Please click here to check who's online and chat with them.

Find Verified Tools Instruments Suppliers, Manufacturers and Wholesalers

Jul-16-24
Supplier From Ambala Cantt, Haryana, India
Feb-17-12
Supplier From Ambala Cantt, Haryana, India
Dec-13-05
Supplier From Ambala, Haryana, India
Feb-11-22
 
Take temperature readings from a distance, or underwater, using this Waterproof DS18B20 Digital Temperature Sensor. It's got a 90cm (0.9m) cable with a stainless steel, PVC coated probe at the end. You'll be able to use it with any 3V-5V system, and take temperature readings with an accuracy of 9-12 Bits (configurable in code). The best part is that it's digital, meaning you won't suffer any signal degradation over the longer distance.

Waterproof - Take the temperatures of liquids/moist environments with the stainless steel probe. It's shrouded in PVC plastic too, meaning it will hold it's own in temperatures up to 100 degrees Celsius.
Temperature - Usable from -55 degrees Celsius to 125 degrees Celsius. Accuracy of 0.5 degrees.
Digital - The digital interface used to relay the readings guarantees minimal signal degradation over the longer distances (90cm for this standard cable)
1-wire interface - You can have multiple DS18B20s connected to the same central micro-controller pin as each device has a unique identifier hard-coded in.
Long range - 1.5 meters of cable by default, but you can make it longer if needed
Maker friendly - The DS18B20 chip is able to be powered with 3v - 5.5v which is perfect for maker platforms .
HOOK-UP GUIDE
This sensor is simple, you've got 3 wires (Power, Ground and Data). You simply need to connect the data pin to an input pin on your micro-controller and the power and ground to power and ground
You'll also need to connect a resistor between power and signal wires, as shown in the circuit diagram on the Sensor's wiki page.
Specifications
TECHNICAL SPECIFICATIONS
Compatible with 3.0V to 5.5V systems (development board etc)
Within 0.5 degrees Celsius accuracy
Recommended usable temperature range: -55 to 125 degrees Celsius
Select-able 9-12 bit resolution (Factory Default at 12-bit)
1 Wire Interface
Unique 64 bit ID for each sensor
Query time is less than 750ms
Stainless steel tube 6mm diameter by 35mm long
Cable diameter: 4mm
Cable Length: 90cm 100cm 200cm or Customized
Technology character
Jun-29-22
Supplier From Weihai, Shandong, China
14877 Tools Instruments Suppliers
Short on time? Let Tools Instruments sellers contact you.
Jul-29-20
Supplier From Sialkot, Punjab, Pakistan
Jul-27-16
Supplier From Anshan, Liaoning, China
VERIFIED
Sep-17-23
Supplier From Aurangabad, Maharashtra, India
Jul-27-06
Supplier From Sialkot, Punjab, Pakistan
Apr-10-09
Supplier From Guangzhou, Guangdong, China
Aug-26-22
 
Product description

Transformer calibrator is a new automatic instrument. We apply advanced electronic technology in the design. By directly decomposing the error signal, it is able to display the percentage, phase error and orthogonal error statistically. It s quick and energy saving. And it s especially good for live testing due to its cute dimension and light weight.



Technical Parameters

Working Condition:

(1) Temperature: 5

(2) Relative humidity:
Aug-26-22
 
Product description

The current booster is used on checking current transformer,to be the power source supply once current for current transformer or to be other 50Hz single phase current source device.



Technical index

Temperature

Humidit

Capacity: 20kVA

Specification

Weight: 75Kg

Allow long-term work on the rated current

Allowable overload 1.5 times,30 minutes of continuous work.



Feature

This PSLLQ is make up of input Winding(220V), output winding below 100A and CXRZ.

Output current indicated on the nameplate is defined the rated current that through winding allow to pass.When CX many circles, the rated current its permitted to pass through will inversely decline.

The value which ouput capcity divided by product of output current and each circle voltage was the biggest circle number allowing.



The current booster is designed to provide the primary current power supply for the current transformer when verifying the current transformer or as other 50HZ single-phase power equipment. The current booster for transformer verification is suitable for power departments such as power testing, power measurement, and power maintenance. The current booster is developed and produced according to the industry standard of transformer error testing, and is used as a current transformer to verify the primary current of the current transformer. The output current can be customized according to customer requirements. The lifter is equipped with casters for easy on-site movement.
Jul-29-22
 
Supper cutt scieser made with stainless steel
420 grade , full polished ,
May-06-22
 
Overview

The three-phase microcomputer relay control tester has a 4-phase voltage 3 phase current output, which is suitable for various types of relay protection devices. The microcomputer relay control tester uses a high-speed high-performance digital signal processor comparative speed, transmission frequency bandwidth, and software application bifurcation algorithm produces each of the respective high-precision waveforms. Due to the integrated structure, each part is closely coupled, the data transmission distance is short, and the structure is compact.



Technical parameter:

AC current output
Output accuracy Level 0.5
Phase current output (effective value) 0 40A
Three merge current output (effective value) 0 120A
Phase electric length time allows work value (effective value) 10A
Phase current maximum output power 420VA
Maximum output power at the maximum output of three 1000VA
Working time is allowed when the maximum output of the three mesh is output 10s
Frequency range (foundation) 20 1000Hz
Harmonic number 1 20 times
DC current output
Output accuracy Level 0.5
Current output 0 10A / each phase, 0 20A / two superimposed
Maximum output load voltage 20V
AC voltage output
Output accuracy Level 0.5
Phase voltage output (effective value) 0120V
Line voltage output (effective value) 0210V
Maximum voltage output value 0240V
Phase voltage / line voltage output power 80VA /100VA
Frequency range (fundamental) 201000Hz
Harmonics 1 20 times
Apr-29-22
 
Overview

The digital three-phase shifter is a portable electrical tester composed of transformer phase shifter, digital phase display, voltage current digital display, output voltage adjustment, coarse adjustment, fine adjustment, and power supply, etc. The digital three-phase shifter combines the transformer phase phase technology with digital measurement techniques, which can be adjusted at any angle in the range of 0 to 360 , which has high precision, reading. Accurate intuitive, the voltage output is adjustable, the digital three-phase shifter structural components use independent fixtures, firm and reliable, full seals, easy to carry in the field and on-site use.



Technical parameter

Input voltage Three-phase four-wire 3 380 (220) V 50Hz
The output voltage Three-phase four-wire 3 (0 380) / (0 220) Triple semi-digital display, accuracy: level 1
Output current Communication 0 ~ 20A Triple semi-digital display, accuracy: level 1
Maximum output capacity 3 300VA
Three-phase coarse Ambient temperature: 0 360 Move 30 per step
Dec-24-21
 
Product Introduction
SF6 intelligent micro water quality tester is developed and designed according to the national power industry standard DL t506 2007 insulation gas humidity measurement method for sulfur hexafluoride electrical equipment and adopts the imported high precision dew point sensor and new digital circuit control technology. It is a high-precision intelligent instrument to measure the trace moisture content in SF6 gas.

This instrument adopts intelligent self calibration technology wide measurement range fast response high accuracy good linearity dynamic display of measurement curve. At the same time the instrument also has an automatic dryer which can greatly reduce the measurement time.



Technical Parameters




Measuring range Dew point value 80 20
Moisture content 0 19999uLL
Accuracy of measurement 0.5 60 20
1.0 80 60
The resolution of the Dew point value 0.1
Moisture content 1uLL
Response time 20 0.1mpa 63 needs 5s 90 needs 45s 60 20
63 needs 10s 90 needs 240s 20 60
Sampling flow 0.6L min 20
Pressure range 01.0Mpa
The use of temperature 20 60
Environmental humidity 0 100 RH
Storage temperature 20 80
Charging time 4 hours
The whole machine size 250 150 300mm3
The weight of The machine 3.5kg
Dec-23-21
 
OVERVIEW

Many power systems, railway systems, large-scale petrochemical plants and enterprises have a lot of electrical equipment whose internal insulation are mostly oil filled insulation type, and therefore, test on insulating oil dielectric strength is common and necessary. To meet the needs of the market, we have developed and produced a series of insulating oil dielectric strength testers according to national standard GB T507-2002, industry standard DL429.9 91 and the latest Electric Power Industry Standard DL T846.7-2004 by ourselves. This instrument, by using a single chip microcomputer as the core, can operate in full automation with high accuracy, greatly improving work efficiency and reducing the labor intensity of workers. Moreover, it is small in size and convenient to carry.



MAJOR TECHNICAL INDICATORS

Output voltage 0 100KV optional

Voltage distortion rate 3

Voltage raising speed 0.5 5 KVS adjustable

Standing time 15min adjustable

Boosting interval 5 min adjustable

Boosting frequency 1 9 time s optional

Booster capacity 1.5KVA

Measuring accuracy 3

Supply voltage AC220V 10

50Hz1 Hz

Power 200W

Applicable temperature 0 45

Applicable humidity 75 RH

Overall dimension 465 385 425

Transformer Oil Dielectric Strength Tester 2
Dec-16-21
 
Product description

Insulating boots and gloves withstand voltage device is a power frequency power supply with low voltage working voltage of 220V 50Hz for insulating boots and gloves. According to the principle of electromagnetic induction, the input voltage is changed to the minimum value required for the test. high pressure. Insulating boots gloves withstand voltage test device generally consists of a special dedicated test box, an intelligent power frequency withstand voltage console, and a power frequency withstand voltage test transformer.

A special water tank can be customized according to needs to test 68 insulated boots or 6 insulated gloves at a time, and display the leakage current of the insulated boots or insulated gloves at the same time. The intelligent power frequency withstand voltage console is equipped with overcurrent protection and zero protection. Time protection and alarm function. The preventive voltage resistance test device for insulating boots and gloves is a special product developed and produced according to the needs of users according to the test procedures of insulating boots gloves
Dec-15-21

Zinc Oxide Arrester Tester

$770.00 - $15.4k
MOQ: Not Specified
 
Product description

The metal oxide arrester tester is used for the measurement and analysis of metal oxide arrester MOA leakage. It is mainly used for measuring the resistive current to analyze the degree of zinc oxide aging and damp. The field charged test shall conform to Electric Power Industry Standard of the People's DL474.5-92 Guide for Insulation Test on Site - Lightning Arrester Tests. The metal oxide arrester tester can be also used for factory and acceptance tests.



Zinc oxide arrester tester Technical Indexes

Range of reference voltage input peak 10V-200V

Measurement range of full leakage current peak 100uA 10mA

Measurement range of resistive current peak 100uA 10mA

Measurement range of capacitive current peak 100uA 10mA

Measurement range of angle 0-90

Power consumption 4W

System measurement accuracy reading 5 5 words not more than 2m for harmonic current

AC power supply AC 220V 10 50Hz 1



Precautions

When measure the reference voltage from PT or the measuring end of the testing transformer, carefully check wiring to avoid the PT secondary or test voltage short circuit.

Be careful not to wrongly connect the current and voltage sampling lines in the connecting process.

In the laboratory experiment, the high voltage power supply cannot use the series excitation testing transformer.
Dec-15-21
 
Overview

Frequency conversion series resonance test device is designed and manufactured for alternating-current withstand voltage test of Possessing a wider application scope, it is the ideal withstand voltage equipment for prefecture-level, municipal-level and county-level high-voltage test departements as well as power installation and repair & testing engineering units.

Frequency Conversion Series Resonance Test Device

Technical index

Rated voltage

Quality factor under full load in test of fire power generator Q 10 relating to load

Quality factor under full load in cable test Q 30 relating to load
Quality factor under full load in test of main transformer: Q 30 relating to load

GIS, the quality factor under full load in switch test and other tests Q 50 relating to load

Input power supply single phase of 380V

Frequency adjustment range 20Hz 300Hz

Accuracy of system measurement 1.5

The unit possesses protective functions, such as over voltage, over current and zero start.



Description for main configuration and technical data of equipment

One set of variable-frequency power supply

Rated power 10kVA;

Input voltage single phrase of 220V or three phase of 380V 10 and 45 65Hz

Output voltage 0 400V adjustable

Output voltage frequency 30 300Hz

0.1Hz adjustable stepping

Instability degree of frequency 0.02

Output current: 0 25A
14877 Tools Instruments Suppliers
Short on time? Let Tools Instruments sellers contact you.