GBCDG11AF012SCCH IDMT OVER CURRENT RELAY Technical Specifications Relay Model No CDG11AF012SCCH Relay type CDG 11 Case size 1D V 10T Application O/C Current setting 0.5 to 2 amps Frequency 50 Hz Contacts 2 N/O 2 N/C H/R Output contacts 2 N/O 2 N/C H/R Taps Std Burden 3 VA Operating time 1.3 Secs C.T.Secondary 1 amps Flag Yes Mounting Flush Name Plate RFG9125 771 Outline Diagram MFJ 012 Wiring Diagram MADZ802.64-1
Ginger (Zingiber Officinale) is a commodity that is highly valued in international markets for its aroma, pungency and high oil and Aleo resin content. Nigeria is the third largest exporter of ginger in the world after China and India. Most of the dried ginger that are available for international trade are simply sun dried over a few days, but artificial drying is also used in areas lacking a defined dry season to coincide with the harvest. The rhizome is dried to 10-12 percent moisture content. Dried ginger is usually presented in a split or sliced form. Splitting is said to be preferred to slicing, as slicing loses more flavor, but the sliced are easier to grind and this is the predominant form of dried ginger currently in the market
ALSTOM GBCDG21AF117ZMCH IDMT OVER CURRENT RELAY WITH HIGH SET Relay Model No. CDG21AF117ZMCH Relay Type CDG21 Size 1D V 10T Current Setting 2.5 to 10 Amps Frequency 50 Hz Application O/C Contacts 3 N/O S/R Output Contacts 2 N/O S/R Taps Std C.T. Secondary 5 Amps Burden 3 VA Operating Time 3 Sec High-set Contacts 2 N/O S/R High-set Cur. Setting O/C 5 to 40 Amps High-set CAG 17 Nameplate RFG9126 674 Outline Arrangement MFJ 012 Wiring Diagram MADZ821.31
Divanti Group generates large volume of iCORE and Core 2 Duo Laptops monthly. Each lot is separated by either iCORE Laptops or Dual Core/Core 2 Duo Laptops. Our approximate order ranges from 100-300 units on average. If you are interested in purchasing laptops in bulk, feel free to send me your email address and I can send over current stock lists that is available. Thank you.
Available stock in Rotterdam tank farm for jet fuel A1: CI DIP AND PAY FOB PROCEDURE 1. Buyer sends ICPO, Company Profile along with current and valid TSA company registration certificate+ buyer passport number + company profile to seller on receipt of seller's soft corporate offer. 2. Seller issues commercial invoice of the product in tanks at the port of Rotterdam and returns commercial invoice. 3.seller will provide the Proof of Product (PPOP) documents for product verification Which include Tank Storage Receipt (TSR) Certificate of origin Statement of Product Availability, Authorization to Verify (ATV), and Dip Test Authorization (DTA) Letter. 4.After successful verification of the PPOP, the buyer will contact the seller's Tank Storage Company to request a 1-day payment invoice to enable Buyer obtain all the necessary authorization and clearance for a Dip Test schedule. *Or* Buyer must have a minimum of 10 days TSR to avoid one day tank extension. 5.Upon a successful Dip Test conducted in the seller's tanks, the buyer will make the payment for the total product cost based on the SGS Report via MT103. The seller will transfer title ownership to the buyer and send all exportation documents. The buyer can then either transfer the product into a vessel or take over the seller's tanks for further storage. 6. Upon a successful Dip Test conducted in the seller's tanks, the buyer will make the payment for the total product cost based on the SGS Report via MT103. The seller will transfer title ownership to the buyer and send all exportation documents. The buyer can then either transfer the product into a vessel or take over the seller's tanks for further storage. 7. All intermediaries involved in the transaction will sign a Non- Circumvention, Non-Disclosure Agreement (NCNDA) and International Master Fee Protection Agreement (IMFPA). These documents will be forwarded to the seller for endorsement, and the seller will provide the Endorsed NCNDA/IMFPA and Authorization to Sell and Collect (ATSC).
CI DIP AND PAY FOB TTT Rotterdam PROCEDURE 1. Buyer sends ICPO, Company Profile along with current and valid TSA company registration certificate+ buyer passport number + company profile to seller on receipt of seller's soft corporate offer. 2. Seller issues commercial invoice of the product in tanks at the port of Rotterdam and returns commercial invoice. 3.seller will provide the Proof of Product (PPOP) documents for product verification Which include Tank Storage Receipt (TSR) Certificate of origin Statement of Product Availability, Authorization to Verify (ATV), and Dip Test Authorization (DTA) Letter. 4.After successful verification of the PPOP, the buyer will contact the seller's Tank Storage Company to request a 1-day payment invoice to enable Buyer obtain all the necessary authorization and clearance for a Dip Test schedule. *Or* Buyer must have a minimum of 10 days TSR to avoid one day tank extension. 5.Upon a successful Dip Test conducted in the seller's tanks, the buyer will make the payment for the total product cost based on the SGS Report via MT103. The seller will transfer title ownership to the buyer and send all exportation documents. The buyer can then either transfer the product into a vessel or take over the seller's tanks for further storage. 6. Upon a successful Dip Test conducted in the seller's tanks, the buyer will make the payment for the total product cost based on the SGS Report via MT103. The seller will transfer title ownership to the buyer and send all exportation documents. The buyer can then either transfer the product into a vessel or take over the seller's tanks for further storage. 7. All intermediaries involved in the transaction will sign a Non- Circumvention, Non-Disclosure Agreement (NCNDA) and International Master Fee Protection Agreement (IMFPA). These documents will be forwarded to the seller for endorsement, and the seller will provide the Endorsed NCNDA/IMFPA and Authorization to Sell and Collect (ATSC).
ALSTOM GBCDG61EG040SGCH IDMT TWO O/C & ONE E/F RELAY WITH HIGH-S Relay Technical specification Relay model no CDG61EG040SGCH Relay type CDG 61 Case size 3D HOR. Application 2 O/C & 1 E/F Current setting - O/C 2.5 to 10 amps Aux.Contacts With Flag 3M S/R Output contacts 2M S/R C.T.Secondary 5 amps Frequency 50 Hz Burden 3 VA Operating time 1.3 secs Current setting - E/F 0.5 to 2 amps High set - O/C Setting 20 to 80 amps High set - E/F Setting 5 to 20 amps High set conts.With flag CAG 13 / 2M S/R Name plate RFG9125 903 Outline drawing MFJ 014 Wiring diagram MADZ 821.27-1
ALSTOM GBCDG61EG041SGCH IDMT TWO O/C & ONE E/F RELAY WITH HIGH-S Technical specification Relay model no CDG61EG041SGCH Relay type CDG 61 Case size 3D H 30T Application 2 O/C & 1 E/F Current setting - O/C 2.5 to 10 amps Contacts / Output contacts 3M S/R / 2M S/R C.T.Secondary 5 amps Frequency 50 Hz Burden 3 VA Operating time 3 secs Current setting - E/F 0.5 to 2 amps High set - O/C Setting 20 to 80 amps High set - E/F Setting 5 to 20 amps High set CAG 13 Name plate RFG9126 903 Outline drawing MFJ 014 Wiring diagram MADZ 821.27-1
GBCDG61EG042SHCH IDMT 2 O/C & 1 E/F RELAY WITH HIGH SET Technical specification Relay model no- CDG61EG042SHCH Relay type - CDG 61 Case size - 3D H 30T Application - 2 O/C & 1 E/F Current setting - O/C - 0.5 to 2 amps Contacts - 2M2B H/R 2M S/R Output contacts - 2M2B H/R 2M S/R C.T.Secondary - 1 amps Frequency - 50 Hz Burden - 3 VA Operating time - 3 secs Current setting - E/F - 0.2 to 0.8 amps High set - O/C Setting- 4 to 16 amps High set - E/F Setting - 1 to 4 amps High set - CAG 13 Name plate - RFG9126 902 Outline drawing - MFJ 014 Wiring diagram - MADZ 821.29-1
GBCDG61EG044SHCH IDMT 3 O/C RELAY WITH HIGH SET CAG 13 Technical specification Relay model no - CDG61EG044SHCH Relay type - CDG 61 Case size - 3D H 30T Application - 3 O/C Current setting - 0.5 to 2 amps Contacts / Output contacts - 2 N/O 2 N/C H/R C.T.Secondary - 1 amps Frequency - 50 Hz Burden - 3 VA Operating time - 3 secs High set - O/C Setting - 4 to 16 amps High set - CAG 13 High set contacts - 2 N/O S/R Name plate - RFG9126 771 Outline drawing - MFJ 014 Wiring diagram - MADZ 821.29-1
GBCDG61EG046SGCH IDMT TWO O/C & ONE E/F RELAY WITH HIGH-S Technical specification Relay model no - CDG61EG046SGCH Relay type - CDG 61 Case size - 3D H 30T Application - 2 O/C & 1 E/F Current setting O/C- 2.5 to 10 amps Contacts / Output contacts 3M S/R / 2M S/R C.T.Secondary - 5 amps Frequency - 50 Hz Burden - 3 VA Operating time - 3 secs Current setting - E/F - 1 to 4 amps High set - O/C Setting- 25 to 100 amps High set - E/F Setting- 10 to 40 amps High set - CAG 13 Name plate - RFG9126 904 Outline drawing - MFJ 014 Wiring diagram - MADZ 821.27-1
GBCDG61EG054SGCH IDMT 3 O/C OR 2O/C& 1 E/F RELAY WITH HI Technical specification Relay model no - CDG61EG054SGCH Relay type - CDG 61 Case size - 3D H 30T Application - 2 O/C & 1 E/F Current setting - O/C - 0.5 to 2 amps Contacts - 3 N/O S/R Output contacts - 2 N/O S/R C.T.Secondary - 1 amps Frequency - 50 Hz Burden / Operating time - 3 VA / 1.3 secs Current setting - E/F 0.2 to 0.8 amps High set - O/C setting 4 to 16 amps High set - E/F setting 2 to 8 amps High set CAG 13 Name plate RFG9125 902 Outline drawing MFJ 014 Wiring diagram - MADZ 821.27-1
GBCDG61EG057SGCH IDMT 3 O/C OR 2O/C& 1 E/F RELAY WITH HI Technical specification Relay model no - CDG61EG057SGCH Relay type - CDG 61 Case size - 3D HOR. Application - 2 O/C & 1 E/F Current setting - O/C 0.5 to 2 amps Contacts 3 N/O S/R Output contacts 2 N/O S/R C.T.Secondary 1 amps Frequency 50 Hz Burden / Operating time 3 VA / 3 secs Current setting - E/F 0.2 to 0.8 amps High set - O/C setting 4 to 16 amps High set - E/F setting 1 to 4 amps High set CAG 13 Name plate RFG9126 902 Outline drawing MFJ 014 Wiring diagram MADZ 821.27-1
GBCDG61EG058SGCH IDMT 3 O/C OR 2O/C& 1 E/F RELAY WITH HI Technical specification Relay model no - CDG61EG058SGCH Relay type CDG 61 Case size - 3D H 30T Application - 2 O/C & 1 E/F Current setting - O/C - 2.5 to 10 amps Contacts - 3 N/O S/R Output contacts - 2 N/O S/R C.T.Secondary - 5 amps Frequency - 50 Hz Burden / Taps - 3 VA / Std Operating time - 1.3 Secs Current setting - E/F - 0.5 to 2 amps High set - O/C Setting - 25 to 100 amps High set - E/F Setting - 10 to 40 amps High set / High set cont. - CAG 13 / 2 N/O S/R Name plate - RFG9125 903 Outline drawing - MFJ 014 Wiring diagram - MADZ 821.27-1
Gbcdg61eg101zmch Idmt 3 O/c or 2o/c& 1 E/f Relay With Hi Model No : Cdg61eg101zm(M) Cdg61/cag17(Mrk-iii) Application - 3 O/c Burden / D.m.t - 3 Va / 3 Sec. C.t. Secondary - 5 Amp C.t. Case Size - 3d Horz. Contacts (S/r or H/r) - 2 N/o S/r Flag - Yes Frequency - 50 Hz High Set Type - Cag17 Highset Contacts - 2m S/r Highset O/c Setting - 12.5 - 100 Amps. Mounting - Flush O/c Setting - 2.5 - 10 Amps. Name Plate - Rfg9126 774 Outline Diagram - Mfj 014 Wiring Diagram - Madz821.31
Gbcdg61eg101znch Idmt 3 O/c or 2o/c& 1 E/f Relay With Hi Model No : Cdg61eg101zn(M) Cdg61/cag17(Mrk-iii) Application - 3 O/c Burden / D.m.t - 3 Va / 3 Sec. C.t. Secondary - 5 Amp C.t. Case Size - 3d Horz. Contacts (S/r or H/r) - 2 N/o 2 N/c H/r Flag - Yes Frequency - 50 Hz High Set Type - Cag17 Highset Contacts - 2m S/r Highset O/c Setting - 12.5 - 100 Amps. Mounting - Flush O/c or O/v Setting - 2.5 - 10 Amps. Name Plate Rfg9126 774 Outline Diagram Mfj 014 Wiring Diagram Madz821.32
GBCDG61EG101ZRCH IDMT 3 O/C OR 2O/C& 1 E/F RELAY WITH HI Technical Specification Model No - CDG61EG101ZRCH Relay Type - CDG61/CAG17(MRK-III) Application - 2 O/C + 1 E/F Case Size - 3D Horz C.T. Secondary - 5 Amp C.T. O/C Setting - 2.5 - 10 Amps. E/F Setting - 0.5 - 2 Amps Contacts - 2 N/O S/R Flag - Yes Frequency - 50 Hz Burden / D.M.T - 3 Va / 3 Sec High Set Type / Conts. - CAG17 / 2 N/O S/R Highset O/C Setting - 12.5 - 100 Amps. HighSet E/F Setting - 5 - 40 Amps Mounting - Flush Name Plate - RFG9126 903 Outline Diagram - MFJ 014 Wiring Diagram - MADZ821.31
GBCDG61EG101ZSCH IDMT 3 O/C OR 2O/C& 1 E/F RELAY WITH HI TECHNICAL SPECIFICATION Model No - CDG61EG101ZSCH CDG61/CAG17(MRK-III) Application - 2 O/C + 1 E/F Case Size - 3D Horz C.T. Secondary - 5 Amps O/C Setting - 2.5 - 10 Amps. Frequency / Tap - 50 HZ / Std Burden / D.M.T - 3 Va / 3 Sec Contacts - 2 N/O 2 N/C H/R E/F Setting - 0.5 - 2 Amps. Flag - Yes High Set Type / Contacts - CAG17 / 2 N/O S/R HighSet E/F Setting - 5 - 40 Amps HighSet O/C Setting - 12.5 - 100 Amps. Mounting - Flush Name Plate - RFG9126 903 Outline Diagram - MFJ 014 Wiring Diagram - MADZ821.32
GBCDG61EG102ZMCH IDMT 3 O/C OR 2O/C& 1 E/F RELAY WITH HI Model No : CDG61EG102ZMCH CDG61/CAG17(MRK-III) APPLICATION - 3 O/C BURDEN - 3 VA C.T. SECONDARY - 1 AMP CT. CASE SIZE - 3D HORZ. CONTACTS (S/R OR H/R) - 2 N/O S/R D.M.T - 3 SEC. FLAG - YES FREQUENCY - 50 HZ HIGH SET TYPE - CAG17 HIGHSET CONTACTS - 2M S/R HIGHSET O/C SETTING - 2.5 - 20 Amps. MOUNTING - FLUSH O/C SETTING - 0.5 - 2 Amps. Name Plate RFG9126 771 Outline drawing MFJ 014 Wiring Diagram MADZ821.31
This unit sense current for over current or earth fault protections, 1kg, height 105mm base 102 * 51mm