A. Machine
- Miracle NC8107 MACHINE
- RENISHAW UCC Lite-2 Control System
-Calibrate Ball with Support Base
- User and System Manuals
B. Computer System
- Minimum configuration: Pentium ó(3.0 GHz/512MB RAM/80GB Hard Disk/32MB Graphic Card /17ísColor LCD Monitor/ Windowí»s OS
- HP Color DeskJet printer
C. Software System
-American Rational DMIS software (for Windows XP)(Named Open DMIS out China )
D. RENISHAW Probe System 1Set
- Renishaw MH8 Manual indexing Probe Head
-TP20 probe
- Renishaw Probe Styli Kit
Miracle NC8107 Performance Specifications
Measuring Strokes : 800(mm) x1000(mm) x700(mm)
Overall Dimension : 1700(mm) x 2150(mm) x3000 (mm)
Max part weight : 400 kg
Resolution : 0.2(m)
Accuracy according GB/T16857.2-1997 equal ISO 10 360ú¦
(Volumetric length measuring error) E =2.9 +4.0L/1000 m
(Volumetric Probing Error) R = 3.0 m
Environment Specifications
Room required specifications
- Average room temperature: 18 - 22 ípC
- Maximum thermal gradients:1 ípC/hourú¼2 ípC/dayú¼1 ípC/mú¼
- Air supply system
- (Min. air pressure) : 0.7 MPa
- (Min. air consumption) : 0.1 m3/min
Electrical requirements
- (Voltage) : 220 Vac 10%
- (Frequency) : 50 Hz
- (Current) : 10 A
Allowed Maximum Floor Vibration
- (Frequency Range): 0 19 Hz 1975 Hz > 75 Hz
- (Maximum Amplitude): 0.0011 mm 0.00110.002 mm 0.002 mm
2.2m*1.9m*2.1m
Supplier: CMM, coordinate measuring machine, laser scanner.
Services: Upgrade of coordinate measurement machine