JET A-1 is an aviation fuel formerly known as kerosene which is suitable for most jet aircraft. It meets stringent international requirements, particularly those of the latest versions of the AFQRJOS, the British DEF STAN 91-91 standard, the ASTM D1655 standard, and the NATO F-35 specification. It has a minimum flashpoint of 38C and a maximum freezing point of -47C. JET A-1 is the principal fuel used for jet turbine engines. It is also used in general aviation for compatible diesel engine planes. Jet fuel or aviation turbine fuel (ATF) is a type of aviation fuel designed for use in aircraft powered by gas-turbine engines. It is colourless to straw-colored in appearance. The most commonly used fuels for commercial aviation are Jet A and Jet A-1, which are produced to a standardized international specification. The only other jet fuel commonly used in civilian turbine-engine powered aviation is Jet B, which is used for its enhanced cold-weather performance. Jet fuel is a mixture of a large number of different hydrocarbons. The range of their sizes (molecular weights or carbon numbers) is restricted by the requirements for the product, for example, the freezing point or smoke point. Kerosene-type jet fuel (including Jet A and Jet A-1) has a carbon number distribution between about 8 and 16 (carbon atoms per molecule); wide-cut or naphtha-type jet fuel (including Jet B), between about 5 and 15.
Universal input pid process controller With smart i/o module system - 4 digits process (pv) and 4 digits process set (sv) display - universal process input (tc, rtd, mvz , vz , maz) - optional secondary sensor input - dual or multi point calibration For zvoltage / current input - configurable on/off, p, pi, pd and Pid control forms - adaptation of pid coefficients to the system With auto-tune and self-tune - manual/automatic mode selection For control outputs - bumpless transfer - smart i/o module system - programmable heating, cooling and Alarm functions for control outputs - motorized valve control function - 8 steps profile control ( ramp & soak ) function And start-hold-stop by using logic input module - remote set point function by using analogue input modules - retransmission of process value or process control By using 0/4...20 maz current output module - detection of heater failure by using 0...5a vct input . Module - hardware configuration by using input/output modules - rs-232 (standard) or rs-485 (optional) serial communication with modbus rtu protocol Application fields applications Glass motorized valve control Plastic profile control Petro-chemistry pid process control Textile heater failure detection Automative Machine production industries
Specifications; O way and works on window and wall - banks - public buildings - schools - turnstile and barriers
SSR, 0-10v- P, PI, PD, PID Or ON/OFF Hysteresis Control, Selectable Sensor Input (J type (Fe-Const), K type (NiCr-Ni), Pt100, R type (PtRh13Pt), S type (PtRh10Pt), T type (Cu-Const) ).
Proximity access controller Proximity Standalone Access Controler less then 500 user
Prosthetics Like Prosthetic Scanners Prosthetic Micromotors.
EN590 was introduced to coincide with the development of new emissions standards across the European Union. The overall goal has been to reduce the sulphur content of diesel fuel. Sulphur had been used as a lubricant in the fuel. Its role is taken by special additives in ULSD. Since 2007, diesel that conforms to EN590 has been referred to as Ultra Low Sulphur Diesel (ULSD) in the European Union. The phrase Ultra Low Sulphur Diesel is governed by different standards in other parts of the world. EN590 describes the physical properties that all automotive diesel fuel must meet if it is to be sold in the European Union, Croatia, Iceland, Norway and Switzerland. The EN 590 had been introduced along with the European emission standards. With each of its revisions the EN 590 had been adapted to lower the sulphur content of diesel fuel since 2007 this is called ultra low sulphur diesel as the former function of sulphur as a lubricant is absent (and needs to be replaced by additives). The quality of European diesel fuels is specified by the EN 590 standard. While these specifications not are mandatory, they are observed by all fuel suppliers in Europe. Automobile diesel en 590 is intended for application in diesel engines. Diesel motor fuel quality meets the requirements of European Standard EN 590. For operation in the conditions of a temperate climate following marks of fuel diesel automobile EN 590 are offered: Grade C limiting filterability temperature -5 C; Grade D limiting filterability temperature -10 C; Grade E limiting filterability temperature 15 C; Grade F limiting filterability temperature -20 C. The entire volume of produced diesel fuel quality meets the requirements for fuels for vehicles of Euro 4 and Euro 5. Low sulfur content in diesel EN 590 reduces emissions of sulfur oxides into the atmosphere, which is especially important for for inhabitants of big cities.
Urea Fertilizer 46% N GOST 2081-92 Prilled Urea (Prilled) GOST 2081-92 Nitrogen: 46.0% MIN (ON DRY BASIS) Moisture: 0.5% Max Biuret %age By Weight: 1.0% MAX Particle Size (i) Material Passing thro ugh 2.8mm IS Sieve (Tyler Sieve 7) and retained on 1mm IS Sieve (Tyler Sieve 16) by weight i) To pass through 1mm IS Sieve by weight : 90% MIN,5% MAX MELTING POINT: 132 Degrees Celsius COLOUR: Pure white RADIATION: NON-Radioactive. FREE FLOWING: 100% Treated against caking, free from harmf ul substances. PHYSICAL: PRILLED, free from harmf ul substances, impurities & dust. FREE AMMONIA: 160 PXT, PPM. MAX. UREA 46%N Agriculture grade PRILLED | GRANULAR -GRADE EXTRA- | Total nitrogen: 46.2% min. | Humidity: 0.3% max. | Biuret: 1% max. | Allowed production class: 0.85-2 mm/2-4 mm. | Formaldehyde: 0.35 - 0.55% min. | Free Ammonia: 50 ppm. | Resistance to fragmentation: 3 kg for granule with a diameter of 3.15 mm. | Temperature: Max 50 min 5 | Density: 760 to 800 kg / m3 | Appearance: white Granules. -Get your shipment from our factory DIRECTLY. -We ship Urea 46%N either in Bulk loose in shipload OR FIBC 1Mt OR 50 kg bag package of woven polymeric laminated, polyethylene bags. -Two years validity in optimal storing conditions. -ETD 8000 Mt=10 days, prices vary according to packing terms
Electronic device, circuit design and manufacture, fingerprint smartcard applications, flow computers for well management of metan gas wells, power systems of water treatment devices, pump controllers, id verification.Software application development, electronic circuit, device designing
Heating elements, hot plates, quartz heating elements, thermostats.
Temperature controllers, timers, counters, mini thermostats, defrost thermostats, analog\digital thermostats.
Hot runner systems, hot runner nozzles, hot runner manifolds, hot runner temperature controllers.
Access control systems, proximity card reader, password & card reader, passing door control system, password reader, keypad reader, access reader, card access control system, stand alone reader.
Temperature (heating and cooling) controllers, process controllers, digital counters & timers, temperature sensors.
Poultry house control panels, poultry house controllers, poultry sensor, temperature sensor, humidity sensor, pressure sensor.
Indulge in the luxurious comfort of our men's and women's bathrobe, crafted from high-quality fabric. Its plush texture offers an unparalleled level of softness, providing a snug fit that ensures both comfort and exceptional warmth. the fabric material is super soft and is still machine washable. Wash the robe in low temperature. Tumble dry low heat.
Thermostats.
Efficiently store and manage hot water for your heating system with our reliable and durable buffer tanks. Benefits: Increased Energy Efficiency: Store excess heat from your boiler or solar thermal system for later use, reducing energy consumption. Consistent Hot Water Supply: Ensure a constant supply of hot water, even during peak demand periods. Extended System Lifespan: Protect your heating system from temperature fluctuations and wear. High-Quality and Certified Materials: Built with durable and reliable components. Titanium Enamel Coating: Provides superior protection against corrosion and ensures long-lasting performance. Cathodic Protection: Enhances resistance to rust and corrosion. Built-in Thermometer: Allows for easy temperature monitoring. Technical Specifications: Volume: 50 Liters to 5,000 Liters Maximum Usable Water Temperature: 90C Test Pressure: 15 Bar Operating Pressure: 10 Bar Interior Surface Coating: Titanium Enamel Contact us today to learn more about our distributor program and offer high-quality buffer tanks to your customers!