Thyroid Function 0.05-80IU/ml Serum/Plasma/Whole blood 15Min.
Ventilator YH-830 bi-level PAP device CE certification and FDA certificate FOB Price USD 6.100/ Set Stock 300 units in stock today Payment term: T/T in advance. Delivery immediately after payment Technical parameters of YH-830 bi-level PAP device 1. Scope of application: For adult patients with ARDS, hypoventilation syndrome, for bi-level non-invasive ventilation in a hospital or home. 2. the main function: 1. Different treatment options can be provided according to patients' needs, from CPAP to S, T, S / T, VGPS five modes 2. Adjustable trigger sensitivity. 3. Real-time monitoring and recording of blood oxygen saturation. 4. alarm function. 5. Record function (SD card). 6. Maximum leak compensation function. 60L/min 7. With trolley, easy to move in the hospital 3. the key technical parameters: 1. Working mode: CPAP, S, T, ST, VGPS. 2. Ventilation parameters: 2.1 Inspiratory pressure: 4-30 cmH2O (0.5 cmH2O interval) 2.2 Expiratory pressure: 4-30 cmH2O (0.5 cmH2O interval) 2.3 Treatment pressure: 4-20 cmH2O (in CPAP mode, 0.5 cmH2O interval) 2.4 Delayed boost: 0-45 minutes (interval of 5 minutes) 2.5 Breathing frequency: 5-50 times / minute (interval 1 time / minute) 2.6 Breathing ratio: 10-70% (interval of 1%) 2.7 Rise time: 1-5 steps (1 step interval, 1 step rises fastest, 5 steps rises most slowly) 2.8 Inhalation sensitivity: 1-5 steps (1 step interval, 1st step triggers fastest, 5th step 1st step triggers slowest) 2.9 Exhalation sensitivity: 1-5 (1 interval, the 1st trigger is the fastest, 5th and 1st the slowest) 2.10 Tidal volume: 50-1500ml (effective in VGPS mode, interval 50ml) 3.VGPSï¼?same with AVAPS, can set Target tidal volumeï¼? 3.1 Maximum IPAP value adjustable range: 4-30 cmH2O 3.2 Adjustable range of minimum IPAP value: 4-30 cmH2O 3.3 EPAP value adjustable range: 4-30 cmH2O 3.4 Target Tidal Volume: 50-1500ml 4. Display range of monitoring setting parameters: 4.1 Respiratory waveform can be displayed; 4.2 Current mode: CPAP, S, T, ST, VGPS 4.3 Inspiratory pressure: 4-30 cmH2O 4.4 Expiratory pressure: 4-30 cmH2O 4.5 Breathing frequency: 5-50 times / minute 4.6 Breathing ratio: 10-70% 4.7 Air leakage: 20-99.9lpm 4.8 Tidal volume: 50-1500ml 4.9 minute ventilation: 0-50lpm 4.10 Blood oxygen saturation: 70-100% 4.11 Pulse rate: 25-250bpm 4.12 Delay boost: 0-45 minutes 6.Specifications 6.1 Weight: about 20kg including the trolley and the device 6.2 Operating temperature: 5-35 C 6.3 Relative humidity: 10% -90% 6.4 Power supply: input is AC 100-240V, 50-60Hz, 1.8A Max; output: DC 24V, 3.33A.
All type of medical equipments.
Test strips and medical equipment.
Laryngoscopes
Perforator 01
Medical instruments.
Medical equipments.
Medical equipment.
Medical equipments.
Health care, hospital medical equipments, engineering.
Plastic scraps, Medical equipments.
Medical Equipment.
Face masks and medical equipments.
Medical & surgical items.
Laboratory, hospital & educational equipment.
Medical/laboratory/industrial items.
Otoscopes, laryngoscope, medical instruments, all sizes of disposable speculas, otoscopes, opthalomoscope, ent diagnostic sets, dental instruments..
Medical equipments and supplies (used and new).Sourcing agents
Used medical equipment and disposable medical supplies.