Tube stand (xts-01) Type : floor-to-ceiling rail Distance of longitudinal travel : 2550mm Distance of vertical travel : 1600mm Rotation of x-ray tube : ±180° Lock system : electromagnetic lock by manual Weight : 170kg Ceiling (xce-01, option) Type : ceiling rail Distance of longitudinal travel : 2800mm Distance of vertical travel : 1200mm Rotation of x-ray tube : ±180° Lock system : electromagnetic lock by manual Weight : 130kg Bucky stand (xbs-01, option) Type : vertical travel Distance of vertical travel : 120mm ~ 1780mm X-ray grid : grid ratio of 8:1, 103 line/inch Front plate to film distance : 50mm Weight : 105kg 4way type bucky table (xbt4-01) Type : 4way travel Longitudinal distance of tabletop sliding : 420±5mm Lateral distance of tabletop sliding : 120±5mm Tabletop to floor distance : 665mm X-ray grid : grid ratio of 8:1, 103line/inch Dimensions : 2000l x 750w x 665h (mm) Weight : 150kg 6way type bucky table (xbt6-01, option) Type : 6way travel Drive type : electric motor drive X-ray grid : grid ratio of 8:1, 103line/inch Longitudinal distance of tabletop sliding : 420±5mm Lateral distance of tabletop sliding : 120±5mm Vertical distance of tabletop : 300±5mm Tabletop to floor distance : 689(880)mm Dimensions : 2000l x 750w x 680(880)h (mm) Weight : 170kg High voltage cable (hvc-6/8) Length : 6m/8m Maximum voltage : dc 75kv The number of core line : 3 lines
Type : Manual Maximum field size : Less than 35cm X 35cm at SID 65cm Minimum field size : Less than 5cm X 5cm at SID 100cm Luminosity : More than 160Lux Inherent filtration : 1.2mmAL Weight : 5kg Bucky Stand (XBS-01, Option) Type : Vertical travel Distance of vertical travel : 120mm ~ 1780mm X-ray Grid : Grid ratio of 8:1, 103 Line/inch Front plate to film distance : 50mm Weight : 105kg 4Way type Bucky Table (XBT4-01) Type : 4Way travel Longitudinal distance of tabletop sliding : 420¢®¨ú5mm Lateral distance of tabletop sliding : 120¢®¨ú5mm Tabletop to floor distance : 665mm X-ray Grid : Grid ratio of 8:1, 103Line/inch Dimensions : 2000L X 750W X 665H (mm) Weight : 150kg 6Way type Bucky Table (XBT6-01, Option) Type : 6Way travel Drive type : Electric motor drive X-ray Grid : Grid ratio of 8:1, 103Line/inch Longitudinal distance of tabletop sliding : 420¢®¨ú5mm Lateral distance of tabletop sliding : 120¢®¨ú5mm Vertical distance of tabletop : 300¢®¨ú5mm Tabletop to floor distance : 689(880)mm Dimensions : 2000L X 750W X 680(880)H (mm) Weight : 170kg High Voltage Cable (HVC-6/8) Length : 6m/8m Maximum voltage : DC 75KV The number of core line : 3 lines ***Upgradable with High Frequency Capacitor-module (Option
Tube kV/mA : 40-70 kV/2~6mA Exposure Time : 0.06~2.0 sec. Focal Spot : 0.4 mm Output Power : 420 w Size : 165.3 x 176.0 x 255.6 mm Weight : 2.4 kg Battery : DC 22.2V, 1,800 mAh
FV4343 CsI Wired (430 x 430mm) Single substrate amorphous silicon TFT / Diode array MTF : 36% typ.@2.0 cy/mm / DQE : 70% typ.@0vy/mm Sensor Pixel : over 3072 x 3072, 9M pixels Resolution : 3.5cy/mm typ. Interface : Giga bit Ethernet Preview image: 3sec Recommended Cycle Time : Less than 10sec Input AC : 100~240V. 50/60Hz Power Consumption : Less than 20W
medical DR x-ray system 17x17" / Wired / GOS / US FDA / CE
- Wired / 17" x 17" / GOS / US FDA / CE - Console software included
- Wired / 17"x17" / CsI / US FDA / CE - Console software included
medical DR x-ray system 17x17" / Wired / GOS / US FDA / CE
X-ray protective Aprons - Lead Apron - Lead-Free Apron
MEDIKORS Inc. develope InAlyzer the worlds first digital diagnostic X-ray imaging system uses DXA(Dual X-ray Absorptiometry). InAlyzer can analyze Bone Mineral Density and Body Composition(BMC, FAT, LEAN) of alive laboratory animal in units of 0.001g with simple anesthesia without killing them. And it is possible to track and observe the follow-up for each entity of alive lab animals that can save the time, labor, and cost practically. Moreover, InAlyzer have researcher be safe from the radiation by blocking out the outside exposure of the radiation with internal protection structure. Additionally, InAlyzer approved the effectiveness, accuracy, and successful qualification in the preclinical phase.