECS. V.T/P.T SECONDARY 110V AC EXTERNAL REST 3.3 K.OHMS NAME PLATE-1 RFH9072-604 NAME PLATE-2 RZF9151-601 OUTLINE DRAWING MFJ013 & FJ0349 WIRING DIAGRAM MPDZ609-01-1