Welcome to wholesale high quality Heat Pump Split Air Conditioner Training Device at competitive price from professional Heat Pump Split Air Conditioner Training Device manufacturers and suppliers in China. Contact our factory for quotation and pricelist. We provide Heat...
Welcome to wholesale high quality General Air Conditioning Installation And Debugging Training Device at competitive price from professional General Air Conditioning Installation And Debugging Training Device manufacturers and suppliers in China. Contact our factory for...
We provide Automotive Crdi Engine Injection Control System Trainer with great production line and offer fast delivery, professional team, effiective function, friendly service, technology support.
Product description The Portable single-phase electric meter Test Equipment is used for grid corporation of measurement and energy test center, management department of power supply bureau, national energy measurement of testing authorities, and also used to test each kind of single phase kWh meter of industries and mining enterprises as well as electric meter manufacturers. Meanwhile, the calibrator also can be used as one high precision standard power source, ac voltage source and current source. Technical index Electrical parameters Accuracy class 0.05%, 0.1% Power Supply One Phase AC 100-265V, frequency 50/60Hz. AC Voltage Output Range 57.7V, 100V, 220V, 380V; max 500V Adjustment range (0-120)%RG(1) Adjustment 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. Stability 0.01%/120s Electrical parameters - continued Distortion 0.2% (Non-capacitive load) Output load max 25VA Measuring accuracy 0.05%RG AC Current Output Range 200mA, 1A, 5A, 20A, 60A(100A) optional; max 120A Adjustment range (0-120)%RG Adjustment 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. Stability
Product description Single-phase electric meter field calibrator is suitable to test various types single phase meters on site and can also be used to test alternating current parameters. Feature 1. Current clamp and meter combined together, colorful and touch-screen display; 2. One AAA Li-battery can continuously working 4 hours; 3. Wide voltage, current measurement range, voltage range: 15-300V, current range: 0.05-120A; 4. Display all the measuring parameters in one screen; 5. Current clamp has automatic compensation function, 0.2% class accuracy; 6. Current clamp has automatic calibration function; 7. Integration design of the meter and clamp; 8. 16bit high accuracy AD switch 32 bit ARM processor core. 9. Automatically record and save 999 groups calibrate data; 10. Micro-multifunction optic sampler Technical index 1. Manual/automatic test inductive single phase meters; 2. Manual/automatic test electric single phase meters; 3. Measure virtual value of alternating voltage (15 300Vrms); 4. Measure virtual value of alternating current (50mA 120Arms); 5. Test parameters: active power, phase angle of voltage and current, frequency and etc; 6. Automatic store testing data, and 999 group test results can besaved.
Product description The Single-phase capacitance and inductance tester is specially developed for the problem of measuring the capacitance value of the capacitor on the substation. Technical parameters Instrument measurement range and accuracy: a. Capacitance measurement (1) Measurable capacitance range (2) Measurable capacity range (3) Measurement accuracy (4) Resolution b. Current measurement (1)Current measurement range (2)Measurement accuracy (3)Resolution: 0.01A c. Inductance measurement (1)Inductance measurement range: small inductance mode 0.1mH 5mH large inductance mode 5 mH 50H
Overview: Generator Rotor AC Impedance Testing Instrument is a special instrument for determining whether the turn-to-turn short circuit exists in the generator rotor winding, and can manually and automatically (unidirectionally or bidirectionally) measure many parameters of the generator rotor such as voltage, current, impedance, power and rotating speed.Generator Rotor AC Impedance Testing Instrument is the latest enhanced AC impedance tester launched by our Company. The instrument adopts the state-of-the-art high speed microprocessor technology with more powerful functions, preferable performances and more convenient use. The Tester has a series of characteristics such as high reliability, easy operation, high test precision, being compact and lightweight and etc., and currently is in the domestic leading level. Major Technical Indicators Temperature: Relative Humidity: 0 1% FS+2d 0.1 0.5% FS+2d Frequency 40-75HZ 0.2% Weight 5kg
Product description SF6 3in 1Comprehensive SF6 Analyzer can be used to measure the purity of the product, the product will be used to achieve the function of two instruments to achieve a single instrument. A field survey, the most complete two indicators of detection, greatly save the gas in the device, a measure to save 1/2 gas consumption, while reducing the user's workload, improve the work efficiency. SF6 gas comprehensive tester Purity analyzer Technical index SF6 Purity (optional) Measurement range Precision SF6 Decomposition Measuring gas type and range CO: 0-1000ppm Sensitivity 0.1ppm Response time Sampling Built in regulator valve, filter, electronic flow meter Working power source AC / DC, built-in large capacity rechargeable battery, full of continuous working hours Weight About 3.5kg SF6 gas comprehensive tester Purity analyzer The product can be broken down, the purity measurement in one. A measurement can be completed a number of indicators. The full import of precision dew point measurement sensor, automatic zero calibration, anti oil, anti drift. The electronic flow display, power display. The file system support, data storage, printing. The instrument is a self diagnostic function, intelligent power display.
Product Introduction: SF6 intelligent micro water quality tester is developed and designed according to the national power industry standard DL/ t506-2007 insulation gas humidity measurement method for sulfur hexafluoride electrical equipment and adopts the imported high-precision dew point sensor and new digital circuit control technology. It is a high-precision intelligent instrument to measure the trace moisture content in SF6 gas. This instrument adopts intelligent self-calibration technology wide measurement range fast response high accuracy good linearity dynamic display of measurement curve. At the same time the instrument also has an automatic dryer which can greatly reduce the measurement time. Technical Parameters:
Product description Insulation Resistance Tester is suitable for measuring high capacity transformers, transformers, generators, high voltage electric motors, power capacitors, power cables, surge arresters and other ideal insulation resistance test equipment. Technical index Model BC2306 Rated Voltage 5000V 10000V Measuring Range
Overview Microcomputer relay protection tester also known as three-phase microcomputer relay protection tester, three-phase microcomputer relay protection tester is a special power relay protection tester.Three-phase microcomputer relay protection tester has 4 phase voltage 3 phase current output, suitable for various types of relay protection device test.Three-phase microcomputer relay protection tester adopts high speed and high performance digital control processor as control microcomputer, and the software uses double precision algorithm to generate arbitrary high precision waveform of each phase.Because of the integrated structure, each part is closely combined, the data transmission distance is short, and the structure is compact.It overcomes the problem of low number of output waveform points caused by long data communication line and narrow frequency band in the measurement and control instrument directly controlled by laptop computer. Technical parameter : AC current output Output accuracy 0.5A 2mA Phase current output (effective value) 0 40A Three merge current output (effective value) 0 120A Phase electric length time allows work value (effective value) 10A Phase current maximum output power 420VA Maximum output power at the maximum output of three 900VA Working time is allowed when the maximum output of the three mesh is output 10s Frequency range (fundamental) 20 1000Hz Harmonics 1 20 times AC voltage output Output accuracy Level 0.2 Phase voltage output valid value 120V Line voltage output valid value 210V Maximum voltage output value 240V Phase voltage / line voltage output power 80VA 100VA Frequency range (fundamental) 20 1000Hz Harmonics 1 20 times
Product description Current Transformer Analyzer is new product created after widely adopt customers advices and deep theoretical study. It is based on the automatic FA Series Transformer Tester General which is produced by our company that is widely acclaimed and applied. The adoption of high-performance DSP and ARM, advanced manufacturing technology ensure a stable and reliable product performance, full-featured, high degree of automation, high efficiency, in the domestic leading level, they are the professional testing equipments for transformer check in power industry. Technical Parameter CTA-1000 Usage CT PT Output Voltage measurement accuracy CT Ratio Range 1~40000 accuracy PT Ratio Range 1~40000 accuracy Phase Range accuracy 0.5min DC resistance Range 0~300 accuracy Burden Range 0~1000VA accuracy Power supply Environmental Conditions Weight and Dimensions
Product description: Transformer load box is also called current transformer load box, voltage transformer load box, PT load box and CT load box. Current, voltage transformer load box and transformer load box. When testing current and voltage transformers, PT/CT mutual inductance The load box provides a variety of effective loads and is an ideal accessory product for various transformer verification devices. Major Technical Index 1. Environmental conditions Temperature Humidity
Product description Insulation resistance tester with absorption ratio embedded real-time industrial microcomputer operating system, ultra-thin wire-shaped sheets header with the perfect combination of dot matrix liquid crystal display, the instrument is with a variety of voltage output level (250V,500V,1000V,2500V,5000V,10000V), high capacity, strong anti-interference, the pointer and digital synchronous display, AC-DC dual-use, simple operation, automatic calculation of various insulation index (absorption ratio, polarization index), all measured characteristics with the anti-power-down function . Technical index Measuring range and accuracy (Temperature, humidity: 23RH) Model BC2305 Rated Voltage 250V 500V 1000V 2500V 5000V Measuring Range
Product description Ground continuity tester is the connecting part of power equipment and grounding gird, during long time run of power equipment, Connection is likely due to moisture and other factors, node corrosion, even fracture phenomenon, lead to lead off the assembly line and the main grounding grid connection point resistance increase, there is no security risk in the operation of the equipment, serious when will cause the equipment to run away from the grounding grid. Technical index Technical parameter
Overview Light digital relay protection tester characteristics; 4/6/8 pairs of 100M Optical Fiber Communication Ethernet interface, can send and receive the sampling value of the IEC61850-9-1 / 2 frame format, Goose, IEEE-1588 packets; more support 24 sets of SV packets +64 groups of Goose packets simultaneously; 3/5 pairs of 2 10M fiber serial port, can send and receive IEC60044-7 / 8 FT3, national network expansion FT3, Xu Ji privately owned FT3 frame format sampling value 12 road simulation small signal output, provides testing of protection devices input for small signals; Technical parameter: Fiber Ethernet port S, ST, Mode, 1310nm; IEC61850-9-1 / 2 / Le, Goose, IEEE-1588; Send dispersion:
Overview The digital millisecond tape RS232 communication interface is widely used in electric power, electronics, telecommunications, railway, transportation and electromechanical, mechanical and other departments. It is used to measure the electromagnetic contact, remote device, and automatic device various action time, action intervals, machinery. The contacts, contacts, power switch main contacts, time, three phases, interval, tensile interval, tensilate, slightly separation, interval between closures, hierarchics, tensile gain machine B contact, and Active pulse lines such as various band switches, lock switches, limit switches, and universal conversion switches are (also available for sports), and measure the speed of the A point to the B point. Technical parameter: Measuring range 0.0001-999.9999 seconds Timing accuracy 0. 01% 2 words power supply AC 220V 10% 50Hz power 5W input signal Mechanical air contact or electrical signal (5-20V) Reset method Manual or software clearing Relative humidity 80%RH Dimensions 195*175*80 weight 1.5 kg
WOODEN SWEAT SCRAPER
Functional characteristics Transformer capacity and no-load tester Measure the transformer load current, load loss, short-circuit voltage, short circuit (load) losses, capability. Main technical parameters Capacity measuring range : 30kVA 31500kVA Current measuring range: 0 -100A auto-switch the measurement range Current measurement accuracy: (0.2% + 3digits) Voltage measurement range: Line Voltage0-750V;phase voltage 0-450V, auto-switch the measurement range Voltage measurement accuracy: (0.2% + 3digits) Insulation resistance: Leakage current:
Light Weight & Compact Best for Winching on Small Fishing Boats Simple: Just wire to the battery (12V, 24V) 2 speeds FAST/SLOW, change with lever Applications Winding anchor for boats / Drawing fishing net / Towing line / Winding up basket Material of motor case and roller : Corrosion resisting aluminum alloy and polyurethane coating Made in Japan PDF Catalog http://solid-corp.com/wp-content/uploads/catalog-marine-battery-winch-logo-2021.12.28.pdf