'ALSTOM' Protection Relay
MODEL NO:- P94VP16A7C0540A;
Advanced Transformer Protection, Control and Condition Monitoring Transformers are high capital cost assets in electrical power systems. Internal faults are a risk for all transformers, with short-circuits dissipating the highest localised energy. Unless cleared quickly, the possibility of rewinding will diminish and core damage may become irreparable.The MiCOM Agile P642, P643 and P645 address all these issues - preserving service life and offering fast protection for transformer faults. A transient bias technique has been included, enhancing relay stability and CT requirements. CT saturation and no gap detection techniques have been included to improve the low set differential element operating time during CT saturation where the second harmonic blocking might be asserted. An external fault detection algorithm has been incorporated to prevent the CT saturation and no gap detection from affecting the second harmonic blocking .
AFR arc flash protective relay is a costeffective solution that reduces arc-fault damage by detecting the light from an arc flash and rapidly tripping in low-voltage (LV) and medium-voltage (MV) electrical networks. three remote light sensors can be connected to one relay. It used to limits damages to equipment, improve safety, avoid and protect personnel injuries. It's also can be used as a stand-alone arc protection relay or applied in more complex switchgear layouts.
PW336i(6*15A,4*150V)is a powerful secondary injection relay tester with 6-currents and 4-voltages sources.This advanced relay testing set is capable of testing differential relay easily without changing cable connection.Optional upgrade is available to support the test of IEC61850 relay. Features 6*15A, 4*150V Aux DC (0-300V), DC measuring inputs 8 binary inputs, 4 binary outputs Adjustable threshold (0-400V) for binary inputs In-built analog monitoring and recording function Can be upgraded to support the test of IEC61850 complied relay
PW466i (6*20A, 6*150V) is a powerful secondary injection test set with 6-currents and 6-voltages sources.This advanced secondary injection kit is capable of testing differential relay and synchronizing relay. Optional upgrade is available to support the test of IEC61850 relay. Features 6*20A, 6*150V Aux DC (0-300V) 8 binary inputs, 4 binary outputs Adjustable threshold (0-400V) for binary inputs In-built analog monitoring and recording function Can be upgraded to support the test of IEC61850 complied relay
PW460 (6*15A, 4*300V) is the 3 phase relay test equipment can test all types of protective relays.This relay test kit has in-built output monitoring and recording function and also supports testing kit IEC 61850 IED.Optional accessories include external amplifier,GPS,Circuit Breaker Simulator,Current Booster,etc. Features 6*15A, 4*300V Aux DC (0-300V), DC measuring inputs 8 binary inputs, 8 binary outputs Adjustable threshold (0-400V) for binary inputs In-built analog monitoring and recording function Can be upgraded to support the test of IEC61850 complied relay
Manufacturer:Omron Product category:General purpose relays Rohs:Rohs compliant Coil voltage:24 vdc Contact form:Spdt (1 form c) Contact current rating:16 a Mounting style:Through hole Coil resistance:1.44 kohms Coil current:16.7 ma Contact material:Silver alloy (ag) Brand:Omron electronics Height:15.7 mm Length:29 mm Packaging:Bulk Power consumption:400 mw Qualification:Commercial Series:G2rl-1 Factory pack quantity:100 Width:12.7 mm Search:
Product nameï¼?3 Phase Relay Product Typeï¼?DPA53 Usageï¼?Protective Sizeï¼?Subminiature Protect Featureï¼?Sealed Contact Loadï¼?High Power Theoryï¼?Voltage Relay DPA53 series monitor for ultra-thin (17.5mm) rail mounting type, function: phase failure protection, phase sequence protection, voltage unbalance protection, adjustable set value undervoltage protection. It is suitable for the protection of the distribution system installed in the cabinet. I. Overview DPA53 series three-phase relays for three-phase or three-phase four-wire power supply for the monitor. This series of products measuring their own supply voltage, regenerative voltage, with phase sequence protection, lack of protection, undervoltage protection and other functions, N-type products with zero line disconnection protection. DPA53 series monitor for the ultra-thin (17.5mm) rail mounting type, suitable for installation of the cabinet to install the power distribution system protection, such as: distribution cabinet, distribution box, electric control box, machine tools and other equipment. Second, the input rated voltage: 200 ~ 240vAC ± 15% (line voltage) Model: DPA53CM23 320 ~ 480VAC ± 15% (line voltage) Model: DPA53CM48 115 ~ 138VAC ± 15% (phase voltage) Model: DPA53AM23N 220 ~ 277VAC ± 15% (phase voltage) Model: DPA53AM48N Phase sequence monitoring: When the three-phase power monitor power, such as the phase sequence is normal, the relay can pull. Phase loss monitoring: When the three-phase power monitor power, each phase power is normal, the relay can pull. Undervoltage protection: When the three-phase power supply line voltage is lower than the set value, then the relay release protection; when the voltage recovery, the relay back to work properly. N line disconnection protection: DPA53AM23N and DPA53AM48N is suitable for three-phase four-wire system power monitor, the two products in the N line when the relay release.
Test-630 is a six phase current output and six phase voltage output protection relay tester with 5.Eight pairs of binary input and four pairs of binary output FEATURES Integration in the host crystal 8.4 inches true color, light weight and easy to carry. Built-in high-speed and high-performance industrial computer embedded operating system, running stable and reliable, also can test by connecting PC. Panel embedded user-friendly buttons, and the panel can also be an external keyboard and mouse. High-precision DAC to 12 Road, simultaneously output to ensure the high precision and good linearity of the waveform. 5Matching electromagnetic compatibility components, can improve on-site anti-electromagnetic interference, protection devices can connect the electromagnetic compatibility to test. Analog output of the front panel, switch the amount of terminal design in the upper cover, all the wiring does not affect the operation of the panels and the test parameters of the surveillance. The latest thermal structure design to ensure the best ventilation. Automatically determine over current, over voltage, overload and short circuit, if the temperature is too high, the anomalies and misuse warning of the data will show up promptly. Using voltage, current amplifier AC / DC sharing, output stage uses a unique ultra-linear amplifier technology, high precision and reliability. six-phase AC output voltage and six-phase AC current. 12 analog ports and other optional auxiliary DC source output (220V/110V). Interface: RJ45 (Ethernet interface), USB interface (software upgrades, reporting transmission), industrial serial interface (GPS or other serial device use). TEST ITEM U/I Test DC Test Impedance Characteristics Power Direction Test I-T Test Differential Relay Harmonic Test Differential Protection Distance Protection Zero Sequence Protection Setting Group Test State Sequence Synchronization Test Special Test Oscillation Test Metering Instrument Hardware Checkout Low Voltage Protection Fault Recurrence
Supplier: Japanese quality switchgear components, breakers, magnetic contactors, switches, pilot lights, pushbuttons, panel instrumentations, power management meter, protection relays, transformers, inverters, ups.
Overview The three-phase microcomputer relay control tester has a 4-phase voltage 3 phase current output, which is suitable for various types of relay protection devices. The microcomputer relay control tester uses a high-speed high-performance digital signal processor comparative speed, transmission frequency bandwidth, and software application bifurcation algorithm produces each of the respective high-precision waveforms. Due to the integrated structure, each part is closely coupled, the data transmission distance is short, and the structure is compact. Technical parameter: AC current output Output accuracy Level 0.5 Phase current output (effective value) 0 40A Three merge current output (effective value) 0 120A Phase electric length time allows work value (effective value) 10A Phase current maximum output power 420VA Maximum output power at the maximum output of three 1000VA Working time is allowed when the maximum output of the three mesh is output 10s Frequency range (foundation) 20 1000Hz Harmonic number 1 20 times DC current output Output accuracy Level 0.5 Current output 0 10A / each phase, 0 20A / two superimposed Maximum output load voltage 20V AC voltage output Output accuracy Level 0.5 Phase voltage output (effective value) 0120V Line voltage output (effective value) 0210V Maximum voltage output value 0240V Phase voltage / line voltage output power 80VA /100VA Frequency range (fundamental) 201000Hz Harmonics 1 20 times