1. Only two weighing steps, the purity% of precious metals and gold karat can be tested rapidly and accurately. 2. No stains and scratches left on your gold after testing, it doesní»t need to use the sulfuric acid solution to test the standard samples. 3. It can easily judge the alloys with the metallic-membrane plating of more than 30ª¦m thickness. 4. With the special software design, it can directly and circularly show the gold karat (including gold-copper-silver, gold-silver, gold-copper), gold purity%(including gold-copper-silver, gold-silver, gold-copper) 5. With the function of high limit and low limit, the wide karat range from 9K to 24K and the data of HI and LO can be set freely. 6. With the mixture proportion function, it can test other precious metals, such as: platinum, silver, palladium, copper, rhodiumí¡.and so on 7. It has the RS-232C interface, can easily connect to the PC and the printer. 8. It adopts design of tank (the maximum dimension of the sample is D100í-W70í-H25mm for solid measuring), this can decrease the inaccuracy caused by supporting wireí»s buoyancy. 9. Can't test the samples inlaid precious stones and hollow samples. It can be used as general balance.
This model of weighing indicator adopts plastic case, wiht good quality and powerful functions. It has weighing function, counting function, accumulation fuction and check weighing function. Real time o?lock and RS232 interface Auto calibration Low power detect, charging status indication Approval model with 3000 Up to 30000 display resolution Simple counting Check, management weigh Auto switch on off Hold function
Lightweight construction, total weight for a 18 x 3m weighbridge approx. 11.000 kg, including drive on/off ramps. Heaviest component weighs approx. 1000 kg.Easy to transport by small capacity truck. Easy and fast (0, 5 to 1 day) installation/relocation by means of a small forklift without necessity for cranes and other heavy equipment. No need for special foundations, can be installed on any, reasonable horizontal, concrete or asphalt surface, surface must be able to carry fully loaded truck Only 300 mm high.Unique modular design by means 3 basic modules, being: weighing modules, floor modules and ramp modules. All parts, including load cells and mounts, remain easily accessible after installation, guaranteeing uncomplicated maintenance Dimensions 6x3m 9x3m 12x3m 16x3m 18x3m
Many kinds available
Dynamic balancing machine. Packed in plywood box
Oxidation coated rod Extenden Length: 90mm - 1200mm Stroke: 20mm - 700mm Rod Dia: 06,08,10, Tube Dia: 15,18,21,22 mm Min.Order Quantity: 10.000 pcs 100 - 50 - 25 pcs per carton box according sizes.
QS30 is designed for highest precision determining the capacitance and dielectric dissipation factor tanª- of liquid and solid insulants, cables, capacitors, line transformers, generators, motors, bushings etc. Furthermore, it can also be used for power loss measurement on shunt reactors or similar apparatus. The system performs Semi-Automatic measurement of Dissipation Factor (tanª-) & Power Factor (cosª+) and Capacitance. Ití»s designed to help you modernize your testing facility at an affordable price and, ití»s simple to operate. We can also provide the professional solutions and equipments for: withstanding voltage testing, c & tan-delta (power factor) testing, partial discharge (PD) testing and impulse voltage testing.
Size:- 0.8mx0.8mx110mm 1mx1mx110m 1.2mx1.2mx110m 1.2mx1.5mx110m 1.5mx1.5mx110m 1.5mx2mx110m 2mx2mx110m 1.5mx3mx140m 2mx3mx140m Max weighing capacity 05t,1t,2t,3t,5t,8t,10t *Suitable for weighing of hoisting material, forklift and manual handling *Not suitable for weighing of mini vehicle carried cargo and also application with pit style installation.
Fe 70 % min, silica less 2 % Loose
1.Manufactured by OEM of MT 2.Light self weight, higher strength, fair in style and apply to open fair and light industrial area well. Stretching cover is optional for dimension. Carton Dimension, wooden pallet.
1. Manufatured by oem of mt 2. Combined with serried channel steel girder formed a higher strength and reliable platform scale. Low height design make load and unload by forklift convenient. Carton dimension, iron pallet.
Mechanical counter scale pain body. 4 scale in one box with export packing.
Rechargeable accumulator, You can use the scale durng rechargng Auto zero--settng when swtch on the scale Auto zero--tracng. Swtch among weghng, countng, percentum. Functon of choosng weght range. Workng temperature range:0½+40 Dvson accuracy Jcs-03b 3kg30000/150000.1g/0.2g Jcs-06b 6kg30000/150000.2g/0.5g Jcs-15b 15kg30000/150000.5g/1g Jcs-30b 30kg30000/15000 1g/2g
technical specifications Standard Lot Size , Weight , Dimensions
Length of platform:6m,8m,10m,12m,14m,16m,18m,20m. Width of platform:3m,3.2m Capacity:30t,40t,50t,60t,70t,80t,100t. Sea-worthy packing.
Technical indexes Accuracy class: Rated capacities: 10, 15, 20, 30, 40, 50, 60, 70, 80, 100 and 120t Widths of platform: 2, 2.2, 2.5, 3 and 3.2m Lengths of platform: 4, 5, 6, 7, 8, 9, 10, 12, 14, 15, 16 and 18m Foundation form: no foundation pt and shallow foundation pt Counts: 3000 (note: counts maximum capacty/dvson) Overload lmt: 125% Platform operating temp.(ncludng sensor) :-30 +65 Operating humpty rh: 20-85%. Sea-worthy packng.
PB series anti-corrosion and explosion-proof over ground scale employs the new-designed steel structure equipped with high precision weighing sensor and intelligent weighing meter. Features: Fast calculation, high accuracy, stable and reliable operation; Four high precision stainless sensors; Original safety and recombination-type explosion-proof equipments; High anticorrosion and waterproof performance.
DCS-B explosion-proof truck scale, designed and produced by our company, obtained the explosion-proof certificate of conformity issued by china national quality supervision and test center for explosion protected electronic product. The whole machine including balance body, sensor and meter can be used in hazardous areas containing explosive gas and dust. User should choose the right electronic scale and relevant parts according to area explosion class. DCS explosion-proof truck scale mainly consists of platform (full steel structure or ferroconcrete), explosion-proof sensor, junction box, shielded cable, power supply, weighing meter, printer and pc weighing software. Weighing process: The platform of explosion-proof truck scale is installed on the base of hazardous area, and other parts like weighing meter is usually installed in safety room. The truck proceeds to platform at the speed of 3~5km/h. During weighing, software performs data processing and storage, and then printer prints out the relevant info. Sea-worthy packing.
Model SCS/ZCS-H ferroconcrete platform tuck scale. Technical indexes Accuracy class: iii Rated capacities: 10, 15, 20, 30, 40, 50, 60, 70, 80, 100 and 120t Widths of platform: 2, 2.2, 2.5, 3 and 3.2m Lengths of platform: 4, 5, 6, 7, 8, 9, 10, 12, 14, 15, 16 and 18m Foundation form: no foundation pit and shallow foundation pit Counts: 3000 (note: counts=maximum capacity/division) Overload limit: 125% Platform operating temp. (including sensor) :-30 - +65 Operating humidity rh: 20-85%. Sea-worthy packing.
A. Machine - Miracle NC8107 MACHINE - RENISHAW UCC Lite-2 Control System -Calibrate Ball with Support Base - User and System Manuals B. Computer System - Minimum configuration: Pentium ó(3.0 GHz/512MB RAM/80GB Hard Disk/32MB Graphic Card /17ísColor LCD Monitor/ Windowí»s OS - HP Color DeskJet printer C. Software System -American Rational DMIS software (for Windows XP)(Named Open DMIS out China ) D. RENISHAW Probe System 1Set - Renishaw MH8 Manual indexing Probe Head -TP20 probe - Renishaw Probe Styli Kit Miracle NC8107 Performance Specifications Measuring Strokes : 800(mm) x1000(mm) x700(mm) Overall Dimension : 1700(mm) x 2150(mm) x3000 (mm) Max part weight : 400 kg Resolution : 0.2(m) Accuracy according GB/T16857.2-1997 equal ISO 10 360ú¦ (Volumetric length measuring error) E =2.9 +4.0L/1000 m (Volumetric Probing Error) R = 3.0 m Environment Specifications Room required specifications - Average room temperature: 18 - 22 ípC - Maximum thermal gradients:1 ípC/hourú¼2 ípC/dayú¼1 ípC/mú¼ - Air supply system - (Min. air pressure) : 0.7 MPa - (Min. air consumption) : 0.1 m3/min Electrical requirements - (Voltage) : 220 Vac 10% - (Frequency) : 50 Hz - (Current) : 10 A Allowed Maximum Floor Vibration - (Frequency Range): 0 19 Hz 1975 Hz > 75 Hz - (Maximum Amplitude): 0.0011 mm 0.00110.002 mm 0.002 mm 2.2m*1.9m*2.1m