4OXV CiTiceL Oxygen Gas Sensor (O2 Sensor) Key Features and Benefits: * False alarm immunity * Enhanced response time in extreme applications * Reliably meets stated life * Superior environmental performance
Our most advanced intelligent spot detectors, multi-criteria/multi-sensor devices use multiple sensors to detect various conditions in an environment sensing a wider range of fires with greater accuracy. Features & Benefits: Multi-Criteria/Multi-Sensor smoke detection Unique ability to detect major elements of a fire Highest nuisance alarm immunity Advanced algorithms interpret and respond to multiple inputs
Honeywell BW Solo is a easy to service single-gas detector with BLE connectivity that provides real-time visibility into the status and safety of hazardous-area workers, helping companies respond faster, more knowingly and decisively to safety incidents. The first single-gas detector with the 1 Series sensor for CO, H2S and O2 Features & Benefits: User-friendly operation, Easy-to-read display for multiple languages, Lightweight convenience, Ease of maintenance, Serviceability, The new 1-Series sensor for enhanced reliability, Connected Bluetooth Low Energy (BLE) capabilities.
O2-M2 Oxygen Sensor Description Alphasense Oxygen sensors use capillary flow control. Unlike partial pressure oxygen sensors, they have good pressure and temperature dependence, making them the best choice in safety applications. Standard galavanic sensors use lead for greatest reliability but fixed lifetime. Specifications * Output: 80 to 120 uA @ 20.9% O2 * Response time t90: < 15 (s) from 20.9% to 0% O2 * Linearity: 0.6 % O2 deviation @ 10% O2 * Operating life: > 24 months *Temperature range: -30 to 55 'C * Pressure range: 80 to 120 kPa * Humidity range: 5 to 95 % rh continuous * Diameter: 20.0 mm (including label) * Heigh: 17.4 mm (including foam ring) * Weight: < 16g
Oxygen sensor o2 gas sensor for portable gas detector Model number: o2-a2 Performance Output µa @ 20.9% o2 80 to 120 Response time t90 (s) from 20.9% to 0% o2 < 15 Zero current µa in n2 < 2.5 Linearity % o2 deviation @ 10% o2 0.6 Lifetime Output drift % change in output @ 3 months < 1 Operating life months until 85% original output of 20.9% o2 > 24 Environmental Humidity sensitivity % o2 change: 0% to 95% rh @ 40°c < 0.7 Co2 sensitivity % (change o2 reading) / % co2 @ 5% co2 0.1 Pressure sensitivity (% change of output)/(% change of pressure) @ 20kpa < 0.1 Key specifications Temperature range °c -30 to 55 Pressure range kpa 80 to 120 Humidity range % rh continuous (0 to 99% rh short term) 5 to 95 Storage period months @ 3 to 20°c (store in sealed pot, open circuit) 6 Load resistor o (recommended) 47 to 100 Diameter mm (including label) 20.0 Height mm (including foam ring) 17.4 Weight g < 16
optical oxygen sensor O2 Gas sensor LOX-02 Description The LuminOx Family is a range of factory calibrated optical sensors which measure ambient O2levels using the principle of fluorescence quenching by oxygen. Our unique patented process allows us to produce an oxygen sensor that benefits from low power, traditionally associated with electrochemical sensing devices, while providing a much longer lifetime due to the non-depleting sensing principle. Applications Typical applications for the Cheap Price Oxygen Sensor LOX-02 are; Oxygen detection Portable equipment Breathing apparatus Inerting Medical Lab equipment Agriculture Incubation Fore prevention Flue gas in condensing boilers
With a Freestyle Libre Sensor you can continuously measure your blood sugar for 14 days. Attaching the sensor using the sensor applicator is well described in the instructions for use. When attaching the sensor, a small, 5mm long, flexible cannula is placed under the skin (usually painless). The sensor is worn on the back of the upper arm and continuously measures your glucose levels. It is waterproof and can be worn while bathing, showering or swimming. If you set up additional optional alarms, you will be warned in good time about hypoglycemia, for example, and can therefore feel even safer - day and night.
Gillette Fusion5 men's razor blade refills each have 5 precision blades spaced closer together (vs. Mach3) for less feel of irritation and incredible comfort. Each blade refill also has a Precision Trimmer on the back, great for edging tough areas such as under the nose and sideburns. One razor blade refill equals up to one month of shaves. These Fusion5 blade refills can be used with any Fusion5 razor handle. Features include: 5 precision blades, helping reduce pressure per blade for a comfortable shave (vs. Mach3) Precision Trimmer on back great for edging tough areas (nose and sideburns) 1 razor blade refill equals up to one month of shaves Fits with any Fusion5 blade refills
Wireless charger, batteries power bank, dust sensor, optical disc drive, tof, lidar, ar glass.
Commodity:Sodium persulfate Molecular Formula : Na2S2O8 Molecular weight : 238.13 Description Sodium persulfate is a white,crystalline,odourless salt.It is used as initiator for the Polymerization of monomers and as a strong oxidizing agent in many applications.It has the particular advantage of being almost non - hygroscopic,of having a particularly good storage stability as a result of its extremely high purity and of being easy and safe to handle. Transportation Road/Rail transport : GGVS,GGVE,ADR,RID/CLASS 5.1 Sea transport : GGV Sea/IMDG code : CLASS 5.1 Page 5185,UN no.1505 Water hazards class 1(slight water hazard) All information is given in good faith,but without warranty,since the conditions of use are outside our control. Verification by the user is recommended.Freedom from patent restriction cannot be assumed. Package (1) In 25kgs net multiple paper bags with one PE bag inner (2) In 25kgs net PE bags (3) In 25kgs net woven bags with two PE bags inner (4) In 1000kgs net big woven bags with one PE bag inner The above package is also with a pallet 1000kgs each. Storage NPS(SPS) is not combustible but assists combustion materials due to release of oxygen.Provided it is stored under appropriate condition.It must be stored dry in closed containers and protected from direct sunlight,heat and humidity.Impurities such as dirt,rust or traces of metal and reductants may cause catalytic decomposition.The product as supplied or in solution needs to be handled with appropriate care.The eye,skin and clothes must be protected when working with NPS(SPS) as damp powder or aqueous solution has a bleaching and slightly corroding effect. Application Polymerization : Initiator for the emulsion or solution Polymerization of acrylic monomers,vinyl acetate,vinyl chloride etc.and for the emulsion co-polymerization of styrene,acrylonitrile,butadiene etc. Metal treatment : Treatment of metal surfaces(e.g. in the manufacture of semiconductors; cleaning and etching of printed circuits),activation of copper and aluminium surfaces. Cosmetics : Essential component of bleaching formulations. Paper : modification of starch,repulping of wet - strength paper. Textile : Desizing agent and bleach activator - particularly for cold bleaching.(i.e.bleaching of Jeans). Others : - Chemical synthesis - Water treatment(decontamination) - Waste gas treatment,oxidative degradation of harmful substances(e.g.Hg) - Disinfectant ITEMS SPECIFICATIONS Appearance white crystalline salt Assay 99.0% w/w min Active oxygen 6.65% w/w min Chloride and chlorate(as CL) 0.005% w/w max Ammonia (NH4) 0.05% w/w max Manganese(Mn) 0.0001% w/w max Iron(Fe) 0.001% w/w max Heavy metals(as Pb) 0.001% w/w max Moisture 0.05% w/w max Decomposition of the product as supplied at above 65C Recommended storage temperature Normal Temperature Storage stability as from date of delivery 12 months
Features * oxygen pressure range 2 mbar - 3bar * zirconium dioxide (zro2 ) sensing elements * non-consumption technology * integral heating element * no need for temperature stabilisation * no reference gas required * high accuracy * linear output signal * operates with external interface boards Specifications Heater voltage: Porous cap (15mm): 4.35v dc +/- 0.1v dc (1.85a) Stand by: 2v dc (0.85a) Pump resistance @ 700'C: < 6kOhm Permissible gas temperature: -100 to 250C Gas flow rate: 0 to 10 m/s Repetitive permissible acceleration: 5 g Incidental permissible acceleration: 30 g
O2-a2 oxygen sensor Performance Output î¼a @ 20.9% o2 80 to 120 Response time t90 (s) from 20.9% to 0% o2 < 15 Zero current î¼a in n2 < 2.5 Linearity % o2 deviation @ 10% o2 0.6 Lifetime Output drift % change in output @ 3 months < 1 Operating life months until 85% original output of 20.9% o2 > 24 Environmental Humidity sensitivity % o2 change: 0% to 95% rh @ 40â?? < 0.7 Co sensitivity % (change o2 reading) / % co2 @ 5% co2 0.1 Pressure sensitivity (% change of output)/(% change of pressure) @ 20kpa < 0.1 Key specifications Temperature range â?? -30 to 55 Pressure range kpa 80 to 120 Humidity range % rh non-condensing (0 to 99% rh short term) 5 to 95 Storage period months @ 3 to 20â?? (store in sealed pot, open circuit) 6 Load resistor î© (recommended) 47 to 100 Diameter mm (including label) 20.0 Height mm (including foam ring) 17.4 Weight g < 16 -
NX1 CiTiceL Nitric Oxide Sensor (NO Sensor) Key Features & Benefits: * Designed for Automotive Applications * Fast Response
4nd citicel nitrogen dioxide sensor key features & benefits , industry leading reliability , improved performance variability 4nd citicel nitrogen dioxide sensor application Industrial safety: sensors for portable gas detectors used in industrial hygiene and confined space entry. 4nd citicel nitrogen dioxide sensor performance characteristics , nominal range: 0-20 ppm , expected operating life: two years in air , output signal: 0.6 , ± 0.15 ua/ppm , resolution: 0.1 ppm , repeatability:
Zirconia O2 Sensors Probe Series - Short Housing The Probe Range of zirconium dioxide oxygen sensors are available in three lengths. Suitable for aggressive and polluted applications such as boiler exhausts. Longer probes are an ideal solution for thicker walled, insulated flue pipes. FEATURES * Zirconium dioxide (ZrO2) sensing elements * Long life, non-depleting technology * Integral heating element * High accuracy * Requires an external interface board to operate BENEFITS * No reference gas required * No need for temperature stabilisation * Compact enclosure TECHNICAL SPECIFICATIONS Heater voltage Operating (standard response) 4V DC ± 0.1V DC (1.7A) Standby 1.65V DC (0.7A) Operating (fast response) 4.35V DC ± 0.1V DC (1.85A) Standby 2V DC (0.85A) Pump impedance at 700'C < 6kΩ Permissible gas temperature -100'C to +250'C Gas flow rate 0 ~ 10 m/s Repetitive permissible acceleration 5g Incidental permissible acceleration 30g OUTPUT VALUES Oxygen pressure range 2mbar ~ 3bar max Accuracy 5mbar max Internal operational temperature 700'C Response time (10 - 90% step) Standard response sensor < 15s Fast response sensor < 4s Warm up time (prior to sensor operation) 60s Warm up time (from standby) 20s Output stabilisation time ~ 180s
Zirconia O2 Sensors Probe Series - Long Housing FEATURES * Zirconium dioxide (ZrO2) sensing elements * Long life, non-depleting technology * Integral heating element * High accuracy * Requires an external interface board to operate BENEFITS * No reference gas required * No need for temperature stabilisation * Two lengths available; 220mm and 400mm TECHNICAL SPECIFICATIONS Heater voltage Operating 4V DC ± 0.1V DC (1.7A) Standby 1.65V DC (0.7A) Pump impedance at 700'C < 6kohm Permissible gas temperature Standard temperature -100'C to +250'C High temperature -100'C to +400'C Gas flow rate 0 - 10 m/s Repetitive permissible acceleration 5g Incidental permissible acceleration 30g OUTPUT VALUES Oxygen pressure range 2mbar - 3bar max Accuracy 5 mbar max Internal operational temperature 700'C Response time (10 - 90% step) < 15s Warm up time (prior to sensor operation) 100s Warm up time (from stand by) 20s Output stabilisation time ~ 180s
FEATURES * Oxygen pressure range 2 mbar - 3bar * Zirconium dioxide (ZrO2 ) sensing elements * Non-consumption technology * Integral heating element * No need for temperature stabilisation * No reference gas required * High accuracy * Linear output signal * Operates with external interface boards SPECIFICATIONS Heater Voltage Porous Cap (15mm) 4.35V DC ± 0.1V DC (1.85A) Stand by 2V DC (0.85A) Pump resistance @ 700'C < 6k� Permissible gas temperature -100 to 250'C Gas flow rate 0 to 10 m/s Repetitive permissible acceleration 5 g Incidental permissible acceleration 30 g z
Thank you for purchasing and using our company's ultrasonic oxygen concentration / flow sensor. 1, please carefully read the instructions and fully understand the contents of the sensor after operation and maintenance. Improper use may cause damage to the sensor. (no violent impact and falling ground) 2, without the consent of the company, it is strictly prohibited to alter the structure and components of the sensor without authorization. The company is not responsible for any personal safety incidents or sensor abnormalities caused by unauthorized alterations. 3, the specifications and instruction contents of this sensor may be changed due to the technical improvement of the product. 4, this instruction manual must be handed to the actual user of the sensor and stored in it, and placed at any time where the actual user of the sensor can access it. 5, the company has the right to interpret the instructions for the sensor. 2ã??technical parameter Measurement parameters measuring method range Resolution accuracy O2 Ultrasonic 20.5%-95.6% 0.1% �±1.8%FS 5-45â?? Note: the range can be customized according to customer requirements. Sample gas requirements Water removal (no condensation); dust filtration (
Features * oxygen pressure range 2 mbar - 3bar * zirconium dioxide (zro2 ) sensing elements * non-consumption technology * integral heating element * no need for temperature stabilisation * no reference gas required * high accuracy * linear output signal * operates with external interface boards * pcb mountable Specifications Heater supply* Porous lid cap 4vdc +/- 0.1vdc (1.7a) Stand by 1.65vdc (0.7a) Full porous cap 4.35v dc +/- 0.1v dc (1.85a) Stand by 2v dc (0.85a)