A computer-controlled machine used during an eye examination to provide an objective measurement of a person's refractive error and prescription for glasses or contact lenses. This is achieved by measuring how light is changed as it enters a person's eye.
Infuses Fluids, Medication Or Nutrients Into A Patient's Circulatory System. It Is Generally Used Intravenously
Ventilation Mode: IPPV. A/C, PCV , SIMV, Spont/CPAP, PSV, Sigh, Manu Ventilator Parameter Tidal volume:0, 20- 2000 rnL (Vt. Frequency (Freq):1 min - 100 min Oxygen concentration: 21 % - 100 % I:E:4 : 1 -- 1:8 PEEP:0 cmH2O 40 cmH2O Pressure limit: 20 cmH2O -100 cmH20 Pressure triggering sensitivity(Ptr): -20 cmH2O - 0 cmH2O(Based on PEEP) Flow triggering sensitivity (Ftr): 0.5 cmH2O - 30 cmHz0 SIGH: 0 (off) 1/100 - 5/100 Apnea ventilation: OFF, 5s - 60s MONITORING PARAMETER Frequency (Freq): 0/min - 100/min Tidal volume (Vt): 0mL - 2500mL MV: 0 lUmln - 99 Umin Airway pressure: 0 cmH2O - 100 cmH2O Dynamic lung compliance monitoring:1mL cmH2O - 1000 mL/cmH2O Oxygen concentration: 15 % - 100 % ALARM & PROTECTION AC power failure alarm: Power failure or no connection Internal backup backup battery low voltage alarm:
For Indwelling Needle Catheter, Central Venus Catheter & Epidural Catheter Fixed.
For Nasogastric Tube , Oxygen Tube & Stomach Tube
Endotracheal & Duct Fixed
FDA/CE
FDA/CE
Purity:93% ±3%@5L Power supply:320 VA Flow:1-5L Noise:48dB Output Pressure:30-70 kPa Size:38*32.5*59 cm Certificate:CE/ISO13485 Compressor:GSE Molecular sift:CECA Instrument classification:Class II Warranty:2 years After-sale Service:Free spare parts
Water tank Capacity 3.5L Airflow rate 300ml/h Voltage 100~240V 50Hz/60Hz Power 28W Mist maker heads 1pcs Size 210*190*380mm Carton packaging Size 250*240*430mm G.W. 1.8kg Control way Remote control Applying area About 30m3 MOQ 100pcs
Water tank 6 L Airflow rate 350ml/h Voltage 100~240V 50Hz/60Hz Power 28W Mist maker heads 1pcs Size 220*220*580mm Carton packaging Size 625*250*255mm G.W. 2.2kg Function water lack protecting UV light/timing /low noise /water lack protecting Control way Romot control & Maunal control Maunal control Applying area About 40m3 MOQ 100pcs
Adult, Children & Infants 12.1inch Touchscreen VT Control System, Apply Lung Compliance Function Non Invasive Ventilation Flow & Pressure Trigger Autowash For Exhaust Valve
PiCPC/CVC Catheter Fixed
8x42cm
FDA/CE
FDA/CE
8.4'/10.4'/12.1' high resolution industry color TFT LCD screen. Basic 7 standard parameters: ECG, NIBP, SpO2, RESP, 2-Temp, PR/HR. 5 lead, max 7 ECG wave forms display. Optional Futures: Touch screen WIFI 5AH lithium battery 2IBP ETCO2 Central monitoring system
10.1 inch touch screen; Fast Test and Easy to Use; Realtime data exchange; Superior accurate test result; Rechargeable lithium battery backup for 5 hours. Standard configuration: 12 lead ECG/NIBP/Infrared forehead TEMP/SPO2/URT (Urine Routine)/GLU (Blood Glucose)/UA (Uric Acid)/TCHO (Total Cholesterol)/Hemoglobin/Backpack.Handheld Monitor 10.1 inch touch screen; Fast Test and Easy to Use; Realtime data exchange; Superior accurate test result; Rechargeable lithium battery backup for 5 hours. Standard configuration: 12 lead ECG/NIBP/Infrared forehead TEMP/SPO2/URT (Urine Routine)/GLU (Blood Glucose)/UA (Uric Acid)/TCHO (Total Cholesterol)/Hemoglobin/Backpack. Optional configuration: Blood Lipid (TG, LDL-C, HDL-C, TCHO):
Water tank 24L Airflow rate 2000ml/h Voltage 100~240V 50Hz/60Hz Power 110W Mist maker heads 4pcs Size 365*315*740mm Carton packaging Size 317*267*1120mm G.W. 7kg Control way Romot control & Manual control Applying area About 200m3 MOQ 100pcs
Electronic Flow Meter With Mechanical System Adult,Pediatric & Infants Automatic Compensation Function For VT 12.1inch Touchscreen Real Time Detection Loops, PAW, BPM, VT & Compliance Comprehensive Ventilation Modes: VCV, PCV, PSV, A/C , SIMV-P, SIMV-V. Breathing Loops With Zoom In/Out , Freeze & Comparison 72hrs Trend Record with 3000logs