Air filter Unit
Model Aw2000-02 Aw3000-03 Aw4000-04 Aw4000-06 Aw5000-10 Working medium Air Pressure range 0.05~0.85mpa Max working pressure 1.0mpa Test pressure 1.5mpa Operating ambient temperature 5-60 degree celsius Recommended lubricant Iso vg 32 or equivalent Port size G 1/4 G3/8 G1/2 G3/4 G1
Our products are exported to many countries and we have been committed to product perfection for many years. We accept OEM customization from customers, and customers can also sell our brands. Become our agent. Looking forward to your inquiry and participation. We will give you the best price, please contact me if necessary.
A suitable solution for. Airborne substances, viruses and other fine particles in the nanoscale range are filtered out of the air with a separation efficiency of 99.995 % and the activated charcoal filter also removes odours. The integrated CO2 sensor alerts you should additional ventilation be required.
Our products are exported to many countries and we have been committed to product perfection for many years. We accept OEM customization from customers, and customers can also sell our brands. Become our agent. Looking forward to your inquiry and participation. We will give you the best price, please contact me if necessary.
Clean air equipment, such as fume hoods, air purifiers, and HEPA filters, ensures a safe and contaminant-free environment in labs. These devices help remove harmful particles, gases, and fumes, protecting both the samples and the researchers.
Pre filter, fine filter, pocket filter, compressor air intake filter, diesel generator air intake filter, ceiling filter, high temperature oven filters, paint arrestance filter, roll-o-matic filter, press filter, paint filter, powder coating cartridge filters, hepa filters, minim pleat hepa filters, high temperature filters, fan filter units, hood type hepa filters, carbon filters, laminar flow work stations, air showers, dispensing / sampling booth, soft wall modular clean room, garment room, air curtains, pass box, operation theater hepa plenum boxes, air handling units, hepa filter terminal box, clean room doors & windows, filter cleaning system, filter bags, filter bag cages.
Mini-pleat construction with Al frame Glass fiber media pack EN1822 U15 and U16 grade MPPS 99.9995% ~ 99.99995%
Military filter for Bunker/Shelter Nuclear, Biological, Chemical protection
QAC series air filter regulator lubricator combination units are specially designed to efficiently filter out rust, dirt, moisture and other impurities from compressed air lines. Operation is fully automatic with a minimum of pressure drop.The cost effective and clean looking QAC series allows you to pick a combination of modular style air preparation equipment that best suits your needs, without the use of pipe connectors, saving space.
Air filters for air handling units.
Gel Seal HEPA Filter, Mini Pleated HEPA Filter, Deep Pleated HEPA filter, High Temperature HEPA Filter. Grade: H13/H14
Air diffuser Feature: 1)aluminum alloy material. 2) the vane angle will be 30íp; 3) air register1-4 directions, square or rectangular for choice. 4) can add obd or fliter as your requirement. 5)easy installation and maintenance 6) natural anodized aluminum finish or powder coated Outer standard size: as per your request(face size=neck size+127mm) Neck size: a*b(size is as per your request) Vane space:25~35mm Height:50mm Flange width: 62mm Order notes: item-neck size aíßb-color/(obd/filter or not) Functions: mutil-angle for air supply or return Use: for floor, ceiling, wall, sidewall, door, air conditioner application, in broadcast room, hospital, theater, guest room Packing:normal packing (each diffuser packed with a piece of wrapper, and then put into the carton separated with a cardboard) Models Hfk-ls1a~4a
Our products are exported to many countries and we have been committed to product perfection for many years. We accept OEM customization from customers, and customers can also sell our brands. Become our agent. Looking forward to your inquiry and participation. We will give you the best price, please contact me if necessary.
***AHU(Air Handling Unit) Spec*** 1. Horizontal Type : Air Volume 3,000---84,000m3/h 2. Vertical Type : Air Volume 3,000---18,000m3/h 3. Ceiling Type : Air Volume 3,000---12,000m3/h
Air filter compressed air filter 1). Separator filter (HF9) For bulk liquid removal plus a 3 micron coalescer (5ppm w/w maximum remaining oil content) Two-stage filtration * First stage: two stainless steel orifice tubes provide 10 micron mechanical separation * Second stage: in-depth fiber media captures solid and liquid particles to 3 micron 2). Air line filter (HF7) For removal of liquid water and oil; removes solid particles to 1 micron (1.0 ppm w/w maximum remaining oil content) Corrosion resistant inner and outer cores Two-stage filtration * Firt stage: captures larger particles with alternate layers of fiber media and media screen * Second stage: coalesces aerosols and captures solid particles with multiple layers of epoxy bonded, blended fiber media 3). High efficiency oil removal filter (HF5) For coalescing fine water and oil aerosols; removes solid particles to 0.01 micron (0.01 ppm w/w maximum remaining oil content) Corrosion resistant inner and outer cores Two stage filtration * First stage: multiple layers of bonded, blended fiber media for fine coalescence * Second stage: multiple layers of bonded, blended fiber media for fine coalescence Outer coated, closed cell foam sleeve 4). Ultra high efficiency oil removal filter (HF3) For coalescing ultra-fine oil aerosols; removes solid particles to 0.01 micron (0.001 ppm w/w maximum remaining oil content) Corrosion resistant inner and outer cores Two stage filtration * First stage: coated, closed cell foam sleeve acts as pre-filter and flow disperser * Second stage: multiple layers of matrix blended fiber media for ultra-fine coalescence Outer coated, closed cell foam sleeve 5). Oil vapor removal filter (HF1) For removal of oil and hydrocarbon vapors normally absorbable by activated carbon; removes solid particles to 0.01 micron (0.003 ppm w/w maximum remaining oil content) Corrosion resistant inner and outer cores Two stage filtration * first stage: stabilized bed of finely divided carbon particles removes the majority of the oil vapor * Second stage: multiple layers of fiber media with bonded micro fine carbon particles remove the remaining oil vapor Multiple layers of fine media prevent particle migration Outer coated, closed cell foam sleeve prevents fiber migration Designed life is 1000 hours under rated conditions.