EAC 790 Engine: CUMMNS Engine Model : KTA38-G1 Stand By kVA: 790 Stand By kW : 632 Prime kVA: 718 Prime kW : 574 Rated Current : 1033 Engine - CUMMNS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternat - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine CUMMNS Engine Model KTA38-G1 Number of Cylinders 12 - V TYPE Injection System Direct Compression Ratio 14.5:1 Bore 159 Strok 159 Displacement Lt 19 Air Intake Turbocharged, Aftercooled Speed (RPM) 1500 Oil Capacity Lt 135 Standby Power kw / Hp 701 / 953 Prime Power Hp 634 / 862 Fuel Type Euro Diesel Governor System Electronic Cooling System Water Cooling Coolant Capacity Lt 350 Fuel Consumption (lt / h) Lt Full Load 158 Lt %75 LOAD 122 Lt %50 LOAD 86 Frequency Hz Power kVA 550 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation 1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 9200 Weight (Open) Kg 8050 Width (Silent) Mm 2200 Length (Silent) Mm 6200 Height (Silent) Mm 2800 Fuel Tank Capacity Lt 1750 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 750 Engine: CUMM NS Engine Model : QSK19-G11 Stand By kVA: 740 Stand By kW : 592 Prime kVA: 672 Prime kW : 538 Rated Current : 968 Engine CUMM NS heavy duty diesel engine 12V starter and charge alternator Replaceable air, fuel and oil filters Mechanical governor control Tropical type radiator Flexible fuel hose Oil drain valve and extension hose Industrial type silencer and steel compensator Maintenance-free starter battery Water jacket heater 1500 rpm engine speed Alternat IP 21-23 Protection Standard H Insulation Class 50 Hz Frequency 4 pole brushless synchronous type alternator Automatic Voltage Regulator (AVR) 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis Convenient design for easy lifting and carrying High standard sound proof canopy design Modular design with easily removable nuts - bolts Lockable doors Transparent window for watching Control Panel Electrostatic powder painted, providing protection against harsh weather conditions Emergency STOP button Fuel tank inside the chassis Anti-vibration wedges (engine - chassis and chassis ground) Optional Thermal magnetic CB (for automatic models) Super Silent Canopy Mobile Generator Sets Automatic fuel filling system Synchronization panel 3 Pole and 4 Pole ATS (Automatic Transfer Switch) Fuel Heater, Oil Heater External fuel tank and automatic fuel filling system Fuel - water separator filter Remote monitoring and control system Engine CUMM NS Engine Model QSK19-G11 Number of Cylinders 6 - Inline Injection System Direct Compression Ratio 15.9 : 1 Bore 159 Strok 159 Displacement lt 19 Air Intake Turbo Aftercooler Speed (RPM) 1500 Oil Capacity lt 80 Standby Power kW / Hp 667 / 907 Prime Power kW / Hp 606 / 827 Fuel Type Euro Diesel Governor System Electronic Cooling System Water Cooling Coolant Capacity lt 42 Fuel Consumption (lt / h) lt Full Load 135 lt %75 LOAD 103 lt %50 LOAD 69,5 Frequency Hz 50 Power kVA 740 Voltage V 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation 1% Insulation Class H Protection Standard IP21 - IP23 Power Factor 0,8 Weight (Silent) Kg 5750 Weight (Open) Kg 4900 Width (Silent) mm 1900 Length (Silent) mm 4800 Height (Silent) mm 2700 Fuel Tank Capacity lt 1350 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnâ??t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 690 Engine: CUMM NS Engine Model : KTAA19-G6A Stand By kVA: 690 Stand By kW : 552 Prime kVA: 630 Prime kW : 505 Rated Current : 910 Engine - CUMM NS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternat - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine CUMM NS Engine Model KTAA19-G6A Number of Cylinders 6 Inline Injection System Direct Compression Ratio 13.0:1 Bore 159 Strok 159 Displacement L 19 Air Intake Turbocharged, Aftercooled Speed (RPM) 1500 Oil Capacity L 38 Standby Power kw / Hp 610 / 825 Prime Power kw / Hp 554 / 750 Fuel Type Euro Diesel Governor System Electronic Cooling System Water Cooling Coolant Capacity L 75 Fuel Consumption (lt / h) L Full Load 148,3 L %75 LOAD 112,7 L %50 LOAD 76,4 Frequency Hz Power kVA 550 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation 1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 5200 Weight (Open) Kg 4530 Width (Silent) Mm 1900 Length (Silent) Mm 4800 Height (Silent) Mm 2400 Fuel Tank Capacity L 1450 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnt permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 650 Engine: CUMMNS Engine Model : KTAA19-G6 Stand By kVA: 650 Stand By kW : 520 Prime kVA: 590 Prime kW : 472 Rated Current : 849 Engine - CUMMNS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternat - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine CUMMNS Engine Model KTAA19-G6 Number of Cylinders 6 Inline Injection System Direct Compression Ratio 13.0:1 Bore 159 Strok 159 Displacement Lt 19 Air Intake Turbocharged, Aftercooled Speed (RPM) 1500 Oil Capacity Lt 38 Standby Power kw / Hp 570 / 770 Prime Power Hp 518 / 700 Fuel Type Diesel Governor System Electronic Cooling System Water Cooling Coolant Capacity Lt 75 Fuel Consumption (lt / h) Lt Full Load 140 Lt %75 LOAD 104,9 Lt %50 LOAD 74,5 Frequency Hz Power kVA 550 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation 1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 5190 Weight (Open) Kg 4510 Width (Silent) Mm 1900 Length (Silent) Mm 4800 Height (Silent) Mm 2400 Fuel Tank Capacity Lt 1450 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnt permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 550 Engine: CUMMNS Engine Model : KTA19-G3A Stand By kVA: 550 Stand By kW : 440 Prime kVA: 500 Prime kW : 400 Rated Current : 720 Engine - CUMMNS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternat - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine CUMMNS Engine Model KTA19-G3A Number of Cylinders 6 Inline Injection System Direct Compression Ratio 13.9:1 Bore 159 Strok 159 Displacement L 19 Air Intake Turbocharged & Intercooled Speed (RPM) 1500 Oil Capacity L 38 Standby Power kw / Hp 504 / 675 Prime Power kw / Hp 448 / 600 Fuel Type Euro Diesel Governor System Electronic Cooling System Water Cooling Coolant Capacity L 75 Fuel Consumption (lt / h) L Full Load 107 L %75 LOAD 82,3 L %50 LOAD 56,4 Frequency Hz Power kVA 550 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation 1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 5085 Weight (Open) Kg 4410 Width (Silent) Mm 1900 Length (Silent) Mm 4800 Height (Silent) Mm 2400 Fuel Tank Capacity L 1450 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isnt permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAC 220 Engine: CUMM NS Engine Model : 6CTAA8.3-G2 Stand By kVA: 220 Stand By kW : 176 Prime kVA: 200 Prime kW : 160 Rated Current : 288 Engine - CUMM NS heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternat - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine CUMMNS Engine Model 6CTAA8.3-G2 Number of Cylinders 6 Inline Injection System Direct Compression Ratio 18.0:1 Bore 114 Strok 135 Displacement L 8,3 Air Intake Turbocharged Air Aftercooled Speed (RPM) 1500 Oil Capacity L 23,8 Standby Power kw / Hp 203 / 272 Prime Power kw / Hp 183 / 245 Fuel Type Euro Diesel Governor System Electronic Cooling System Water Cooling Coolant Capacity L 12,3 Fuel Consumption (lt / h) L Full Load 45 L %75 LOAD 34 L %50 LOAD 23 Frequency Hz Power kVA 220 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation 1 Insulation Class H Protection Standard IP22 - IP23 Power Factor 0,8 Weight (Silent) Kg 2190 Weight (Open) Kg 1850 Width (Silent) Mm 1200 Length (Silent) Mm 3500 Height (Silent) Mm 1850 Fuel Tank Capacity L 360 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
Structure Size : 90 - 355 Rated Power : 0.37 / 1.66 30/37 kW Pole Number : 16 / 4-12 / 4-16 / 6-8 / 4-6 / 4-12 / 6-16 / 2-4 / 2 Protection Class : IP55 (up to 280 types), IP65 (315 types and above) (Contact us for higher protection classes.) Voltage : 380 V (Contact us for different voltages.) Frequency : 50 Hz (Contact us for different frequencies and speed control devices.) Build Type : B3 (Contact us for different structure types.) Mechanical Structure : Body and covers are cast iron, legs are ductile iron Cooling Type : IC 411 (Contact us for different cooling types and for forced cooling.) Insulation Class : F / H (Contact us for different insulation classes.) Working Regime : S1 (Contact us for S2..S10 operating regimes.) Ambient temperature : 40 C (Contact us for higher ambient temperatures.) Motor Protection : Thermistor and motor protection relay for over 250 types (Applicable to smaller types.)
Structure Size : 58-63-74-81-93 / MR65-MR71-MR-80/112 Rated Power : 1.1-7.5 kW Pole Number : 2 - 4 Protection Class : IP55 Voltage : 380 V Frequency : 50 Hz Build Type : B3 Mechanical Structure : Aluminum or Iron Body Cooling Type : IC 411 Insulation Class : F Working Regime : S1, S6- 40% Ambient temperature : 40 C Motor Protection -
New Diesel And Gas Generators now available
40 kva generator sets Motor brand : ricardo Alternator brand : gentech Cylinder numbers : 40 kva ( 4 cylinders ) Rpm : 1500 Working systems : automatic The brand of control modules : datakom Fuel systems : diesel Delivery terms :exw, fca, fob istanbul or cif Warranty : international 1 year spare part warranty Quality standard certificates : ce / iso 9001 / ohsas 18001 / iso 14001 / gost-r / tse All products tha Gentech alternators have been entirely manufacturing with turkish property products in gucbir factory in turkey Datakom control panels have been entirely manufacturing with turkish property products in turkey datakom facilities. We have productions of automatic, manuel, portable generators as optional Please contact us for our competitive export prices. L:225 cm W:95 cm H:160 cm Q:1150 kgs.
3 kVA Generator Sets Motor Brand : Perkins Alternator Brand : Mecc Alte Stand by :33 kVA Prime :30 kVA Cylinder Numbers : 33 kVA ( 3 Cylinders ) Rpm : 1500 rpm. ENGINE FEATURES •Diesel engine types suitable for heavy duty •4 stroke engine,water cooled •Mechanic/Electronic governor systems •Direct injection fuel system •Replacable cylinder jackets •12/24 Volt DC •Replacable oil filter,fuel filter and dry type air filter •Cooling radiator and fan •Flexible fuel hoses and oil outlet valve •Industrial muffler and flexible expansion compensator •Starter battery (lead acid) including wire and mount •Jacket water heater (for automatic models) ALTERNATOR FEATURES •Gentech brand,made in Turkey •Brushless,mono bearing,4 polar •Isolation class H •Protection class IP 21/22/23 •Self-alarm and regulated •Electronic automatic voltage regulator •2/3 stator windings to prevent harmonic failures •Windings are imprengiated with tropic epoxy resin against oil and acid CONTROL PANEL FEATURES •The control panel of monitoring,operation and safety is mounted on generator chassis •The features of automatic control panel : •Components on the panel •DKG 307 control module to monitor complete system •Static battery charger •Emergency stop button a) The features of generator control module DKG 307/DKG 309 •Automatic generator protection and control functions •Remote control function •Analaog displays for temperature and oil pressure •CosØ and KW displays for Generator •Engine operation time-clock •Maintenance time-clock •165 programmable parameters •Battery operated real-time clock •Weekly operating timer •Daily,weekly,monthly test •Fault recorder (with date and time info) •Statistical counters •Monitoring and recording at pc via RS-232 serial data port b) Displays on LCD monitor •Generator Volt (F-N) •Generator Ampere (L1,L2,L3) •Generator Frequency (Hz) •Generator CosØ •Generator Active Power (KW) •Oil Pressure (bar) •Cooling Water Temperature (0C) •Maintenance Timer •Network Volt (F-F/F-N) •Operating time display •Battery Voltage c) Alarms on LCD monitor •Overload/Over voltage •Over speed •Low/High network voltage •Low/High Generator Frequency •Cooling Water Level •Battery Alternator or Belt Breakage •Engine Low Oil Pressure •High Engine Temperature •Low Battery Voltage •Charge Failure L:220 cm W:95 cm H:180cm Q:1550 kgs.
55 kVA Generator Sets Motor Brand : Ricardo Alternator Brand : Gentech Cylinder Numbers : 55 kVA ( 4 Cylinders ) Rpm : 1500 Working Systems : Automatic The brand of Control Modules : Datakom Fuel Systems : Diesel Delivery Terms : FOB Istanbul or CIF Warranty : International 1 year spare part warranty Quality Standard Certificates : CE / ISO 9001 / OHSAS 18001 / ISO 14001 / Gost-R / TS All products that we manufacture are in the A class quality Gentech Alternators have been entirely manufacturing with Turkish property products in Gucbir factory in Turkey Datakom Control Panels have been entirely manufacturing with Turkish property products in Turkey Datakom facilities. We have productions of Automatic,Manuel,Portable Generators as optional Please contact us for our competitive export prices We can send the goods to all world countries as CIF delivery L:225cm W:95cm H:160cm Q:1150 kgs.
75 kva generator sets Motor brand : ricardo Alternator brand : gentech Cylinder numbers : 75 kva ( 4 cylinders ) Rpm : 1500 Working systems : automatic The brand of control modules : datakom Fuel systems : diesel Delivery terms : fob istanbul or cif Warranty : international 1 year spare part warranty Quality standard certificates : ce / iso 9001 / ohsas 18001 / iso 14001 / gost-r / tse All products that we manufacture are in the a class quality Gentech alternators have been entirely manufacturing with turkish property products in gucbir factory in turkey Datakom control panels have been entirely manufacturing with turkish property products in turkey datakom facilities. We have productions of automatic, manuel, portable generators as optional Please contact us for our competitive export prices. We can send the goods to all world countries as cif delivery L:225 cm W:95 cm H:160 cm Q:1150 kgs.
90 kVA Generator Sets Motor Brand : Ricardo Alternator Brand : Gentech Cylinder Numbers : 75 kVA ( 4 Cylinders ) Rpm : 1500 rpm. ENGINE FEATURES •Diesel engine types suitable for heavy duty •4 stroke engine,water cooled •Mechanic/Electronic governor systems •Direct injection fuel system •Replacable cylinder jackets •12/24 Volt DC •Replacable oil filter,fuel filter and dry type air filter •Cooling radiator and fan •Flexible fuel hoses and oil outlet valve •Industrial muffler and flexible expansion compensator •Starter battery (lead acid) including wire and mount •Jacket water heater (for automatic models) ALTERNATOR FEATURES •Gentech brand,made in Turkey •Brushless,mono bearing,4 polar •Isolation class H •Protection class IP 21/22/23 •Self-alarm and regulated •Electronic automatic voltage regulator •2/3 stator windings to prevent harmonic failures •Windings are imprengiated with tropic epoxy resin against oil and acid CONTROL PANEL FEATURES •The control panel of monitoring,operation and safety is mounted on generator chassis •The features of automatic control panel : •Components on the panel •DKG 307 control module to monitor complete system •Static battery charger •Emergency stop button a) The features of generator control module DKG 307/DKG 309 •Automatic generator protection and control functions •Remote control function •Analaog displays for temperature and oil pressure •CosØ and KW displays for Generator •Engine operation time-clock •Maintenance time-clock •165 programmable parameters •Battery operated real-time clock •Weekly operating timer •Daily,weekly,monthly test •Fault recorder (with date and time info) •Statistical counters •Monitoring and recording at pc via RS-232 serial data port b) Displays on LCD monitor •Generator Volt (F-N) •Generator Ampere (L1,L2,L3) •Generator Frequency (Hz) •Generator CosØ •Generator Active Power (KW) •Oil Pressure (bar) •Cooling Water Temperature (0C) •Maintenance Timer •Network Volt (F-F/F-N) •Operating time display •Battery Voltage c) Alarms on LCD monitor •Overload/Over voltage •Over speed •Low/High network voltage •Low/High Generator Frequency •Cooling Water Level •Battery Alternator or Belt Breakage •Engine Low Oil Pressure •High Engine Temperature •Low Battery Voltage •Charge Failure L:260 cm W:95 cm H:165 cm Q:1400 kgs.
Standby 40 kVA Prime 36 kVA Rpm. 1500 Engine Model : R4105D Number of Cylinders: 4 Dimensions without Canopy ( WxHxL ) cm : 95 x 170 x 140 Dimensions including Canopy ( WxHxL ) cm: 95 x 245 x 160 Weight without Canopy kg. : 650 Maximum Fuel Consumption at Full Power: 6,6 Lt./Sa Fuel Tank Capacity: 130 Lt. Intake System: Natural Engine oil capacity Lt.. : 6 Engine water capacity Lt. : 12.
Standby 50 kVA Prime 45 kVA Rpm. 1500 Engine Model : R4105D Number of Cylinders: 4 Dimensions without Canopy ( WxHxL ) cm : 95 x 180 x 145 Dimensions including Canopy ( WxHxL ) cm: 95 x 245 x 160 Weight without Canopy kg. : 900 Maximum Fuel Consumption at Full Power: 8,1 Lt./Sa Fuel Tank Capacity: 140 Lt. Intake System: Turbo Charge Engine oil capacity Lt.. : 13 Engine water capacity Lt. : 16.
Standby 75 kVA Prime 68 kVA Rpm. 1500 Engine Model : R4105ZD Number of Cylinders: 4 Dimensions without Canopy ( WxHxL ) cm : 95 x 190 x 145 Dimensions including Canopy ( WxHxL ) cm: 95 x 245 x 160 Weight without Canopy kg. : 1200 Maximum Fuel Consumption at Full Power: 12,4 Lt./Sa Fuel Tank Capacity: 150 Lt. Intake System: Turbo Charge Engine oil capacity Lt.. : 13 Engine water capacity Lt. : 16.
Standby 90 kVA Prime 81 kVA Rpm. 1500 Engine Model : R4105IZLD Number of Cylinders: 4 Dimensions without Canopy ( WxHxL ) cm : 95 x 190 x 145 Dimensions including Canopy ( WxHxL ) cm: 95 x 245 x 160 Weight without Canopy kg. : 1400 Maximum Fuel Consumption at Full Power: 15,6 Lt./Sa Fuel Tank Capacity: 150 Lt. Intake System: Turbo Charge, Intercooler, Aftercooler Engine oil capacity Lt.. : 16 Engine water capacity Lt. : 25.
Diesel generator
Place of Origin - Turkey and Germany Brand Name - LOTUS Model Number - LOTUS-GEN LOTUS-GAS Usage - SVC Phase - Three Phase Protection - IP20 / IP55 / IP65 Frequency - 50Hz/60Hz Power factor - 0.8/0.9/1/Customized Color - Black or RAL7035 or Customized Rated power - 10KVA - 4000KVA