The insulators testing device HVTS-HP is designed for testing the insulation of power cables and solid dielectric with the rectified voltage of up to 100 kV, as well as testing solid dielectrics with the sinusoidal voltage of up to 100 kV, 50 Hz. The main difference between series devices Cable test and diagnosis system HVTS-HP devices from Portable Hi pot Tester HVTS-70/50 is the increased power output. There are two standard versions: 7.5 KVA and 17.5 KVA.
SWG-12 Mobile Cable Test and Fault Location System - is a complex solution for safe, fast and easy locating a faulty place on low and medium underground voltage cables. It includes a powerful high-voltage unit, which has a test, burn and surge generation modules, and a time-domain reflectometer for locating faults on cables. Main features: - Suitable for portable application - Easy to operate - Multiple fault location methods included - 10.4 High-contrast color TDR display - Improved convenience for operator - Heavy duty The high-voltage unit of the system provides with high-power up to 1100 Joules surges at 3; 6 and 12 kV ranges. At each range, the output voltage is smoothly adjustable. The rate of surge waves can be smoothly adjusted. The single manual shot option is also included. The DC output mode is provided for quick fault diagnostics. The 100 mA burn mode is available. Digital Impulse Reflectometer (TDR) provides you with 10.4-inch bright high-contrast TFT display with touchscreen. The 800 Ã? 600 pixels resolution makes the picture sharp. The touchscreen allows an operator navigate through the menu fast and easy. An alternative way of navigation is included. It is provided with a control knob. Reflectometer RIF-9 integrates a multiple ways of fault prelocation. It can be used either as a standalone device in TDR mode or in a conjunction with HVmodule, working in arc reflection mode. Reflectometer RIF-9 has USB interface. The package content includes software for PC (optional), which allows working with saved reflectograms. The firmware can be easily updated through USB interface by inserting a flash drive.
VLF-60 Cable Insulation Tester by KEP is a very low frequency high potential tester that ensures efficient testing and fault location on medium voltage cables. Testing principle Very low frequency (VLF) testing involves applying frequency in the range of 0.01 to 0.1 Hz to the cable under test, which is non-destructive to insulation of proper quality, but is enough to detect cable faults. Compared to DC cable testing, which can be damaging to good insulation, VLF testing does not have such a detrimental effect on the cable being tested and does not generate any travelling waves. Main features Efficient non-destructive cable withstand testing Portable, perfect for field testing Fully automatic testing cycle Automatic discharging Easy maintenance due to solid-type insulation system Breakdown voltage measurement and load recognition Easy-to-use software Does not need an external PC LCD touch screen
Luminaires are used for lightning of: Outdoor and indoor lightning facilities with emergency (reserve) lightning Housing of luminaires is made of aluminum alloy. ptics borosilicate glass or polycarbonate. Luminaires have anti-vandal protection. Different types of mounting allow to install luminaires without improvement of the existing mounting attachments.
- Voltage 6000V - Voltage 10000V - Voltage 6000/3000V - Voltage 6000/10000V - Voltage 6300, 6600V - Voltage 380.
Direct current motors.
Electro motor power from 90 w to 180 w, single-phase, capacitor. The power from 90 to 180 kw, operating voltage 220 v, motor connecting points (shaft outlet, shaft configuration, motor mounting holes) are determined individually with the customer. Also we can complete the engine with a thermal relay. The minimum . The minimum lot for delivery is from 100pcs up to 500pcs.
"The stylish floor lamp of the directed light will provide illumination for any space, big or small. They are easy to move, so you can make any place a little more comfortable. This modern floor lamp will complement and decorate any interior"
Low prices! We can produce for you site. Quickly and efficiently. Order from us a sieve! Standard Lot Size
For automatic and mechanized welding and surfacing of carbon and low alloy structural steels. Shielding gas types: carbon dioxide, argon and mixtures of carbon dioxide and argon, submerged arc welding. Coil 1 - 15 kg, diameter from 0.8-2.0 mm, EN ISO 14341:2020 Wire grades Sv-08G2S and Sv-08GS are used in shipbuilding, car building, boiler building, installation work, construction for welding metal structures, the automotive industry, and agricultural engineering. Chemical composition, % (steel grade Sv-08G2S) Manganese: 1.80-2.10; Carbon: 0.05-0.11; Silicon: 0.70-0.95; Chrome, no more: 0.2; Nickel, no more: 0.25; Sulfur, no more: 0.025; Phosphorus, no more: 0.03.
- Automatic and power control relays - Time relays - Relays and protector and alarms of single-phase circuits on ground in circuits 6-10 kV - Relay protection and automatics - Phase control relays, isolation and pulsation - Electromagnetic relays.
Heating area - up to 3 sq.m. Weight - 3 kg Dimensions - 750mm x 130mm x 14mm Power consumption - 157 Watt Manufacturer Warranty - 5 years Electric skirting panels warm up walls and help eliminate mold, fungus, moisture, and condensate in rooms that usually have cold corners or cold external walls. Heating such a room with an ordinary oil-filled radiator, electric water boiler, or electric fan heater will not solve the problem. Three different models of UDEN-S skirting panel heaters range between 100W, 150W, and 200W in power capacity. They can be used not only as a stand-alone heating system but also combined with other UDEN-S heaters for efficient heating and a comfortable feeling in the room. Beautifully designed, our skirting panel heaters are only 13cm in height and only 14 mm in thickness. They come in white color as standard but a customer can order any color from our rich palette (over 100 colors and shades) that will match the customer's interior.
Heating area - up to 4 sq.m. Weight - 3.5 kg Dimensions - 998mm x 130mm x 14mm Power consumption - 200 Watt Manufacturer Warranty - 5 years Electric skirting panels warm up walls and help eliminate mold, fungus, moisture and condensate in rooms that usually have cold corners or cold external walls. Heating such a room with an ordinary oil filled radiator, electric water boiler, or electric fan heater will not solve the problem. Three different models of UDEN-S skirting panel heaters range between 100W, 150W, and 200W in power capacity. They can be used not only as a stand-alone heating system but also combined with other UDEN-S heaters for efficient heating and comfortable feeling in the room. Beautifully designed, our skirting panel heaters are only 13cm in height and only 14 mm in thickness. They come in white colour as standard but a customer can order any colour from our rich palette (over 100 colours and shades) that will match the customer's interior.
Flexible WC connector reinforced. Lenght: 330/558/830 mm.
Automatic circuit breaker tester UPA-3 is designed for testing and ampere-second characterization of automatic AC current circuit breakers. The device allows registering the value of the supplied current and timing the automatic circuit breaker switching interval. Circuit breaker tester UPA-3 is a mobile device, which could be easily transported to a required testing location. Circuit breaker tester UPA-3 operates on the principle of varying the power in the primary circuit of the matching power transformer and, respectively, varying the output current, flowing through the automatic circuit breaker under the test. Power regulation could be done either through an external regulator (RNO or VR) or through a built-in thyristor controller.
We offer Royal Kraft RK9500W gnerators, 3-phase, 3,5kW. Technical data: Power supply: 230V/50Hz 3 phases Engine: 4-stroke with air cooling 3x sockets 230V 1x12V 1x400V Engine power: 5.2kW/7km Nominal power: 3.5kW Maximum power: 3.8kW Voltage regulator: Yes Start: manual Voltmeter: Yes Fuel level sensor: yes 12V output: yes Fuel tank capacity: 15 l (approximately 12 hours per tank) Fuel: 95 or 98 unleaded gasoline Materials: stainless steel, copper, aluminum, plastic The generator is equipped with shock absorbers. Weight: 39 kg
The sensor temperature measuring of the steel equipment or axle bearing is designed to measure the temperature of axle boxes with the transferring data to wagon controller. The temperature sensor is attached directly to the axle box cover with a bolted connection. The power element of the temperature measuring sensor is a built -in battery. Fastening type bolted joint; Range of working temperatures 40 + 85 C Range of measured temperatures 40 + 125 Accuracy of temperature measurement 0.5 Frequency plan EU433 ; The period of communication is adjusted; Type of antenna built-in ; Sensitivity -114 dBm ; Radio communication range in the tunnel up to 100 m ; Transmitter output power up to 20 mW ; Built-in battery capacity 2700 mAh ; Continuous battery life p to 2 years ; Dimensions, mm not more than 119 x 32 x 32 ; Weight, g, not more than 300 ; Total service life, years, not less than 10 ; The operating mode is long ; Dust and water protection rating IP65.
Generator set for factories and enterprises with the need for autonomous power supply of more than 2000 kWt. (Gas piston unit of container design, power over 2.5 MW) Model: MTU 20V4000 GS Fuel: natural gas Manufacturer: "mtu A Rolls-Royce solution" Working principle: piston engine Condition: new Detailed specifications will be sent as a PDF file in messengers or by e-mail. In the presence of 5 pcs., geographically located in Turkey, ready to provide fast delivery to any city
Maximum active power - 4.8 kW; Maximum power consumption - 7.4 kVA; Voltage regulation range in MIG mode - 13-23.5 V; MIG welding wire nominal diameter - 0.6-1.0 mm; Maximum diameter of MIG filler wire - 1.2mm; Welding wire type - copper-plated / flux-cored; Wire feed speed - 2.5-13 m / min; Diameter of wire spools to be installed up to - 200 mm; Current regulation range in MMA mode - 20-160 A; Welding electrode diameter - 1.6-4 mm; Modes of operation MIG - 2T / 4T / Spot time; Machine duty cycle at maximum MIG current - 60% (25�ºC) / 25% (40�ºC); Duty cycle of the apparatus at maximum current MMA - 100% (25�ºC) / 60% (40�ºC); Efficiency - 93%; Hot start - yes; Anti stick - yes; Arc force - yes; Open circuit voltage - 65 V. Number of power transistors - 6; Nominal mains voltage - 230 ± 10% V; Current frequency - 50/60 Hz.
Maximum active power - 3.9 kW; Maximum power consumption - 6.6 kVA; Voltage regulation range in MIG mode - 13-22 V; MIG filler wire nominal diameter - 0.8-0.9 mm; Max.MIG filler wire diameter - 1.0mm; Welding wire type - copper-plated / flux-cored; Wire feed speed - 1.5-9 m / min; Diameter of wire spools to be installed up to - 200 mm; Current regulation range in MMA mode - 20-140 A; Modes of operation MIG - 2T / 4T / Spot time; Machine duty cycle at maximum MIG current - 60% (25�ºC) / 20% (40�ºC); Duty cycle of the apparatus at maximum current MMA - 100% (25�ºC) / 60% (40�ºC); Efficiency - 93%; Hot start - yes; Anti stick - yes; Arc force - yes; Open circuit voltage - 65 V; Number of power transistors - 4; Nominal mains voltage - 230 ± 10% V; Current frequency - 50/60 Hz.