- Available in Adult, Child and Infant size.
- Reusable manual resuscitators are autoclavable to 125 degrees Celsius (Polycarbonate) or 136 degrees Celsius(Polysulfone).
- Accessories like oxygen tubing, reservoir bags, masks, airways can be specified according to requests.
-OEM/ODM request are welcome.
GK(F) series is the vertical centrifuge funning continuously but discharging intermittently. PLC system is adopted in the centrifuge so stepless speed regulation and electric braking can be realized in braking system by frequency-conversion speed regulation. Automatic cycle operation can be finished in whole process by material level detection, revolving speed inspection and vibration monitoring (including the process such as: feeding, separation and dehydration, washing discharging and net washing etc.). Manual control and operation can also as adopted.
In addition to medium and fine grains. GK(F) Series Automatic Horizontal Scraper Centrifuge can also be applied in the solid-liquid separation such as: fine grains, low filter velocity material, poisonous, harmful, flammable and explosive materials. Therefore, it is widely used for solid-liquid separation of pharmacy., food, chemical industry and national defense
Product Description:
SANLI blood collection needle for single use
Product Specification/Models:
blood collection set
Size: 18G,20G,21G,22G,23G,24G,25G
Color: pink, yellow, green, black, blue, orange
Holder for Multi-sample needle 20mm*55mm
Holder for butterfly needle 19mm*53mm
Other Information:
We are professional manufactory dealing especially with the export of blood collection kits. We are in a position to accept orders according to the customer's samples.
Certificate: CE
Payment:
L/C, T/T, Cash
Delivery:
DHL , TNT ,EMS
Origin:
HUNAN LIUYANG
Minimum Order:
100000
Packaging:
6000/BOX
Samples:
Free
Sample Price:
US$0
Remarks:
We are professional manufactory dealing especially with the export of blood collection kits. We are in a position to accept orders according to the customer's samples.
EPGT tube stands on EDTAK2 with Gel Tube. It is coated with lithium heparin and inside the tube a barrier Gel presented at the bottom.
Product Feature
they are normally made of glass and plastic. In addition, the plastic tube includes PET, PP and PS.
Product Specification/Models
1ml 13í-75mm VP10041S
2ml VP20031S
3ml VP30031S
4ml 13í-100mm VP40042S
5ml VP50032S
6ml VP60032S
8ml 16í-100mm VP80043S
9ml VP90043S
Application. Through centrifugation, the separation gel can form a barrier between plasma and blood cell and totally separate them. Clinical specimen obtained is suitable for analysis of virus capacity and molecular diagnostics of undiluted plasms.
Other Information
We are professional manufactory dealing especially with the export of blood collection kits. We are in a position to accept orders according to the customer's samples.
Product feature
They are normally made of glass and plastic. In addition, the plastic tube includes pet , pp and ps.
Product specification/models
3ml 13íß75mm vp30011s
4ml vp40011s
5ml vp50011s
3ml 13íß100mmvp30012s
4ml vp40012s
5ml vp50012s
6ml vp60012s
8ml 16íß100mmvp80013s
9ml vp90013s
Application
It is used for collecting blood specimen for biochemistry and immunology tests, especially fast in blood coagulation.
Other information
We are professional manufactory dealing especially with the export of blood collection kits. We are in a position to accept orders according to the customer's samples.
Ssgt tube stands on clot activator with gel tube. It is coated with clot activator and inside the tube a barrier gel presented at the bottom.
Product feature
They are normally made of glass and plastic. In addition, the plastic tube includes pet, pp and ps.
Product specification/models
3ml 13íß75mm vp30021s
3.5ml vp35021s
3ml 13íß100mm vp30022s
4ml vp40022s
5ml vp50022s
7ml 16íß100mm vp70023s
8ml vp80023s
Application
It is used for clinical biochemistry and immunology. The obvious characteristic of ssgt tube is used to obtain high-quality plasma specimen for medical laboratories.
Other information
We are professional manufactory dealing especially with the export of blood collection kits. We are in a position to accept orders according to the customer's samples.
Product specification/models
Infant blood collection tube: 8*45mm
Color: red, yellow, lavender, green, black, gray, blue.
Application
It's used for children's blood collection
Other information
We are professional manufactory dealing especially with the export of blood collection kits. We are in a position to accept orders according to the customer's samples.
S350 Zeiss type Slit Lamps(3 or 5 magnifictaions)
With CE and ISO13485 marks
MICROSCOPE
Type: Galilean optical system
Configuration: Zeiss type
Eyepiece: 12.5x
Angle between eyepieces: 13 degree binocular tube with converging optics
Magnification change: 3 or 5 steps by revolving drum
Total magnification and field of view (mm): 10X (22), 16X (13.5), 25X (8.5) / 6X (34.7), 40 X (5.5)
Pupilary adjustment: 55mm~78.5mm
Diopter adjustment: -6d~+6d
Slit illumination
Slit width: Continuous from 14mm to 0mm(at 14mm, slit becomes a circle)
Slit length: Continuous from 14mm to 1mm(at 14mm, slit becomes a circle)
Slit angle: 0 to 180 degree(continuously adjustable both vertical and horizontal)
Aperture diameters: 14mm, 8mm, 3.5mm, 0.5mm
Filter:Thermal safety, Cobalt Blue, Red-free
Lamp: German imported 6v, 20w halogen lamp(OSRAM) or LED lamp.
Accessories: Applanation Tonometer, Beam Splitter, DC Adaptor, DC, Video Camera Adaptor, Video Camera, Teaching Tube, etc...
Yellow Filter, Amber Filter and Measuring Eyepiece are available.
TRIPLE WALL CORRUGATED FIBREBOARD BOXES
Gross Weight:22KGS
Net Weight:20KGS
Dimension:740mm X 450mm X 500mm
S350 haag-streit type slit lamps (3 or 5 magnifictaions)
With ce and iso13485 marks
Microscope
Type: galilean optic system
Configuration: haag-streit type
Eyepiece: 12.5x
Angle between eyepieces: 13 degree binocular tube with converging optics
Magnification change: 3 or 5 steps by revolving drum
Total magnification and field of view (mm): 10x (22), 16x (13.5), 25x (8.5) / 6x (34.7), 40 x (5.5)
Pupilary adjustment: 55mm~78.5mm
Diopter adjustment: -6d~+6d
Slit illumination
Slit width: continuous from 14mm to 0mm (at 14mm, slit becomes a circle)
Slit length: continuous from 14mm to 1mm (at 14mm, slit becomes a circle)
Slit angle: 0 to 180 degree(continuously adjustable both vertical and horizontal)
Aperture diameters: 14mm, 10mm, 5mm, 3mm, 2mm, 1mm, 0.2mm
Filter: thermal safety, uv, cobalt blue, red-free
Slit inclination 4 steps: 5 degree, 10 degree, 15 degree, 20 degree
Lamp: german imported 6v, 20w halogen lamp (osram) or led lamp.
Accessories: applanation tonometer, beam splitter, dc adaptor, dc, video camera adaptor, video camera, teaching tube, etc...
Yellow filter, amber filter and measuring eyepiece are available.
Triple wall corrugated fibreboard boxes
Gross weight:25kgs
Net weight:24kgs
Dimension:740mm x 450mm x 500mm
Display Mode : double Color OLED display
SPO2 measuring range: 35-100%
Pulse Ratio:30-240 BPM
Pulse Waveform display: bargraph display
Battery indication: OLED display
Power Requirements: 1.5V(A A A size )Alkali Batteriesí-2
Adaptable range:2.6V-3.6V
Working current:í_20mA
Resolution: SPO2 : 1% Pulse Rate: 1bpm
Accuracy: SPO2 :70% to 100% í+2digits,below 70% unspecified Pulse rate:í+2bpm or í+ 2%(select larger)
Measurement at Low Perfusion: The values of SPO2 and pulse rate can be displayed properly when pulse saturation is at 0.4%.
Accuracy of SPO2:í+4% Accuracy of Pulse Ratio.í+2BPM or í+2% (Select Larger)
Resistance to surrounding light: Deviation is smaller than í+1% between value of Oxyhemoglobin measured in natural lighting indoor condition and present lighting sources and that measured in dark room.
Automatic shutdown function: The device will power off automatically within 5 seconds when there is no finger in the device.
When working, the display direction can be changed by pressing the button shortly. There are six modes of direction.
In working term, long press can change the lighteness of the screen.
Display Format: LCD
SPO2:35-99%
Pulse Ratio:30-255 BPM
Pulse Wave: LCD Numeric Display
Battery Voltage Low Indication: LCD Bar Graph.
Power Requirements: Two AAA size 1.5V Alkaline Batteries
Power Consumption: less than 15 mA.
Resolution: 1% for SPO2 and 1 BPM for Pulse Rate.
Measurement Accuracy: í+2% in stage of 70%-99% for SPO2
Unspecified in stage of 35-69% for SPO2
í+2BPM or í+2%(Select Larger)for Pulse Rate.
Measurement Performance in Low Perfusion: SPO2 and pulse & rate can be shown correctly
when pulse-perfusion ratio is 0.4%
Interference Resistance Capacity against Ambient Light : Deviation is smaller than í+1%
It is equipped with a function switch, through which the Oximeter can be automatically powered off
when no finger is in the Oximeter more than 4 seconds
5280 Other Medical Equipments Suppliers
Short on time? Let Other Medical Equipments sellers contact you.